• Title/Summary/Keyword: 전력감시

Search Result 638, Processing Time 0.022 seconds

Development of Power Quality Monitoring System (전력품질 감시 시스템 개발(3) : 전력품질 감시 시스템)

  • Bahng, Soon-Jeong;Kim, Young-Il;Han, Jin-Hee;Yoon, Tai-Wook
    • Proceedings of the KIEE Conference
    • /
    • 2003.11a
    • /
    • pp.158-160
    • /
    • 2003
  • Recently, with the increasing use of power semiconductors and microprocessors which are very sensitive to little change of power quality and for coping positively with anticipating power quality disputes between power providers and consumers which are possible to occur by of power market being formed, the power quality problem has gained preponderance among the contemporary research areas. To serve these purposes, this paper is described the integrated system for power quality monitoring, which provides speedy and powerful functions by analyzing the Event data and diverse graphic interfaces for user.

  • PDF

Internet Web-Based Rectifier Remote Control System Using SNMP (인터넷 웹 기반 환경에서의 정류기용 원격 제어 시스템)

  • 최주엽;오영은;전호석;김택용
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.4 no.6
    • /
    • pp.570-578
    • /
    • 1999
  • This paper aims at developing remote control system to control and monitor distributed various devices t through Internet or information communication network. SNJV!P(Simple Network l\ilanagement Protocol) and R Rectifier system with SN:\IP are adoptL'Cl for applied system with network management protocoJ, respectiveJy. F For controJling and monitoring distributed devices in realtime, Java environment software is constructed. Also g general--purpose interface controller between network device and applied device is pro[XJsed. The ProPOSL'Cl c controller is also able to control various devices with communication network remotely.

  • PDF

Development of an Integrated Control and Monitoring System for Emergency Power Generators (비상발전기 통합제어 및 감시시스템 개발)

  • 진강규;류길수;윤지근;유성호;김재환
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2001.05a
    • /
    • pp.192-196
    • /
    • 2001
  • These days, most of electric power facilities need high stability. Therefore integrated system has been required to monitor and control electronic power distribution system in fields at all times when the interruption of electric power has occurred. To construct this system, unit that convert and process the input signal from fields needed. And for control and monitoring from remote place MMI software is required. Lastly network equipments are required for real-time communications. So, in this paper, units for control and monitoring of emergency power generator and for electric power monitoring in normal electric power and interruption of electric power are developed. Also integrated remote system for monitoring in remote is developed.

  • PDF

Implementation and Test of GPS Jamming Monitoring Equipment (GPS 교란 감시 장치 구현 및 시험)

  • Joo, Inone;Lee, Jeom Hun;Lee, Sanguk;Kim, Jaehoon
    • Journal of Satellite, Information and Communications
    • /
    • v.8 no.4
    • /
    • pp.95-99
    • /
    • 2013
  • GPS service is generally being used in the navigation application such as the car navigation and the smart phone. Recently, GPS service continues to increase in the timing application such as the mobile telecommunication network, the smart grid, and the financial network. As GPS signals are sensitive to GPS jamming, it should be monitored and protected. In oder to prevent and minimize the damage caused by GPS jamming, many countries are developing and operating GPS jamming monitoring system. This paper presents the implementation and the test results of the GPS jamming equipment which provides the detection, the direction finding and the location of GPS jamming.

Development of Electric Safety Monitoring System and Cabinet Panel for Traditional Markets (재래시장 상가 분전반 및 전기안전감시시스템 개발 연구)

  • Kim, Gi-Hyun;Lee, Sang-Ick;Shin, Seong-Su;Bae, Suk-Myong
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.4
    • /
    • pp.123-128
    • /
    • 2010
  • In this paper, in order to reduce the electric disaster damage which is caused by with electric equipment of traditional markets, we developed cabinet panel and the electric safety monitoring system which is able to monitor the electrical equipments condition(over current, leakage, arc, WH, electrical fire factor etc.) at traditional markets. We constructed Test-bed for testing reliability of electric safety monitoring system and the actual condition investigation about electrical equipment of traditional market. This paper will be used with the data for an actual demonstration project after reinforcing problems which are occurred to operation of traditional market actual loads.

Application of the fiber-optic lattice fence systems for the electric power system significant building safety monitoring (전력 System 시설물 안전 감시용 광섬유 격자 그물망 구현을 위한 광섬유 시스템 적용성 연구)

  • Lee, Cheol-Kyou;Park, Yoon-Suk;Lee, Jong-Kil;Lee, June-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2001.07c
    • /
    • pp.1861-1863
    • /
    • 2001
  • 본 연구에서는 국내에서도 아직 초기단계 기술이라고 할 수 있는 간섭계를 이용한 주요 시설물(변전소등) 안전 감시 혹은 항만 감시 및 방어용 광섬유 격자 그물망 구현을 위한 광섬유 시스템 적용성을 연구한 것이다. 연구에서는 마흐젠더 간섭계의 구성에 비해 구성이 용이한 Sagnac간섭계를 구성 실험하였다. 이 간섭계의 성능 검증을 위하여 1550nm의 중심파장을 방사하는 레이저, 싱글모드 광섬유, 3${\times}$3 커플러 등의 광소자를 사용하였고, 광섬유의 길이의 변화를 주기 위하여 PZT 위상 변조기에 교류 전원을 인가하여 PZT 위상 변조기의 진동을 유도하였다. 또한, 전체 길이 약 180cm, 17${\times}$7, 철봉의 직경 6m의 철망 구조물을 제작후, 센서 부분의 역할을 담당한 광섬유 케이블을 일정한 간격으로 철망 구조물에 케이블 타이로 고정하였다. 철망 구조물에서 발생할 수 있는 각종 외부 가진에 대해, 철망 구조물에 가속도계를 설치하여, Sagnac 간섭계에서의 광 간섭 신호와 가속도계의 신호를 비교 검증 하였다. 본 실험결과를 통하여 광섬유 펜스는 주요 시설물(변전소등) 안전 감시 혹은 항만 감시 및 방어용 경보 시스템에 적합하다고 판단된다.

  • PDF

Performance Analysis of the Powerline Communication for Condition Monitoring System of an MW Class Offshore Wind Turbine's Nacelle (MW급 해상풍력발전기 나셀의 상태 감시를 위한 전력선 통신 성능 분석)

  • Sohn, Kyung-Rak;Kim, Kyoung-Hwa;Jeong, Seong-Uk;Nam, Seung-Yun;Kim, Hyun-Sik
    • Journal of Navigation and Port Research
    • /
    • v.40 no.3
    • /
    • pp.159-164
    • /
    • 2016
  • The goal of this study is to implement a communication system that can monitor the status of the nacelle using the power cable itself, without the dedicated communication lines such as an UTP cable and optical fiber for the offshore wind turbine. An inductive coupling powerline communication system for a MW class offshore wind turbine was proposed and its communication performance was demonstrated. The inductive couplers was designed for operation at up to 500 A using a ferrite composite materials. Field test was carried out on the wind farms of Jeju island. Using the iperf communication test program, we have obtained more than 15 Mbps data transmission rate through the 100 m power cable that was installed between the nacelle and the bottom of the power converter. In the data transmission stability test for a week, there was no failure ever. The minimum transmission rate was 15 Mbps and the average data rate was about 20 Mbps. Next, we have installed an infrared camera inside the nacelle in order to measure the temperature distribution and variation of the nacelle. The real-time thermal image taken by the camera was successfully sent to the monitoring system without error.