• 제목/요약/키워드: 전기IT

검색결과 23,855건 처리시간 0.045초

플라즈마 디스플레이 판넬의 제작 및 특성 연구 (A Study on the Fabrication of Plasma Display Panel and It's Characteristics)

  • 김준식;최경철;신범재;황기웅
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1990년도 추계학술대회 논문집 학회본부
    • /
    • pp.157-160
    • /
    • 1990
  • A dot matrix type DC Plasma Display Panel was fabricated and it's characteristics was investigated. Paschen curve and I-V curve of various gas mixture was given. Optimal gas mixing ratio, pressure and operating point was determined. The priming effect was observed and discharge delay time was measured with varing applied voltage, priming current, priming distance, duty ratio.

  • PDF

상태 공간 외란관측기를 이용한 강인 제어기법 연구 (The study of Robust Control using a State-Space Disturbance Observer)

  • 조규남;정정주;이승희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 학술대회 논문집 정보 및 제어부문
    • /
    • pp.705-707
    • /
    • 2004
  • In this paper, we propose a robust control technique against parameter uncertainties as well as external disturbances. It is robust control scheme using discrete-time state space disturbance observer. It does not require disturbance modeling, plant inverse modeling and/or Q filter. In frequency domain, its performance is evaluated in terms of sensitivity and complementary sensitivity as well as gain and phase margin. Finally we discuss design criterion of state space disturbance observer considering its performance in frequency domain.

  • PDF

초전도 전류 발전기의 유도리액턴스 손실에 관항 연구 (A Study on the Analysis of the Inductive Reactance Losses of a Superconducting Current Generator)

  • Ko, Tae-Kuk
    • 대한전기학회논문지
    • /
    • 제39권12호
    • /
    • pp.1317-1320
    • /
    • 1990
  • The inductive reactance losses of a superconducting current generator built at Case Western Reserve University has been analyzed. The calculations of the field in the spot make it possible to estimate the spot inductance as well as the filament inductance on the foil. It is shown that magnetic energy lost in switching the current is mainly due to the amplitude of the fluctuation in voltage associated with the inductive reactance losses of a superconducting current generator.

  • PDF

건설전원용량에 따른 신설전원의 안정도특성 (The Stability Dependency of New Generator on the Existing System Capacity)

  • Nam, Sang-Cheon
    • 대한전기학회논문지
    • /
    • 제35권7호
    • /
    • pp.285-295
    • /
    • 1986
  • This study is to investigate the stability of expanded new generator plant depending on the capacity of existing system. We examined the transmitting power limit to the existing system as its capacity increase for the various system configuration with fixed location of plants and substations. The results show that the stability has decreasing tendency when the existing source capacity increase. Thus it can be concluded that new generator has little stability problem when it connected to small system, whereas large existing system capacity gives remarkable difficulty in adopting new generator.

  • PDF

HVDC 송전을 위한 새로운 집적변환 발전기 계통과 그 회전자 중심의 와전류 (A Novel Integrated Generator Converter System for HVDC and Eddy Current of it's Solid Rotor Core)

  • 이은웅;김일중;이민명
    • 대한전기학회논문지
    • /
    • 제37권7호
    • /
    • pp.434-441
    • /
    • 1988
  • This paper proposes a new invention of the integrated generator converter system for the HVDC transmission. And it analyses the general formula for eddy currents in the rotor iron using the double Fourier series in order to trace the smallest eddy current losses of the system which connects a new designed synchronous generator windings or conventional synchronous generator windings with the v Graetz bridges.

  • PDF

Interior Point Method를 이용한 최적조류계산 알고리듬 개발에 관한 연구 (A Study on Optimal Power Flow Using Interior Point Method)

  • 김발호
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제54권9호
    • /
    • pp.457-460
    • /
    • 2005
  • This paper proposes a new Interior Point Method algorithm to improve the computation speed and solution stability, which have been challenging problems for employing the nonlinear Optimal Power Flow. The proposed algorithm is different from the tradition Interior Point Methods in that it adopts the Predictor-Corrector Method. It also accommodates the five minute dispatch, which is highly recommenced in modern electricity market. Finally, the efficiency and applicability of the proposed algorithm is demonstrated with a case study.

새로운 열차제어시스템 도입시에 신호시스템 절체 방안에 관한 고찰 (A consideration of signalling system switchover at installation of new train control system)

  • 조봉관
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 추계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.283-285
    • /
    • 2003
  • Metro is taking an important part as a public transportation of densely populated area. but according to request of increasing transportation demand and improving service for passengers, minimizing headway, functional improvement of safety facility, improving riding comfort are needed. Also, it is the time for Seoul metro's signalling system to be improved into a new one as it has been opened to traffic for over 20 years and its signalling system is becoming superannuated. this paper reviewed the considerations at improving a signalling system and its solution.

  • PDF

2차 격자기전력에 의한 유도전동기의 특성 (Characteristics of induction motor by changing the second exciting E.M.F.)

  • 황영문
    • 전기의세계
    • /
    • 제15권2호
    • /
    • pp.1-7
    • /
    • 1966
  • It is well known that the speed of induction motor can be controlled in wide range by changing the second exciting e.m.f. of rotor circuit, but that is well not practised because of its complicated system. In order to simplify such a system, the Kramer system of which silicon rectifier substitutes for synchronous converter has analyzed in this paper. The result of this investigation show that in this system, only the equivlent synchronous speed it changed by second exciting e.m.f., but the mechanical output power, torque and power factor is not changed, and that this system is able to compensate the regulated speed on account of the load changed.

  • PDF

Gate turn on thyristor 역변환장치의 변환전력한계치에 대하여 (The analysis of the conversive limitation of electric energy for the gate turn on thyristor inverter)

  • 천희영
    • 전기의세계
    • /
    • 제17권2호
    • /
    • pp.6-10
    • /
    • 1968
  • The conversive limitation of electric energy for the thyristor inverter is analysed under the boundary conditions which the term of a negative inverse voltage is longer than that of the turn off time of the thyristor under commutation. It is clear that the maximum electric energy conversion is affected by the turn off time of the thyristor, the reactance of a commutation reactor, the capacity of a commutation condenser and the voltage of Direct current source. It is useful for design the thyrister invertor and the motor speed control to apply the above conclusion.

  • PDF

배전용 변압기의 합리적인 사양과 그 설계법 (The optimum specifications and design of distributive transformers)

  • 이승원
    • 전기의세계
    • /
    • 제14권4호
    • /
    • pp.8-17
    • /
    • 1965
  • Firstly, this study has analyzed the following factors affecting the optimum specifications and design of distributive transformers: 1. Facilities installation cost per unit power output. 2. Facilities operating & maintenance cost per unit power output. 3. Production cost per unit power output. 4. Load factor. 5. Loss factor. Secondly, it has clarified the relations between the following factors and the specifications and design of distributive transformers; 1. No-load loss., 2. Load loss., 3. Voltage regulation., 4. Exciting current. Finally, it has determined the method of the most economic design for the transformers using the above factors and relations, and, for optimum the illustrative purpose, suggested their optimum specifications, way of evaluation, and merits by means of typical example.

  • PDF