• Title/Summary/Keyword: 전달하중

Search Result 584, Processing Time 0.028 seconds

A Study on the Anti-impulsive Strength of the Helmets for a Gas Industry (가스산업용 안전모의 내충격 안전성에 관한 연구)

  • Kim, Chung Kyun;Kim, Tae Whan
    • Journal of the Korean Institute of Gas
    • /
    • v.17 no.6
    • /
    • pp.52-57
    • /
    • 2013
  • In this study, the strain energy density, stress and deformation behaviors have been analyzed as functions of a thickness and a force area of protective helmets with and without an extruder on the top of the shell structure using the finite element method. The strain energy density in which is related to the absorption capacity of an impact energy transfer is one of a key element of the helmet safety. The FEM analyzed results show that when the impulsive force of 4,540N is applied on the top surface of the helmets, the maximum stress is linearly reduced for an increased area of impact forces. But, the maximum strain energy density has been reduced for the increased force area. The reduced strain energy density may increase the impulsive forces transferred to the head and neck of helmet wearers, which may decrease the impact energy absorption safety of the helmets. In thus, it is safer design of the helmet in which has an extruded structure on the summit surface, but the modified helmet may decrease the impact energy absorption capacity.

An Estimation of the Fatigue Behavior on the Cruciform Type Specimen by Variation of the Stress Ratio (응력비 변화에 따른 십자형 접합부의 피로거동 평가)

  • 김태봉;서상구;우상익
    • Journal of the Korean Society of Safety
    • /
    • v.15 no.1
    • /
    • pp.140-145
    • /
    • 2000
  • This paper was composed with fatigue test of the cruciform specimens, as load carrying and non-load carrying type. It also has performed computational analyses for geometric condition of the fillet welding bead. As test results, the effect of stress ratio in the specimen was insignificant. Stress ranges were varied with R=0.1~0.2. The fatigue cracks that were found in the load carrying type specimens and most specimens welded with contact were developed at the end of welds. The fatigue strength of specimen that have fractured in maternal plate was found about ${\Delta}\sigma_c$=63.5MPa. It's about 24% less than that of the non-load carrying type specimens having about ${\Delta}\sigma_c$=83.8MPa. A category of the Fatigue design specifications which provide for cruciform details was defined grade C as a stress of the maternal member. And then, the fatigue strength to be transformed into the maternal stress was found about 78.27 MPa, it tends to be less than that of allowable fatigue strength.

  • PDF

Study on Analysis of Skew Grillage Girder Bridges by Transfer Matrix Method (전달행렬법에 의한 경사 격자교의 해석에 관한 연구)

  • Kim, Yong-Hee;Lee, Yoon-Young;Kim, Kwang-Ho
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.9 no.1
    • /
    • pp.159-170
    • /
    • 2005
  • The grid structure is parallel main girders intersected with crossgirder. It distribute the loads to adjoining main girder through the crossgirder when a girder is subjected to a load. grillage girder bridge has high load-carrying capacity, it can save materials and become more economical type of bridge. In this paper, the grillage girder bridge analysis program developed by using the transfer matrix method deals with following problems: the comparision with Leonhardt, Szabo, FEM yang and jung in the analysis of grillage girder bridges, quality of straight and curved bridges with skew angle, forces of straight and curved bridges according to skew angle and bending stiffness/torsional stiffness ratio.

Numerical Study on the Effects of Geosynthetic Reinforcement on the Pile-supported Embankment (수치해석을 통한 성토지지말뚝에 대한 토목섬유 보강 효과 분석)

  • Lee, Su-Hyung
    • Journal of the Korean Society for Railway
    • /
    • v.12 no.2
    • /
    • pp.276-284
    • /
    • 2009
  • Recently pile-supported embankments have emerged as an optimum method when the rapid construction and strict deformation of structures are required on soft soils. Especially geosynthetic-reinforced and pile-supported (GRPS) embankments are used worldwide as they can provide economic and effective solutions. However the load transfer mechanism in GRPS embankments is very complex, and not yet fully understood. Particularly the purpose and effect of geosynthetic inclusion are ambiguous and considered as an auxiliary measure assisting the arching effect of piles. Numerical parametric study using 3D finite element method has been conducted to investigate the effect of geosynthetic reinforcement on the load transfer mechanism of GRPS embankments. Numerical results suggested that as more stiffer geosynthetic is included, arching effect decreases considerably and the load concentration to the piles mostly caused by tension effect of geosynthetic. This finding is contradictory to the common understanding that geosynthetic inclusion only enhance the efficiency of load transfer. Consequently the design parameters determined from the numerical analyses are compared with those of three existing design methods. The problems of the existing methods are discussed.

A Study on the Helicopter Composite Blade Impact Loads (헬리콥터 복합재 블레이드 충돌하중 연구)

  • Lee, Hyun-Cheol;Jeon, Boo-Il;Moon, Jang-Soo;Yee, Seok-June
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.37 no.2
    • /
    • pp.181-186
    • /
    • 2009
  • The objective of this study is ensuring safety of cabin when the blade impacts into a obstacle by verifying safety of the rotor mast and the transmission using impact loads calculated from the simulation. The rotor mast shall not fail and the transmission shall not be displaced into occupiable space when the main rotor composite blade impact into a 8 inch rigid cylinder in diameter on the outer 10% of the blade at operational rotor speed. To calculate the reaction loads at the spherical bearing and lead-lag damper, blade impact analysis was performed with FE model consist of composite blade, tree(or rigid cylinder) using elastic-plastic with damage material and several contact surfaces which were created to describe a progress of actual failure. Also, the reaction loads were investigated in change of blade rotation speed and pitch angle.

Load Transfer Mechanism of the Hybrid Beam-Column Connection System with Structural Tees (T 형강을 사용한 합성골조 보-기둥 접합부의 하중전달 메카니즘)

  • 김상식;최광호
    • Journal of the Korea Concrete Institute
    • /
    • v.14 no.6
    • /
    • pp.823-829
    • /
    • 2002
  • The composite frame system with reinforced concrete column and steel beam has some advantages in the structural efficiency by complementing the shortcomings between the two systems. The system, however has also a lot of problems in practical design and construction process due to the material dissimilarities. Considering these circumstances, this research is aimed at the development of the composite structural system which enables the steel beams to be connected to the R/C columns with higher structural safety and economy. Basically the proposed connection system is composed of four split tees, structural angles reinforced by stiffener, high strength steel rods, connecting plates and shear plates. The structural tests have been carried out to verify the moment transfer mechanism from beam flange to steel rods or connecting plates through the angle reinforced by siffener. The four prototype specimens have been tested until the flange of beam reached the plastic states. From the tests, no distinct material dissimilarities between concrete and steel have been detected and the stress transfer through wide flange beam - structural angle - high strength steel rod or connecting plate is very favorable.

Estimation of Group Walking Loads by System Identification of Building Structures (건축구조물의 시스템 식별을 통한 무리보행하중 평가)

  • 김태호;민경원;이동근
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.7 no.1
    • /
    • pp.65-72
    • /
    • 2003
  • The objective of this study is to estimate the frequency characteristics of group walking loads based on the information of measured responses. At first, dynamic properties such as natural frequencies and modes are obtained from input/output relation for building structures by heel drop test. Second, a method to estimate group walking loads by the transfer functions from measured responses to group walking loads is proposed. The method turned out to estimate the group walking loads accurately. Higher modes could be important in estimating the amplitude of group walking loads with the information of single walking load.

Wave Propagation on a High-speed Railway Embankment Using a Pile-slab Structure (파일슬래브구조가 적용된 고속철도 토공노반에서의 진동 전파)

  • Lee, Il Wha;Lee, Sung Jin;Lee, Su Hyung;Lee, Kang Myung
    • Journal of the Korean Society for Railway
    • /
    • v.16 no.4
    • /
    • pp.278-285
    • /
    • 2013
  • The suppression of residual settlement is required on earthwork sections as concrete track is introduced. Use of pile-slab structure is one of the settlement restraining methods applied on soft ground. The slab distributes the upper embankment load and piles transfer the load from the slab to the stiff ground. While this method is very effective in terms of load transfer, it has not yet been established for dealing with the vibration transfer effects and interaction characteristics between a structure and the ground. It is possible that vibration caused by a moving train load is propagated in the upper embankment, because the slab acts as a reflection layer and waves are multi-reflected. In this present paper, wave propagation generated by a moving train load is evaluated in the time and frequency domains to consider a roadbed structure using an artificial impact load and field measured train load. The results confirmed the wave reflection effect on the pile-slab structure, if the embankment height is sufficient, vibration propagation can be stably restrained, whereas if the height is not sufficient, the vibration amplitude is increased.

Structural analysis and selection of strain gauge point of chisel and disk harrow arm for unpowered disk harrow working implement (무동력 디스크해로우 작업기의 치즐 및 디스크해로우암의 구조해석 및 스트레인 게이지 위치 선정)

  • Shin, InKyung;Park, Young-Jun;Gang, GaAe;Han, JeongWoo
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2017.04a
    • /
    • pp.16-16
    • /
    • 2017
  • 국내 농업인구 감소 대비 식품소비량이 증가함에 따라 농가의 인력을 대체하고 다양한 작업이 가능하며 가격이 저렴한 국내 기계화 기술이 필요하다. 무동력 디스크해로우 작업기는 경운과 배토가 가능한 복합작업기로서 작업기를 구성하는 주요 구성품들은 필드작업에 의해 발생되는 하중에 구조적 강도와 신뢰성이 충분히 확보되어야 한다. 또한, 실제로 필드 작업 시 작업기에 걸리는 하중은 복합하중 형태로 전달되기 때문에 단순한 형태 하중에 비해 하중계측에 어려운 점이 있으므로 하중계측점의 선정이 매우 중요하다. 본 논문에서는 하중계측점을 선정하기 위하여 복합기의 주요 구성품인 치즐(chisel) 및 디스크해로우암(disk harrow arm)에 대하여 구조해석을 수행하였으며, 3축 방향의 단위하중 응력 계산결과로부터 load reconstruction을 위한 스트레인 게이지 위치를 선정하였다. 또한, 스트레인 게이지의 신호가 하중해석에 적절한 값이 되도록 기존의 형상을 수정하였다.

  • PDF

An Structural Design for Cyclone Tower's Connections Using Diagrid System (다이아그리드 구조시스템의 접합부개발과 성능평가)

  • Lee, Se-Jung;Lee, Seong-Hui;Kim, Jin-Ho;Choi, Sung-Mo
    • Journal of Korean Association for Spatial Structures
    • /
    • v.10 no.2
    • /
    • pp.105-115
    • /
    • 2010
  • Recently, High-rise building are irregular-shaped to be city landmarks and function as vertical cities to enable the efficient use of land. 3T (Twisted, Tilted & Tapered) designs are being suggested for irregular buildings and studies to develop new structural system have been actively made to satisfy slender shape ratio. In diagrid system, not only gravity load but also lateral load is delivered based on the triangular shape of diagrid, so most of columns are eliminated. Because shearing force is delivered by the axial behavior (tensile/compressive) of diagrid to minimize shearing deformation, the system is more applicable to irregular buildings than existing system where shearing force is delivered by the columns. In this study, the process of selecting connection details and the structural safety of the selected details are verified using the finite element analysis with focus given to the construction overview of the Cyclone Tower. However, the relersed methods of stress concentration are suggested and the performance of stress concentration relieves that it's suggested for the appropriate cap plate thickness and extended length.