• Title/Summary/Keyword: 전기저항측정

Search Result 1,479, Processing Time 0.03 seconds

Strains of abutment and bones on implant overdentures (임플란트 피개의치에서 지대주와 골의 변형률에 관한 연구)

  • Kim, Myung-Seok;Heo, Seong-Joo;Koak, Jai-Young;Kim, Sung-Kyun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.2
    • /
    • pp.222-231
    • /
    • 2009
  • Statements of the problem: Over the past decades, conventional complete dentures were used for various patients although they have incomplete function. Overdentures using dental implants could help the improvement of denture function. Purpose: The purpose of this study was to compare the strains of abutment and bone on implant overdenture between splinted and unsplinted type of prosthesis. Additionally, the strain values of parallel placed implant model and unparallel placed implant model were compared. Material and methods: Two acrylic resin model were prepared and two implants were placed at the canine positions in each model. In the first model, two implant were placed parallel. In the second model, two implants were placed with 10 degree labiolingual divergence. Two types of abutment were connected to the fixtures alternatively. One was splint type of Hader bar, the other was unsplint type of ball abutment. Overdentures were fabricated with corresponding attachment systems and seated on abutments. Strains of abutments and labial bone simulants were measured with electric resistance strain gauges when static load from 100 N to 200 N were applied to overdentures. Results: 1. Splinted type of overdentures using bar and clip showed higher absolute strain values. But the strain was compressive and the load was shared by two implants(P<.05). 2. Unsplinted type overdentures using ball and O-ring showed low absolute strain values(P<.05). 3. Labially inclined implant showed higher tensile strain values in unsplinted type of prosthesis than in splinted type of prosthesis. Lingually inclined implant showed rather low strain values under load(P<.05). 4. Non parallel implant model showed higher absolute strain values than parallel placed implant model comprehensively(P<.05).

Analysis of Groundwater Flow Characterization in Fractured Aquifer System (파쇄대 응회암 대수층의 지하수 유동 특성화 기법)

  • Kim Yong-Je;Kim Tae-Hee;Kim Kue-Young;Hwang Se-Ho;Chae Byung-Gon
    • Journal of Soil and Groundwater Environment
    • /
    • v.10 no.4
    • /
    • pp.33-44
    • /
    • 2005
  • On the basis of a stepwise and careful integration of various field and laboratory methods the analysis of groundwater flow characterization was performed with five boreholes (BH-1, -2, -3, -4, -5) on a pilot site of Natural Forest Park in Guemsan-gun, Chungcheongbook-do, Korea. The regional lineaments of NW-SE are primarily developed on the area, which results in the development of many fractures of NW-SE direction around boreholes made in the test site for the study. A series of surface geological survey, core logging, geophysical logging, tomography, tracer tests, and heat-pulse flowmeter logging were carried out to determine fracture characteristics and fracture connectivity between the boreholes. In the result of fracture connectivity analysis BH-1 the injection well has a poor connectivity with BH-2 and BH-3, whereas a good with BH-4 and BH-5. In order to analyse the hydraulic connectivity between BH-1 and BH-5, in particular, a conspicuous groundwater outflux in the depth of 12 m and influx in the depth of 65 m and 70 m, but partly in/outflux occurred in other depths in BH-5 were observed as pumping from BH-1. On the other hand, when pumping from BH-5 the strong outflux in the depths of 17 m and 70 m was occurred. The spatial connectivity between the boreholes was examined in the depth of 15 m, 67 m, and 71 m in BH-1 as well as in the depth of 15 m, 17 m, 22 m, 72 m, and 83 m in BH-5.

Assessment of Growth Conditions and Maintenance of Law-Protected Trees in Je-cheon City (제천시 보호수의 생육환경 및 관리현황 평가)

  • Yoon, Young-Han;Ju, Jin-Hee
    • Journal of the Korean Institute of Traditional Landscape Architecture
    • /
    • v.28 no.2
    • /
    • pp.67-74
    • /
    • 2010
  • Law-protected trees are our precious asset as natural resources with history and tradition and natural heritage which should be protected and maintained well to bequeath next generation. Law-protected trees have not only thremmatologic and genetic meaning but also environmental and emotional meaning for their value to be high. This study investigated location, vitality, wrapping condition of root area and status of maintenance of the trees to figure out their growth environment and status of maintenance in a small-middle city through survey on those of law-protected trees in Je-cheon. There showed 300 more year old trees in Je-cheon mostly and the number of trees located in flat fields was the highest. For location type, village, hill and road types were presented in the order and for degree of development, land for building was found most frequently. The average electric resistance of the formative layer was measured to be $8.4k{\Omega}$ and four trees showed bark separation. Most law-protected trees underwent tree surgery, and complete bareness of root area was observed in a tree. The root area of two trees was covered with concrete. pH of soil was recorded to be 5.0~8.4 with its average of 7.1 and electric conductivity(EC) was less than 0.5 dS/m. For status of maintenance rearing facilities were placed for 16 trees out of totally 48 ones and stone fence was done for three ones. Tree surgery was conducted for 33 trees to prevent and to treat decomposed parts of holes. Direction boards were installed for 23 trees. Based on these results, measures to manage systematically law-protected trees in Jecheon could be suggested as follows. First, a sufficient space for growth of low part of trees should be secured. Second, a voluntary management should be induced by advertising them to residents in a community. Third, rearing facilities and direction boards of law-protected trees should be placed and related education should be conducted. Fourth, through operation of the department for law-protected trees consisting of related professions and cooperation among related departments the trees should be maintained continuously.

Low-Power CMOS On-Chip Voltage Reference Circuits (저전력 CMOS On-Chip 기준전압 발생회로)

  • Kwon, Duck-Ki;Park, Jong-Tae;Yu, Chong-Gun
    • Journal of IKEEE
    • /
    • v.4 no.2 s.7
    • /
    • pp.181-191
    • /
    • 2000
  • In this paper, two schemes of generating reference voltages using enhancement-mode MOS transistors and resistors are proposed. The first one is a voltage-mode scheme where the temperature compensation is made by summing a voltage component proportional to a threshold voltage and a voltage component proportional to a thermal voltage. In the second one, that is a current-mode scheme, the temperature compensation is made by summing a current component proportional to a threshold voltage and a current component proportional to a thermal voltage. The designed circuits have been simulated using a $0.65{\mu}m$ n-well CMOS process parameters. The voltage-mode circuit has a temperature coefficient less than $48.0ppm/^{\circ}C$ and a power-supply(VDD) coefficient less than 0.21%/V for a temperature range of $-30^{\circ}C{\sim}130^{\circ}C$ and a VDD range of $3V{\sim}12V$. The current-mode circuit has a temperature coefficient less than $38.2ppm/^{\circ}C$ and a VDD coefficient less than 0.8%/V for $-30^{\circ}C{\sim}130^{\circ}C\;and\; 4V{\sim}12V$. The power consumption of the voltage-mode and current-mode circuits are $27{\mu}W\;and\;65{\mu}W$ respectively for 5V and $30^{\circ}C$. Measurement results show that the voltage-mode reference circuit has a VDD coefficient less than 0.63%/V for $30^{\circ}C{\sim}100^{\circ}C$ and has a temperature coefficient less than $490ppm/^{\circ}C\;for\;3V{\sim}6V$. The proposed reference circuits are simple and thus easy to design. The proposed current-mode reference circuit can be designed to generate a wide range of reference voltages.

  • PDF

Effects of heat treatment on the load-deflection properties of nickel-titanium wire (니켈-티타늄 와이어의 열처리에 따른 부하-변위 특성 변화)

  • Chang, Soo-Ho;Kim, Kwang-Won;Lim, Sung-Hoon
    • The korean journal of orthodontics
    • /
    • v.36 no.5
    • /
    • pp.349-359
    • /
    • 2006
  • Objective: Nickel-titanium alloy wire possesses excellent spring-back properties, shape memory and super-elasticity. In order to adapt this wire to clinical use, it is necessary to bend as well as to control its super-elastic force. The purpose of this study is to evaluate the effects of heat treatment on the load-deflection properties and transitional temperature range (TTR) of nickel-titanium wires. Methods: Nickel-titanium wires of different diameters ($0.016"\;{\times}\;0.022"$, $0.018"\;{\times}\;0.025"$ and $0.0215"\;{\times}\;0.028"$) were used. The samples were divided into 4 groups as follows: group 4, posterior segment of archwire (24 mm) without heat treatment; group 2, posterior segment of archwire (24 mm) with heat treatment only; group 3, anterior segment with bending and heat treatment; group 4, anterior segment with bending and 1 sec over heat treatment. Three point bending test was used to evaluate the change in load-deflection curve and obtained DSC (different scanning calorimetry) to check changes in $A_f$ temperature. Results: In the three point bending test, nickel-titanium wires with heat treatment only had higher load-deflection curve and loading and unloading plateau than nickel-titanium wires without heat treatment. Nickel-titanium wires with heat treatment had lower Af temperature than nickel-titanium wires without heat treatment. Nickel-titanium wires with heat treatment and bending had higher load-deflection curve than nickel- titanium wires with heat treatment and nickel-titanium wires without heat treatment. Nickel-titanium with heat treatment of over 1 sec and bending had the highest load-deflection curve. Nickel-titanium wires with heat treatment and bending had lower Af temperature, Nickel-titanium wires with heat treatment of over Af sec and bending had the lowest Af temperature. Conclusion: From the results of this study, it can be stated that heat treatment for bending of Nickel-titanium wires does not deprive the superelastic property but can cause increased force magnitude due to a higher load-deflection curve.

Estimation of $CO_2$ saturation from time-lapse $CO_2$ well logging in an onshore aquifer, Nagaoka, Japan (일본 Nagaoka 육상 대수층에서 시간차 $CO_2$ 물리검층으로부터 $CO_2$ 포화도의 추정)

  • Xue, Ziqiu;Tanase, Daiji;Watanabe, Jiro
    • Geophysics and Geophysical Exploration
    • /
    • v.9 no.1
    • /
    • pp.19-29
    • /
    • 2006
  • The first Japanese pilot-scale $CO_2$ sequestration project has been undertaken in an onshore saline aquifer, near Nagaoka in Niigata prefecture, and time-lapse well logs were carried out in observation wells to detect the arrival of injected $CO_2$ and to evaluate $CO_2$ saturation in the reservoir. $CO_2$ was injected into a thin permeable zone at the depth of 1110m at a rate of 20-40 tonnes per day. The total amount of injected $CO_2$ was 10400 tonnes, during the injection period from July 2003 to January 2005. The pilot-scale demonstration allowed an improved understanding of the $CO_2$ movement in a porous sandstone reservoir, by conducting time-lapse geophysical well logs at three observation wells. Comparison between neutron well logging before and after the insertion of fibreglass casing in observation well OB-2 showed good agreement within the target formation, and the higher concentration of shale volume in the reservoir results in a bigger difference between the two well logging results. $CO_2$ breakthrough was identified by induction, sonic, and neutron logs. By sonic logging, we confirmed P-wave velocity reduction that agreed fairly well with a laboratory measurement on drilled core samples from the Nagaoka site. We successfully matched the history changes of sonic P-wave velocity and estimated $CO_2$ saturation a(ter breakthrough in two observation wells out of three. The sonic-velocity history matching result suggested that the sweep efficiency was about 40%. Small effects of $CO_2$ saturation on resistivity resulted in small changes in induction logs when the reservoir was partially saturated. We also found that $CO_2$ saturation in the $CO_2$-bearing zone responded to suspension of $CO_2$ injection.

The Effect of Electrode Spacing and Size on the Performance of Soil Microbial Fuel Cells (SMFC) (전극간 거리와 크기가 토양미생물연료전지의 성능에 미치는 영향)

  • Im, Seong-Won;Lee, Hye-Jeong;Chung, Jae-Woo;Ahn, Yong-Tae
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.36 no.11
    • /
    • pp.758-763
    • /
    • 2014
  • Soil microbial fuel cells (SMFC) have gained a great attention as an eco-friendly technology that can simultaneously generate electricity and treat organic pollutants from the contaminated soil. We evaluated the effect of electrode spacing and size on the performance of SMFC treating soil contaminated with organic pollutants. Maximum power density decreased with increase in electrode distance or decrease in electrode size, likely due to higher internal resistance. The maximum voltage and power density decreased from 326 mV and $19.5mW/m^2$ with 4 cm of electrode distance to 222 mV and $5.9mW/m^2$ with 9 cm of electrode distance. In case of electrode size test, the maximum voltage and power density generated was 291 mV, $0.34mW/m^3$ when both of anode and cathode area were $64cm^2$ with 4 cm of electrode distance. The maximum voltage decreased by 19~29% when the anode area decreased to $16cm^2$ while only 3~12% of voltage decreased with cathode area decrease. The maximum power density decreased by 49~68% with decreasing anode size, and by 29~47% with decreasing cathode size. These results showed that the anode area had more significant effects than the cathode area on the power generation of SMFC which has a high internal resistance due to a coexistence of soil and wastewater in the reactor.

A Study on the Spatial and Visual Composition of Yi Ung-Jae's Old House, Dundeok-ri (둔덕리 이웅재고가(李雄宰古家)의 공간 및 경관 구성적 특성에 관한 연구)

  • Rho, Jae-Hyun;Lee, Jung-Han
    • Journal of the Korean Institute of Traditional Landscape Architecture
    • /
    • v.38 no.2
    • /
    • pp.60-76
    • /
    • 2020
  • The purpose of this study was to examine the spatial and visual arrangement characteristics of Imsil Yi Ung-jae's old house's spatial and visual aspects in order to discover the value of landscape and traditional house garden. The results of this study are as follows. Dongchon-village in Dundeok-ri, where old house is located, is a typical form of with "Back to the mountain and facing the water(背山臨水)", and is located in the north of the three streams of water, forming a Jeonchaghugwan(前窄後寬). Dongchon Village, which has a traditional scenic spot between Danguidae(丹丘臺) and Samgyeseokmun(三溪石門), is understood to be the main street of Nojeokbong Peak and Gyegwanbong Peak, which is Ansan(案山), where the "A centipede flying in the sky(飛天蜈蚣形)". Yi Ung-jae's old house is the oldest existing high-priced house in the North Jeolla region and the closing price of a royal family of the Joseon Dynasty, which was arranged by Chunseongjeong(春城正), Yi Dam-son(李聃孫) in the mid-16C. The Japanese Invasion of Korea in 1592 and Japanese colonial era, the loyalty of the gate quarters, the filial piety of the gate quarters, and the faithfulness of the tablet(扁額) and Juryeons(柱聯) are enough to contribute to the rise of the value of a physical house. The men's quarters(Sarangchae), which are placed on a high-pocket or a layout without going against the sloping terrain, have the effect of making the distance as far as possible, enhancing its dignity and hierarchy as a royal building. In addition, the entrance to the main quarters(Anchae) through the four pillar gates(四柱門), the extensive support and the appropriation of the Chaewon(vegetable garden), and the official base for the Anchae are very unique compared to the general nobility. However, in the context of the postwar relationship, the shrine seeks to realize Confucian ideals while harmonizing with nature by arranging wide sponsorships around it. On the other hand, it is confirmed that there was a pond in the form of a circle in a square(方池圓島型) with a relatively large area, which is now disturbed and damaged. Written by the high priced planting species are sponsored pine trees, hackberry, persimmon trees, Japanese apricot flower, Ohmomiji, and plum tree in the side garden, as well as cotyledon trees in the outside garden. However, although flower bed(花階), which is built on the stone axis, is a place that clearly shows the expensive garden, it seems to have lost the texture of the plant due to the extremely high variety of species and the splendor that does not match the plant landscape of the flower world. Yi Ung-jae's old house is highly valuable as it is a portrait house of a prince of the blood in the mid-Joseon Dynasty. Based on these findings, this study proposed a plan to improve the management of high prices that could be met.

Development of a High Heat Load Test Facility KoHLT-1 for a Testing of Nuclear Fusion Reactor Components (핵융합로부품 시험을 위한 고열부하 시험시설 KoHLT-1 구축)

  • Bae, Young-Dug;Kim, Suk-Kwon;Lee, Dong-Won;Shin, Hee-Yun;Hong, Bong-Guen
    • Journal of the Korean Vacuum Society
    • /
    • v.18 no.4
    • /
    • pp.318-330
    • /
    • 2009
  • A high heat flux test facility using a graphite heating panel was constructed and is presently in operation at Korea Atomic Energy Research Institute, which is called KoHLT-1. Its major purpose is to carry out a thermal cycle test to verify the integrity of a HIP (hot isostatic pressing) bonded Be mockups which were fabricated for developing HIP joining technology to bond different metals, i.e., Be-to-CuCrZr and CuCrZr-to-SS316L, for the ITER (International Thermonuclear Experimental Reactor) first wall. The KoHLT-1 consists of a graphite heating panel, a box-type test chamber with water-cooling jackets, an electrical DC power supply, a water-cooling system, an evacuation system, an He gas system, and some diagnostics, which are equipped in an authorized laboratory with a special ventilation system for the Be treatment. The graphite heater is placed between two mockups, and the gap distance between the heater and the mockup is adjusted to $2{\sim}3\;mm$. We designed and fabricated several graphite heating panels to have various heating areas depending on the tested mockups, and to have the electrical resistances of $0.2{\sim}0.5$ ohms during high temperature operation. The heater is connected to an electrical DC power supply of 100 V/400 A. The heat flux is easily controlled by the pre-programmed control system which consists of a personal computer and a multi function module. The heat fluxes on the two mockups are deduced from the flow rate and the coolant inlet/out temperatures by a calorimetric method. We have carried out the thermal cycle tests of various Be mockups, and the reliability of the KoHLT-1 for long time operation at a high heat flux was verified, and its broad applicability is promising.