• Title/Summary/Keyword: 전산화단층촬영영상

Search Result 505, Processing Time 0.035 seconds

Radiologic Findings of Local Effect of Right Adrenal Pheochromocytoma on the Adjacent Liver: A Case Report (우측 부신에서 발생한 갈색세포종이 인접 간에 미치는 국소적 영향에 관한 영상의학적 소견 : 증례 보고)

  • Rhim, Jung-Hyo;Cho, Jeong-Yeon;Kim, Seung-Hyup
    • Investigative Magnetic Resonance Imaging
    • /
    • v.16 no.2
    • /
    • pp.173-176
    • /
    • 2012
  • We report the radiological findings of regional enhancement of the liver adjacent to the right adrenal pheochromocytoma. CT and MRI showed focal strong enhancement of adjacent liver tissue in the arterial phase. However during the delayed phase, the lesion showed iso-attenuation with normal hepatic parenchyma and not delineated. The lesion did not show abnormal signal intensity on neither T1 nor T2 weighted images and indistinguishable from normal parenchyma. The enhancing hepatic lesion was spontaneously regressed on postoperative follow up CT which was taken several months after the adrenalectomy.

Comparison of Bone Volume Measurements Using Conventional Single and Dual Energy Computed Tomography (전산화단층영상검사에서 단일에너지와 이중에너지를 이용한 뼈 부피측정의 비교)

  • Kim, Yung-kyoon;Park, Sang-Hoon;Kim, Yon-Min
    • Journal of radiological science and technology
    • /
    • v.40 no.2
    • /
    • pp.253-259
    • /
    • 2017
  • The study examines changes in calcium volume on born by comparing two figures; one is measured by dual energy computed tomography(DECT) followed by applying variation in monochromatic energy selection(keV), material decomposition(MD), and material suppressed iodine(MSI) analysis, and the other is measured by conventional single source computed tomography(CSCT). For this study, based on CSCT images taken by using human mimicked phantom, 70, 100, 140 keV and MSI, MD material calcium weighting(MCW) and MD material iodine weighting(MIW) of DECT were applied respectively. Then calculated calcium volume was converted to Agatston score for comparison. Volume of human mimicked phantom was in inverse proportion to keV. The volume decreased while keV increased(p<0.05). The most similar DECT volumes were reconstructed at 70 keV, the difference was showed $35.8{\pm}12.2$ for rib, femur ($16.1{\pm}24.1$), pelvis($13.7{\pm}18.8$), and spine($179.0{\pm}61.8$). However, the volume of MSI was down for each organ; the volume of rib was 5.55%, femur(76.34%), pelvis(55.16%) and spine(87.58%). The volume of MSI decreased 55.9% for rib, femur(80.7%), pelvis(69.6%) and spine(54.2%) while MD MIW reduced for rib(83.51%), femur(87.68%), pelvis(86.64%), and spine(82.62%). With the results, the study found that outcomes were affected by the method which examiners employed. When using DECT, calcium volume of born dropped with keV increased. It also found that the most similar DECT images were reconstructed at 70 keV. The results of experiments implied that the users of MSI and MD should be cautious of errors as there are big differences in scores between those two methods.

3D MDCT Reformation Findings of the Radiographic Contrast Medium Extravasation (조영제 혈관외유출 현상의 3D MDCT 재구성 영상)

  • Kweon Dae-Cheol;Kim Jeong-Koo
    • The Journal of the Korea Contents Association
    • /
    • v.6 no.5
    • /
    • pp.145-152
    • /
    • 2006
  • Radiographic contrast medium may cause tissue injury by extravasation during intravenous automated injection during CT examination. A large - volume extravasation (140 mL) occurred in an adult during contrast-enhanced CT The patient had a swelling and injury on the dorsum right hand of intravenous catheter region. The extravasation injury site was determined by CT scanning. The extavasation compartment syndrome case was examined using four separate display techniques. These 3D MDCT findings might help to determine the best course of treatment for patient with contrast extravasation. 3D image reconstructions provide accurate views of high-resolution and soft-tissue imaging. This paper introduces extravasation with the radiography and 3D MDCT findings.

  • PDF

A Method for Sinogram Interpolation for Reducing X-ray Dose (CT의 선량 감소를 위한 sinogram 보간 기법)

  • Kim, Jae-Min;Lee, Ki-Seung
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.37 no.7C
    • /
    • pp.601-609
    • /
    • 2012
  • In this paper, a limited-view CT image reconstruction method was studied to reduce the scan times and the X-ray dose for the patients. To reduce streak artifacts which is caused by insufficient number of views, we introduce a sinogram interpolation method based on image matching. Image matching is achieved using the characteristics of the neighboring views including intensity, gradient and distance between the pixels. Interpolation is performed using the image matching results.. A numerical phantom and Al-acryl phantom were used for evaluating the effectiveness of the proposed interpolation method. The results showed that streak artifacts were reduced in the reconstructed images while the details of the images were preserved. Moreover, maximum 5% improvements in terms of PSNR were observed.

CT Follow-Up of Postoperative Bronchopleural Fistula: Risk Factors for Progression to Chronic Complicated Infection (수술 후 기관지 흉막루의 전산화단층촬영 추적 검사: 만성 복합성 감염 진행의 위험인자 분석)

  • Ji-Yeon Han;Ki-Nam Lee;Yoo Sang Yoon;Jihyun Lee;Hongyeul Lee;Seok Jin Choi;Hye Jung Choo;Jin Wook Baek;Young Jin Heo;Gi Won Shin;Jinyoung Park;Dasom Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.82 no.1
    • /
    • pp.128-138
    • /
    • 2021
  • Purpose We evaluated the risk factors for progression to chronic complicated bronchopleural fistula (BPF) after pulmonary resection using follow-up CT. Materials and Methods We retrospectively reviewed 45 cases with BPF that had undergone pulmonary resection during 2010-2018. We compared the clinical and radiological characteristics of those with complicated BPF (n = 24) and those without complicated (sterilized) BPF (n = 21). The clinical and radiological risk factors for progression to chronic complicated BPF were examined by logistic regression analysis. Results The thickness of the pleural cavity wall (p = 0.022), the size of the pleural cavity (p = 0.029), and the size increase of BPF on follow-up (p = 0.012) were significantly different between the two groups. The risk factors for progression to chronic complicated BPF were age > 70 years (odds ratio, 6.43; 95% confidence interval, 1.2-33.7), the thickness of the cavity wall > 5 mm (odds ratio, 52.5; 95% confidence interval, 5.1-545.4), and an increase in the size of the pleural cavity on follow-up CT (odds ratio, 12.5; 95% confidence interval, 2.1-73.5), only in the univariate analysis. Conclusion The risk factors for progression to chronic complicated BPF can be evaluated using follow-up CT.

Performance Evaluation of YOLOv5s for Brain Hemorrhage Detection Using Computed Tomography Images (전산화단층영상 기반 뇌출혈 검출을 위한 YOLOv5s 성능 평가)

  • Kim, Sungmin;Lee, Seungwan
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.1
    • /
    • pp.25-34
    • /
    • 2022
  • Brain computed tomography (CT) is useful for brain lesion diagnosis, such as brain hemorrhage, due to non-invasive methodology, 3-dimensional image provision, low radiation dose. However, there has been numerous misdiagnosis owing to a lack of radiologist and heavy workload. Recently, object detection technologies based on artificial intelligence have been developed in order to overcome the limitations of traditional diagnosis. In this study, the applicability of a deep learning-based YOLOv5s model was evaluated for brain hemorrhage detection using brain CT images. Also, the effect of hyperparameters in the trained YOLOv5s model was analyzed. The YOLOv5s model consisted of backbone, neck and output modules. The trained model was able to detect a region of brain hemorrhage and provide the information of the region. The YOLOv5s model was trained with various activation functions, optimizer functions, loss functions and epochs, and the performance of the trained model was evaluated in terms of brain hemorrhage detection accuracy and training time. The results showed that the trained YOLOv5s model is able to provide a bounding box for a region of brain hemorrhage and the accuracy of the corresponding box. The performance of the YOLOv5s model was improved by using the mish activation function, the stochastic gradient descent (SGD) optimizer function and the completed intersection over union (CIoU) loss function. Also, the accuracy and training time of the YOLOv5s model increased with the number of epochs. Therefore, the YOLOv5s model is suitable for brain hemorrhage detection using brain CT images, and the performance of the model can be maximized by using appropriate hyperparameters.

THE ASSESSMENT OF ULTRASONOGRAPHIC ECHOGENICITY IN NORMAL HUMAN PAROTID AND SUBMANDIBULAR GLANDS (정상 이하선과 악하선에 대한 초음파영상의 반향성 평가)

  • Lee Jean;Park Tae-Won
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.27 no.1
    • /
    • pp.167-177
    • /
    • 1997
  • 타액선 병변의 일반적인 영상진단법으로는 타액선조영술, 전산화단층촬영술, 자기공명 영상, 타액선 스캔, 초음파 촬영술이 있다. 이중 초음파촬영술은 타액선내 종양의 유무를 평가하는데 있어서 매우 우수하여, 전산화단층촬영이나 자기공명영상과 더불어 이용되고 있으나, 염증을 진단하는데 있어서는 타액선조영술보다 민감도가 떨어지는 단점이 있다. 일반적으로 타액선의 염증반응시 초음파상은 반향이 정상보다 낮아지며, 내부의 균질성이 떨어지는 양상을 보여 이를 진단의 기준으로 이용해왔으나 정상타액선에서도 반향이 편차가 심할 뿐만 아니라 연령에 따른 정상 타액선의 반향성에 대한 연구가 부족하여 진단에 어려움이 있었다. 이에 저자는 우선적으로 타액선에 병적인 증상이 없는 남녀 90명을 연령별(20-35세 : 청년군, 36~55세 : 중년군, 55-70세 노년군),성별에 따라 분류하여 정상 타액선의 초음파상을 얻었다. 이의 반향을 측정하고, 비만한 정도를 나타내는 체격지수를 구하여 다음과 같은 결과를 얻었다. 1. 이하선과 악하선 모두에서 연령군극_ 따라 반향성이 증가하는 양상을 보였으며, 청년군과 노년군 사이에는 유의한 차이가 있었다(p<0.05). 2. 이하선과 악하선 모두에서 성에 따른 반향성의 유의한 차이는 없었다. 3. 성에 관계없이 악하선의 반향성이 이하선의 반향성보다 높았으며, 남자에 있어서는 유의한 차이가 있었다(p<0.05). 4. 동일한 타액선에서 좌우측 타액선의 반향성의 평균 차이값은 유의한 차이가 없었다. 5. 이하선과 악하선의 반향성은 중등도의 양의 상관관계를 보였다(남자 : r=0.56, 여자 : r=0.54). 6. 체격지수와 타액선의 반향성은 약한 양의 상관관계를 보였다.

  • PDF

상부기도 협착의 나선식 CT를 이용한 3차원 영상의 진단적 의의

  • 김승현;김현웅;노영수;임현준;윤대영
    • Proceedings of the KOR-BRONCHOESO Conference
    • /
    • 1997.04a
    • /
    • pp.119-119
    • /
    • 1997
  • 상부기도 협착의 원인은 장기간의 기관 삽관, 외상, 감염, 종양, 및 선천적인 결함등에 의해 존재하며, 이에 대한 진단은 단순 촬영이나 전산화 단층 촬영술 등으로 쉽게 진단은 가능하나, 적절한 치료 계획을 세우기 위해서는 그 범위 및 정도를 정확히 파악하는 일이 중요하다 최근 방사선 촬영기술의 발달로 현재의 2차원적 단면 영상에서 3차원적 영상으로 발전해왔으며 상부기도 협착 또한 3차원적 영상으로 진단하려는 노력이 시도되고 있다. 이에 저자들은 최근에 경험한 기관 협착증 7례에서 3D CT를 시행하여 협착 부위의 상태를 기존의 단순 촬영 영상 및 2D CT 영상과 비교하였고, 7례의 기관 협착증 중 4례에서 기관 단단 문합술 및 후두 기관 문합술을 시행한 바 수술시 확인된 협착 상태를 3D CT 영상과 비교하였다.

  • PDF

Type of medical institutions according to the Equipment List and inspection fee computed tomogaphy relationship between (의료기관 종별에 따른 전산화단층촬영장비 보유현황과 검사료간의 관계)

  • Kim, Min-Cheol;Lim, Cheong-Hwan
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2011.05a
    • /
    • pp.195-196
    • /
    • 2011
  • 1996년 이후부터 전산화단층촬영 검사가 건강보험급여대상이 되면서 이용률과 보급률이 더욱 증가되고 있으며 검사범위의 확대, 검사시간의 단축, 반복검사의 용이성, 이용의 편리성, 결과의 신뢰성, 장치의 구조적인 요소 및 검사 시행 횟수의 증가 등으로 검사량이 증가되고 있는 실정이다. CT 검사 건수의 증가요인으로 새로운 CT장비의 개발과 더불어 급격한 장비도입 증가 추세가 있으므로 이에 본 연구에서는 의료기관 종별 및 시기별 CT 장치 보유현황과 검사료간의 관계를 파악하였다. CT 장비는 병원급은 증가하고 있는 추세이나 의원급은 감소하고 있는 것으로 나타났다. CT진료비 청구는 80%이상이 종합전문요양기관과 종합병원에서 청구하는 것으로 나타났다. 이에 본 연구에서는 고가의료영상 진단 장비인 CT의 세대별 발달장비 도입 시기에 따른 우리나라 CT의 현황을 조사 분석하여 제시하여 고가의료장비 수급의 정책수립의 계기 및 기여하고자 한다.

  • PDF

Optimization of the Empirical Method to the Enhancement Image of the Four Chambers at the Same Time in the Pediatric Cardiac Computed Tomography (소아 심장 전산화단층촬영 검사에서 4 chamber의 동시 조영증강 영상에 대한 최적화 방안)

  • Park, Chanhyuk;Lee, Jaeseung;Im, Inchul
    • Journal of the Korean Society of Radiology
    • /
    • v.8 no.6
    • /
    • pp.279-285
    • /
    • 2014
  • This study is to have dose reduction and minimization of excessive use of contrast medium in the pediatric cardiac computed tomography and to suggest the optimization plan to acquire the enhancement image of the 4 chambers at the same time by formulating scan delay time in empirical method with considering variables such as contrast medium injection velocity and cardiac approaching time. Quantitative, qualitative and dose assessment were carried out for 30 pediatric patients who had taken the cardiac examination. In conclusion, image enhancement in 4 chambers of the cardiac shows over 300 HU which is proper to pediatric cardiac reading by applying the empirical method with calculating scan delay time according to weight and contrast medium volume and injection velocity. Qualitative image assessments in confidence sharpness and noise have excellence qualitatively. Exposure dose to pediatrics also decreases precisely. Therefore this study is judged to take a important role of making optimization images with advantages of dose reduction and less side effects caused by it's excessive use in clinic.