• Title/Summary/Keyword: 전기절연파괴

Search Result 590, Processing Time 0.029 seconds

Pinhole Phenomena in the External Electrode Fluorescent Lamps (외부전극 헝광램프의 핀홀 현상)

  • Gill, Doh-H.;Kim, Sang-B.;Song, Hyuk-S.;Yu, Dong-G.;Lee, Sang-H.;Pak, Min-Sun;Kang, June-Gill;Cho, Guang-Sup;Cho, Mee-R.;Hwang, Myung-G.;Kim, Young-Y.
    • Journal of the Korean Vacuum Society
    • /
    • v.15 no.3
    • /
    • pp.266-272
    • /
    • 2006
  • Application of power higher than the optimum operation value to an external electrode fluorescent lamps(EEFL) leads to the formation of small holes, called pinholes, which subsequently leads to lamp failure. The pinholes come from the insulating breakdown of the capacitor which is the dielectric layer between an external electrode and glass tube. The power of insulation breakdown is proportional to the electric power applied to the lamp. When a lamp current is low in the glass tube of dielectric constant K, the dielectric field strength of pinholes is about 3K kV/mm. The field strength of insulation breakdown decreases as the lamp current increases.

합성수지 절연재료의 Treeing파괴에 대한 소고

  • 곽영순
    • 전기의세계
    • /
    • v.25 no.6
    • /
    • pp.36-39
    • /
    • 1976
  • 폴리에틸렌 절연 전력케이블, 특히 가교폴리에틸절연 케이블이 고분자 재료분야의 발달에 수반하여 급속히 실용화되어 전압의 계급도 11-23KV급으로 부터 66KV급 이상으로의 개발이 요망되고 있는 실정이다. 미국등 선진국에 있어서는 이미 이에 대한 충분한 연구가 진행되어 시험법이 제정되어 상위전압계급의 케이블 제작을 위한 연구가 활발히 진행되고 있는 상태이다. 따라서 앞으로 우리나라 고전압 분야에 있어서도 상기 분야의 개발을 위한 기초작업으로서 케이블의 사용조건, 케이블의 성능, 케이블의 열화성능, 시험기술등에 대한 조사, 연구, 분석이 필요함은 물론, 관계연구자들의 공동실험등 적극적인 참요가 요망되는 바이다. 본문에 있어서는 현재까지 진행되어 온 외국에 있어서의 합성수지절연체에 대한 여러가지 실험결과에서 판단한 앞으로의 연구과제 및 조사보고를 집약하여 간단히 소개코자 한다.

  • PDF

Failure Analysis for 25.8kV $SF_6$ Gas Switchgears (25.8kV $SF_6$ 가스개폐기의 고장분석)

  • Kwon, Tae-Ho;Kim, Dong-Myeong
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.2069-2070
    • /
    • 2008
  • 본 논문은 최근에 25.8kV $SF_6$ 가스절연부하개폐기 (이하 가스개폐기)에서 발생한 고장을 전력연구원에서 분석하여 고장 원인별 현황을 나타내었으며, 주요 고장으로 분류되는 절연 불량, 기계적 손상, 외부 손상 등이 발생하는 원인을 분석하였다. 장기신뢰성 확보를 위해서 가스개폐기의 취약점인 $SF_6$ 가스 순도에 따른 절연파괴 특성 및 금속 파티클의 거동특성에 대해 분석하였다.

  • PDF

The Relation between Treeing Breakdown Prediction and Acoustic Emission in Low Density Polyethylene (저밀도 폴리에틸렌의 트리 파괴 예지와 음향방출과의 관계)

  • 백관현;심종탁;김재환
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.8 no.2
    • /
    • pp.77-84
    • /
    • 1994
  • This paper is measured partial discharge of low density polyethylene by using acoustic emission measuring method when the electrical tree grow its length in LDPE. Acoustic emission's pulses and its amplitudes of partial discharge are measured by acoustic emission measuring devices. Theorem of skewness are used for breakdown prediction of LDPE. So, it is found that the breakdown of LDPE could be predicted by its skewness's value. There are two kind of specimen of no void and specimen of artificial void, this one's electrical tree grows very faster than that one's.

  • PDF

Relation between Dielectric Diagnosis and ACBD Strength in URD Cables (배전케이블 진단결과와 교류절연파괴강도의 상관성)

  • 한재홍;김주용;김동명;이병성;정년호
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.11a
    • /
    • pp.484-487
    • /
    • 2000
  • This study is for assessing a reliability of diagnostic device through comparing diagnostic results to ACDB strength. The dielectric diagnosis using IRC (isothermal relaxation current) measurement was carried on service-aged cables. From this study, there was little correlation between dielectric diagnosis and ACBD strength in long distance cables. But the correlation between them showed in short distance below 200 m. Therefore, it is desirable to diagnose the URD cables in short distance.

  • PDF

765KV 송전선 유도장해 검토

  • 한국전력기술인협회
    • Electric Engineers Magazine
    • /
    • v.194 no.10
    • /
    • pp.27-31
    • /
    • 1998
  • 송배전선로 또는 전기철도 등의 전압에 의한 정전유도작용이나 전류에 의한 전자유도작용으로 인근 통신시설에 미치는 영향이 지나쳐 통신시설의 절연파괴나 운용방해를 유발하고 인체에 직, 간접으로 위험을 초래하는 것을 유도장해라 한다.

  • PDF

Evaluation of Electrical Degradation in Epoxy Composites by DC Dielectric Breakdown Properties (DC 절연파괴 특성을 이용한 Epoxy 복합체의 전기적 열화 평가)

  • 임중관;박용필
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2002.11a
    • /
    • pp.779-783
    • /
    • 2002
  • The dielectric breakdown of epoxy composites used for transformers was experimented and then its data were simulated by Weibull distribution probability. As a result, first of all, speaking of dielectric breakdown properties, the more hardener increased the stronger breakdown strength at low temperature because of cross-linked density by the virtue of ester radical. And the breakdown strength of specimens with filler was lower than it of non-filler specimens because it is believed that the adding filler forms interface and charge is accumulated in it, therefore the molecular motility is raised, the electric field is concentrated, and the acceleration of electron and the growth of electron avalanche are early accomplished. In the case of filled specimens with treating silane, the breakdown strength become much higher since this suggests that silane coupling agent improves interfacial combination and relaxs electric field concentration. Finally, from the analysis of weibull distribution, it was confirmed that as the allowed breakdown probability was given by 0.1%, the applied field value needed to be under 21.5MVcm.

  • PDF

The discharge Characteristics and the Bubble Motion in Liquid $SF_6$ (액체 $SF_6$중 기포거동과 절연파괴특성에 관한 연구)

  • Choi, Eun-Hyuck;Park, Kwang-Seo;Choi, Sang-Tae;Kim, Lee-Kook;Yoon, Bung-Han;Lee, Kwang-Sik
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2006.05a
    • /
    • pp.65-68
    • /
    • 2006
  • 현재 전력설비에 사용되고 있는 $SF_6$ 가스는 절연 및 소호성능이 우수하고 회복특성이 뛰어나기 때문에 각종 전력기기의 절연매체로서 널리 사용되고 있다. 하지만 산업사회의 발달로 인하여 도시의 공간 활용의 효율성 측면에서 전력기기들의 소형화, 지중화 및 고 신뢰화가 시도되고 있으며, 또한 온실가스에 대한 규제로서 '도쿄 의정서'가 정식 발효됨에 따라 환경문제로 인하여 전력설비의 $SF_6$ 가스의 유출 최소화, 대체 절연물질 개발 등의 친환경 재료의 개발이 새롭게 대두되고 있다. 따라서, 본 연구에서는 $SF_6$를 액화시켜 기존의 $SF_6$ 가스와 액체 $SF_6(LSF_6)$의 절연파괴특성을 측정/분석하여 $SF_6$의 대체물질로 $LSF_6$의 가능성을 검토하고, 혹한 지역에서 운용되고 있는 $SF_6$ 이용 전력설비의 온도저하에 따른 문제점을 구명하였다.

  • PDF

Study of Spacer for HTS Transformer (고온 초전도 변압기용 spacer 연구)

  • Kim, Sang-Hyun;Back, Seong-Myeong;Kim, Yeong-Seok;Han, Cheol-Su;Joung, Soon-Yong;Joung, Jong-Man
    • Proceedings of the KIEE Conference
    • /
    • 2001.11a
    • /
    • pp.238-240
    • /
    • 2001
  • 초전도 응용 기기의 실용화를 위해서는 극저온 냉매의 절연기술이 확립되어야 한다. 특히, 취급이 용이하고 경제성이 높은 액체 질소를 냉매로 사용하는 고온 초전도 응용 기기 개발이 활발히 이루어지고 있어 여러 고온초전도 응용 기기 중 고온 초전도 변압기의 pancake-coil 형 권선에서의 spacer에 대한 절연 특성을 연구하였다. 이때 spacer는 pancake-coil의 턴간 절연내력을 유지하여야 하며, 또한 냉매 유동 통로를 확보하여야 한다. 하지만 실용상에 있어서는 절연물의 계면을 따라서 진전하는 연면 방전에 의한 절연내력이 관통절연 파괴전압에 비해 낮아 절연 설계 시 유의해야 한다. 따라서 pancake-coil형 고온초전도 변압기 권선을 위한 spacer에 대한 연면 방전 특성을 연구하였다.

  • PDF

열사이클 열화에 따른 광유와 식물유의 절연파괴전압 분석

  • Heo, Chang-Su;An, Jeong-Sik;Sim, Myeong-Seop;Lee, Byeong-Taek;Choe, Sun-Ho;Jeong, Jung-Il;Kim, Nam-Ryeol
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2010.03b
    • /
    • pp.36-36
    • /
    • 2010
  • 송전 및 배전계통에 운영되고 있는 유입식 변압기는, 생분해성이 좋아 보다 더 친환경적인 식물성 절연유로 대체되어 가고 있으며, 미국등지에서는 이미 10여년 전부터 식물성 절연유를 사용한 변압기를 배전 및 송전 계통에 사용하고 있다. 본 연구에서는 기존의 광유계 절연유를 대체하는 식물성 절연유를 사용한 배전급 변압기 및 기존의 광유계 절연유를 사용하는 동일한 용량의 배전급 변압기($1_{\phi}2010KVA$ 13200-230V)를 제작하여 열사이를 형태의 복합 열화를 시켜, 식물유 및 광유를 채취 분석하고 그 열화 기구를 연구하였다.

  • PDF