• Title/Summary/Keyword: 전기IT

Search Result 23,898, Processing Time 0.051 seconds

Electrochemical properties of Pt electrodes fabricated by other methode as counter electrode of DSC (염료감응형 태양전지의 상대전극용 Pt의 제조방법에 따른 전기화학적 특성)

  • Kim, Hyun-Ju;Lee, Dong-Yun;Koo, Bo-Kun;Lee, Won-Jae;Song, Jae-Sung
    • Proceedings of the KIEE Conference
    • /
    • 2005.07c
    • /
    • pp.2016-2018
    • /
    • 2005
  • Dye-sensitized solar cell (DSC) consist of oxidation semiconduction electrode, electrolyte and counter electrode. Among these, Pt as counter electrode of DSC plays a role in helping redox reaction of iodine ions in electrolyte, also, transferring electrons into electrolyte. In this case, it is expected that characteristics of Pt electrodes strongly depend on fabrication process and its surface condition. In this study, electrochemical behavior of the electro-plated Pt electrode was compared with that of the sputtered Pt electrode, using cyclic-voltammetry and impedance spectroscopy (PARSTATE 2273, by AMETEK). Surface morphology of Pt electrode was investigated by AFM (XE-100, by PSIA). As a result, it was considered that electrochemical properties of sputtered Pt electrode is superior to that of electro-plated Pt electrode.

  • PDF

Electromagnetic Characteristics of Ceramics Superconductor (초전도체의 전기자기적 특성)

  • Lee, Sang-Heon;Lee, Sung-gap;Kim, Young-Kuk;Yoo, Jae-Mu;Lee, Young-Hie
    • Proceedings of the KIEE Conference
    • /
    • 2004.11a
    • /
    • pp.203-204
    • /
    • 2004
  • Suspension effect has been studied by using superconductor of BiPbSrCaCuO ceramics containing $Ag_2O$. It has been cleared that $Ag_2O$ acts as pinning center which plays an important role to the suspension effect. Magnetic repulsive force which affects a superconductor located in magnetic flux from toroidal magnet has been investigated. It has been concluded that the suspension effect arises from the interaction between the pinning effect and the diamagnetic effect.

  • PDF

The Electrical Characteristics of $(Ba_{0.5}\;Ca_{0.5})TiO_{3}$ Humidity-Sensitive Devices ($(Ba_{0.5}\;Ca_{0.5})TiO_{3}$ 감습소자의 전기적 특성)

  • Yuk, Jae-Ho;Lee, Duck-Chool
    • Journal of Sensor Science and Technology
    • /
    • v.5 no.3
    • /
    • pp.33-40
    • /
    • 1996
  • $(Ba_{0.5}\;Ca_{0.5})TiO_{3}$ humidity-sensitive devices were fabricated by a solid reaction method, and their electrical properties were investigated. The specimens exhibited good humidity sensitivity, in which the impedance changes linearly. It is shown that electrical conduction with moisture adsorption is dominated by the ions through characteristics of charging and discharing current, and electrical conductivity increases as rasing the temperature and relative humidity. It is realized that relative permittivity increases and activation energy decreases with increasing relative humidity.

  • PDF

A Study on Mechanical, Electrical Properties of Epoxy/MICA Composites with MICA Filled Contents (Epoxy/MICA 복합체의 MICA 충진함량 변화에 대한 기계적, 전기적 특성연구)

  • Park, Jae-Jun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.2
    • /
    • pp.219-227
    • /
    • 2013
  • This paper reported a study on the thermal, mechanical and electrical insulation properties of epoxy/mica composites. To investigate the effect of mica content, glass transition temperature, mechanical properties such as tensile and flexural strength, and insulation breakdown properties for epoxy composites with various contents of mica. The effect of insulation thickness on insulation breakdown property was also studied. It was observed that tensile and flexural strength decreased with increasing mica content, while elastic modulus increased as the mica content increased. AC insulation breakdown strength for all epoxy/mica composites was higher than that of neat epoxy and that of the system with 20 wt% mica was 14.4% improved. As was expected, insulation breakdown strength at $30^{\circ}C$ was far higher than that at $130^{\circ}C$, and it was also found that insulation breakdown strength was inversely proportion to insulation thickness.

Single-Chip Microprocessor Based Instantaneous Voltage Control of Inverter for UPS (Single-Chip 마이크로프로세서를 이용한 UPS용 인버터의 순시전압제어)

  • 최재호;박세현;민완기;김재식
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.6 no.6
    • /
    • pp.49-57
    • /
    • 1992
  • This paper proposes a Intel 8097 single-chip microprocessor based instantaneous voltage control scheme of inverter for UPS(Uninterruptible Power Supply). There microprocessors are used to control the output voltage and frequency of the inverter, the synchronization with by-pass, and the switching of the static switch. And the status and operating conditions of UPS systems is monitored by micro processor. The inverter output voltage is controlled instantaneously with a double regulation loop so that it has very good dynamic response for the varying loads or nonlinear loads as a rectifier. And also, the software and hardware of control system is described. From simulation and experimental results, it is shown that the proposed scheme has very good performance.

  • PDF

On-site Survey of the Street Lighting Facilities (가로등의 전기설비 현장실태조사)

  • Kim, Han-Sang;Bae, Suk-Myong;Kim, Chong-Min
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2006.05a
    • /
    • pp.426-431
    • /
    • 2006
  • The case where a drain cannot flow backwards, a sewer institution can be unmanageable in this, and a mad is under water momentarily by local heavy nin by the climate phenomenon in spite of not being a lowlands belt has occurred well more than recently. By the flooded mea since it is in the state which has some human bodies at hand, when a short circuit occurs in street lighting pole which is the electric institution thing of a road, the danger of an electric shock accident becomes higher. In this paper, it was going to show improvement plan for grasping the brittle factor of street lighting pole electricity facilities through the on-site survey of street lighting pole electricity facilities, and improving this.

  • PDF

Investgating Effects of Peak Load of Korean Power System from Electric Heating appliances except House (비주택용 전기난방기구가 우리나라 첨두부하에 미치는 영향 검토)

  • Kim, Yong-Ha;Lee, Kwang-Sung;Heo, Dong-Ryeul;Lee, Sung-Jun;Lee, Yong-Suk;Woo, Sung-Min;Son, Seung-Kee
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2006.05a
    • /
    • pp.442-447
    • /
    • 2006
  • This paper investigates the shadow amount of edifice and according to time zone used by its Electric heating appliances, it is analyzed that Electric Heating Power Load affects Heal power load variation curve. Also, in case that the far infrared ray heating system, which are used as new electric heating system, occupies some of the existing Electric heating appliances, it is analyzed that the Electric heating power load affects the Peak load power in Korea.

  • PDF

Arcing horn design specification and electrical characteristics special quality estimation of distribution line (배전선로의 내뢰흔 설계사양 및 전기적 특성 평가)

  • Kim, Seok-Sou;Choi, Ik-Sun;Park, Tae-Gon
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.472-473
    • /
    • 2007
  • This study evaluated electrical characteristics of the manufactured arcing horn whose rated voltage and nominal discharge current were 18kV and 2.5kA, respectively. In this study, residual voltage and lightning impulse flashover voltage were examined. The arcing horn showed excellent electrical characteristics that residual voltage and lightning impulse flashover voltage were 55kV below and 121kV at 115mm, respectively. Therefore the manufactured arcing Horn is considered that it would show good performance for protecting electrical wires and line post insulators from lightning impulse, if it were applied to real fields.

  • PDF

A Study on RCM Approach to Catenary System of Electric Railway (전기철도 가공전차선로의 신뢰성 기반 유지보수(RCM)에 관한 연구)

  • Youn, Eung-Kyu;Choi, Kyu-Hyoung
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.8
    • /
    • pp.1457-1465
    • /
    • 2016
  • A RCM approach to maintenance of the catenary system of electric railway is proposed. The proposed RCM approach provides a maintenance-oriented FMECA procedure to derive critical failure modes by analyzing failure effects and a RCM decision logic tree to suggest optimal maintenance works for the derived failure modes. By applying the proposed RCM procedures to the catenary system of high speed railway, it is suggested that strand breaks of dropper and voltage equalizing wire, and trolly wire wear-out are the critical failure modes for whom maintenance works based on condition monitoring should be applied instead of conventional time-based preventive maintenance. It is also proposed by reliability analysis that replacement time of dropper can be reduced from 18 years to 10 years. These results show that the proposed RCM approach can optimize the maintenance procedures of catenary system.

Dynamic Characteristic Analysis of Electro-Mechanical Coupled System Considering a Temperature (온도를 고려한 전기-기계 결합 시스템의 운동 특성 해석)

  • Choi, Yoon-Seok;Kwak, Dae-Yong;Sung, Tan-Il;Kim, Young-Sun;Park, Il-Han
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.870-871
    • /
    • 2007
  • As the system with current is heat generation system, it has to be analyzed to consider effect in virtue of temperature. Hence this paper examined the solution of the coupled thermalelectro-mechanical problem. Mechanical modeling, force computation, electromagnetic field solution, and heat transfer modeling are addressed. It accomplished electro-mechanical coupled system analysis considering a temperature, the analysis method is by using extracted circuit parameters with resistivity by heat transfer analysis and inductance by electromagnetic analysis.

  • PDF