• Title/Summary/Keyword: 전력선통신모뎀

Search Result 49, Processing Time 0.065 seconds

Implementation of Zigbee/PLC Gateway System for U-Health Care (유비쿼터스 헬스케어를 위한 Zigbee/PLC 게이트웨이 시스템 구현)

  • Kim, Sung-Yun;Kang, Kyung-Il;Kweon, Min-Su;Rhee, Young-Chul
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.5 no.3
    • /
    • pp.332-338
    • /
    • 2010
  • In this paper, Zigbee/PLC gateway system is designed for Ubiquitous health care. A protocol conversion algorithm for smooth information exchange between Zigbee and PLC communication has been implemented on the gatway. If a moving object is detected by wireless sensor, the data is transmitted to gateway. Zigbee/PLC gateway analyzes received data and transmits to Power Line Communication for real-time monitoring. Implemented system is can support elder who lives alone activity analysis, crime prevention system, Home network service.

High Speed PLC-based Automatic Control System for a Smart LED Streetlight (스마트 LED 가로등을 위한 고속 전력선 통신 기반 자동제어 시스템)

  • Kim, Young-Suk;Lin, Chi-Ho
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.14 no.5
    • /
    • pp.95-102
    • /
    • 2014
  • In this paper, we propose the high speed PLC-based automatic control system for a smart LED streetlight. The proposed the automatic control system were constructed of a power line modem part and monitoring part, streetlight controller part for the high speed communication frequency band and streetlight ballasts characterization and real-time remote control using a high-speed PLC network, and it was designed to meet to lighting grades conditions of KS road lighting standards. The proposed automatic control system were easy monitoring of the power consumption using PC through to the comparison result of the existing streetlight system. As a result, it was confirmed to the possibility of efficient operation for the real-time monitoring and maintenance by induction of reasonable power consumption through to the LED streetlight state checking and remote-control. In addition, we proved to improvement of expected effects for the power cost savings, the energy efficiency, and streetlight differentiation and advanced.

An Analysis of Characteristics of Underground Power line Communication Channel (지중 전력선 통신채널의 특성 해석)

  • Eom, Ki-Hwan;Shin, Jai-Ho;Lee, Seung-Joon
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.48 no.5
    • /
    • pp.40-45
    • /
    • 2011
  • In this paper, to develop a broadband power line communication modem and network technologies, we analysis the characteristics of underground power line communication channel through actual tests. To measure the amount of attenuation by length and structure of broadband power line communication channel, we configure a measurement system of the channel with signal generator, spectrum analyzer and non-contacted coupler. For actual tests, we choose two of the longest lines among medium-voltage lines as a single line in the test lines and measure the characteristics of noise and signal attenuation level of the channel. The experimental results show that the channel has a impulse noise which can remarkably reduce communication capability. In the case of long lines, high-frequency attenuation appeared by length of the lines.

Implementation of PC-based education PLC(Power Line-network Communication) control system using Labview (LabView를 이용한 PC기반의 교육용 전력선망 통신 제어시스템 구현)

  • Park, Tae-Jin;Lee, Un-Sun;Lee, Sang-Hee;Lee, Jong-Hee
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.17 no.3
    • /
    • pp.730-739
    • /
    • 2013
  • More than 30% of energy in Korea was spent in lighting part and then the consumption level and $CO_2$ emission will be increase from now. In this like situation, control-system construction for street-lamp of a smart grid-based that it has important meaning. Nowadays as a result, as an trying to utilize using Power-line-network communication modem and application a terminal in industrial fields, in this paper, we are want to implement the Power-line-network communication control system of PC-based. Therefore it will be use varied communication test-equipment and tools through the system. For experimentation, using the MODEM was able to use Planet production of based on the ZIC protocol and then the application program use the LabView. The result is primarily focused on equipments control by the PLC, and that we are able to perform each test with PLC equipment for experiment it.

Implementation of Single-Carrier BPSK Powerline Modem based on EIA-709.2-A PL (EIA-709.2-A PL에 근거한 단일 캐리어 BPSK 전력선 모뎀 구현)

  • Woo, Dae-Ho;Yoo, Young-Gyu;Byun, Youn-Shik
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.32 no.4A
    • /
    • pp.325-329
    • /
    • 2007
  • In this paper, the modem based on EIA-709.2-A PL of powerline communication techniques which are considered to be important technologies for in-home control network systems was implemented via VHDL. In order to have the robust properties against existing noises over powerline channels, the information data using eight symbols was transmitted by transmitter and the receiver is composed of matched filter, averager, decision and detection parts in order to detect the right data from the received signals. The implemented PLC transceiver was downloaded into Altera's EP1S25C672 FPGA and the operation was verified successfully.

Study on the Technical Specifications of ADSL Modem and Power-Line Communication Equipment (ADSL 모뎀 및 전력선통신용 전송장치에 관한 기술기준의 제정 연구)

  • 김용환;조평동;박기식
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2001.10a
    • /
    • pp.415-418
    • /
    • 2001
  • Korean government regulates the technical specifications for the terminal equipments connecting to public telephone network, while equipments in the market are subjected to the type-approval confirming with the technical specifications. foreseeing the revision of the technical specifications, this paper discussed on technologies considered to be additional to the specifications including ADSL modem and power-line communication equipment.

  • PDF

A Study on Power Line Communication System using FEC Methods (콘벌루션 코딩 및 DS-SS 방식을 이용한 전력선 통신 시스템에 관한 연구)

  • Kim, Gi-Jung;Park, Chong-Yeun
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.48 no.4
    • /
    • pp.467-473
    • /
    • 1999
  • We have realized the two kinds of power line communication systems by the FSK MODEM. The first approach is the DS-SS (Direct suquence-spread spectrum) technique using 8 bits pseudo noise, the other is Convolutional coding method by the new algorithm. Their characteristics are comparied with each other by experimenting their Bit Error Rates (BER) in high level of Noise. The results have showed that two systems are useful to the application of HA (Home Automation) systems.

  • PDF

Properties of Blocking Filter as a function fo Magnetic Core shapes for Power Line Communication (자심재료의 형상에 따른 전력선 통신용 블로킹 필터의 특성)

  • Kim, Hyun-Sik;Lee, Hae-Yon;Ji, Min-Kwon;Oh, Young-Woo;Byun, Woo-Bong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.230-230
    • /
    • 2007
  • 전력선 통신(Power Line Communication)은 최근 전력선을 이용한 통신기술의 발달과 더불어 세계적으로 관심도가 높아지고 연구 개발 및 자본 투자가 활발히 진행되고 있으며, 안정적인 네트워크를 구성하기 위해서는 고주파 전력선 통신 신호를 차단하는 블로킹 필터가 반드시 적용되어야 한다. 전력선 통신용 블로킹 필터는 광대역의 주파수 특성과 높은 신호감쇄 특성 및 대전류 특성이 요구되며, 이러한 특성을 구현하기 위해서는 블로킹 필터의 핵심부품인 자심재료의 고투자율 및 대전류화가 이루어져야 한다. 따라서 본 연구에서는 우수한 전 자기적 특성이 균일하게 유지되고, 전력선에 흐르는 대전류에 의한 자심재료의 포화가 발생하지 않도륵 새로운 자심 재료를 설계하여, 전력선 통신을 적용한 홈 네트워크 구축의 핵심 부품인 광대역 블로킹 필터를 개발하고자 하였다. 2350과 0.3 T의 투자율과 포화자속 밀도를 갖는 EI 형상의 자심재료를 해석모델로 설정하고 다중 에어 갭의 위치에 따른 전류와 자속밀도 변화를 유한요소 해석법으로 분석한 결과 자심재료의 대전류 특성에 지배적인 영향을 미치는 에어 캡의 삽입 위치를 알 수 있었고, 새로운 해석 모델인 I 형상의 로드(ROD) 코어에 대해 수치해석을 수행하여, 100A의 통전 전류에서도 자기적으로 포화되지 않고 인덕턴스의 정밀 제어가 가능하고, 특성의 신뢰성과 대전류에 대한 안정성을 증가시킬 수 있는 인덕터를 설계하였다. 또한 수동소자를 이용한 LC 공진회로를 기본 구성으로 하고, 주파수 대역, 신호 감쇄율과 대전류 특성, 상용화를 고려하여 블로킹 필터 회로를 설계하였으며, 유한요소해석법을 적용한 전자장 모의해석을 통하여 최소의 크기를 갖는 I 형상의 자심재료에 $6{\Phi}$의 에나멜 동선을 6.5턴, 6턴 권선하여 2.5, $2.15\;{\mu}H$의 인덕턴스를 갖는 직렬 인덕터를 구현하였고 블로킹 필터를 구성하였다. 주파수에 따른 신호감쇄 특성을 5 Hz~1 MHz의 주파수 범위에서 측정한 결과 약 490 kHz~450 kHz의 주파수 대역에서 -70dB의 신호감쇄 특성을 나타냈다. 본 연구를 통해 개발된 100A급 광대역 블로킹 필터가 적용되어 상용화 될 수 있을 것으로 판단되며, 또한 모뎀 통신 주파수 대역에서 -70dB 이상의 높은 감쇄 특성을 갖기 때문에 신호차단 특성이 보다 우수할 것으로 사료된다.

  • PDF

Measurement of Indoor Power Line Channel Characteristics Considering Capacitive Loads (용량성 부하를 고려한 옥내 전력선 채널 특성 측정)

  • Heo Yoon-Seok;Hong Bong-Hwa;Kim Chul;Jun Kye-Suk;Lee Dae-Young
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.42 no.6 s.336
    • /
    • pp.53-60
    • /
    • 2005
  • Considerable efforts has been recently devoted to the determination of accurate channel models for the power line environment, both for the indoor and outdoor cases. The common limitation of the known and previously published models is the particular type of approach followed. This paper is concerned with a power line channel characteristic measurement for the more fast and efficiently power line communication experiment. The need arises from the fact that indoor power cables consist of conductors and inductors. A capacitive load simulator is a essential equipment in the power line modem development for indoor power line network. We accomplished a channel data base by the frequency response method about the total 224 capacitor load cases. On the basis of this measurement modeling it is here revealed that the power line communication channel is a more deterministic media.

Development of Low Power PLC Modem for Monitoring of Power Consumption and Breaking of Abnormal Power (전력감시 및 이상전력 차단 기능을 갖는 저전력 전력선통신 모뎀 개발)

  • Yoon, Jae-Shik;Wee, Jung-Chul;Park, Chung-Ha;Song, Yong-Jae;Kim, Jae-Heon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.11
    • /
    • pp.2281-2285
    • /
    • 2009
  • Powerline communication is the data signal which is modulated by carrier frequency through the installed powerline at in-home or office is transmitted and received signals are separated into data signal with using band-pass filter which cent-frequency is carrier frequency. The home gateway, an equipment which works as an gateway for ubiquitous home network, relays all functions of a home network. The home gateway must always be connected in order to provide seamless services. However it gives unfavorable power consumption. Therefore the needs for working in maximum power saving mode while there is no data traffic and for invoking to the normal function when it is necessary. So, in this paper we survey the development of low power PLC modem monitoring of power consumption and breaking abnormal power in the home Network.