• Title/Summary/Keyword: 전단무보강

Search Result 48, Processing Time 0.027 seconds

Punching Shear Performance Evaluation of Foundation by Enforcement-length of Shear Head Reinforcement (전단 보강재의 보강길이에 따른 기초판의 뚫림전단 성능평가)

  • Lee, Yong-Jae;Yi, Waon-Ho;Yang, Won-Jik
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.21 no.2
    • /
    • pp.60-68
    • /
    • 2017
  • This study was made to examine the motion characteristics according to the reinforcement of the reinforcement length and stiffener reinforcement for shear reinforcement to the foundation structure reinforced with shear reinforcement steel plate. Experimental study was made after specimen was installed on the ground as the same as in the practical site. Reinforcement lengths of the steel for shear reinforcement are divided into 1,000 mm, 1,200 mm and 1,400 mm in the specimen and as for reinforcement method of the stiffener, 4 stiffeners with interval of 100mm reinforced with the same materials as the shear reinforcement were manufactured for the experiment. Considering result of the experiment, it is expressed that no effect of the stiffener reinforcement was found and regarding the reinforcement length of shear reinforcement material the crossed point of the two converted lines of the value that the shear force is expressed in the bearing power in the expanded dangerous section and the value that the shear capacity receivable by the reinforcement materials in the dangerous section is proposed as effective reinforcement length.

Shear Strength Prediction of FRP RC Baem without Shear Reinforcements (전단 보강이 없는 FRP RC보의 전단강도 예측)

  • Lee, Jae-Hoon;Shin, Sung-Jin
    • Journal of the Korea Concrete Institute
    • /
    • v.22 no.3
    • /
    • pp.313-324
    • /
    • 2010
  • There are many problems in application of FRP reinforcing bars as shear reinforcement, since bending of FRP bars is not a feasible process on construction site. Even though FRP bars can be manufactured in bent shape, they have lower strength at bent location. However, there are no serious problems to use FRP bars as flexural reinforcement. Plates or slabs like bridge decks, in general, do not need shear reinforcements. These types of members with FRP flexural reinforcement have lower shear strength than those with conventional steel flexural reinforcement. However, reliable process or equation for shear strength estimation of FRP reinforced concrete without shear reinforcement are not established, yet. In this study, predicted shear strength obtained from available design equations and assessment equations are compared with 211 experimental results. The results showed that among the current design codes, the Architectural Institute of Japan (AIJ) and the Institution of Structural Engineers (ISE) provided the best estimation. ACI 440.1R-06 provided conservative results with degree of dispersion similar to that of ISE. In addition, regression analysis on the collected experimental results was conducted to develop regression models. As a result, a new reliable shear strength equation was proposed.

Comparison of Shear Properties of Crumb Rubber-Bottom Ash Mixture Considering Reinforcement Types of Waste Fishing Net (폐어망 보강형식에 따른 폐타이어-저회 혼합토의 전단특성 비교)

  • Kwon, Soon-Jang;Kim, Yun-Tae;Ahn, Jae-Hoon
    • Journal of the Korean Geotechnical Society
    • /
    • v.28 no.9
    • /
    • pp.47-55
    • /
    • 2012
  • This paper investigates the shear properties of crumb rubber-bottom ash mixture reinforced by waste fishing net (WFN). Mixtures used in this experiment consist of crumb rubber and bottom ash (2mm~10mm) with the same weight ratio. In this study several series of direct shear tests were carried out on the five different specimens : unreinforced mixture, reinforced mixtures with 1 or 2 single-layered WFN, reinforced mixtures with 1 or 2 double-layered WFN. The experimental results indicated that the shear properties of reinforced crumb rubber-bottom ash mixture were strongly influenced by reinforcing layer of WFN. It was found that the shear strength and internal friction angle of the mixtures increased with an increase in reinforcing layer of WFN due to interlocking effect and friction between mixture and WFN.

Nonlinear Dynamic Properties of Fiber Reinforced Soils (섬유혼합토의 비선형 동적물성치)

  • 박철수;황선근;목영진
    • Journal of the Korean Geotechnical Society
    • /
    • v.19 no.2
    • /
    • pp.189-197
    • /
    • 2003
  • In this paper, deformation characteristics of fiber-mixed-soils were studied at small strain range(0.0001%~1%) using resonant column test and triaxial test, and reinforcement effect was evaluated by the measure of maximum shear moduli. The effects of the major parameters such as fiber content, aspect ratio and fiber type on reinforcement were comparatively assessed. The specimens were remolded from Jumunjin Sand randomly mixed with discrete polypropylene staple fibers. Maximum shear moduli of fiber-mixed-soils increased by up to 30% and modulus reduction was also restrained in nonlinear range. Shear moduli increased as the aspect ratio increases. The reinforcement was more effective with fibrillated fiber than with monofilament fiber. The most effective reinforcement was achieved with the specimen of 0.3 % fiber content.

Experimental Study for GFRP Reinforced Concrete Beams without Stirrups (스터럽이 없는 GFRP 보강근 콘크리트 보에 대한 실험적 연구)

  • Ko, Seong-Hyun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.18 no.2
    • /
    • pp.21-29
    • /
    • 2014
  • This paper evaluates the shear strength, behavior and failure mode of reinforced concrete beams with deformed GFRP reinforcing bar. Four concrete beam specimens were constructed and tested. It was carried out to observe failure behavior and load-deflection of simply supported concrete beams subjected to four-point monotonic loading. In order to eliminate of the uncertainty by the shear reinforcements, any stirrups were not used. Variables of the specimens were shear span-depth ratio, effective reinforcement ratio. The dimensions of specimen is 3,300 or $1,950mm{\times}200mm{\times}240mm$. Clear span and shear span were 2,900mm, 1,000mm respectively. Shear span-depth ratios were 6.5 and 2.5. Effective ratios of Longitudinal GFRP reinforcing bar were $1.126{\rho}_{fb}$, $2.250{\rho}_{fb}$, $3.375{\rho}_{fb}$ and $0.634{\rho}_{fb}$. All beam specimens were broken by diagonal-tension shear and the ACI 440.1R, CSA S806 and ISIS, which was used to design test beams, showed considerable deviation between prediction and test results of shear strengths.

Structural Performance of Reinforced Concrete Shear Columns Strengthened with Sprayed Fiber Reinforced Polymers (Sprayed FRP로 보강된 철근 콘크리트 전단기둥의 보강성능 평가)

  • Lee, Kang Seok;Byeon, In Hee;Lee, Moon Sung
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.11 no.3
    • /
    • pp.132-142
    • /
    • 2007
  • In this study, a structural performance of R/C columns controlled by shear, strengthened with Sprayed FRP, was investigated. For this purpose, six 2/3-scaled column specimens were designed and tested by the pseudo-static reversed cyclic load under a constant axial load, which is 10% of the nominal axial strength of the column. Four specimens were strengthened by Sprayed FRP with different combinations of short fibers (carbon or glass) and resins (epoxy or vinyl ester). For comparison purpose, tests of a specimen strengthened with carbon fiber sheet (CFS) and a control specimen without strengthening were carried out, respectively. The result reveals that shear strengths and ductility capacities of columns strengthened with Sprayed FRP improved remarkably, compared to those of the control column, and the Sprayed FRP technique developed in this study is able to use the strengthening scheme of existing R/C columns.

Failure Behavior of FRP RC Beams without Shear Reinforcements (전단 보강이 없는 FRP RC보의 파괴 거동)

  • Lee, Jae-Hoon;Son, Hyun-A;Shin, Sung-Jin
    • Journal of the Korea Concrete Institute
    • /
    • v.22 no.2
    • /
    • pp.199-208
    • /
    • 2010
  • In order to substitute FRP bar for steel bar in new structures, it is necessary to establish a reliable design code. But relatively little research has been conducted on the material in Korea. So, a total of 22 beam specimens (18 GFRP reinforced concrete and 4 conventional steel reinforced concrete) were constructed and tested. In the first phase of the experiment, it was carried out to observe flexural behavior, and collect deflection and crack data. In order to eliminate of the uncertainty by the shear reinforcements and induce flexural failure mode, any stirrup were not used and only shear span-depth ratio were adjusted. However, almost beams were broken by shear and the ACI 440.1R, CSA S806, which were used to design test beams, showed considerable deviation between prediction and test results of shear strengths. Therefore in the second phase of the study, shear failure modes and behavior were observed. A standard specimen had dimensions of 3,300 mm long ${\times}$ 800 mm wide ${\times}$ 200 mm effective depth. Clear span and shear span were 2,800 mm, 1,200 mm respectively. Control shear span-depth ratio was 6.0. Four-point bending test over simple support was conducted. Variables of the specimens were concrete compressive strength, type and elastic modulus of reinforcement, shear span-depth ratio, effective reinforcement ratio, the effect of bundle placing method and cover thickness.

Shear Capacity of Reinforced Concrete Continuous T-Beams Externally Strengthened with Wire Rope Units (와이어로프로 외부 보강된 철근콘크리트 연속 T형 보의 전단내력)

  • Yang, Keun-Hyeok;Sim, Jae-Il;Byun, Hang-Yong
    • Journal of the Korea Concrete Institute
    • /
    • v.19 no.6
    • /
    • pp.773-783
    • /
    • 2007
  • A simple unbonded-type shear strengthening technique for reinforced concrete beams using wire rope units is developed. Six two-span continuous T-beams externally strengthened with wire rope units and an unstrengthened control beam were tested. The main variables investigated were the amount and prestressing force of wire rope units. All specimens had the same geometrical dimension and arrangement of internal reinforcement. Influence of the distribution of vertical stresses in beam web owing to the prestressing force of wire rope units on the diagonal shear cracking load and the ultimate shear capacity of beams tested is presented. Based on the current study, it can be concluded that the amount and initial prestress of wire rope should be limited to be above 2.5 times the minimum shear reinforcement ratio specified in ACI 318-05 and below 0.6 times its own tensile strength, respectively, to ensure the enhancement of shear capacity and ductile failure mode of the strengthened beams. A numerical analysis based on the upper-bound theorem is developed to assess the shear capacity of continuous T-beams strengthened with wire rope units. From the comparisons of measured and predicted shear capacities, a better agreement is achieved in the proposed numerical analysis than in empirical equations recommended by ACI 318-05.

A Study on Rainfall-induced Erosion of Land Surface on Reinforced Slope Using Soil Improvement Material (지반 개량재에 의한 보강사면의 강우시 표면침식에 관한 연구)

  • Kim, You-Seong;Kim, Jae-Hong;Bhang, In-Hwang;Seo, Se-Gwan
    • Journal of the Korean Geotechnical Society
    • /
    • v.29 no.1
    • /
    • pp.49-59
    • /
    • 2013
  • Heavy rainfall intensity may cause shallow slope failures and debris flow by rill erosion and scour on land surface. The paper represents the difference between native soil (weathered soil) and reinforced soil, which is mixed by hardening agent with flyash as main material, for investigating experimental findings of rill erosion and erosion. Results obtained from artificial rainfall simulator show that erosion rate of reinforced soil mixed with hardening agent is reduced by 20% because an amount of eroded soil on slope surface is inversely proportional to the increase of soil strength. For example, rainfall of 45mm (at the elapsed time of 25mins in rainfall intensity of 110mm/hr) triggers rill erosion on native soil surface, but the rill erosion on reinforced soil surface does not even occur at 330mm rainfall (at the elapsed time of 3hrs in rainfall intensity of 110mm/hr). As a result of slope stability analysis, it was found that the construction method for reinforced soil surface would be more economical, easy and fast construction technology than conventional reinforcement method.

Evaluation of Load Capacity and Toughness of Porous Concrete Blocks Reinforced with GFRP Bars (GFRP 보강 다공성 콘크리트 블록의 내력 및 인성 평가)

  • Jung, Seung-Bae;Yang, Keun-Hyeok
    • Journal of the Korea Institute of Building Construction
    • /
    • v.17 no.5
    • /
    • pp.403-409
    • /
    • 2017
  • In this study, mix proportioning of porous concrete with compressive strength and porosity exceeding 3MPa and 30%, respectively, was examined and then load capacity and flexural toughness of the porous concrete block were evaluated according to the different arrangements of the GFRP bars. To achieve the designed requirements of porous concrete, it can be recommended that water-to-cement ratio and cement-to-coarse aggregate ratio are 25% and 20%, respectively, under the aggregate particle distribution of 15~20mm. The failure mode of porous concrete blocks reinforced with GFRP bars was governed by shear cracks. As a result, very few flexural resistance of the GFRP was expected. However, the enhanced shear strength of porous concrete due to the dowel action of the GFRP bars increased the load capacity and toughness of the blocks. The porous concrete blocks reinforced with one GFRP bar at each compressive and tensile regions had 2.1 times higher load capacity than the companion non-reinforced block and exhibited a high ductile behavior with the ultimate toughness index ($I_{30}$) of 43.4.