• Title/Summary/Keyword: 전반사형광

Search Result 9, Processing Time 0.03 seconds

On the Dynamic Characteristics of Cell Contact by Analyzing TIRE Images (전반사 형광 이미지 분석을 통한 세포 부착점의 운동 특성에 관한 연구)

  • Lee, Yong-Ku;Jin, Song-Wan;Koo, Sang-Mo;Yoo, Jung-Yul
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.31 no.3 s.258
    • /
    • pp.380-387
    • /
    • 2007
  • We carried out an image analysis of living cells forming their contacts at the bottom of the cell culturing substrate. In order to visualize the contact area selectively, we adopted total-internal-reflection-fluorescence (TIRF) method, which can illuminate the specimen volume within only several hundred nano-meters above the substrate. From the fluorescent intensity of the TRF image, we could calculate the distance of the cell surface from the substrate. As a result, we visualized the origin of cell contacts, their movements, and the change of cell-contact type from the close-contact into focal-contact with information of its vertical displacement representing the temporal evolution process of the three-dimensional cell-surface-profile near the contact area during this metamorphosis.

Development of a Total Internal Reflection Fluorescence (TIRF) Microscopy for Precise Imaging the Drying Pattern of a Sessile Droplet (고착 액적 증발면의 정밀 관측을 위한 전반사 형광 현미경 기법 개발)

  • Wonho Cho;Jinkee Lee
    • Journal of the Korean Society of Visualization
    • /
    • v.21 no.3
    • /
    • pp.65-74
    • /
    • 2023
  • Compared to epifluorescence(EPI) microscopy which captures fluorescence from the entire depth of sample, total internal reflection fluorescence(TIRF) can selectively visualize only a single surface of it. TIRF uses a thin evanescent field generated by the total internal reflection of laser light on surface. However, conventional TIRF system are designed for total internal reflection to occur at the upper surface of sample, making them unsuitable for sessile droplet imaging. We designed a TIRF system suitable for a sessile droplet imaging by utilizing slide glass as a lightguide. We presented the details for constructing the TIRF system using a prism, slide glass, air slit, and optical trap. Then, we compared the TIRF with EPI by imaging the droplet with fluorescent particles during its drying process. As a result, TIRF allows us to distinctly visualize the drying pattern on the bottom surface of droplet.

Fabrication and analysis of luminous properties of ceramic phosphor plate for high-power LED (High-power LED용 ceramic 형광체 plate 제조 및 발광 특성 분석)

  • Ji, Eun-Kyung;Song, Ye-Lim;Lee, Min-Ji;Song, Young-Hyun;Yoon, Dae-Ho
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.25 no.1
    • /
    • pp.35-38
    • /
    • 2015
  • LEDs are considered to be an alternative for enhancement of energy efficiency, applied for numerous areas such as display, automotive headlight not only lights. Yellow phosphor is generally utilized with blue LEDs to generate WLED, $Y_3Al_{5}O_{12}:Ce^{3+}$ is typically used as the yellow phosphor. The phosphor, mixed with epoxy resin, has been used by being spread and hardened on the blue LED chip. This paste-based packaging gives rise to problems of degradation of phosphor by heat and decrease of luminous efficiency. Although phosphor plate is used instead of the epoxy-phosphor mixture to solve these problems, loss of luminous efficacy by total internal reflection inside the plate also should be solved. In this study, we coated the side of the plate with silver as one of the solution.

Improvement of detection sensitivity of impurities on Si wafer surface using synchrotron radiation (방사광을 이용한 Si 웨이퍼 표면불순물 검출감도 향상)

  • 김흥락;김광일;강성건;김동수;윤화식;류근걸;김영주
    • Journal of the Korean Vacuum Society
    • /
    • v.8 no.1
    • /
    • pp.13-19
    • /
    • 1999
  • Total reflection X-ray fluorescence spectroscopy using synchrotron radiation source called as TRSFA was explored to achieve high sensitivities to impurity metals on Si wafer surface. It consists of monochromating part to select a specific wavelength, slit part to shield direct beam and to control monochromated beam, and main chamber to dectect fluorescent X-ray counts of impurities on si wafer. Monochromated X-ray of 10.90 KeV was selected and the optimum total reflection condition on silicon wafer was obtained through tuning the dead time and fluorescent X-ray count of Si and Fe. TRSFA system could increase the sensitivity as high as 50 times in comparision with TRXFA using normal X-ray source. But the trend was varied since the surface conditions of Si wafers and, therefore, the reflectivities were different. Furthemore, there seems to be a promising path to reaching a detection limit useful to the next generation metal impurities control, because Fe impurity below to the $5\times10^{9}\textrm{atomas/cm}^2$ can be detectable through the developed TRSFA system.

  • PDF

Neuroprotective Effects of Pinelliae Rhizoma Water-Extract by Suppression of Reactive Oxygen Species and Mitochondrial Membrane Potential Loss in a Hypoxic Model of Cultured Rat Cortical Cells. (배양대뇌신경세포 저산소증모델에서 유해산소생성억제 및 사립체막전위 소실방지에 의한 반하(半夏)의 신경세포사 억제 효능)

  • Kwon, Gun-Rok;Moon, Il-Soo;Lee, Won-Chul
    • Journal of Life Science
    • /
    • v.19 no.5
    • /
    • pp.598-606
    • /
    • 2009
  • Oxidative stress by free radicals is a major cause of neuronal cell death. Excitotoxicity in hypoxia/ischemia causes an increase in reactive oxygen species (ROS) and a loss of mitochondrial membrane potential (MMP), resulting in dysfunction of the mitochondria and cell death. Pinelliae Rhizoma (PR) is a traditional medicine for incipient stroke. We investigated the effects of PR Water-Extract on the modulation of ROS and MMP in a hypoxic model using cultured rat cortical cells. PR Water-Extract was added to the culture medium at various concentrations (0.25${\sim}$5, 5.0 ${\mu}g/ml$) on day in vitro 12(DIV12), given a hypoxic shock (2% $O_2$/5% $CO_2$, $37^{\circ}C$, 3 hr), and cell viability was assessed on DIV15 by Lactate Dehydrogenase Assay (LDH assays). PR Water-Extract showed a statistically significant effect on neuroprotection (10${\sim}$15% increase in viability; p<0.01) at 1.0 and 2.5 ${\mu}g/ml$ in normoxia and hypoxia. Measurement of ROS production by $H_2DCF-DA$ stainings showed that PR Water-Extract efficiently reduced the number and intensity of ROS-producing neurons, especially at 1 hr post shock and DIV15. When MMP was measured by JC-1 stainings, PR Water-Extract efficiently maintained high-energy charged mitochondria. These results indicate that PR Water-Extract protects neurons in hypoxia by preventing ROS production and preserving the cellular energy level.

LED Beam Shaping and Fabrication of Optical Components for LED-Based Fingerprint Imager (LED 빔조형에 의한 초소형 이미징 장치의 제조 기술)

  • Joo, Jae-Young;Song, Sang-Bin;Park, Sun-Sub;Lee, Sun-Kyu
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.36 no.10
    • /
    • pp.1189-1193
    • /
    • 2012
  • The Miniaturized Fingerprint Imager (MFI) is a slim optical mouse that can be used as an input device for application to wireless portable personnel communication devices such as smartphones. In this study, we have fabricated key optical components of an MFI, including the illumination optical components and imaging lens. An LED beam-shaping lens consisting of an aspheric lens and a Fresnel facet was successfully machined using a diamond turning machine (DTM). A customized V-shaped groove for beam path banding was fabricated by the bulk micromachining of silicon that was coated with aluminum using the shadow effect in thermal evaporation. The imaging lens and arrayed multilevel Fresnel lenses were fabricated by electron beam lithography and FAB etching, respectively. The proposed optical components are extremely compact and have high optical efficiency; therefore, they are applicable to ultraslim optical systems.

Non-destructive Analysis of Material Characteristics and Provenance of Granite Monuments: The Cases of Stupa for National Preceptor Wongong at Geodonsa Temple and Five-story Pagoda at Cheonsusa Temple (비파괴 분석을 이용한 화강암류 석조 문화재의 부재특성과 산지추정: 거돈사 원공국사 승묘탑과 천수사 오층석탑을 중심으로)

  • Kim, Yonghwi;Choi, Seongyu;Seo, Jieun;Kang, Jeonggeuk;Lee, Jonghyun;Jo, Yeontae
    • Conservation Science in Museum
    • /
    • v.19
    • /
    • pp.19-40
    • /
    • 2018
  • Most stone monuments in Korea are made from the granitoids found extensively throughout the nation. To identify the provenance of the stone materials, this study carried out comprehensive analyses of the occurrence, physical properties, mineralogy, and chemical composition of Stupa for National Preceptor Wongong at Geodonsa Temple and Five-story Pagoda at Cheonsusa Temple, both located in the Gangwon region. Their features were compared with those of granite from Wonju City near the sites of the two monuments. Stupa for National Preceptor Wongong is composed purely of two-mica granite, whereas Five-story Pagoda was made from both two-mica and biotite granites. The occurrence and magnetic susceptibility of the two granite monuments generally coincide with those of granite from Wonju. When selecting materials for the restoration of stone monuments, it is deemed necessary to carry out a field survey on granite in areas adjacent to the locations of the stone monuments subject to restoration.