• Title/Summary/Keyword: 전산프로그램

Search Result 1,191, Processing Time 0.023 seconds

A Study on Analysis Method of Asphalt Plug Joint using FEM (유한요소 해석을 통한 Asphalt Plug Joint의 분석 방법에 대한 연구)

  • Moon, Kyoung-Tae;Park, Philip;Park, Sang-Yeol
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.31 no.2D
    • /
    • pp.237-245
    • /
    • 2011
  • Asphalt Plug Joint(APJ) is a new type of expansion joint that it's application are increased in USA as well as several European countries. APJ's' advantages are cheap construction and maintenance costs, and simple construction and securing of excellent flatness. However, APJ's usability is hindered because it showed a problem of premature failure. Research for solving this problem has been progressed, and FEM analysis among existing researches was peformed. However, the behavior of APJ was insufficiently analyzed and the reliability of the analysis was much low, since the material showing complicated behavior was oversimplified, Therefore, a material model was proposed and its effectiveness was confirmed by comparing it with actual behavior in order to improve the reliability of FEM analysis in this paper. ABAQUS program was used for FEM analysis, and an elasto-plastic model and a viscous-plastic model as the material model of APJ were suggested on the base of experiment results of APJ material performed by Bramel et al. The elasto-plastic model was defined by time-independent analysis since it didn't consider time and strain rate, and the viscous-plastic model was defined by time-dependent analysis since it considered. Influence of various elements affecting the behavior of APJ was investigated, and it was confirmed that the time-dependent analysis showed better result closed to actual behavior than the time-independent analysis.

A Study of the Fluidic Characteristics of High-Pressure Fuel Pumps for GDI Engines (GDI 고압펌프의 유동특성에 관한 연구)

  • Lee, Sangjin;Noh, Yoojeong;Liu, Hao;Lee, Jae-Cheon;Shin, Yongnam;Park, Yongduk;Kang, Myungkweon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.39 no.5
    • /
    • pp.455-461
    • /
    • 2015
  • A high-pressure fuel pump is a key component in a gasoline direct injection (GDI) engine; thus, understanding its flow characteristics is essential for improving the engine power and fuel efficiency. In this study, AMESim, which is a hydraulic analysis program, was used to analyze the performance of the high-pressure fuel pump. However, since AMESim uses a one-dimensional model for the system analysis, it does not accurately analyze the complicated flow characteristics. Thus, Fluent, computational fluid dynamics (CFD) software, was used to calculate the flow rates and net forces at the intake and discharge ports of the high-pressure fuel pump where turbulent flow occurs. The CFD analysis results for various pressure conditions and valve lifts were used as look-up tables for the AMEsim model. The CFD analysis results complemented the AMEsim results, and thus, improved the accuracy of the performance analysis results for the high-pressure fuel pump.

A Study on the Stress-Strain Prediction of Silty Clay (점성토(粘性土)의 응력(應力) - 변형(變形) 추정(推定)에 관(關)한 연구(硏究))

  • Cho, Seong Seup;Kang, Yea Mook;Chung, Seong Gyu;Yun, Hyun Chung
    • Korean Journal of Agricultural Science
    • /
    • v.19 no.1
    • /
    • pp.65-78
    • /
    • 1992
  • The paper describes the comparison between observed and predicted stress-strain characteristics of marine silty clay in Dangjin district. For prediction, the hyperbolic model which is applied the parameters acquiring by physical and triaxial compression test was adopted, and the obtained results were summarized as follows: 1. The Young's modulus were increased with decreasing of moisture contents and increasing of dry density. 2. The most affective factor to hyperbolic model is lateral stress and dry density. and than cohesion and internal friction angle. 3. The comparision between the statistical and hyperbolic values of maximum deviator stress have few accordance. and the statisticals is lower than the hyperbolics. 4. Without. much labor and tiresome procedures, effective computer program was made and applied, but technical procedure for prevents test errors of parameter calculation is importants.

  • PDF

Analysis of Gas-to-Liquid Phase Transformation of Hydrogen in Cryogenic Cooling Tube (초저온 냉각튜브 내 수소기체의 액체수소로의 상변환 분석)

  • Lee, Dae-Won;Nguyen, Hoang Hai;So, Myeong-Ki;Nah, In-Wook;Park, Dong-Wha;Kim, Kyo-Seon
    • Korean Chemical Engineering Research
    • /
    • v.56 no.1
    • /
    • pp.49-55
    • /
    • 2018
  • Under the era of energy crisis, hydrogen energy is considered as one of the most potential alternative energies. Liquid hydrogen has much higher energy density per unit volume than gas hydrogen and is counted as the excellent energy storage method. In this study, Navier-Stokes equations based on 2-phase model were solved by using a computational fluid dynamics program and the liquefaction process of gaseous hydrogen passing through a cryogenic cooling tube was analyzed. The copper with high thermal conductivity was assumed as the material for cryogenic cooling tube. For different inlet velocities of 5 m/s, 10 m/s and 20 m/s for hydrogen gas, the distributions of fluid temperature, axial and radial velocities, and volume fractions of gas and liquid hydrogens were compared. These research results are expected to be used as basic data for the future design and fabrication of cryogenic cooling tube to transform the hydrogen gas into liquid hydrogen.

The Effect of Oral Health Index and Dental Prosthesis Needs on Oral Health Related Quality of Life in Korean Elderly (한국 노인의 구강보건지수와 치과보철물 필요도가 구강건강관련 삶의 질에 미치는 영향)

  • Lee, Hee-Sung;Kim, Han-Gon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.1
    • /
    • pp.72-78
    • /
    • 2016
  • This study examined the oral health-related quality of life of the elderly using the oral health index and dental prosthesis status, and explored methods to improve the oral health status. The data collected from 'The fifth Korean national health and nutrition examination survey 2010' were analyzed. The subjects were 2273 elderly people, aged 65 years or older, who had completed an oral examination, health questionnaires and nutrition examination. Statistical analysis was done using the SPSS 22.0 for Windows. Frequency analysis, multiple regression analysis and structural equation model were used for statistical analysis. The general characteristics, oral health index and dental prosthesis showed differences in the subjective oral health status associated with as age, ST, FS-T, T-Health, maxillary crown needs, maxillary denture needs, mandibular denture needs, chewing status associated with the income level, FS-T, maxillary crown needs, maxillary denture needs, mandibular denture needs, speaking status associated with the ST, T-Health, maxillary implant status, and maxillary denture needs. In conclusion, both the oral health index and dental prosthesis needs affect the oral health related quality of life of the elderly. Governments should implement a variety of oral health programs and dental prosthesis policies to improve the quality of life related oral health of the elderly.

Numerical Experiment for the Estimation of Equivalent Resistance Coefficient for the Simulation of Inundation over Densely Populated Structures (구조물 밀집지역 범람수치모의를 위한 상당저항계수 산정 수치실험)

  • Kim, Hyeong-Seok;Choi, Jun-Woo;Ko, Kwang-Oh;Yoon, Sung-Bum
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.20 no.6
    • /
    • pp.532-539
    • /
    • 2008
  • Kwon et al.(2008) carried out a hydraulic experiment in order to evaluate Manning coefficient, which implicates flow resistance due to bottom friction as well as drag caused by the squared piers higher than water depth and arranged with equal intervals, under the flow condition with a constant drag coefficient, $Re>10^4$. And, based on the equation of equilibrium, they proposed a formula for the equivalent resistant coefficient including empirical drag interaction coefficient obtained by using the experimental results. In this study, the hydraulic experiment was simulated using FLOW-3D, a 3-dimensional computational fluid dynamic code. The computations were compared with the experiment results as well as the semi-theoretical formula, and the comparisons show a good agreement. From the agreement, it was confirmed that when flow resistance bodies were higher than water depth, Manning n value increases with 2/3 power of water depth as shown in the theoretical formula and that drag interaction coefficient was dominated by their intervals.

항만운영정보시스템의 데이터전송방식 개선에 관한 연구

  • 김칠호;박남규;최형림
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 1999.10a
    • /
    • pp.187-197
    • /
    • 1999
  • 해양수산부가 개발 .운영 중인 항만운영정보시스템(PORT-MIS)은 선박입출항 관련 업무, 수출입 화물 반출입에 관한 업무, 항만시설물관리에 관한 업무, 의사결정지원시스템에 관한 업무 등 크게 4개 업무오 구성되어 있으며, 총 19개의 전자문서와 1,500여개의 단위 프로그램으로 구성되어 있다. 그동안 PORT-MIS를 권역별로 확대 운영하면서 발생한 여러 가지 문제점들을 보완하기 위해 해양수산부와 정보통신부(한국전산원)가 공동으로 $\ulcorner$수출입화물 일괄처리시스템 구축$\lrcorner$ 용역 사업을 현재 진행 중에 있다. 본 연구는 용역과업 내용에 포함되어 있지 않으면서 개선이 필요한 외항선(국전선.외국전선 포함) 선박입항보고서(최초.변경.최종)와 선박출항보고서(최초.변경.최종), 내항선입.출항신고서, 예선사용허가신청서 및 지정서, 도선사용허가신청서 및 지정서 등의 민원업무를, 사용자로 하여금 최소한의 노력으로 처리할 수 있도록 제출방법을 개선(EDI방식에서 온라인방식으로)하여 행정소요시간을 단축함으로써 PORT-MIS의 효율성을 높일 수 있는 방안을 제시하고자 한다. 이러한 노력을 통해 PORT-MIS EDI업무가 개선되어 선박입.출항보고를 1회롤 처리할 수 있다면 연간 29만9천건의 서류절감으로 약 1억3천7백만원의 물류비를 줄일 수 있으며, 시간 단축에 따른 간접비용을 계산하면 보다 많은 효과가 있다고 판단된다. 그리고 내항선입.출항신고서 및 예.도선업무를 EDI방식에서 온라인방식으로 전환함으로써 선사와 예선업체 및 도선사협회가 대화형식으로 업무처리가 이루어져 분쟁을 최소화 할 수 있다면, 전자문서 31만6천건/년 절감으로 1억3백만원/년의 예산이 절감될 것으로 예상된다.rr로 변화시켰고 inductive power는 200~800watt, bias voltage는 0~-200voltage로 변화시켰으며 식각마스크로는 SiO2를 patterning 하여 사용하였다. n-GaN, p-GaN 층 이외에 광소자 제조시 필수적인 InGaN 층을 100% Cl2로 식각한 경우에 InGaN의 식각속도가 GaN에 비해 매우 낮은 식각속도를 보였다. Cl2 gas에 소량의 CH4나 Ar gas를 첨가하는 경우와 공정압력을 감소시키는 경우 식각속도는 증가하였고, Cl2/10%Ar 플라즈마에서 공정 압력을 감소시키는 경우 식각속도는 증가하였고, Cl2/10%CHF3 와 Cl2/10%Ar 플라즈마에서 공정압력을 15mTorr로 감소시키는 경우 InGaN과 GaNrks의 선택적인 식각이 가능하였다. InGaN의 식각속도는 Cl2/Ar 플라즈마의 이온에 의한 Cl2/CHF3(CH4) 플라즈마에서의 CHx radical 형성에 의하여 증가하는 것으로 사료되어 진다.$ 이상을 나타내었다. 박막의 Sn/In atomic ratio는 0.12, O/In의 비율은 In2O3의 화학양론적 비율인 1.5보다 작은 1.3을 나타내었다.로 보인다.하면 수평축과 수직축의 분산 장벽의 비에 따라 cluster의 두께비가 달라지는 성장을 볼 수 있었고, 한 축 방향으로의 팔 넓이는 fcc(100) 표면의 경우 동일한 Ed+Ep값에 대응하는 팔 넓이와 거의 동일한 결과가 나타나는 것을 볼 수 있다. 따라서 이러한 비대칭적인 모양을 가지는 성장의 경우도 cluster 밀도, cluster 모양, cluster의 양 축 방향 길이 비, 양 축 방향의 평균 팔 넓이로부터 각 축 방향의 분산 장벽을 얻어낼 수 있을 것으로 보인다. 기대할 수 있는 여러

Antimicrobial resistance rates changes according to the amount of the antimicrobial agent in clinically important strain isolated from blood cultures (혈액배양에서 분리된 임상적 주요 균주의 항균제사용량에 따른 내성률 변화)

  • Kim, Jae-Jung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.5
    • /
    • pp.653-659
    • /
    • 2016
  • The purpose of the study is to investigate the correlation between the amount of antimicrobial agent (Defined Daily Dose, DDD) and antimicrobial resistance rate (%). The treatment of infectious diseases is becoming increasingly difficult, due to the increase in the number of multi-drug resistant bacteria, making it a clinically significant problem. Among the various factors, antimicrobial abuse is a major cause of antimicrobial resistance. The study was conducted on inpatients in a secondary university hospital in the central region utilizing the hospital's computerized statistical data and microbiological program of laboratory medicine from January 2010 to December 2014 pertaining to the dose of antimicrobial drugs for Acinetobacter baumannii, Pseudomonas aeruginosa, Klebsiella pneumoniae, and Escherichia coli strains isolated from blood culture. We analyzed the antimicrobial resistance rate per dose with the Pearson correlation coefficient. A significant (positive?) correlation was detected between the cefepime dose and the resistance of E. coli (P<0.033; r=0.907), while a significant negative correlation was found between the tobramycin dose and the resistance of E.coli. (P<0.028; r=-0.917). The aminoglycoside resistance of A. baumannii showed a significant negative correlation (P<0.048; r=-0.881), and the aminoglycoside resistance of E. coli showed a significant negative correlation as well (P<0.001; r=-0.992). In conclusion, the amount of antimicrobial agent (Defined Daily Dose, DDD) (is partly related to) the bacterial strain and its antimicrobial resistance rate (%).

The Metacognition, Self-efficacy and Self-leadership among Nursing Students (간호대학생의 메타인지, 자기 효능감 및 셀프리더십)

  • Wang, Heejung;Jung, Sun-A;Park, Hyo-Eun;Yoo, Hye-Sook;Bae, Yeonhee;Kim, Jiyoung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.9
    • /
    • pp.619-627
    • /
    • 2016
  • This study was conducted to identify the relationship between metacognition, self-efficacy and self-leadership among nursing students, and to investigate the factors influencing self-leadership. The subjects of this study consisted of 445 nursing students of S university in S city. Data were collected using self-reported questionnaires from May 23 to June 10 and analyzed based on frequencies, t-tests, ANOVA, Scheffe's test, Pearson's correlation, and multiple regression, which were conducted using the IBM SPSS 21.0 program. The mean value of self-leadership was 3.54, which was significantly positively correlated with metacognition (r=0.670, p<0.001) and self-efficacy (r=0.742, p<0.001) in nursing students. Self-efficacy, metacognition, religion and satisfaction of their major explained 62.2% of the total variance in self-leadership among nursing students ($R^2=0.622$, p<0.001). Overall, self leadership should be strengthened by increasing the self-efficacy and metacognition of nursing students.

A Study on Numerical Analysis for Internal PEMFC Cooling of Power Pack for UPS (UPS 파워 팩 내부 연료전지의 냉각특성에 대한 수치 해석)

  • Song, Jun-Seok;Kim, Byeong-Heon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.4
    • /
    • pp.527-535
    • /
    • 2017
  • Heat management is one of the most critical issues in Polymer Electrolyte Membrane Fuel Cells (PEMFCs) installed inside the fuel cell power pack of a fuel cell battery hybrid UPS. If the heat generated by the chemical reaction in the fuel cell is not rapidly removed, the durability and performance of the fuel cell may be affected, which may shorten its lifetime. Therefore, the objective of this study is to select and propose a proper cooling method for the fuel cells used in the fuel cell power pack of a UPS. In order to find the most appropriate cooling method, the various design factors affecting the cooling performance were studied. The numerical analysis was performed by a commercial program, i.e., COMSOL Multiphysics. Firstly, the surface temperature of the 1 kW class fuel cell stack with the cooling fans placed at the top was compared with the one with the cooling fans placed at the bottom. Various rotation speeds of the cooling fan, viz. 2,500, 3,000, 3,500, and 4,000 RPM, were tested to determine the proper cooling fan speed. In addition, the influence of the inhaled air flow rate was investigated by changing the porous area of the grille, which is the entrance of the air flowing from the outside to the inside of the power pack. As a result, it was found that for the operating conditions of the 1 kW class PEMFC to be acceptable, the cooling fan was required to have a minimum rotating speed of 3500 RPM to maintain the fuel cell surface temperature within an acceptable range. The results of this study can be effectively applied to the development of thermal management technology for the fuel cells inside the fuel cell power pack of a UPS.