• Title/Summary/Keyword: 전력감시

Search Result 638, Processing Time 0.023 seconds

A New Moving Mobile Base Station (MMBS) Scheme for Low Power RMIMS Wireless System(PartII:Multiple MMBS service schemes for RMIS QoS guarantee) (저전력 RMIMS 무선 터미널을 위한 새로운 움직이는 이동 기지국 시스템 구조(2부:QoS 보장을 위한 다중 MMBS 서비스 구조))

  • 박수열;고윤호;유상조;김성대
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.24 no.12B
    • /
    • pp.2320-2334
    • /
    • 1999
  • In this paper, we propose multiple IS-MMBS service schemes for very low power and micro-size RMIMS (radio-interfaced micro information monitoring system) terminals. In MMBS service area, when new arrival RMIMS terminals have real-time traffic characteristic or large traffic bandwidth, only single IS-MMBS service scheme can not guarantee RMIMS terminal's QoS(quality of service) such as buffer overflow or packet loss. In this case, the proposed multiple IS-MMBS service schemes can be effectively used for QoS service of RMIMS terminal. According to clustering method of RMIMS terminals and MMBS segment method, the proposed schemes can be divided into terminal segment method, region segment method, application based segment method, traffic type based segment method, overlapping segment method and hybrid segment method

  • PDF

영상정보용 공용데이터링크 표준화 발전방향

  • Jeong, Jong-Mun;Park, Gyu-Cheol;Won, Tae-Yeon;O, Ui-Hwan;Go, Dong-Cheol;Hong, Seok-Jun;Yun, Chang-Bae;Kim, Ho;Park, Ui-Yeong
    • Information and Communications Magazine
    • /
    • v.28 no.4
    • /
    • pp.41-50
    • /
    • 2011
  • 미래 전에서는 정보의 중요성이 더욱 부각되고 있으며 정보의 수집 및 전파, 정확한 지휘결심 및 전파, 기동타격체계의 통제 등으로 이어지는 지휘통제의 전 과정을 유기적으로 연결하여, 그 성능을 극대화시키는 것이 네트워크 중심전(NCW: Net-Centric Warfare)의 개념이다. NCW 실현을 위해 개발중인 여러 체계 중 주목 받고 있는 것이 무인기(UAV: Unmanned Aerial Vehicle) 이다. 무인기는 감시정찰, 고정밀 타격, 그리고 전투피해평가 기능 등을 수행하며, 전술적인 상황인식이 가능하게 한다. 무인기가 이러한 임무를 수행하기 위해서는 비행체의 상태정보, 비행체의 조종통제정보, 그리고 임무 탑재체가 획득한 정보의 간단없고 정확한 전달이 요구된다. 이러한 정보를 전송하기 위한 비행체와 지상체간의 제반 통신을 데이터 링크(Data Link)라 하며, NCW 구현에 있어서 가장 핵심이 되는 요소이다. 세계 각국은 영상정보 수집자산으로서 무인기와 데이터링크의 개발에 박차를 가하고 있는 실정이며, 우리 군도 전력화가 계획된 각 제대별 무인기의 통합운용을 위한 영상정보 공용데이터 링크 (MPI-CDL: Multi-Platform Image and Intelligence Commom Data Link)를 개발중에 있으며 지속적인 영상정보 수집자산의 소요증가에 따른 주파수 획득문제와 사업별 독자적인 데이터 링크의 개발을 지양하고 기존체계와의 상호운용 및 단절없는 통신을 보장을 위해 개발과 동시에 국가적 차원에서의 기술구조 표준화가 추진되어야 한다. 이러한 시점에서 본고에서는 먼저 선진국의 (CDL : Commom Data Link) 표준화 동향을 알아보고, 상호운용성과 연동을 위한 한국형 MPI-CDL 기술 표준화방향을 제시하고자 한다.

Implementation and application of remote control system using LACC(Local Area Control Center) (LACC를 이용한 원격제어 시스템 구현 및 적용)

  • Park Tae-Jin;Jang Myung-Kee;Chung Seung-Ryul
    • Journal of the Institute of Electronics Engineers of Korea CI
    • /
    • v.43 no.4 s.310
    • /
    • pp.15-22
    • /
    • 2006
  • Nowadays, there is called energy saving, that it is accomplished with a lot study and application development as according to demand of all around world. It is using to network device of wire or wireless such as internet, lan, plc, and zigbee and that we should be accomplished to study about method that spending a little cost to fatal error in control system that be expected of frequent occurrence on network, and that have method to do construction a little bit tried out. Also, in that such a embedded system with network function case, there is important thing that it is remote management to network node and control methods to trust because firmware upgrade have the advantage of more than the other device. In this paper, we have verified through a result of experiment for efficient remote management and control method as previously stated in this paper, that it is area of the PLC for sensor node and doing management to relay, and implementation of the LACC which is core part of the ESS, and in order to get a result to trust from doing analysis of capacity and test.

Design of Measuring System for Insulation Resistance and Humidity in High-Power XLPE Cables in Operation and the Relationship Between Insulation Resistance and Humidity in the Oversheath (운전 중인 고전력 XLPE 케이블의 절연저항과 습도의 측정 시스템 설계 및 방식층 절연저항과 습도의 상관관계)

  • Um, Kee-Hong
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.16 no.5
    • /
    • pp.179-184
    • /
    • 2016
  • The usual way used by electric power stations to deliver high levels of generated power is via 6.6kV XLPE (or CV) cables. Depending on the manufacturing technique, installation environment, and usage conditions, the deterioration processes of the power cables start from the instant of operation. Cable junctions may break down in three years from the start of operation due to the manufacturing or construction defects. Otherwise they should be in good working order for 20-30 years. When the cable system (the cable itself and cable junctions combined) deteriorates, fire accidents happen due to the dielectric breakdowns. We have invented a device to monitor the deteriorating status of cables at Korean Western Power Co. Ltd. located in Taean, Chungcheongnam-do province. In this paper, we introduce the device hardware. Using the device, we have measured the insulation resistance and humidity in the sheath of the cables. We present, in analysed results, the effect of humidity on insulation resistance in cable sheaths.

Examination of Conductor and Sheath Temperatures Dependent on the Load Currents through High-Power Live Cables at a Power Station (발전소에서 활선 고전력 케이블의 운전 부하전류에 따른 도체 및 피복표면의 온도 분석)

  • Um, Kee-Hong
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.17 no.1
    • /
    • pp.213-218
    • /
    • 2017
  • High-voltage power systems operate in order to generate and transmit electric power at power stations. Compared to low-power systems, high-power systems are complex in structure, large-scale, and expensive. When high-power cable accidents occur, most facilities are incapacitated-including low-power systems-causing huge economic losses. Great care must therefore be taken in designing, installing and managing power systems. Although dependent on installation circumstances and usage conditions, in some cases the cross-sectional areas of cables fall short of the critical area due to the expansion of and improper design and installation of power facilities. In this situation, the exceeded ampacity (allowable current) above the critical value caused by the operating current initiates the deterioration processes of power cables. In order to systematically monitor power cables operating at power stations, we have developed the first device of its kind in Korea. In this paper, we present the analyzed characteristics of expected temperatures of cables based on the load current of high-voltage cables operating at Korean Western Power Co. Ltd. We can predict the lifetime of cables by analyzing the temperature obtained from our device.

Comparison and Examination of the Measured Data With the Data from Other Company for the Conductor and Sheath Temperatures of Live 6 kV CV Single Core Cables (활선 6 kV CV 단심 케이블의 도체 및 표면온도 측정 데이터에 관한 타사 데이터와의 비교검토)

  • Um, Kee-Hong
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.17 no.3
    • /
    • pp.197-201
    • /
    • 2017
  • The demand for electric power is increasing every year in Korea. All the systems adopted at power stations in order to generate and transmit electric power should operate in perfect condition or reliability. The device for transmitting the generated high-voltage electric power is 6 kV CV single core cables. The manufacturing companies of the cables makes an official announcement that the operating lifetime of their cables is about 30years. But from the moment of operation the deterioration precesses of worsening the characteristics of cables starts. Since the reliability for the status of installed cables in deterioration has not been diagnosed, the cables can be broken at any unexpected moments. In order to prevent the abrupt cable accident by systematically monitoring the cable status, we have invented the first device in Korea. We have installed our device at Korea Western Power Co. Ltd. in order to diagnose the live cables. In this paper, we present our research results of measured temperatures of inner conductor and surface and the compared results of those data with other cable company. We also show that our results agree with those made by other company.

A Study on Development of App-Based Electric Fire Prediction System (앱기반 전기화재 예측시스템 개발에 관한 연구)

  • Choi, Young-Kwan;Kim, Eung-Kwon
    • Journal of Internet Computing and Services
    • /
    • v.14 no.4
    • /
    • pp.85-90
    • /
    • 2013
  • Currently, the electric fire prediction system uses PIC(Peripheral Interface Controller) for controller microprocessor. PIC has a slower computing speed than DSP does, so its real-time computing ability is inadequate. So with the basic characteristics waveform during arc generation as the standard reference, the comparison to this reference is used to predict and alarm electric fire from arc. While such alarm can be detected and taken care of from a remote central server, that prediction error rate is high and remote control in mobile environment is not available. In this article, the arc detection of time domain and frequency domain and wavelet-based adaptation algorithm executing the adaptation algorithm in conversion domain were applied to develop an electric fire prediction system loaded with new real-time arc detection algorithm using DSP. Also, remote control was made available through iPhone environment-based app development which enabled remote monitoring for arc's electric signal and power quality, and its utility was verified.

A Dynamic Duty Cycle Adjustment Mechanism for Reduced Latency in Industrial Plants (플랜트 시설에서 지연시간 감소를 위한 동적 듀티사이클 조절 기법)

  • Jung, Jinman;Yoon, Jisup;Yun, Young-Sun;So, Sunsup;Eun, Seongbae
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.16 no.1
    • /
    • pp.193-198
    • /
    • 2016
  • For environmental monitoring and risk identification of industrial plants, several monitoring systems using Wireless Sensor Networks (WSNs) have been developed. In this paper, we propose a dynamic duty cycle adjustment mechanism for reduced latency in industrial plants. The proposed method adjusts the duty cycle among predefined risk groups depending on the urgency of sensed data values. To demonstrate its efficacy, we analyze the expected transmission latency model and then discuss the characteristics in detail. We show that the proposed dynamic duty cycle mechanism is a more effective than a periodic mechanism by analyzing the expected latency of them in industrial plants where there are various types of sensory data with different levels of reliability.

Improvement Research of BLE-based System for Monitoring the cause of Breakdown of Automatic Doors (자동문의 고장원인을 모니터링하기 위한 BLE 기반의 시스템 개선연구)

  • Kim, Gi-Doo;Won, Seo-Yeon;Kim, Hie-Sik
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.54 no.7
    • /
    • pp.93-102
    • /
    • 2017
  • Recently increasing usage of smartphones makes the Internet of Things (IoT) a leading technology that can collect and share data through sensor networks and wireless communication such as low-power Bluetooth (BLE). BLE-based application can provide operators more precise information on Automatic Door system by remotely diagnosing the system faults through wireless sensor networks and sensors around the Automatic Door. In this paper, a smart device with extended BLE module is implemented which can monitor and Control the system states and faults remotely without on-site diagnostic. while maintaining system integrity so that increase efficiency of time and costs for system management. We can use the results of this research as a basis in evaluating reliability of data between devices, extending communication module in Controller of obsolete Door systems, and establishing centralized monitoring systems in near future with multi-channel Door Controls.

A Fuzzy AHP based Decision making Model for ground operations (지상작전수립을 위한 Fuzzy-AHP 기반의 의사결정 모델 연구)

  • Lee, Young-Kyun;Kim, Ki-Ang;Na, Hong-Bum;Park, Jin-Woo
    • Journal of the Korea Society for Simulation
    • /
    • v.17 no.4
    • /
    • pp.159-165
    • /
    • 2008
  • The ROK army has equipped ATCIS (Army Tactical Control Information System) for the Corps echelon to visualize the battlefield and reduce the reaction time. Due to the information&surveillance equipment, uncertainty and variance of the battlefield have been decreased. However decision making for the ground operations has not changed as it depends on knowledge of the commander and staffs. The War game process to select and assess the best CoA (Course of Action) also depends on the pros and cons due to the limitation of time and capability. For the balanced development between intangible and tangible military strength, a new decision making process which is quantitative and useful for the military is needed. In this study, we suggest a Fuzzy-AHP based decision making model to improve troop leading procedure which is useful to evaluate and reflect intangible characteristics of the battlefield.

  • PDF