• Title/Summary/Keyword: 전산소화

Search Result 32, Processing Time 0.028 seconds

Optimal Design of the Safety Valve by Response Surface Method (반응표면법을 이용한 안전밸브의 최적화)

  • Lee, Sang-Woo;Shin, Dae-Young;Byun, Cheol-Woong
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.20 no.5
    • /
    • pp.551-556
    • /
    • 2007
  • High pressure storage of the agent gas in fire suppression system was composed of tank, main valve and safety valve, which prevents the fracture of the high pressure storage. The safety valve has circular thin plate as fracture plate that was destroyed over fracture pressure. When inner pressure of the storage is reached the fracture pressure, the safety valve discharges gas and degrades simultaneously the inner pressure of the storage. There are design variables such as flow path diameter, inner diameter of the plastic packing ring, thickness of plate and fillet radius. In this variables, thickness of plate is set to be a value of 0.2mm. The main effect of variables on the inner pressure, has been decided using factorial design and statistical analysis. Therefore, the relation of variables are expressed by regression equation. It is disclosed results that the difference of fracture pressures between the equation and experiment has $2{\sim}5%$. Finally, using response surface method, the optimal design of the safety valve could be decided with safety pressure of 25MPa, where the fracture occurs on circular thin plate.

Study of Necessity of Advanced Integrated Digital Engineering and Management Tools (선진통합형 디지털 엔지니어링 및 경영 도구의 필요성 연구)

  • Luke (Yang Ouk) Kim;Kyung Ho Lee
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.36 no.1
    • /
    • pp.27-38
    • /
    • 2023
  • How the port, shipping, shipbuilding, and vender industries in Korea can have a seamless value chain through their digitally smooth cooperation by applying the latest information and communications technology through the "4th industrial revolution" was examined. Also considered was the proposition that the value chain should be a smart, seamless value chain among industries with successful hyperconnection. Their cooperative relationships were defined, and the crucial elements for the sustainable development of these industries were considered. As a result, the direction for achieving environmental, social, and governance management by realizing decarbonization through today's digitalization could be studied. In particular, the importance of digitization as a way to respond to the future market from the perspective of small and medium-sized enterprises and the role of digitization realized by small and medium-sized equipment companies in the overall industry were examined. The results simultaneously show the state of linkage between industries and the reason why the value chain must maintain a smooth relationship. In addition, using the lessons learned from recent failure cases from the Korean shipbuilding industry as a cornerstone, the direction for creating a strategic pathway for intelligent connection was investigated.

COMPUTATIONAL SIMULATION OF FIRE SUPPRESSION SYSTEM FOR CABINS OF SHIPBOARD ENCLOSURE (선박 거주구역용 소화시스템의 전산 시뮬레이션)

  • Jung, I.S.;Chung, H.T.;Han, Y.S.
    • Journal of computational fluids engineering
    • /
    • v.21 no.4
    • /
    • pp.40-45
    • /
    • 2016
  • The numerical simulation has been performed to predict the performance of the fire suppression system for cabin of shipboard enclosure. The present study aims ultimately at finding the optimal parametric conditions of the mist-injecting nozzles using the CFD methods. The open numerical code was used for the present simulation named as FDS (Fire Dynamics Simulator). Application has been done to predict the interaction between water mist and fire plume. In this study, the passenger cabin was chosen as simulation space. The computational domains for simulation in the passenger cabin were determined following the fire scenario of IMO rules. The full scale of the flow field is $W{\times}L{\times}H=4{\times}3{\times}2.4m^3$ with a dead zone of $W{\times}L{\times}H=1.22{\times}1.1{\times}2.4m^3$. The water mist nozzle is installed in ceiling center of 2.3 m height from the floor, and there are six mattresses and four cushions in the simulation space. The combination patterns of orifices to the main nozzle and the position to install nozzles were chosen as the simulation parameters for design applications. From the present numerical results, the centered-located nozzles having evenly combined orifices were shown as the best performance of fire suppression.

A study on Installation of Facility Monitoring System in Computer Room's (전산실 기반설비감시시스템 구축에 관한 연구)

  • Choi, Woo-hyoung;Kim, Chang-soo
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2013.05a
    • /
    • pp.159-161
    • /
    • 2013
  • Surveillance system that can respond quickly in case of failure to detect various disorders that can occur for a temperature chamber, and fire extinguishing equipment, such as UPS, communication room, and computer room of enterprises and institutions operating in infrastructure, and to systematically study. Major telecommunications equipment and computational facilities to manage, operating in an environment of air conditioners work status, distribution panel and the UPS status and fault status, rapid notification system in case of fire is needed. By identifying the status and problems of disability surveillance on the periphery of the existing computer room's infrastructure management guidelines presented in the next future Conception and systematic surveillance system for staff to refer to when designing considerations associated with data center monitoring system the necessity of the various studies are presented.

  • PDF

A Study for the Fire Hazard Evaluation through the Fire Simulation of an Apartment Fire Accident (아파트 화재 사례 전산모사를 통한 화재위험성 평가에 관한 연구)

  • Jeon, Heung-Kyun;Choi, Young-Sang;Choo, Hong-Lok
    • Fire Science and Engineering
    • /
    • v.24 no.4
    • /
    • pp.69-78
    • /
    • 2010
  • In this study, Fire Hazards were evaluated through computer simulation using FDS program for an apartment fire accident. The results of fire simulation showed that the maximum heat release rate in the case of no sprinklers activation was 7,700 kW which was about 16 times of that in the case of sprinklers activation, 497 kW and there was a very high fire hazard due to the backdraft phenomenon when the door of fire room was forced to open. Regarding the hazard time of fire room temperature and detection time of detectors, available evacuation time was 32.5 seconds of minimum to 53.5 seconds of maximum. In the case of sprinklers activation, fire hazard in the apartment was showed to be very low due to the fire control by the spray cooling of sprinklers. This study shows that what a important function for fire safety is the activations of fire sprinkler system and emergency alarm system and what a large loss can cause if these systems don’t activate in fire accidents.

Related Factors to Visual Display Terminal Syndrome in Employees of A General Hospital in one Metropolitan City (일개 광역시 종합병원 근로자의 VDT 증후군 자각증상에 대한 관련요인 연구)

  • Yu, Se-Jong;Hong, Jee-Young;Lee, Moo-Sik;Na, Baeg-Ju
    • Proceedings of the KAIS Fall Conference
    • /
    • 2010.05b
    • /
    • pp.863-866
    • /
    • 2010
  • 병원 근로자의 VDT 자각 증상에 대한 선행연구를 보면 대부분이 간호사 관련 직종으로 한정되어 있고, 방사선사에 대한 연구는 수행되지 않았다. 본 연구는 2009년 10월 15일부터 11월 2일까지 대전광역시에 소재하고 있는 종합병원에 VDT 작업을 시행하는 보험심사, 원무, 의무기록, 전산, 행정부서 근무자와 방사선사를 대상으로 구조화된 설문지를 활용하여 분석하였다. VDT 증후군 자각 증상 점수를 종속변수로 한 다중선형회귀 분석 결과 관련요인으로 안관련 증상에 영향을 미치는 요인을 보면 성별, 건강염려, 일상생활 방해이며, 전신증상은 운동, 스트레스, 건강상태 인지 관련, 근골격 증상에서는 임상경력 6-10년, 대인관계, 건강상태 인지 관련 건강염려와 일상생활 방해로 나타났으며, 통계적으로 유의한 차이를 보였다. 피부 증상으로는 연령 20-29세, 결혼여부, 식습관, 건강상태 인지 관련 소화 정도와 일상생활 방해로 나타났으며, 심리 증상으로는 성별, 결혼 여부, 스트레스, 소화 정도, 일상생활 방해로 나타났으며, 통계적으로 유의한 차이를 보였다. 타부서 근로자와 방사선사의 VDT 증후군 자각점수 차이가 크게 나타나지 않았으며, 이는 방사선사의 업무가 VDT 환경으로 변함으로써 VDT 증후군 자각 증상이 일어날 수 있다는 것을 나타내는 것이다. 이는 정기적인 순환근무를 시행함으로써 VDT 환경에 지속적인 노출을 피하는 것이 예방 대책이라 할 수 있다.

  • PDF

Audit of Appropriateness of Fresh Frozen Plasma Transfusion (신선동결혈장의 적정수혈 분석)

  • Seo, Youkyung;Kim, Moon Jung;Kim, Sinyoung;Kim, Hyun Ok
    • The Korean Journal of Blood Transfusion
    • /
    • v.23 no.2
    • /
    • pp.136-144
    • /
    • 2012
  • Background: Fresh frozen plasma (FFP) transfusion is administered primarily for management of acquired bleeding disorders. However, in practice, FFP transfusion is increasing without a solid rationale. Methods: We conducted an audit to evaluate the appropriateness of the indications for FFP transfusion during the period from July 2010 through June 2011. Assessment of the appropriateness of the indications was based on the national transfusion guidelines and the transfusion criteria promulgated by the Severance Hospital. Results: In total, 17,733 units of plasma were transfused to 1,949 patients over 4,982 events. We found that administration of FFP was not in compliance with the recommended guidelines in 1,990 events. The number of total FFP transfusions was higher in medical departments (Gastroenterology) than in surgical departments (Thoracic and cardiovascular surgery, General surgery). However, the proportion of cases of inappropriate transfusion was higher in surgical departments than in medical departments. Both the total number of FFP transfusion and the proportion of inappropriate transfusion were high in patient with neoplasm, disease of the digestive system, and diseases of the circulatory system. Conclusion: Continuous monitoring on appropriateness for FFP transfusion and feedback to the physician are critical in securing the transfusion safety as well as maintaining the quality of FFP transfusion. New-found indication for FFP transfusion should be investigated and applied in timely manner.

GEOMETRIC NINLINEAR ANALYSIS OF UNERGROUND LAMINATED COMPISITE PIPES (기하학적 비선형을 고려한 지하매설 복합재료 파이프의 해석)

  • 김덕현;이인원;변문주
    • Computational Structural Engineering
    • /
    • v.2 no.1
    • /
    • pp.65-70
    • /
    • 1989
  • An analytical study was conducted using the Galerkin technique to determine behaviour of thin fibrereinforced and laminated composite pipes under soil pressure. Geometric nonlinearity and material linearity have been assumed. It is assumed that vertical and lateral soil pressure are proportional to the depth and lateral displacement of the pipe respectively. It is also assumed that radial shear stress is negligible because the ratio of thickness to the radius of pipe is very small. The above results are verified by the finite element analysis.

  • PDF

A Study on Neutron Shielding Capability Assessment of Metallic Hydride using Cf-252 Neutron Source (Cf-252 중성자 선원을 이용한 수소화금속의 중성자 방사선 차폐능 평가)

  • Yoo, Beong-Gyu;Kim, Keung-Sik;Kim, Yong-Soo
    • Journal of radiological science and technology
    • /
    • v.26 no.3
    • /
    • pp.51-57
    • /
    • 2003
  • Mitigation of fast neutron irradiation damage on reactor vessel and improvement of mechanical integrity are desired for the successful plant life-time extension. In this study, the performance of metallic hydride for this application is reviewed and compared. First, selected prospective metallic hydrides are evaluated by MCNP code and put into the attenuation test using Cf-252 neutron source. Since for the reactor application high moderation and reflection with no absorption are favored, Z factor is introduced for the evaluation. According to the Z value estimation $ZrD_2$ and $TiD_2$ are turned out to be the most favorable fast neutron shielding materials. More thorough evaluation by computer simulation and experimentally, will be followed.

  • PDF

Activities to Reduce the number of No-Show Patients with Colonoscopy appointments (대장내시경 검사 부도관리를 위한 개선활동)

  • Kwon, Oh-Ryoun;Lee, Jung-Sun;Na, Eun-Shim;Kim, Hoon
    • Quality Improvement in Health Care
    • /
    • v.15 no.1
    • /
    • pp.89-100
    • /
    • 2009
  • 문제: 소화기병검사실에서 대장내시경 검사의 부도건수가 최근 월 200명 정도로 예약인원의 16%에 달한다. 이는 본원 외래진료 부도율이 평균 10%인 것과 비교할 때 상당히 높은 결과이므로 대장내시경 예약환자를 대상으로 부도율 관리를 위한 활동이 필요하였다. 목적: 외래 및 입원환자의 부도건수 및 부도환자의 특성을 분석하고, 개선활동을 통하여 대장내시경 검사의 부도율을 줄인다. 의료기관: 서울 아산병원. 질 향상 활동: 부도관리를 위한 개선활동으로 SMS 횟수를 2주전, 4일전, 1일전 3회로 변경하고, 내용도 각 시기마다 차별화하였다. 대장내시경 검사 예약을 하고 기다리는 환자를 대상으로 처방일 순, 예약 날짜순서 등 필요한 항목 순으로 볼 수 있는 리스트가 필요하여 예약대기 프로그램을 개발하였고, 처방일로부터 2주 이내 자동예약을 금지하였다.(7월 10일부터 시작) 예약대기명단에 있는 환자를 대상으로 전화로 예약 변경을 하여 2주 이내에는 예약의 빈자리가 없도록 하였다. 미리 부도를 예측하여 추가로 예약하던 방법에서 정원조정을 하여 정원 외 추가 예약을 하지 않았다. 입원환자 일정관리를 위하여 일정관리 프로그램을 개발하여 타과의뢰 회신을 하는 전임의가 직접 날짜를 전산에 입력하여 회신과 동시에 검사실, 담당주치의, 담당 간호사가 모두 일정을 확인할 수 있도록 하였으나 프로그램이 늦어져 9월 12일부터 시행하였다. 개선효과: 부도건수가 개선 전 8주 동안 385건(예약인원 대비 16%) 에서 개선 후 6주의 평가기간 동안 256건(예약인원대비 14.1%)으로 129건이 감소하였으며, 검사 1-2일전 일정 변경 연락 환자 감소 및 검사 비용 수납 환자의 부도건수가 감소하였다. 대장내시경 검사 예약대기 프로그램 운영 및 예약 변경 전화 활동으로 2달씩 기다리던 환자의 예약일을 약 한 달 정도 단축하여 줄 수 있었다. 검사 정원 관리의 결과로 검사 예약 시 예약기준이 명확해지고, 부적절한 예약으로 인한 검사지연 등이 확실히 줄었다. 또한 입원환자 일정관리 프로그램 적용으로 입원환자의 검사일정과 관련된 전화업무는 확실히 줄어들 것으로 예상된다.

  • PDF