• Title/Summary/Keyword: 전기임피던스

Search Result 1,220, Processing Time 0.027 seconds

Study on Sound Reflection Control using an Active Sound Absorber (능동흡음재를 이용한 음파반사 제어기법 연구)

  • Chang, Woo-Suk;Gweon, Dae-Yong
    • The Journal of the Acoustical Society of Korea
    • /
    • v.28 no.8
    • /
    • pp.806-814
    • /
    • 2009
  • This paper reviews a study about sound reflection control using an active sound absorber. An active sound absorber includes sound transmitting and receiving piezocomposite sensor layers molded by water tight epoxy, and connected with a feedback controller. The multi-layer sensors and the controller consists a closed feedback loop, whose intrinsic characteristics shows excellent impedance matching performance within specified frequency band, and consequently, minimizes reflection waves. Multilayer sound transmission model is derived based on one dimensional model, and its performance is verified with experiment using a pulse tube setup.

Variation of AC Impedance of the $TiS_2$ Composite/SPE/Li Cell with Cycling ($TiS_2$ Composite/SPE/Li Cell의 충방전에 따른 AC 임피던스의 변화)

  • Kim, J.U.;Gu, H.B.;Moon, S.I.;Yun, M.S.
    • Proceedings of the KIEE Conference
    • /
    • 1995.07c
    • /
    • pp.1034-1038
    • /
    • 1995
  • The purpose of this study is to research and develop $TiS_2$ composite cathode for lithium polymer battery(LPB). $TiS_2$ electrode represent a class of insertion positive electrode used in Li secondary batteries. In this study, we investigated preparation of $TiS_2$ composite cathode and AC impedance response of $TiS_2$ composite/SPE/Li cells as a function of state of charge(SOC) and cycling. The resistance of B type cell using $TiS_2PEO_8LiClO_4PC_5EC_5$ composite cathode was lower than that of A type cell using $TiS_2PEO$ composite cathode. The cell resistance of B type cell is high for the first few percent discharge, decreases for midium discharge and then increases again toward the end of discharge. We believe the magnitude of the cell resistance is dominated by passivation layer impedance and small cathode resistance. AC impedance results indicate that the cell internal resistance increase with cycling, and this is attributed to change of passivation layer impedance with cycling. The passivation layer resistance($R_f$) of B type cell decreases for the 2nd cycling and then increases again with cycling. Redox coulombic efficiency of B type cell was about 141% at 1st cycle and 100% at 12th cycle. Also, $TiS_2$ specific capacity was 115 mAh/g at 12 cycle.

  • PDF

Are the Economic and Convenient Anthropometric Estimations Reliable Tools for Assessing Body Fat of University Students? (인체계측과 생체전기측정법의 비교를 통한 경제성과 타당성을 지닌 체지방 측정법 제안 - 일 대학 남녀 대학생을 대상으로 -)

  • Kim, Hack-Sun;Jun, Myung-Hee;Park, Young-Im;Uhm, Dong-Choon;Kim, Dal-Sook
    • The Journal of Korean Academic Society of Nursing Education
    • /
    • v.14 no.2
    • /
    • pp.305-314
    • /
    • 2008
  • Purpose: The purpose of the study was to examine whether anthropometric estimations can be reliable methods to assess body fat of university students, by identifying the relationship between anthropometric estimates, which have been thought to be not reliable but economic, and Bio-electric impedance analysis (BIA), which has been known to be reliable but expensive. Method: Twenty-one male and 20 female university students were recruited. The in Body 3.0 scale and GIF-891DX were used for BIA. Body fat was estimated with 12 circumferences, 9 skin-fold thicknesses (SFT), and applying 4 equations (Kim's, $Broz{\check{e}}k's$, Siri's and Wilmore's). Their relationships were examined by Pearson Correlation. Result: 11 circumferences and 9 SFT in the male while 5 circumferences and 3 SFT in the female correlated with the body fat on BIA(p<05). The waist circumference had the strongest correlation to the BIA in both males and females. The abdomonial SFT for the male and scapular SFT for the female had the strongest relationship of SFT to BIA. Body fat estimated from more than two different equations significantly correlated with those measured from BIA (p<.05). Conclusion: Anthropometric estimations could be a useful method to get reliable and valid data for body fat of the university students inexpensively.

Fabrication and Characterization of Pyrolyzed Carbon for Use as an Electrode Material in Electrochemical Biosensor (전기화학 바이오센서의 전극물질로 응용을 위한 열분해 탄소의 제작 및 특성 연구)

  • Lee, Jung-A.;Hwang, Seong-Pil;Kwak, Ju-Hyoun;Park, Se-Il;Lee, Seung-Seob;Lee, Kwang-Cheol
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.31 no.10
    • /
    • pp.986-992
    • /
    • 2007
  • This paper presents the fabrication and characterization of carbon films pyrolyzed with various photoresists for bioMEMS applications. To verify the usefulness of pyrolyzed carbon films as an electrode material in an electrochemical biosensor developed by the authors, interactions between avidin and biotin on the pyrolyzed carbon film were studied via electrochemical impedance spectroscopy based on electrostatic interactions between avidin and negatively-charged ferricyanide. The pyrolyzed carbon films were characterized using a surface profiler, a precision semiconductor parameter analyzer, a nanoindentor, scanning electron microscopy, and atomic force microscopy. Amine conjugated biotin was immobilized on the electrode using EDC/NHS as crosslinkers after $O_2$ plasma treatment to enhance functional groups on the carbon electrode pyrolyzed at $1000^{\circ}C$ with AZ9260. The detection of avidin binding with different concentrations in a range of 0.75 nM to $7.5\;{\mu}M$ to the pyrolyzed carbon electrode modified with biotin was carried out by measuring the electrochemical impedance change. The results show that avidin binds to the biotin on the electrode not by non-specific interaction but by specific interaction, and that EIS successfully detects this binding event. Pyrolyzed carbon films are a promising material for miniaturization, integration, and low-cost fabrication in electrochemical biosensors.

Development of High-performance Supercapacitors Based on MnO2/Functionalized Graphene Nanocomposites (망간산화물/기능화된 그래핀 나노복합체에 기반한 고성능 슈퍼커패시터 개발)

  • Choi, Bong Gill
    • Applied Chemistry for Engineering
    • /
    • v.27 no.4
    • /
    • pp.439-443
    • /
    • 2016
  • In this report, $MnO_2$ nanoparticle-deposited functionalized graphene sheets were prepared and their superior electrochemical performances were demonstrated by cyclic voltammetry, galvanostatic charge-discharge, and impedance analysis. Ionic liquids were employed to functionalize the surface of reduced graphene oxides (RGOs), leading to prevention of the aggregation of RGO sheets and abundant growth sites for deposition of $MnO_2$ nanoparticles. As-prepared $MnO_2/RGO$ nanocomposites were characterized using scanning electron microscope, transition electron microscope, X-ray photoelectron spectroscopy, and X-ray diffraction. Electrochemical properties of $MnO_2/RGO$ electrode were evaluated using $Na_2SO_4$ electrolyte under a three-electrode system. The $MnO_2/RGO$ electrode showed a high specific capacitance (251 F/g), a high rate capability (80.5% retention), and long-term stability (93.6% retention).

Characteristics of Sulfonated Poly(arylene ether sulfones) Cation-Exchange Membrane by Variation of Sulforic Acid Group Concentration (술폰화 poly(arylene ether sulfones) 양이온 교환막의 술폰산기 농도 변화에 따른 특성)

  • Kim Lae Hyun;Lee Seung Yong;Choi Sun Yong;Lee Joung Woo;Park Sei Yong
    • Journal of the Korean Electrochemical Society
    • /
    • v.3 no.1
    • /
    • pp.57-62
    • /
    • 2000
  • Sulfonated Polysulfone (SPSF) cation-exchange membranes were synthesized by introducing various ratio of chlorosulfuric acid (CSA) onto the main chain of polysulfone (PSF). Properties such as ion exchange capacity, water content, liked ion concentration, and partition coefficient were measured, respectively. Through the analysis of DSC and TGA, it has been shown that glass transition temperature increased and weight loss decreased as sulfuric acid group concentration increased. Structure of membrane measured by AFM and SEM was seen to be asymmetric. Apparent diffusion coefficient of sodium ions through SPSF membrane by AC impedance was increased as sulfuric acid group concentration increased.

0.6 mAh All-Solid-State Thin Fim Battery Fabricated on Alumina Substrate (알루미나 기판상에 구현된 0.6mAh급 전고상 박막전지)

  • Park, H.Y.;Nam, S.C.;Lim, Y.C.;Choi, K.G.;Lee, K.C.;Park, G.B.;Cho, S.B.
    • Journal of the Korean Electrochemical Society
    • /
    • v.8 no.4
    • /
    • pp.181-185
    • /
    • 2005
  • Lithium cobalt oxide thin film cathode, having thickness of $2.9{\mu}m$ with area of $4cm^2$, was deposited on platinum patterned alumina substrate by radio frequency magnetron sputtering. Li/Co molar ratio, which is an important factor for battery performance, was measured as a function of argon working pressure and applied R.F. power. Constant current charge and discharge performances were characterized with high rate discharge and cycling behavior. Using AC impedance analysis, internal resistance of the thin film battery was measured and simulated by proposed equivalent circuit model.

Comparative Studies on Ammonium Ion Selective Electrodes Using Poly(Vinyl Chloride) and Polyurethane as Substrate Matrix Materials (Poly(Vinyl Chloride)와 Polyurethane을 지지체로 사용한 암모늄이온 선택성 전극의 특성비교)

  • Cho Chang-Ae;Park Su-Moon
    • Journal of the Korean Electrochemical Society
    • /
    • v.7 no.3
    • /
    • pp.148-154
    • /
    • 2004
  • Ammonium ion selective electrodes have been prepared using nonactin as an ionophore and poly(vinyl chloride) (PVC) or polyurethane(PU) as a polymer matrix with or without a plasticizer, bis(2-ethylhexyl) adipate, and their performances have been evaluated. The reults indicate that PU-based electrodes can be designed to perform better although PVC-based electrodes generally show better performances. In efforts to explain the obervation, we also carried out atomic force microscopy as well as impedance studies, and the results suggests that islands of ion-ophores are formed in the PVC membranes through which ion transfers appear to be more facile than through the PU membranes. The PU membranes appear to have ionophores better dispersed throughout the film and are more resistive to ion mobilities in comparison to PVC films.

Characteristics of The 1-3 Piezoelectric Composite Transducer Manufactured by Dicing-Filling Method (Dicing-Filling 방법으로 제작된 1-3 압전복합변환자의 특성)

  • Kim, W.S.;Yun, U.H.;Ok, C.I.;Kim, S.B.;Lee, J.K.;Lee, J.O.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.20 no.1
    • /
    • pp.33-37
    • /
    • 2000
  • The 1-3 piezoelectric composite transducer with 75 volume percents PZT was fabricated by the dicing-filling method. The resonance modes of the 1-3 transducer have been studied with electric impedance measurement as a function of frequency. The fundamental frequencies of the planar and thickness mode were observed at 0.95MHz and 1.63MHz respectively, but the lateral mode was not observed. In the thickness mode, the electromechanical coupling coefficient of the 1-3 piezoelectric composite transducer, 0.54, was very closed to that of the single phase PZT(0.52). The pulse-echo response by exciting the 1-3 transducer with an electric pulse was observed from the water/reflector interface, and analyzed bandwidth by the spectrum of the impulse response. The quality factor Q for the 1-3 transducer was observed as 1.5 smaller than that of the single phase(80) and then the 1-3 transducer may be used to the broad band type transducer applications.

  • PDF

Characteristic Analysis of Voltage Sags Due to Faulted Distribution Lines (배전선로 고장에 의한 Voltage Sag의 특성 해석)

  • ;Madhat M. Morcos
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.16 no.1
    • /
    • pp.76-84
    • /
    • 2002
  • Voltage sags caused by line faults in transmission and distribution lines have become one of the most important power quality problems facing industrial customers and utilities. Voltage sags are normally described by characteristics of both magnitude and duration, but phase angle shifts should be taken account in identifying sag phenomena and finding their solutions. In this paper, voltage sags due to line faults such as three phase-to-ground, single line-to-ground, and line-to-line faults are characterized by using symmetrical component analysis, for fault impedance variations. Voltage sags and their effect on the magnitude and phase angle are examined. Balanced sags of three phase-to-ground faults show that voltages and currents are changed with equivalent levels to all phases and the zero sequence components become zero. However, for unbalanced faults such as single line-to-ground and line-to-line faults, voltage sags give different magnitude variations and phase angle shifts for each phase. In order to verify the analyzed results, some simulations based on power circuit models are also discussed.