전하펌프 역률개선 회로를 적용한 양방향성 AC-DC Converter 설계 (Design of a Bidirectional AC-DC Converter using Charge Pump Power Factor Correction Circuit)

  • 고석철;임성훈;한병성
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.227-230
    • /
    • 2001
  • This paper deals with a bidirectional ac-dc converter used in ups system application. We propose a Voltage-Source-Charge-Pump-Power-Factor-Correction(VS-CPPFC) ac-dc converters. First of all, we propose a charge pump power-factor-correction converter. Secondly, we derive and analyse a unity power factor condition. The proposed topology is based on a half-bridge for the primary and a current-fed push pull for the secondary side of a high frequency isolation transformer. The advantage of bidirectional flow of power achieved by using the same power components is that the circuit is simple and efficient. And the galvanically isolated topology is specially attractive in battery charge/discharge circuits in ups system. We design equivalent model for the steady-state circuit and analyse operation waveforms for each mode. We show that the proposed model can be applied to ups system by simulation processes.

  • PDF

의료용 펌프의 리니어 모터 설계 및 해석 (Design and Analysis of Linear Motor for Medical Appliance Pump)

  • 김동수;이원희;박재범
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 D
    • /
    • pp.2683-2686
    • /
    • 2002
  • In this paper, it has been investigated that the design and simulation of linear motor for medical appliances. Vacuum pump consists of unified plunger and piston part, coils, inlet valve and outlet valve. Operating principal of vacuum pump show that air is to flow to go inside through the inlet valve, when the magnetic force (16N) is exerted, whereas, air is to flow to go outside through outlet valve, when spring force (14.8N) is exerted. The results of simulation, it was turned out that magnetic force was loaded with 16 Newton, displacement of actuator was about 8mm.

  • PDF

급수펌프 구동용 증기터빈 제어기의 신뢰성 검증을 위한 시뮬레이터 구현 (A realization of simulator for reliability verification on turbine controller for boiler feed Pump)

  • 최인규;정우중
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 D
    • /
    • pp.2307-2309
    • /
    • 2002
  • A simulator had been developed and will be used for reliability verification on turbine control programs for boiler feed pump in power plant prior to its actual operation in field. A mathematical model on thermal dynamics pertaining to prime mover steam turbine and pump was realized and included in this simulator. Also, many design and operating data acquired from fields were utilized in order to decide mechanical and thermal dynamic characteristics such as friction loss windage loss and inertia. A user can decide closing or opening velocity of steam stop valves and steam regulation valves. This simulator is able to generate steam pressure, turbine speed, pump power.

  • PDF

직류전동기 구동 원심펌프-파이프 계통의 고장검출진단시스템: 등가관계 접근법 (Fault Detection and Isolation System for DC motor driven Centrifugal Pump-Pipe Systems: Parity Relation Approach)

  • 박태건;류지수;이기상
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 B
    • /
    • pp.819-821
    • /
    • 1998
  • This paper deals with a method or a residual generation for fault isolation in a centrifugal pump with a water circulation system, driven by a speed controlled dc motor. It is based on parity relations derived from the moving-average model of the system and is used to identify sensor faults and two possible brush and impeller faults, where the former is dealt with additive faults, while the latter characterized as discrepancies between the nominal and actual plant parameters of the system is modelled by multiplicative faults. We will represent the propagation of this uncertainty to the model matrices by the approximate handling of partial derivatives of polynomials. With multiplicative faults, the transformation matrix implemented in the residual generator are calculated on-line. The simulation studies demonstrate that small changes of the system can be detected and diagnosed by using the method.

  • PDF

등가회로 해석법에 의한 환단면형 유도전자펌프의 설계 (A design of the annular induction electromagnetic pump by equivalent circuit modelling)

  • 김희령;홍상희;황종선;민병태;남호윤;조만
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1994년도 하계학술대회 논문집 C
    • /
    • pp.1431-1434
    • /
    • 1994
  • The annular induction electromagnetic pump with maximum flowrate of $60{\ell}/min$ for the sodium coolant system of liquid metal fast breeder reacters has been designed using the equivalent circuit method. The final optimum values of geometrical and electromagnetic parameters were obtained for an annular induction pump from the relation of the electrical variables giving the developing force to the fluid and the pressure drops between both sides of the pump. The physical properties of the core, coil condoctor materials in the high temperature and pump cooling systems under operation have been taken into account in the design of the pump. The structural material were also selected considering the reaction with sodium and the magnetic field distortion.

  • PDF

유압펌프용 SRM 구동 시스템의 특성해석 (Characteristics Analysis of SRM Drive System for Hydraulic Pump)

  • 이주현;김봉철;김태형;안진우
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.83-86
    • /
    • 2005
  • This paper proposed a hydraulic pump system which uses a variable SR drive and constant capacity pump. The base and maximum speed, torque are determined from displacement capacity of the pump and maximum pressure. The drive system is set to have a minimum power consumption having hydraulic preset pressure, which is operated within a maximum capacity and maximum preset pressure. This is achieved by controlling motor speed and power with feedback signal of pressure of the hydraulic pump. A 2.2kw, 12/8-pole SR motor and DSP based digital controller are designed and prototype drive system is manufactured. The proposed variable speed SR drive system is simulated and tested with experimental set-up. The test results show that the system has some good features such as high efficiency and high response characteristics.

  • PDF

Magnetic Fluid Linear Pump 관내의 자성유체 형상에 관한 연구 (Research of forming shapes of Magnetic Fluid in tube of Magnetic Fluid Linear Pump)

  • 성일권;서강;박관수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.90-92
    • /
    • 2005
  • Magnetic Fluid Linear Pump(MFLP)는 자성유체의 자기적 성질과 유체의 성질을 이용하여 일반적인 펌프의 기어 대신 자성유체를 이용하여 기계적 진동이나 소음을 최소화한 시스템이다. MFLP는 구조가 간단하고 동작전류에 의해 쉽게 조절할 수 있다. MFLP의 동작전류에 의해 발생한 자기장의 정도에 따라 유연하면서 펌핑력이 높은 동작이 가능하다. 따라서 MFLP를 운전하는데 있어 동작전류의 패턴과 크기, 중첩정도에 따른 펌핑력이 변하게 되며, 이에 따른 자기장과 관내의 자성유체의 형상을 해석하여 유연하고 펌핑력이 높은 MFLP의 운전방식을 개발하고자 하였다.

  • PDF

LED 구동 IC를 위한 레벨 시프터 방식의 전하펌프 회로 설계 (Design of a Charge Pump Circuit Using Level Shifter for LED Driver IC)

  • 박원경;박용수;송한정
    • 한국전기전자재료학회논문지
    • /
    • 제26권1호
    • /
    • pp.13-17
    • /
    • 2013
  • In this paper, we designed a charge pump circuit using level shifter for LED driver IC. The designed circuit makes the 15 V output voltage from the 5 V input in condition of 50 kHz switching frequency. The prototype chip which include the proposed charge pump circuit and its several internal sub-blocks such as oscillator, level shifter was fabricated using a 0.35 um 20 V BCD process technology. The size of the fabricated prototype chip is 2,350 um ${\times}$ 2,350 um. We examined performances of the fabricated chip and compared its measured results with SPICE simulation data.

위상 고정 루프의 기준 스퍼를 감소시키기 위한 이중 보상 방식 전하 펌프 (A Dual-compensated Charge Pump for Reducing the Reference Spurs of a Phase Locked Loop)

  • 이동건;이정광;정항근
    • 전기학회논문지
    • /
    • 제59권2호
    • /
    • pp.465-470
    • /
    • 2010
  • The charge pump in a phase-locked loop is a key block in determining reference spurs of the VCO output signal. To reduce reference spurs, the current mismatch in the charge pump must be minimized. This paper presents a dual compensation method to reduce the current mismatch. The proposed charge pump and PLL were realized in a $0.18{\mu}m$ CMOS process. Measured current matching characteristics were achieved with less than 1.4% difference and with the current variation of 3.8% in the pump current over the charge pump output voltage range of 0.35-1.35V at 1.8V. The reference spur of the PLL based on the proposed charge pump was measured to be -71dBc.

자동차 연료 절감을 위한 연료펌프 다단 제어기 설계 (Design of Multi Step Fuel Pump Controller for Vehicle's Fuel Retrenchment)

  • 양재원;양승현;이석원
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 심포지엄 논문집 정보 및 제어부문
    • /
    • pp.307-308
    • /
    • 2007
  • At present, there are unnecessary electrical consumes and a lot of fuel-losses by the vaporized gas due to the rising of fuel temperature because the fuel pump of the fuel supply system rotates regularly regardless to the driving condition. In this paper, we designed the multi-step controller for controlling fuel pump to supply fuel according to RPM of each moment by measuring the real time RPM of the engine at ECU of the vehicle. Also, it can judge the existence or nonexistence of disorder by measuring the pressure of the fuel supply line, in case of abnormal state, it can supply the fuel intelligently by changing the mode to self-compensation mode.