• Title/Summary/Keyword: 전산모사 실험

Search Result 280, Processing Time 0.022 seconds

The Verification of Computer Simulation of Nitinol Wire Stent Using Finite Element Analysis (유한요소법을 이용한 나이티놀 와이어 스텐트의 전산모사 실험 데이터 검증)

  • Kim, Jin-Young;Jung, Won-Gyun;Jeon, Dong-Min;Shin, Il-Gyun;Kim, Han-Ki;Shin, Dong-Oh;Kim, Sang-Ho;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.20 no.3
    • /
    • pp.139-144
    • /
    • 2009
  • Recently, the mathematical analysis of stent simulation has been improved, with the help of development of various tool which measure mechanical property and location of stent in artery. The most crucial part of the stent modeling is how to design ideal stent and to evaluate the interaction between stent and artery. While there has been great deal of researches on the evaluation of the expansion, stress distribution, deformation of the stent in terms of the various parameters, few verification through computer simulation has been performed about deformation and stress distribution of the stent. In this study, we have produced the corresponding results between experimental test using Universal Testing Machine and computer simulation for the ideal model of stent. Also, we have analyzed and compared stress distribution of stent in the cases of that with membrane and that without membrane. The results of this study would provide minimum change of plan and good quality for ideal stent replacing damaged artery through the analysis using computer simulation in the early stage of stent design.

  • PDF

Measurement of Power and frequency in the Axially Extracted Virtual Cathode Oscillator by diode condition

  • 정민우;최명철;최성혁;안정철;조태승;김진구;조대식;임재용;김태영
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 1999.07a
    • /
    • pp.247-247
    • /
    • 1999
  • 새로운 형태의 고출력 마이크로웨이브 발진장치인 가상 음극 발진기(Virtual Cathode Oscillator)를 이용하여 음극(Cathode)의 크기를 변화시켜 가면서 출력을 측정하였다. 측정된 출력을 전산모사의 결과를 토대로 재해석하였고, 우리가 보유한 천둥 장치에서의 최고출력을 얻을 수 있는 음극 크기를 측정하여 전사모사의 결과와 비교를 하였고, 그에 따른 주파수를 계산을 하고 전산모사를 통해 확인하였다. 본 실험을 하기 위해 본 실험실이 제작한 천둥 장치의 조건(300kV, 20kA)을 사용하였고, 음극은 탄소를 사용하였고, 전자빔의 형탠는 Solid 빔을 사용하였다. 전에 발표했던 전산모사 내용을 실험을 통해 파원(~수 GW)와 에너지 변환효율(~10%), 그리고 주된 동작 주파수등을 계산했다. 본 실험실이 보유한 천등 장치에서 수 GW급의 출력을 얻기 위해 입력 전압에 따른 변화를 전산모사하였다. 이와같은 가상 음극 형성을 위한 다이오드 구조에 따른 Vircator 출력의 경향을 관찰하였다.

  • PDF

음극 크기에 따라 가상 음극발진기를 이용한 고출력 마이크로파 발생 및 진단

  • 정민우;최명철;최성혁;조광섭;서윤호;최은하;엄환섭;신희명
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2000.02a
    • /
    • pp.179-179
    • /
    • 2000
  • 음극의 크기에 따라 발생된 전자빔 전류가 도파관 영역에서 공간 전하 한계 전류를 초과할 경우 형성되는 가상 음극 (Virtual Cathode)을 이용한 축 방향으로의 고출력 마이크로파 발생 및 진단에 관한 연구를 수행하였다. 먼저 실험에 앞서 전산모사를 통해 결과를 예측하고 실험을 통해 확인하는 순으로 하였다. 전산 모사는 2-1/2차원 Partical-In-Cell(PIC) 코드인 "MAGIC"을 사용하여 축 방향으로 진행하는 새로운 개념의 가상 음극발진기를 모사하고, 정확한 경과를 얻기 위해 강렬한 상대론적 전자빔 발생 장치인 "천둥"( 최대 전압 600kV, 최대 전류 70KA, 60ns)을 사용하여 전산 모사에 넣어줄 전류값을 얻었다. 음극의 반지름이 2.5cm 일 때 전파되는 최대 출력이 약 800MW인 마이크로파가 발생되었고, 이때 출력변환 효율이 약 30%임을 전산모사를 통하여 알 수 있었다. 또한 전파하는 전기장의 축방향 성분(Ez)의 반지름 방향에 대한 분포 특성을 통하여 주된 전파 모드가 TM01와 그 상위모드의 조합으로 이루어졌음을 알았고 이때 기대되는 동작 진동수는 5~7 GHz임을 전산 모사 결과로부터 알 수 있었다. 실험을 통해서도 음극의 크기가 2.5cm 때, 최대 출력이 약 520MW인 마이크로파를 발생하였고, 이 때 출력 변환 효율은 약 8%이고, 방전 사진을 통해서 주된 동작 모드가 TM01와 그 상위모드의 조합으로 이루어졌음을 알았고, 이때 주된 출력 진동수는 5~6 GHz임을 알 수 있었다.는 5~6 GHz임을 알 수 있었다.

  • PDF

Experimental and FEMLAB Simulation Study of Ibuprofen Racemate Separation in HPLC (Ibuprofen Racemate의 HPLC 분리실험과 FEMLAB 전산모사 연구)

  • Lee, Eun;Chang, Sang-Mork;Kim, Jong-Min;Kim, Woo-Shick;Kim, In-Ho
    • KSBB Journal
    • /
    • v.21 no.3
    • /
    • pp.224-229
    • /
    • 2006
  • FEMLAB is a powerful interactive environment for modeling, solving all kinds of scientific and engineering problems based on partial differential equations(PDEs). Separation process of chiral compound in HPLC columns was simulated by FEMLAB. To study change of elution profile with isotherm models, non-competitive and competitive Langmuir adsorption isotherm were adopted. Separated material was (R, S)-ibuprofen [(R, S)-2-(4-isobutyl phenyl) propionic acid], an anti-inflammatory agent, which retain the pharmacological activity in the (S)-(+)-enantiomer. Sample concentrations were changed from 0.5 mg/ml to 2.0 mg/ml at a flow rate of 1 ml/min and flow rate varied from 1 ml/min to 3 ml/min at an ibuprofen concentration of 2.0 mg/ml and $20{\mu}l$ of injection volume. Simulated results were well fitted with experimental data.

원자력재료의 건전성 평가를 위한 전산모사

  • Lee, Gyeong-Geun;Jang, Geun-Ok;Gwon, Jun-Hyeon
    • Journal of the KSME
    • /
    • v.55 no.10
    • /
    • pp.40-44
    • /
    • 2015
  • 이 글에서는 원자력구조재료에서 발생하는 조사손상에 대하여 간략히 기술하고, 조사손상실험의 대안으로 고려되고 있는 전산모사 기법에 대하여 그 종류와 특징을 개괄적으로 서술하였다.

  • PDF

Monte Carlo simulation for the transport of ion in matter (물질내의 이온수송에 대한 Monte Carlo 전산모사)

    • Journal of the Korean Vacuum Society
    • /
    • v.5 no.4
    • /
    • pp.292-300
    • /
    • 1996
  • The scattering of incident ions and target atoms in the amorphous solid matters are calculated by Monte Carlo simulation method. The experimentally derived universal scattering cross-section of Kalbitzer and Oetzmann is used to describe nuclear scattering. For electronic energy loss, the Lindhard-Scharff and Bethe formula are used. Comparing the ion scattering formulas and ranges with the known results of experiment and other programs, we find our results are good agreement with others.

  • PDF

Kinetic Analysis of Energetic Materials Using Differential Scanning Calorimetry (DSC를 이용한 고에너지 물질의 반응속도식 추출과 활용)

  • Kim, Yoocheon;Park, Jungsoo;Yang, Seungho;Park, Honglae;Yoh, Jai-Ick
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.19 no.1
    • /
    • pp.33-41
    • /
    • 2015
  • The kinetic analysis of energetic materials using Differential Scanning Calorimetry (DSC) is proposed. Friedman Isoconversional method is applied to DSC experiment data and AKTS software is used for analysis. The proposed kinetic scheme has considerable advantage over the standard method based on One-Dimenaionl Time to Explosion (ODTX). Reaction rate and product mass fraction simulation are conducted to validate extracted kinetic scheme. Also a slow cook-off simulation is implemented on $B/KNO_3$ for validating the applicability of the extracted kinetics scheme to a practical thermal experiment.

An Extraction of Detailed Isoconversional Kinetic Scheme of Energetic Materials using Isothermal DSC (등전환법과 등온 DSC를 이용한 고에너지 물질의 정밀 반응모델 개발)

  • Kim, Yoocheon;Park, Jungsu;Kwon, Kuktae;Yoh, Jai-ick
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.20 no.2
    • /
    • pp.46-55
    • /
    • 2016
  • The kinetic analysis of a heavily aluminized cyclotrimethylene-trinitramine(RDX) is conducted using differential scanning calorimetry(DSC), and the Friedman isoconversional method is applied to the DSC experimental data. The pre-exponential factor and activation energy are extracted as a function of the product mass fraction. The extracted kinetic scheme does not assume multiple chemical steps to describe the complex response of energetic materials; instead, a set of multiple Arrhenius factors is constructed based on the local progress of the exothermic reaction. The resulting reaction kinetic scheme is applied to two thermal decomposition tests for validating the reactive flow response of a heavily aluminized RDX. The results support applicability of the present model to practical thermal explosion systems.

Computational Analysis of Vortex Structures around Wall-Mounted Bluff Body in Boundary Layer (경계층 내에 위치한 각진 물체 주위의 와류 전산 해석)

  • Lee, Ju-Yong;Kim, Hyeon-U;Lee, Seung-Su
    • Proceeding of EDISON Challenge
    • /
    • 2013.04a
    • /
    • pp.354-359
    • /
    • 2013
  • 일반적으로 건축물의 설계시 풍동 실험을 통한 풍환경의 평가를 수행하고 있으며, 이는 환경 영향 평가법에서 정한 건축 사업 시행 시 수반되어야 할 자연환경, 생활환경 그리고 사회경제환경의 영향 평가의 일환으로 실시되고 있다. 그러나, 풍동 실험의 경우 여러 가지 현실적 제약조건으로 설계와 실험의 피드백 (Feedback)이 원활하지 못하며, 특히 대상 건축물이 공장과 같이 대기 오염원이 되는 경우 실험은 더욱 어려운 형편이다. 이에 대한 보완책으로 전산 유체 역학을 이용한 건축물의 풍압 해석에 의한 풍하중 추정이나 인접 지형-지물의 영향을 고려한 건축물 주위의 풍환경 평가가 있다. 전산 모사에 의해 풍동 실험의 미비점을 보완하고, 보다 상세한 정보를 확보함으로써 건축물의 구조적 안전성의 증대와 환경 피해 감소를 기할 수 있다. 그러나 복잡한 지형-지물이나 건축물 주위의 풍환경에 대한 전산 모사는 주로 두 가지의 기술적 어려움을 수반하게 되다. 그 중 하나는 고정 경계면을 이루는 형상의 복잡성으로 인해 기존에 많이 이용하고 있는 Body-fitted 격자계를 이용하는 경우, 격자 생성 과정이 매우 복잡하고 어려울 뿐 만 아니라 생성된 격자가 주로 비정렬 (unstructured) 특성을 갖게 되어 수치해석 과정의 효율을 저하시키는 요인이 되며, 격자의 형상도 수치해석의 수렴성을 저하시키는 예가 많다. 다른 어려움으로 풍환경은 전형적인 난류 유동장으로서 난류의 전산 해석은 아직도 해결하지 못한 부분이 많다는 점이다. 이에 본 논문에서는 복잡한 지형-지물이나 건축물의 풍하중과 풍환경의 전산 모사 기술 확보를 위하여 수행중인 연구의 일환으로 물체 형상의 기하학적 복잡성의 극복을 위한 가상경계법 (Immersed Boundary Method)과 난류 유동장의 물리적 엄밀성을 높이기 위한 다와동 모사 (Large Eddy Simulation)을 이용한 물체 형상과 무관한 유동장 해석 기술 개발에 대하여 다루고자 한다. 먼저 최근에 유동 해석에 이용되는 방법인 가상경계법(IBM)은 물체를 포함한 전체 전산 영역을 직교 좌표계에 의해 이산화하고, 유동장내 존재하는 물체의 표면에서의 점착 조건을 만족시키기 위하여 지배 방정식에 적절한 외력을 추가로 고려하는 방법이다. 본 연구에서는 가상경계법을 이용하여 경계층에 위치한 건물 형상의 각진 물체 주위 사이에 형성되는 공동 내부의 비정상 유속 및 압력에 대한 전산 해석을 수행하고, 풍상측 전면에 형성되는 경계층에 의한 영향을 분석하였다.

  • PDF

Separation Study of Cytosine and Guanine by HPLC and Aspen Chromatography (Aspen Chromatography 전산모사와 HPLC를 이용한 구아닌 시토신의 분리특성연구)

  • Park, Moon Bae;Kim, In Ho
    • Korean Chemical Engineering Research
    • /
    • v.48 no.1
    • /
    • pp.88-92
    • /
    • 2010
  • DNA structure studies attract many interests in pharmaceutical, biochemical and medical disciplines. Among them, base pairs play a vital role in biological information transfer. Therefore, they need to be analyzed in various ways and the pair of guaninine and cytosine is the present analytical object. Separation of guanine and cytosine was researched by Aspen chromatography simulator and HPLC(High Performance Liquid Chromatography) experiments. Aspen chromatography simulation resulted in various chromatograms with changes of sample concentration, eluent flow rate and number of plate. The resolutions and yields of guanine and cytosine were calculated to obtain a best separation condition. $C_{18}$ HPLC column and water/methanol/acetic acid mixture(90/10/0.2) were used for separation of guanine and cytosine. HPLC parameters(resolution and number of theoretical plate) were calculated under different flow rates and sample concentrations. Aspen chromatography simulation and HPLC experimental results were compared with fair agreement.