• 제목/요약/키워드: 전기IT

검색결과 23,855건 처리시간 0.046초

화학기상증착 및 마그네트론 스퍼터링 방법으로 증착된 절연박막의 물성 분석 및 전기적 특성 (Characterization of microstructures and electrical properties of insulating thin films deposited by PECVD and RF magnetron sputtering)

  • 윤상한;이재엽;박창균;서수형;김용상;박진석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 D
    • /
    • pp.1707-1709
    • /
    • 1999
  • Insulating thin films for strain gauge application, such as $SiO_2$ single layers and $SiO_2/Si_3N_4$ multilayers, are deposited by using both PECVD and RF magnetron sputtering techniques. Micro-structural analysis and electrical characterization are carried out on those films. It has been observed that PECVD films have a smoother surface and a denser micro-structure than sputter films. It should be also found out that the electrical insulation property of $SiO_2$ film can be significantly improved by adding the $Si_3N_4$ layer.

  • PDF

미세가공 진동형 자이로스코프의 특성 감지 회로의 설계에 관한 연구 (Design of the Detection Circuitry for the Characteristics of Micromachined Vibrating Gyroscope)

  • 우영신;변광균;서일원;성만영
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제48권10호
    • /
    • pp.687-692
    • /
    • 1999
  • A new technique to measure low level capacitance variations of the gyroscope is proposed and verified by computer simulation. It is based on the new CV(capacitance-voltage) converter circuit biased by dc current source and the peak detector without low pass filter. The CV converter biased by dc current source provides good signal-to-noise ratio and this setup of the detection circuitry without low pass filter makes it possible to provide short settling time, that is, higher speed of measurement and wide operation range if only a few parameters are adjusted. The key parameters that affect the performance of the detection circuitry are illustrated and computer simulation results are presented. The demonstrated detection circuitry shows linear response from 10 fF to 130 fF at 10 kHz and shows good linearity.

  • PDF

차폐분리에 의한 전력케이블 및 접속함의 부분방전 위치 검출 (PD Localization by Metal Sheath Interruption Methods for Power Cable and Accessories)

  • 이창영;신두성;김충식;김동욱;박완기
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제49권3호
    • /
    • pp.196-201
    • /
    • 2000
  • It is very important not only to detect PD signal but also to locate PD source in power cable line including its accessories. In this paper, the PID localization technique using interruption of metal sheath of cable or accessory is described. By interruption of metal sheath, the polarity of PD pulse to be measured on each part can be compared. With this technique, the exact location of PD in the accessory which has some defects can be found. Although the 'Soft' interruption method, that is, cable sheath is divided by semi-conductive layer with the resistance of higher than 1 k$\Omega$, was used instead of 'Hard' interruption method, it is also possible to detect exact location of PD. This technique is considered to be very effective for detecting PD localization in the type test of cable and accessories.

  • PDF

유중 부분방전 펄스 특성을 이용한 TF 분석에 대한 고찰 (Considerations on the TF Anal,ysis using Partial Discharge Pulse Characteristics in Oil)

  • 김정태
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제54권11호
    • /
    • pp.508-514
    • /
    • 2005
  • In this paper, it was investigated the characteristics of PD(partial discharge) pulse shapes in oil and the possibility of TF(Time-Frequency) analysis for the discrimination of air corona in on-site PD measurement of oil transformers. For the purpose, single and multiple discharges combined with oil discharges and air corona were generated and measured by use of artificial models through the HFPD pulse detector and the oscilloscope. PD pulse shapes were different according to the type of defects, especially including air corona- pulses. Also, through the TF analysis, data clusters could be classified each other in the TF Map, even in the case of multiple discharges. Therefore, it is known that TF analysis could be aprlied for the improvement of on-site PD measurement in oil transformers.

미소전극어에이형 DNA칩을 이용한 유전자의 전기화학적 검출 (Electrochemical Detection of Genes Using Microeledtrode Array DNA Chip)

  • 최용성;박대희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 C
    • /
    • pp.2125-2127
    • /
    • 2004
  • In this paper, a DNA chip with a microelectrode array was fabricated using microfabrication technology. Several probe DNAs consisting of mercaptohexyl moiety at their 5 end were immobilized on the gold electrodes by DNA arrayer. Then target DNAs were hybridized and reacted with Hoechst 33258, which is a DNA minor groove binder and electrochemically active dye. Linear sweep voltammetry or cyclic voltammetry showed a difference between target DNA and control DNA in the anodic peak current values. It was derived from Hoechst 33258 concentrated at the electrode surface through association with formed hybrid. It suggested that this DNA chip could recognize the sequence specific genes.

  • PDF

바이너리제어를 이용한 동력설비용 브러시리스 직류전동기의 위치제어 (A Position Control of Brushless DC Motor for Power Installation with Binary Control)

  • 유완식;조규민;김영석
    • 한국조명전기설비학회지:조명전기설비
    • /
    • 제9권4호
    • /
    • pp.55-61
    • /
    • 1995
  • Variable structure control (VSC) can be used for the control of power plants required stability and robustness such as elevator control. It has no overshoot and is insensitive to parameter variations and disturbances in the sliding mode where the system structure is changed with the sliding surface in the center. But in the real system, VSC has a high frequency chattering which has a bad influence upon the control system proformances. In this paper, to alleviate the high frequency chattering, a binary controller (BC) with inertial type external loop is implemented by DSP and applied to position control of brushless DC motor. Binary controller has external loop to generate the continuous control input with the flexible variation of primary loop gain. Thus it has the property of chattering alleviation in addition to advantages of the conventional variable structure control.

  • PDF

수성(水性)펜침방전(針放電)의 전기화학적(電氣化學的) 특성(特性) (Electrochemical Characteristics of a Water-Pen Point Discharge in Atmosphere)

  • 이대희;김진규;문재덕
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 하계학술대회 논문집 C
    • /
    • pp.1378-1381
    • /
    • 1995
  • Some interesting electrochemical characteristics of waterpen point-to-plate airgaps for dc and ac powers have been investigated at room atmosphere in a metal chamber. It is found that the ac discharge on the Pt point generated much ozone, while the negative do discharge on the waterpen point generated the highest ozone. And, the ac discharges of the waterpen point and the Pt point produced a little $NO_x$. But the dc discharge of the Pt point and waterpen point did not generated $NO_x$ anyway. As a result, it could be said that the water on the pen point acts something to generate ozone and $NO_x$ in room atmosphere.

  • PDF

하이브리드커패시터용 활성탄전극의 리튬도핑에 따른 전기화학적 거동

  • 조민영;노광철;이재원;박선민;이동렬;한상진
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2009년도 추계학술대회 논문집
    • /
    • pp.266-266
    • /
    • 2009
  • For the development of hybrid supercapacitor, increasing energy density is one of the most crucial matters. Since the energy density is the function of capacitance and voltage, it is necessary to enhance energy density for increasing capacitance or voltage. For the high working voltage, it was to enforce Li ion free-doping to activated carbon. As a result, initial capacitance has increased by 11% than raw cell. But capacitance has decreased by Li ion re-solution to electrolyte for increase the number of cycle.

  • PDF

Q-V Lissajous 방법을 이용한 Xe형 평판형 형광램프의 전기광학 특성 평가 (Electrooptic Characteristics of Xe-type Flat Fluorescent Lamps Studied by a Q-V Lissajous Method)

  • 김영엽;유미연;고재현;유시홍;이성의
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2007년도 추계학술대회 논문집
    • /
    • pp.165-168
    • /
    • 2007
  • Electrooptic characteristics of Xe-type flat fluorescent lamps (FFL) have been investigated by using a Q-V Lissajous method. It was found that the luminance of the Mgo-coated FFL became more than doubled compared to normal FFLs operated at the same driving voltage, indicating the possibility of the efficacy improvement in the MgO-coated FFLs. Change in the driving condition, in particular, the duty ratio had effects on the electrooptic properties, and it was found that the duty ratio of 50% was the optimum condition from the viewpoints of the efficacy and the lamp voltage.

  • PDF

건축전기설비분야의 성능중심 건설기술기준 작성 지침 개발 (Performance based Construction Specifications and Design Criteria Development Plan of Electrical Installations)

  • 김세동;이광식;최은혁
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2007년도 추계학술대회 논문집
    • /
    • pp.209-212
    • /
    • 2007
  • It is increased electrical energy consumption with the development of intelligence society in buildings and thus an energy conservation through efficient use of electricity and reliability, safety, etc became more important. This research paper intensively investigated performance based construction specifications and design criteria of electrical installations in domestic and foreign country. It is necessary to analyze the key features based on performance and general trend about contractor guarantee, warranty method, performance design criteria from the investigated data. This paper shows a reasonable performance based construction specifications and design criteria of electrical installations.

  • PDF