• Title/Summary/Keyword: 전력시스템(electrical power system)

Search Result 1,881, Processing Time 0.049 seconds

The study of the remort power analysis and control system using power line communication (전력선 통신을 이용한 원격 전력분석 및 제어시스템에 관한 연구)

  • Choi, Won-Ho;Lee, Hoo-Chan;Park, Chong-Yeun
    • Proceedings of the KIPE Conference
    • /
    • 2005.07a
    • /
    • pp.211-213
    • /
    • 2005
  • RPA(Remelt Power Analysis)and RC(Remote Control) System have been researched from former several decade for a various power rate system a efficent power service and rising of personal expenses, etc. But the existing RPA and RC System have disadventage which are complex and high cost to install an individual communication network of electricity company This paper proposed a new type of RPA and RC System using PLC with Internet. and made components for proposal system so we made the PLC modem, the digital watt-hour meter with a build in PLC modem and the softwere on server computer for establishing the proposal system. The bit rate of the proposed system is about 4800bps.

  • PDF

Compensation of Instantaneous Voltage Drop at AC Railroad System with Single-Phase Distributed STATCOM (전기철도 급전시스템의 순시전압강하 보상을 위한 단상 배전 STATCOM의 적용)

  • Kim, Jun-Sang;Lee, Seung-Hyuk;Kim, Jin-O;Lee, Jun-Kyung;Jung, Hyun-Soo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.1
    • /
    • pp.42-51
    • /
    • 2007
  • An AC electrical railroad system has rapidly changing dynamic single-phase load, and at a feeding substation, three-phase electric power is transformed to the paired directional single-phase electric power. There is a great difference in electrical phenomenon between the load of AC electrical railroad system and that of general power system. Electric characteristics of AC electrical railroad's trainload are changed continuously according to the traction, operating characteristic, operating schedule, track slope, etc. Because of the long feeding distance of the dynamic trainload, power quality problems such as voltage drop, voltage imbalance and harmonic distortion my also occur to AC electrical railroad system. These problems affect not only power system stability, but also power quality deterioration in AC electrical railroad system. The dynamic simulation model of AC electrical railroad system presented by PSCAD/EMTDC is modeled in this paper, andthen, it is analyzed voltage drop for AC electrical railroad system both with single-phase distributed STATCOM(Static Synchronous Compensator) installed at SP(Sectioning Post) and without.

Web based Customer Power Demand Variation Estimation System using LSTM (LSTM을 이용한 웹기반 수용가별 전력수요 변동성 평가시스템)

  • Seo, Duck Hee;Lyu, Joonsoo;Choi, Eun Jeong;Cho, Soohwan;Kim, Dong Keun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.22 no.4
    • /
    • pp.587-594
    • /
    • 2018
  • The purpose of this study is to propose a power demand volatility evaluation system based on LSTM and not to verify the accuracy of the demand module which is a core module, but to recognize the sudden change of power pattern by using deeplearning in the actual power demand monitoring system. Then we confirm the availability of the module. Also, we tried to provide a visualized report so that the manager can determine the fluctuation of the power usage patten by applying it as a module to the web based system. It is confirmed that the power consumption data shows a certain pattern in the case of government offices and hospitals as a result of implementation of the volatility evaluation system. On the other hand, in areas with relatively low power consumption, such as residential facilities, it was not appropriate to evaluate the volatility.

The Design of Master Station for Intelligent Distribution Automation System (배전지능화시스템 개발을 위한 중앙제어장치 설계)

  • Park, Shin-Yeol;Ha, Bok-Nam;Shin, Chang-Hoon;Kwon, Seong-Chul;Park, So-Young
    • Proceedings of the KIEE Conference
    • /
    • 2006.11a
    • /
    • pp.261-263
    • /
    • 2006
  • 전력 계통은 발전설비, 송전설비, 변전설비, 배전설비 등으로 크게 나눌 수 있다. 전력계통을 구성하는 이런 설비들을 원격 감시하고 제어하는 시스템을 전력자동화 시스템이라고 한다. 이런 전력자동화 시스템은 국내 전체 에너지의 수요, 공급, 수송을 제어하는 에너지 관리시스템(EMS : Energy Management System), 송전 및 변전설비의 감시제어를 담당하는 송변전소 감시제어 시스템(SCADA : Supervisory Control And Data Acquisition), 배전계통의 실비관리 및 운영을 담당하는 배전자동화시스템(DAS : Distribution Automation System), 수용가의 계량기를 원격으로 읽어오는 원격검침시스템 (AMR : Automatic Meter Reading) 통으로 구성되어 있다. 국내에서 운용중인 배전자동화 시스템은 배전선로에 설치되어 있는 개폐기만을 원격 감시 및 제어 하는 보편적인 시스템이다. 한편, 2005년도 전력IT 국가 전략과제로 수행하고 있는 배전지능화 시스템 개발 과제에서는 변전소부터 배전계통과 수용가까지의 모든 전력 설비에 대한 원격감시제어가 가능한 시스템을 배전지능화 시스템이라고 정의하고 이의 개발을 추진하고 있다. 본 논문에서는 ABB, SIEMENS, GE와 같은 국외의 배전 자동화 시스템들을 소개하고, 배전지능화 시스템에서 목표로 하고 있는 GIS 기반 위에서 고 저압 배전설비를 관리하고, SCADA, DAS, GIS(Geographic Information System), AMR, TCS(Trouble Call System) 등 배전지능화 시스템의 중앙제어장치가 갖추어야 하는 주요 기능들에 대해 기술하고자 한다.

  • PDF

Geographic Information System for Developing Advanced Distribution Management System (차세대 배전지능화시스템 개발을 위한 지리정보시스템 적용)

  • Kim, DongWook;Cho, SungHo;Seo, Hojin;Park, YoungBae
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.5 no.2
    • /
    • pp.67-74
    • /
    • 2019
  • Recently, as the renewable distributed energy resources has increased, the variability within the electrical power distribution system has increased, so that there is a growing concern about the stable electrical power distribution system. For efficient management of future electrical power distribution system, it is necessary to improve the electrical power distribution system operation using new visualization technology. In this paper, we describe the current status of GIS introduction and related technology trends in the field of electrical power distribution, and analyze the necessity of GIS system for electrical power distribution system operation and problems to be solved when introducing GIS technology.

Power IT Function Improvement Idea for Large-scale Power System (대규모 전력계통 운영을 위한 전력IT 기능개선 방안 고찰)

  • Son, Yoon-Tae;Kim, Sung-Hak
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.290-291
    • /
    • 2008
  • 전력계통의 운영은 생산과 소비가 동시에 이루어지는 특성을 지닌 전기를 사용하는 고객에게 양질의 전기를 중단 없이 공급하기 위하여 전체 전력계통을 실시간으로 감시 제어하고, 계통주파수를 자동으로 조정하는 설비인 에너지관리시스템(EMS: Energy management system)을 이용한다. 또한 시장운영시스템(MOS : Market Operating System)은 전력을 일반 상품처럼 사고 팔기 위하여 입찰, 계량, 정산기능을 수행하고 있다. 이들 시스템은 전력산업분야의 최정점에 있는 핵심적인 장치로서 복잡한 전력계통의 운영과 효율적인 전력시장 운영을 위하여 견고한 플랫폼과 계통규모에 적합한 다양한 어플리케이션이 제공되어야 한다. 세계적으로 이들 시스템은 약 10${\sim}$15년 주기로 업그레이드 혹은 설비 전면 대체를 하고 있으며 이때 설계자가 과거, 현재의 경험을 바탕으로 미래 지향적인 관점에서 심사숙고하여 설계하느냐에 따라 향후 전력산업발전에 지대한 영향을 미칠 수 있다.

  • PDF

A study of noise reduction for reliable data transmisstion in PLC (전력선 통신 환경에서의 신뢰성 있는 데이터 전송을 위한 잡음제거에 관한 연구)

  • Lee, Hong-Hee;Kim, Gwan-Su
    • Proceedings of the KIPE Conference
    • /
    • 2001.07a
    • /
    • pp.642-645
    • /
    • 2001
  • 본 논문에서는 전력전달 매체인 전력선을 이용하여 신뢰성 있는 통신환경을 구축하기 위해 필요한 전력선 통신 시스템에서의 임피던스, 잡음, 특성 등을 고찰했다. 이를 바탕으로 기존 네트워크에 사용 되어온 DS-SS(Direct sequence-Spread Spectrum) 기법을 전력선 통신에 적용하여 전력선통신 시스템을 구성하고 다중 액세스 기법인 CSMA를 적용하여 시스템 효율에 대한 성능 평가를 하였다.

  • PDF

Active Power Filter Type Uninterruptible Power Supply (UPS) (전력용 능동필터형 무정전 전원장치)

  • 김제홍;최재호
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.12 no.4
    • /
    • pp.100-105
    • /
    • 1998
  • This paper proposes a new control strategy of bidirectional uninterruptible power supply (UPS) with the performance of active power filter which compensates the harmonics and reactive power. With only one power stage, it is working simultaneously as the AC/DC rectifier/battery charger and DC/AC inverter to the operation of battery charging or back-up power supplying. Therefore the operation of the proposed system can be divided into the modes, such as the active power filter mode and the battery back-up power mode. And a novel closed-loop control strategy is used to calculate the reference current. The performance of the proposed 5[kVA] system is verified by the simulation and experimental results.

  • PDF

Linked operation between energy management system(EMS) and market operation system(MOS, CBP) (계통운영시스템(EMS)과 시장운영시스템(MOS,CBP)간 연계운영)

  • Park, Bong-Yong;Kim, Myung-Woong;Ahn, Jae-Seung;Kim, Min-Bae
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.547_548
    • /
    • 2009
  • 전력거래소에서 전력계통 및 전력시장 운영을 위해 도입한 핵심시스템은 EMS, MOS, CBP 이다. 이 세개 시스템은 각각 고유의 기능을 가진 별도의 시스템으로 구축되었다. 우리나라의 전력시장이 발전경쟁단계에 머무르면서 당초 양방향전력시장용으로 도입된 MOS시스템이 활용되지 못함에 따라 MOS시스템의 실시간 급전기능을 활용해 전력계통 운영의 안정성 및 경제성 향상을 꾀하고자 이 세 개의 시스템을 2006년 10월부터 연계 운영하고 있다. 이를 위해 CBP입찰값을 MOS의 입찰형식으로 변환하기위한 CBP-MOS 입찰변환시스템, 실시간 수요예측을 위한 수요예측 프로그램, MOS와 EMS를 일괄적으로 연계하기 위한 연계Mode, 각 발전기 운전원들에게 발전기의 급전계획값 및 실시간 운전현황을 전송하기 위한 급전지시시스템(MX) 및 전반적인 시스템 연계운영을 종합적으로 감시하기 위한 종합감시시스템 등을 개발하여 운영하고 있다.

  • PDF

Analysis of the Effect of the Grid-connected Photovoltaic System in Fault Case of Power System (전력계통 고장시 계통연계형 태양광발전시스템의 영향분석)

  • Park, Sung-Hun;Lee, Yong-Sik;Jeong, Sung-Won;Gim, Jae-Hyeon
    • Journal of the Korean Solar Energy Society
    • /
    • v.39 no.4
    • /
    • pp.69-77
    • /
    • 2019
  • Among the main functions of the grid-connected photovoltaic (PV) system, the anti-islanding operation function is a very important problem. Recently, due to the improvement in power generation efficiency and the maintenance advantages in PV system, the use of string inverter has increased so that the possibility of islanding operation has been raised. Generally, when a power system faults, the PV inverter must be disconnected from power system within 10 cycles by the anti-islanding operation function. However, in the real-time of power system, the output power of the PV system within 10cycles is effected. In this paper, we analyzed the effect of grid-connected PV system on power quality in a short time within 10 cycles on fault case of power system using the Matlab Simulink program.