• Title/Summary/Keyword: 전산화 단층촬영

Search Result 1,092, Processing Time 0.031 seconds

Study of the CatcherTM Couch's Usefulness (토모치료기 CatcherTM Couch의 유용성에 대한 고찰)

  • Um, Ki Cheon;Lee, Chung Hwan;Jeon, Soo Dong;Song, Heung Kwon;Back, Geum Mun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.31 no.2
    • /
    • pp.65-74
    • /
    • 2019
  • Purpose: Recently, A Catcher was added to prevent sagging in Radixact® X9. In this study, We quantitatively compared general couch of Tomo-HDA® with catcher couch of Radixact® X9 using the human phantom and evaluated usefulness of catcher. Materials and methods: We used rando phantom for phantom study and set the each iso-center of head and neck region and Pelvis region for region parameter. Furthermore, We used hand made low melting point alloys for weight parameter. MVCT(Mega Voltage Computed Tomography) images were acquired for vertical error and rotation(pitch) error measurement increasing weight(A: 15kg, A+B: 30kg, A+B+C: 45kg). We selected 120 patients who has been treated using Tomotherpy machine for patient study. 60 patients has been treated in Tomo-HDA® and the other 60 patients treated in Radixact® X9. In the patient study methods, vertical error and rotation(pitch) error was measured for mean value calculation using MVCT images acquired on first day of radiation therapy. Result: Result of phantom study, Vertical error and rotation(pitch) error was increased proportionally increased as the weight increases in general couch of Tomo-HDA®. each maximum value was 7.52mm, 0.38° in head and neck region and 11.94mm, 0.92° in pelvis region. However, We could confirm that there was stable error range(0.02~0.1mm, 0~0.04°) in Catcher couch of Radixact®. Result of patient study, The head and neck region was measured 4.79mm 0.33° lower, and the pelvis region was measured 7.66mm, 0.22° lower in Catcher couch of Radixact® X9. Conclusion: In this study, Vertical error and rotation(pitch) error was proportionally increased as the weight increases in general couch of Tomo-HDA®. Especially, The pelvis region error was more increased than the head and neck region error. However, Vertical error and rotation(pitch) error was regularly generated regardless of weight or regions in CatcherTM couch of Radixact® X9 that this study's purpose. In conclusion, CatcherTM couch of Radixact® X9 can minimize mechanical error that couch sagging. Furthermore, The pelvis region is more efficiency than head and neck region. In radiation therapy using Tomotherapy machine, it is regarded that may contribute to minimizing unadjusted pitch error due to characters of Tomotherapy.

The pattern of movement and stress distribution during retraction of maxillary incisors using a 3-D finite element method (상악 전치부 후방 견인 시 이동 양상과 응력 분포에 관한 삼차원 유한요소법적 연구)

  • Chung, Ae-Jin;Kim, Un-Su;Lee, Soo-Haeng;Kang, Seong-Soo;Choi, Hee-In;Jo, Jin-Hyung;Kim, Sang-Cheol
    • The korean journal of orthodontics
    • /
    • v.37 no.2 s.121
    • /
    • pp.98-113
    • /
    • 2007
  • Objective: The purpose of this study was to evaluate the displacement pattern and the stress distribution shown on a finite element model 3-D visualization of a dry human skull using CT during the retraction of upper anterior teeth. Methods: Experimental groups were differentiated into 8 groups according to corticotomy, anchorage (buccal: mini implant between the maxillary second premolar and first molar and second premolar reinforced with a mini Implant, palatal: mini implant between the maxillary first molar and second molar and mini implant on the midpalatal suture) and force application point (use of a power arm or not). Results: In cases where anterior teeth were retracted by a conventional T-loop arch wire, the anterior teeth tipped more postero-inferiorly and the posterior teeth moved slightly in a mesial direction. In cases where anterior teeth were retracted with corticotomy, the stress at the anterior bone segment was distributed widely and showed a smaller degree of tipping movement of the anterior teeth, but with a greater amount of displacement. In cases where anterior teeth were retracted from the buccal side with force applied to the mini implant placed between the maxillary second premolar and the first molar to the canine power arm, it showed that a smaller degree of tipping movement was generated than when force was applied to the second premolar reinforced with a mini implant from the canine bracket. In cases where anterior teeth were retracted from the palatal side with force applied to the mini implant on the midpalatal suture, it resulted in a greater degree of tipping movement than when force was applied to the mini implant between the maxillary first and second molars. Conclusion: The results of this study verifies the effects of corticotomies and the effects of controlling orthodontic force vectors during tooth movement.

The Correlation between the Radiological Changes and the Level of Transforming Growth Factor-β1 in Patients with Pulmonary Tuberculosis (폐결핵의 영상학적 진행과 Transforming Growth Factor-β1 농도와의 관련성)

  • Cho, Yongseon;Lee, Yang Deok;Cho, Wook;Na, Dong Jib;Han, Min Soo
    • Tuberculosis and Respiratory Diseases
    • /
    • v.60 no.3
    • /
    • pp.297-303
    • /
    • 2006
  • Background : Pulmonary tuberculosis is frequently accompanied with complications such as bronchiectasis, cavities, fibrosis and a deterioration of the lung function. However, there is little information available on the pathogenesis of these complications in pulmonary tuberculosis. Among the many factors involving in tissue remodeling, transforming growth factor-${\beta}1$ ($TGF-{\beta}1$) is a potent stimulus of the extracellular matrix fomation and a mediator of potential relevance for airway wall remodeling. Therefore, this study examined the relationship between the radiological changes and the $TGF-{\beta}1$ level in patients with pulmonary tuberculosis. Methods : Serum and bronchoalveolar lavage fluid (BALF) were collected from total of 35 patients before treating them for active pulmonary tuberculosis, and the $TGF-{\beta}1$ levels were measured using an enzyme-linked immunosorbent assay (ELISA). The BALF levels were recalculated as the epithelial lining fluid (ELF) levels using the albumin method. pulmonary function test (PFT) and high resolution computed tomography (HRCT) were performed before and after treatment. Results : There was a strong correlation between the serum $TGF-{\beta}1$ level and the presence of cavities (r=0.404, p=0.006), even though the BAL $TGF-{\beta}1$ level showed a weak correlation with complications. In addition, there was no correlation between the $TGF-{\beta}1$ levels before treatment and the changes in the PFT and HRCT during treatment. Conclusion : There is a correlation between the serum $TGF-{\beta}1$ level and cavity formation in pulmonary tuberculosis before treatment. However, further study will be needed to confirm this.

Clinical Features of Patients with Lung Cancer and Upper Aerodigestive Tract Cancer (폐암과 상부소화호흡기암이 동반된 환자의 경우 임상적 특징)

  • Lee, Chang Youl;Chung, Jae Hee;Chang, Yoon Soo;Kim, Se Kyu;Kim, Hyung Jung;Chang, Joon;Kim, Sung Kyu;Ahn, Chul Min
    • Tuberculosis and Respiratory Diseases
    • /
    • v.62 no.4
    • /
    • pp.284-289
    • /
    • 2007
  • Background: To define the clinical features of patients with lung and upper aerodigestive tract cancer through a review of the histopathology, clinical features and follow-up results. Methods: Patients with lung and upper aerodigestive tract cancer who were diagnosed in Young dong Severance Hospital from 1992 to 2005, were retrospectively reviewed. The clinical data, radiologic findings, pathologic findings, treatment modalities were evaluated. Result: There was a total of 20 patients with aerodigestive tract cancer who were diagnosed with lung cancer over a 13 years period. The mean age was $58.45{\pm}15.09$ years and 19 cases were male. There were 14 smokers with an average pack year of 46 years. Twelve patients had aerodigestive tract cancer and later developed lung cancer, and 5 lung cancer patients were later diagnosed with aerodigestive tract cancer. Conclusion: These results suggest that cancers of the aerodigestive tract and lung can arise as either dependent or independent events and most aerodigestive tract cancer patients who developed lung cancer are not treated properly. Therefore, regular low dose chest CT with close suspicion is needed to properly manage upper aerodigestive tract cancer patients.

Differentiation of Parkinson's Disease and Essential Tremor on I-123 IPT(I-123-N-(3-iodopropen-2-yl)-$2{\beta}$-carbomethoxy- $3{\beta}$-(4-cholorophenyl) tropane) Brain SPECT (파킨슨병과 본태성 진전의 감별진단에서 I-123 IPT(I-123-N-(3-iodopropen-2-yl)-$2{\beta}$-carbomethoxy-$3{\beta}$-(4-cholorophenyl) tropane) 뇌 단일광전자방출 전산화단층촬영의 역할)

  • Pai, Moon-Sun;Choi, Tae-Hyun;Ahn, Sung-Min;Choi, Jai-Yong;Ryu, Won-Gee;Lee, Jae-Hoon;Ryu, Young-Hoon
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.43 no.2
    • /
    • pp.100-106
    • /
    • 2009
  • Purpose: The study was to assess I-123-N-(3-iodopropen-2-yl)-2[beta]-carbomethoxy-3[beta]-(4-cholorophenyl) tropane(IPT) SPECT in differential diagnosis among early stage of Parkinson's disease(PD) and essential tremor(ET) and normal control(NL) groups quantitatively. Materials and Methods: I-123 IPT brain SPECT of 50 NL, 20 early PD, 30 advanced PD, and 20 ET were performed at 20 minutes and 2 hours. Specific/nonspecific binding of striatum was calculated by using right and left striatal specific to occipital non-specific uptake ratio(striatum-OCC/OCC). Results: Mean value of specific/nonspecific binding ratio was significantly different between advanced PD group and NL group. However, significant overlap of striatal specific/nonspecific binding ratio was observed between PD group and ET group. Bilateral striatal specific/nonspecific binding ratios were decreased in advanced PD. Lateralized differences in the striatal uptake of I-123 IPT correlated with asymmetry in clinical findings in PD group. Conclusion: I-123 IPT SPECT may be a useful method for the diagnosis of PD and objective evaluation of progress of clinical stages. Care should be made in the differential diagnosis of early stage of PD and other motor disturbances mimicking PD such as ET in view of significant overlap in striatal I-123 specific/nonspecific binding ratio.

Long-term Outcome of Glycogen Storage Disease Type 1; Analysis of Risk Factors for Hepatic Adenoma (당원병 제1형의 장기 추적 관찰; 간선종 발생의 위험 요인에 대한 연구)

  • Yang, Hye-Ran;Seo, Jeong-Kee
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.6 no.2
    • /
    • pp.129-139
    • /
    • 2003
  • Purpose: The aim of the study was to evaluate the long-term outcome of glycogen storage disease (GSD) type 1 with particular reference to hepatic adenoma and hepatocellular carcinoma, and to analyze risk factors affecting the development of hepatic adenoma in GSD type 1. Methods: Forty-three GSD type 1 patients (31 males and 12 females, mean age $13.9{\pm}6.4$ years) were analyzed retrospectively. Hepatic adenoma was detected on abdominal USG and diagnosed on histologic examination. Clinical profiles were compared between patients with hepatic adenoma (n=16) and age-matched controls without hepatic adenoma (n=16). Results: 1) Of 43 GSD type 1 patients, 16 (37.2%) had hepatic adeoma. Hepatic adenoma was detected at the age of mean $14.2{\pm}4.1$ years (range: 7.9~25.7 years). Fourteen (87.5%) adenomas were multiple at detection. 2) Comparison of the clinical profiles between adenoma group and non-adenoma group revealed that age at first introduction of uncooked cornstarch treatment was significantly late in adenoma group compared with non-adenoma group ($9.1{\pm}5.2$ years vs. $3.0{\pm}1.8$ years, p=0.003). Portocaval shunt surgery was performed in 11 (68.8%) patients in adenoma group and 3 (18.8%) in non-adenoma group (p=0.004). Hepatic adenoma developed mean $5.8{\pm}4.2$ years after shunt operation. 3) One patient was diagnosed as hepatocellular carcinoma at the age of 25.7 years. Conclusion: Hepatic adenoma is an important late complication of GSD type 1 with the risk of malignant transformation. Early introduction of cornstarch therapy with strict metabolic control is needed to prevent the development of hepatic adenoma in GSD type 1.

  • PDF

Early and Midterm Results of Hybrid Endovascular Repair for Thoracic Aortic Disease (흉부대동맥 질환에서 시행된 하이브리드 혈관내 성형술의 중단기 성적)

  • Youn, Young-Nam;Kim, Kwan-Wook;Hong, Soon-Chang;Lee, Sak;Chang, Byung-Chul;Song, Seung-Jun
    • Journal of Chest Surgery
    • /
    • v.43 no.5
    • /
    • pp.490-498
    • /
    • 2010
  • Background: A hybrid procedure using an open surgical extra-anatomic bypass of aortic arch vessels and thoracic endovascular aortic repair (TEVAR) is less invasive than open surgery, and provides a suitable proximal landing zone. Here we report our experience with a hybrid TEVAR procedure at a single center. Material and Method: We retrospectively reviewed consecutive patients with thoracic aortic disease who received a hybrid TEVAR procedure between August 2008 and January 2010. Patients' data were prospectively collected and mean follow-up was $10.8{\pm}5.5$ months (range 3~20). Result: Nine patients (7 males and 2 females) with a mean age of $63.8{\pm}15.8$ years (range 38~84) underwent a hybrid procedure. Five patients had an arch or a proximal descending aortic aneurysm, two had a dissecting aneurysm of the descending aorta, and two had an aneurysm of the ascending arch and descending aorta. Mean expected mortality calculated by logistic EuroSCORE was 21%. Six patients underwent debranching and rerouting from ascending aorta to arch vessels, 2 had carotid-carotid bypass grafting, and 1 underwent carotid-axillary bypass grafting. Mean operation time was $221.4{\pm}84.0$ min (range 94~364). Deployment success of endovascular stent grafting was 100% with no endoleak on completion angiography. There was no mortality, and a small embolism in the branch of the right opthalmic artery in one patient. During follow-up, one intervention was required for the endoleak. Actuarial survival at 20 months was 100%. Conclusion: Early and mid-term results are encouraging and suggest that hybrid TEVAR procedures are less invasive and safer and represent an effective technique for treating thoracic aortic disease.

Comparison Radiation Dose of Z-Axis Automatic Tube Current Modulation Technique with Fixed Tube Current Multi-Detector Row CT Scanning of Lower Extremity Venography (하지 정맥조영술 MDCT에서 고정 관전류 기법과 Z-축 자동 관전류 변동 제어에 의한 선량 비교)

  • Yoo, Beong-Gyu;Lee, Jong-Seok;Jang, Keun-Jo;Jeon, Sang-Hwan;Kim, Yong-Soo;Kweon, Dae-Cheol
    • Journal of Radiation Protection and Research
    • /
    • v.32 no.3
    • /
    • pp.123-133
    • /
    • 2007
  • Z-axis automatic tube current modulation technique automatically adjusts tube current based on size of body region scanned. The purpose of the current study was to compare noise, and radiation dose of multi-detector row CT (MDCT) of lower extremity performed with Z-axis modulation technique of automatic tube current modulation with manual selection fixed tube current. Fifty consecutive underwent MDCT venography of lower extremity with use of a MDCT scanner fixed tube current and Z-axis automatic tube current modulation technique (10, 11 and 12 HU noise index, $70{\sim}450\;mA$). Scanning parameters included 120 kVp, 0.5 second gantry rotation time, 1.35:1 beam pitch, and 1 mm reconstructed section thickness. For each subject, images obtained with Z-axis modulation were compared with previous images obtained with fixed tube current (200, 250, 300 mA) and with other parameters identical. Images were compared for noise at five levels: iliac, femoral, popliteal, tibial, and peroneal vein of lower extremity. Tube current and gantry rotation time used for acquisitions at these levels were recorded. All CT examinations of study and control groups were diagnostically acceptable, though objective noise was significantly more with Z-axis automatic tube current modulation. Compared with fixed tube current, 2-axis modulation resulted in reduction of CTDIvol (range, $-6.5%{\sim}-35.6%$) and DLP (range, $-0.2%{\sim}-20.2%$). Compared with manually selected fixed tube current, 2-axis automatic tube current modulation resulted in reduced radiation dose at MDCT of lower extremity venography.

Treatment Outcomes and Acoustic Rhinometric Results in Endoscopic Sinus Surgery of Adult Chronic Paranasal Sinusitis (성인 말성 부비동염에서 내시경적 부비동 수술 전.후의 증상 호전도와 음향비강통기도 검사 결과)

  • Kim, Yong-Dae;Kim, Jae-Yeul;Chang, Keun-Young;Lee, Hyung-Joong;Song, Si-Youn;Yoon, Seok-Keun
    • Journal of Yeungnam Medical Science
    • /
    • v.19 no.1
    • /
    • pp.28-38
    • /
    • 2002
  • Background: Chronic paranasal sinusitis is one of the most common disease in the otorhinolaryngologic field. Endoscopic sinus surgery is treatment of choice in chronic paranasal sinusitis. The aim of this study was to evaluate objective and subjective treatment outcomes of endoscopic sinus surgery in adult chronic paranasal sinusitis with or without polyp. Materials and Methods: We reviewed 84 adult patients underwent endoscopic sinus surgery by one surgeon from June 1999 to June 2000, prospectively. We analyzed preoperative and postoperative subjective symptom scores and acoustic rhinometric results. Results: Fifty cases were male and thirty four cases female. The average age was of 33 year-old (range: 17 to 66 years). There was significantly improvement of symptom scores in postoperative 3 months and 6 months compared with preoperative symptom scores. There was significantly increased postoperative total volume of nasal cavity. When we compared high score group with low score group, there was statistically significant improvement of symptom scores between preoperative stage and postoperative 3 months in radiologic grading group. Conclusions: Endoscopic sinus surgery is considered to be effective for the treatment of chronic paranasal sinusitis. It seems to be helpful to employ subjective symptom score system and objective total volume change of nasal cavity through acoustic rhinometric test to analyze effectiveness of endoscopic sinus surgery. In this study, the most important preoperative factor of sinus surgery outcomes is radiologic grading system.

  • PDF

The Analysis of a Cerrobend Compensator and a Electronic Compensator Designed by a Radiation Treatment Planning System (방사선치료계획장치로 설계된 Cerrobend 선량보상체와 전자 선량보상체의 제작 및 특성 분석)

  • Nah Byung-Sik;Chung Woong-Ki;Ahn Sung-Ja;Nam Taek-keun;Yoon Mi-Sun;Song Ju-Young
    • Progress in Medical Physics
    • /
    • v.16 no.2
    • /
    • pp.82-88
    • /
    • 2005
  • In this study, the physical compensator made with the high density material, Cerrobend, and the electronic compensator realized by the movement of a dynamic multileaf collimator were analyzed in order to verify the properness of a design function in the commercial RTP (radiation treatment planning) system, Eclipse. The CT images of a phantom composed of the regions of five different thickness were acquired and the proper compensator which can make homogeneous dose distribution at the reference depth was designed in the RTP. The frame for the casting of Cerrobend compensator was made with a computerized automatic styrofoam cutting device and the Millennium MLC-120 was used for the electronic compensator. All the dose values and isodose distributions were measured with a radiographic EDR2 film. The deviation of a dose distribution was $\pm0.99 cGy\;and\;\pm1.82cGy$ in each case of a Cerrobend compensator and a electronic compensator compared with a $\pm13.93 cGy$ deviation in an open beam condition. Which showed the proper function of the designed compensators in the view point of a homogeneous dose distribution. When the absolute dose value was analyzed, the Cerrobend compensator showed a $+3.83\%$ error and the electronic compensator showed a $-4.37\%$ error in comparison with a dose value which was calculated in the RTP. These errors can be admtted as an reasonable results that approve the accuracy of the compensator design in the RTP considering the error in the process of the manufacturing of the Cerrobend compensator and the limitation of a film in the absolute dosimetry.

  • PDF