• Title/Summary/Keyword: 전단 성능

Search Result 1,123, Processing Time 0.039 seconds

Strain-Based Shear Strength Model for fiber Reinforced Concrete Beams (섬유보강 콘크리트 보를 위한 변형 기반 전단강도모델)

  • Choi Kyoung-Kyu;Park Hong-Gun;Wight James K.
    • Journal of the Korea Concrete Institute
    • /
    • v.17 no.6 s.90
    • /
    • pp.911-922
    • /
    • 2005
  • A theoretical study was performed to investigate the behavioral chracteristics and shear strength of fiber reinforced concrete slender beams. In the fiber reinforced concrete beam, the shear force applied to a cross section of the beam was resisted by both compressive zone and tensile zone. The shear capacity of the compressive zone was defined addressing the interaction with the normal stresses developed by the flexural moment in the cross section. The shear capacity of the tensile zone was defined addressing the post-cracking tensile strength of fiber reinforced concrete. Since the magnitude and distribution of the normal stresses vary according to the flexural deformation of the beam, the shear capacity of the beam was defined as a function of the flexural deformation of the beam. The shear strength of the beam and the location of the critical section were determined at the intersection between the shear capacity and shear demand curves. The proposed method was developed as a unified shear design method which is applicable to conventional reinforced concrete as well as fiber reinforced concrete.

Structural Behavior of Reinforced Concrete Beams using High Strength Shear Reinforcement (고강도 전단보강 철근을 사용한 철근콘크리트 보의 거동평가)

  • Choi, Im-Jun;Park, Jong-Wook;Hwang, Hyun-Bok;Lee, Jung-Yoon
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2009.05a
    • /
    • pp.3-4
    • /
    • 2009
  • This study predicts the structural behavior of RC beams using high strength shear reinforcement and evaluates current design codes restricting the strength of shear reinforcement steel. Under the present design codes, the yield strength of shear reinforcement steel is restricted to 400MPa. In case that use high yield strength reinforcement steel, could incure heavily crack and deflection at the members of structure, and have not verified ductility capacity, fatigue resisting capacity, shear and torsion resisting capacity, anchoring capacity and seismic capacity. To this end, we evaluate structural behavior of reinforced concrete beams using high strength shear reinforcement.

  • PDF

Shear Capacity of Composite Basement Walls (합성 지하벽의 전단성능)

  • 김성만;이성호;서수연;이리형
    • Journal of the Korea Concrete Institute
    • /
    • v.14 no.3
    • /
    • pp.321-330
    • /
    • 2002
  • This paper presents the experimental results of composite basement wall in which H-pile and reinforced concrete wall are combined using shear connector Twelve specimens are tested to evaluate the shear capacity of the wall. Main variables in the test are composite ratio, distribution of shear connector, thickness of wall, shear-span ratio, and shear reinforcement. Test results indicate that the shear capacity of test specimens varies with the foregoing variables except the composite ratio. The results are compared with strengths predicted using the equations of ACI 318-99, Zsutty, and Bazant. Based on this investigation, a method for predicting the shear strength of composite basement walls is proposed.

Cyclic Lateral Load Test on the Punching Shear Strength and the Lateral Displacement Capacity of Slab-Column Connections (슬래브-기둥 접합부의 펀칭강도 및 횡변위 성능에 관한 반복 횡하중 실험)

  • Choi, Jung-Wook;Song, Jin-Gyu;Kim, Jun-Hee
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.11 no.4
    • /
    • pp.99-108
    • /
    • 2007
  • In the flat-plate slab design of the KCI and ACI building code, the punching shear strength of connections with shear reinforcement can increase one and half times to that of connections without shear reinforcement. And the ACI-ASCE committee 352 recommendations propose limiting the direct shear ratio $V_g$/$V_c$ on interior connections to 0.4 to insure adequate drift capacity. In this study, four interior column-slab connections were tested to look into the punching shear strength and the lateral displacement capacity of the flat-plate slab with and without shear reinforcement under cyclic lateral loading. Based on the test results, it is found that the provision about punching shear strength in the codes may appropriate for the gravity loading only whereas it is unconservative for the lateral loading and that the limit of ACI-ASCE committee 352 appears conservative.

An Analysis on Punching Shear of Two-way Void Slab (이방향 중공슬래브-기둥 접합부 뚫림전단성능의 해석적 평가)

  • Lee, Yung Eun;Ryu, Jaeho;Ju, Young Kyu;Kim, Sang Dae
    • 한국방재학회:학술대회논문집
    • /
    • 2011.02a
    • /
    • pp.32-32
    • /
    • 2011
  • 최근 국내외에서 친환경건축물에 관한 관심이 매우 높아짐으로 인해 콘크리트의 물량을 절감하여 이산화탄소량을 줄이는 중공슬래브는 다양한 형태로 세계적으로 개발이 되고 있는 추세이다. 특히 이방향 중공슬래브는 환경적인 측면에서 이방향 중공슬래브는 중공부 생성에 재생플라스틱을 활용하여 폐자원을 재사용하고, 콘크리트와 철근의 사용량 절감에 따른 화석에너지 및 이산화탄소 발생량을 감소한다는 장점이 있다. 또한 시스템 측면에서 이방향 중공슬래브는 기존의 철근콘크리트 플랫플레이트 바닥구조 시스템의 자중을 절감하여 구조체를 경량화 시키고, 이에 따라 장스팬 구현이 가능하며, 단열효과가 뛰어나다. 이와 같이 이방향 중공슬래브는 장점이 많지만 플랫플레이트 슬래브의 취약점인 뚫림전단 파괴에 주의해야 한다. 이에 본 연구에서는 선행으로 실시된 이방향 중공슬래브-기둥 접합부 뚫림전단 성능평가 실험을 바탕으로 하여 경량체가 이방향 중공슬래브-기둥 접합부 뚫림전단 성능에 미치는 영향을 살펴보기 위해 범용 유한요소해석 프로그램인 ABAQUS를 사용하여 경량체량 및 위치를 주요변수로 한 해석적인 변화를 검토하였다. 본 연구를 통해 경량체가 삽입된 이방향 중공슬래브의 뚫림전단 성능에 대해, 해석결과 경량체 량과 위치에 따라 최대 뚫림전단강도는 기준 실험체에 비해 74.3%, 73%의 강도저하를 나타내는 것으로 알 수 있었다. 이는 실험상의 강도저하 값인 84.1%, 56.4%와 다소 차이가 있으며, 해석에서 중공부 주위의 응력집중 현상이 제대로 반영되지 않은 것으로 판단된다. 또한 이방향 슬래브에 경량체를 삽입 할 경우 경량체가 시작하는 부분에서 응력이 급격히 감소하는 현상이 나타났으며, 이러한 급격한 응력감소는 기둥 주위 위험단면의 변화를 가져오는 것으로 추정된다. 즉, 위험단면의 변화는 기둥으로부터 경량체 사이의 거리에 따라 달라지며, 위험단면 내의 콘크리트 단면 손실은 뚫림전단 강도를 감소시킨다. 본 연구에서는 이방향 중공슬래브의 뚫림전단강도를 산정할 수 있는 근사식을 제안하였으며, 보다 정확한 이방향 중공슬래브의 뚫림전단강도의 산정식을 위해서는 위험단면의 변화와 콘크리트 단면손실로 인한 전단강도 저하의 관계에 대한 추가적인 연구가 필요하다.

  • PDF

Strain-Based Shear Strength Model for Prestressed Concrete Beams (프리스트레스트 콘크리트 보를 위한 변형률 기반 전단강도 모델)

  • Kang, Soon-Pil;Park, Hong-Gun
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.197-200
    • /
    • 2008
  • An analytical model for predicting the shear strength of prestressed concrete beams was developed, applying the previously proposed strain-based shear strength model. In flexure-compression member without shear reinforcement, compression zone of intact concrete primarily resist to the shear force rather than tension zone. The shear capacity of concrete at the compression zone was defined based on the material failure criteria. The shear capacity of the compression zone was evaluated along the inclined failure surface considering interaction with the normal stress. Since the distribution of normal stress varies due to the flexural deformation of member, the shear capacity was defined as a function of the flexural deformation. Finally, the shear strength was determined at the intersection of the shear capacity curve and the shear demand curve. As a result of the comparisons to prior test data, the proposed model accurately predicted the shear strength of specimens.

  • PDF

Racking Property of Light-framed Shear Wall with Hold-down Connector (홀드다운을 적용한 경골목조 벽체의 전단성능)

  • Lee, In-Chan;Park, Chun-Young;Lee, Jun-Jae
    • Journal of the Korean Wood Science and Technology
    • /
    • v.36 no.4
    • /
    • pp.26-36
    • /
    • 2008
  • As the height of the light-framed building increases, the lateral load and overturn-moment are increased and the possibility of the building overturn becomes larger. Because the shear wall resists lateral load in light-framed building, the reinforcement of shear wall is required. In order to reinforce the light-framed shear wall, using lag screw fastener type (B-HD) and using bolt type (S-HD) hold-down connectors were applied for test. And domestic larch lumbers, $38{\times}140mm$ and $89{\times}140mm$, KS 2nd grade, were used for the stud. The North American OSB panels were used for sheathing panel. Static loads, load speed 6 mm/min, were applied on top of the wall. As a result, shear strength of the wall that using hold-down connector was improved sufficiently. And when applying the S-HD type hold-down connector, stud should be reinforced against weakening by drilled hole. As increasing the number of lag screw, the number of bolt and the product allowable strength, the strength of shear wall that using hold-down connector was also increased. When applying hold-down connector to light-framed building using 38 mm stud, it must be reinforced by enlarging the thickness of stud like as 38 mm doubled column.

Punching Shear Strength of Slab-Column Interior Connection Considering Anchorage Performance of Shear Reinforcements (전단보강재의 정착성능을 고려한 슬래브-기둥 내부접합부의 뚫림전단강도)

  • Jung, Hyung-Suk;Choi, Hyun-Ki;Chung, Joo-Hong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.26 no.2
    • /
    • pp.51-58
    • /
    • 2022
  • Flat plate slab is cost-efficient structural system widely used in high rise building, apartment and parking garages. But flat plate-column connections are so weak against punching shear failure that it may cause collapse of overall structure. In this study, spiral type shear reinforcement which increases the shear strength and ductility of the plate-column connection and has good workability was proposed. And experimental test was performed to verify the punching shear capacity of spiral type shear reinforcement. The current code does not accurately estimate the punching shear strength of slab-column connection with shear reinforcement because slab is so slender that punching failure may occurred before shear reinforcement reached yield stress. Therefore modified equation of ACI code for punching shear strength was proposed base on finite element analysis using LUSAS program, and data analysis from CEB-FIP database.

A Study on the Shear Fatigue Performance of Elastomeric Bearings of a Doublefold Elastomeric Layer (고무의 겹침제작 여부에 따른 탄성받침의 전단피로특성 연구)

  • Yoon, Hye-Jin;Kwahk, Im-Jong;Kim, Young-Jin
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.69-72
    • /
    • 2008
  • Bridge bearings are devices absorbing the displacements of the superstructure. Elastomeric bearings used generally as bridge bearings absorb the displacements of the superstructure using their rubber characteristics. Elastomeric bearings should make sure their shear fatigue performance not to impede the durability of bridge system. In this paper shear fatigue tests were performed and stiffness were measured through the shear fatigue tests. Tests results show the measured stiffness of elastomeric bearings have no specific tendency. This paper found that elastomeric bearings show bad shear performance or fail early if elastomeric bearings are manufactured with a doublefold elastomeric layer.

  • PDF

Seismic Performance of Shear Dominant Hybrid Steel Link Beam with Circular Web Opening (원형 개구부가 있는 전단지배 하이브리드 강재 연결보의 내진성능)

  • Lim, Woo-Young
    • Journal of Korean Society of Steel Construction
    • /
    • v.30 no.1
    • /
    • pp.37-48
    • /
    • 2018
  • Cyclic loading tests for shear dominant hybrid steel link beams with circular web openings were performed to evaluate the seismic performance. Four half-scaled specimens with bolted connections were tested. The test parameter is a diameter of the web opening, i.e., shear strength ratio ($V_{pw}/V_p$) of the link beam and presence of top-seat angles. Using test results, adequate design shear strength of link beam was finally suggested. Test results showed that when the shear capacity is less than half of the plastic shear strength, seismic performance was improved due to mitigation of pinching under reversed cyclic inelastic deformations.