• Title/Summary/Keyword: 전기신호측정

Search Result 918, Processing Time 0.038 seconds

Thermal Memory Effect Modeling and Compensation in Doherty Amplifier (Doherty 증폭기의 열 메모리 효과 모델링과 보상)

  • Lee Suk-Hui;Lee Sang-Ho;Bang Sung-Il
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.42 no.9 s.339
    • /
    • pp.49-56
    • /
    • 2005
  • Memory effect, which influence the performance of Doherty amplifier, become more significant and critical in designing these circuits as the modulation signal bandwidth and operation power level increase. This paper reports on an attempt to investigate, model and quantity the contribution of the electrical nonlinearity effects and the thermal memory effects to a Doherty amplifier's distortion generation. Also this raper reports on the development of an accurate dynamic expression of the instantaneous junction temperature as a function of the instantaneous dissipated power. This expression has been used in the construction of an electrothermal model for the Doherty amplifier. Parameters for the nelv proposed behavior model were determined from the Doherty amplifier measurements obtained under different excitation conditions. This study led us to conclude that the effects of the transistor self-heating phenomenon are important for signals with wideband modulation bandwidth(ex. W-CDMA or UMTS signal). Doherty amplifier with electrothermal memory effect compensator enhanced ACLR performance about 20 dB than without electrothemal memory effect compensator. Experiment results were mesured by 60W LDMOS Doherty amplifier and electrothermal memory effect compensator was simulated by ADS.

Development of Oriental-Western Fusion Patient Monitor by Using the Clip-type Pulsimeter Equipped with a Hall Sensor, the Electrocardiograph, and the Photoplethysmograph (홀센서 집게형 맥진기와 심전도-용적맥파계를 이용한 한양방 융합용 환자감시장치 개발연구)

  • Lee, Dae-Hui;Hong, Yu-Sik;Lee, Sang-Suk
    • Journal of the Korean Magnetics Society
    • /
    • v.23 no.4
    • /
    • pp.135-143
    • /
    • 2013
  • The clip-type pulsimeter equipped with a Hall sensor has a permanent magnet attached in the "Chwan" position to the center of a radial artery. The clip-type pulsimeter is composed of a hardware system measuring voltage signals. These electrical bio-signals display pulse rate, non-invasive blood pressure, respiratory rate, pulse wave velocity (PWV), and spatial pulse wave velocity (SPWV) simultaneously measured by using the radial artery pulsimeter, the electrocardiograph (ECG), and the photoplethysmograph (PPG). The findings of this research may be useful for developing a oriental-western biomedical signal storage device, that is, the new and fusion patient monitor, for a U-health-care system.

The development of the photoreflectance program for the analysis of semiconductor optical properties

  • Shin, Sang-Hoon;Kim, Geun-Hyeong
    • Journal of the Korea Society of Computer and Information
    • /
    • v.27 no.8
    • /
    • pp.211-218
    • /
    • 2022
  • In this paper, a computer simulation program was developed to interpret the results measured by photoreflectance spectroscopy. The developed program is implemented so that the user can easily change the factors required for optical modulation characteristic interpretation, and the result of the value can be checked simultaneously with the actual measurement result. The results obtained by photoreflectance spectroscopy are obtained by mixing a third derivative function form (TDFF) modulated around a bandgap with a Franz-Keldysh oscillation (FKO) signal due to an electric field at a surface and an interface higher than the bandgap. Through the computer simulation program, the optical characteristics that appear in the GaSb Epi layer formed as a single layer were analyzed, and very useful results were obtained by specializing in optical modulation analysis. In addition, a Fast Fourier Transform (FFT) analysis tool was added to facilitate frequency characteristics analysis of FKO.

A study on Evaluating Validity of SNR Calculation Using a Conventional Two Region Method in MR Images Applied a Multichannel Coil and Parallel Imaging Technique (다중채널코일과 병렬영상기법 이용 시 두영역측정법을 사용한 신호대잡음비 측정의 문제점)

  • Choi, Kwan-Woo;Son, Soon-Yong;Min, Jung-Whan;Kwon, Kyung-Tae;Yoo, Beong-Gyu;Lee, Jong-Seok
    • Journal of radiological science and technology
    • /
    • v.38 no.4
    • /
    • pp.403-410
    • /
    • 2015
  • The purpose of this study was to investigate the problems of a signal to noise ratio measurement using a two region measurement method that is conventionally used when using a multi-channel coil and a parallel imaging technique. As a research method, after calculating the standard SNR using a single channel head coil of which coil satisfies three preconditions when using a two region measurement method, we made comparisons and evaluations after calculating an SNR by using a two region measurement method of which method is problematic because it is used without considering the methods recommended by reputable organizations and the preconditions at the time of using a multi-channel coil and a parallel imaging technique. We found that a two region measurement method using a multi-channel coil and a parallel imaging technique shows the highest relative standard deviation, and thus shows a low degree of precision. In addition, we found out that the difference of SNR according to ROI location was very high, and thus a spatial noise distribution was not uniform. Also, 95% confidence interval through Blend-Altman plot is the widest, and thus the conformity degree with a two region measurement method using the standard single channel head coil is low. By directly comparing an AAPM method, which serves as a standard of a performance evaluation test of a magnetic resonance imaging device under the same image acquisition conditions, an NEMA method which can accurately determine the noise level in a signal region and the methods recommended by manufacturers of a magnetic resonance imaging device, there is a significance in that we quantitatively verified the inaccurate problems of a signal to noise ratio using a two region measurement method when using a multi-channel coil and a parallel imaging technique of which method does not satisfy the preconditions that researchers could overlook.

Rehabilitative Effect of Intramuscular Electrostimulation after Reconstruction of Medial Patellar Luxation in Small Sized Dog (소형견의 내측 슬개골 탈구 정복술 후 근육 내 전기자극의 재활효과)

  • Lee, Shinho;Lee, Joo-Myoung;Park, Hyunjung;Won, Sangcheol;Cheong, Jongtae
    • Journal of Veterinary Clinics
    • /
    • v.32 no.1
    • /
    • pp.16-21
    • /
    • 2015
  • Medial patellar luxation (MPL) of dog is one of the most common joint diseases. This study performed to know rehabilitative effect after reconstruction as application with intramuscular electrostimulation (IMES) on the cranial part of sartorius muscle. In this study, the 12 dogs with operated medial luxation divided into electrostimulation group (n = 8) and no electrostimulation group (n = 4) measured affected sided range of motion, muscle mass, lameness score and weight bearing for hospitalization 2 weeks. IMES group showed significant results after operation on 5th day (p < 0.01). Except lameness score, IMES group showed significant results on 10th day (p < 0.05). As results, in small sized dog after reconstruction of MPL, IMES on the cranial part of sartorius muscle considered a great help in the initial rehabilitation.

산화공정을 통해 제작 된 전이금속산화물 박막의 저항변화 특성 연구

  • Seong, Yong-Heon;Go, Dae-Hong;Kim, Sang-Yeon;Do, Gi-Hun;Seo, Dong-Chan
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2009.11a
    • /
    • pp.30.1-30.1
    • /
    • 2009
  • 정보화가 급속히 진전됨에 따라 보다 많은 양의 정보를 전송, 처리, 저장하게 되면서 이를 위해 대용량, 고속, 비휘발성의 특징을 갖는 차세대 메모리의 개발이 절실히 요구되고있다. 이 중 저항 변화 메모리(ReRAM)는 일반적으로 TiO2, Al2O3, NiO2, HfO2, ZrO2 등의 전이금속산화물을 이용한 MIM 구조로서 적당한 전기 신호를 가하면 저항이 높아서 전도되지 않는 상태(Offstate)에서 저항이 낮아져 전도가 가능한 상태(On state)로 바뀌는 메모리 특성을가진다. ReRAM은 비휘발성 메모리이며 종래의 비휘발성 기억소자인 Flash memory 보다 access time 이105 배 이상 빠르고, 5V 이하의 낮은 전압에서도 동작이 가능하다. 또한 구조가 간단하여 공정 단순화가 가능하고 소자의 집적화도 쉽다는 점 등 많은 장점들이 있어서 Flash memory를 대체할 수 있는 유력한 후보로 여겨지고 있다. 본연구에서는 DC-magnetron Sputtering 방법으로 전이금속 박막을 증착하고, Dry furnace로 산화시켜 전이금속산화물 박막을 제작한 후 저항변화 특성을 연구하였다. 두 개의 전이금속산화물 박막을 dual-layer로 형성시켜 저항변화특성을 관찰하였으며 또한, 전이금속산화물 박막의 조성을 달리 하여 저항변화를 관찰 하였다. 전이금속산화물 박막의 전기적 특성을 알아보기 위해 Si(100) wafer 위에 Pt를 이용 MIM 형태로 capacitor 시편을 제작 하여, probe station으로 I-V 측정을 하였고 조성 및 표면 분석을 위해서는 AES와 AFM을, 미세구조를 분석을 위해서는 TEM과 SEM 을 사용하였다.

  • PDF

A Study on Digital Control Method of LED Luminance (LED 휘도의 디지털 제어 방식에 관한 연구)

  • Kang, Shin-Ho;Ryeom, Jeong-Duk
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.1
    • /
    • pp.28-34
    • /
    • 2010
  • The pulse width modulation(PWM) method has been generally used as conventional method controlling luminance of LED(light emitting diode). PWM method as analog method with a relation that duty ratio of LED be proportional to luminance has weak point that it is not compatible with digital method of communication etc. In this paper, a experiment is conducted which the luminance of RGB LED be controlled by digital method. For this, the LED digital control system is developed which consist of LED driving circuits and digital logic circuits. By controlling the number of pluses on RGB LED versus digital input, various lighting colors is implemented and digital codes are optimized in order that measured x, y chromaticity coordinates of lighting colors are comprised in the CIE chromaticity coordinates area of targeted lighting colors. The result of this study can be utilized usefully in research on implementing full color by using remote control of LED lamp with digital communication.

Design of a Timing Error Detector Using Built-In current Sensor (내장형 전류 감지회로를 이용한 타이밍 오류 검출기 설계)

  • Kang, Jang-Hee;Jeong, Han-Chul;Kwak, Chol-Ho;Kim, Jeong-Beom
    • Journal of IKEEE
    • /
    • v.8 no.1 s.14
    • /
    • pp.12-21
    • /
    • 2004
  • Error control is one of major concerns in many electronic systems. Experience shows that most malfunctions during system operation are caused by transient faults, which often mean abnormal signal delays that may result in violations of circuit element timing constraints. This paper presents a novel CMOS-based concurrent timing error detector that makes a flip-flop to sense and then signal whether its data has been potentially corrupted or not by a setup or hold timing violation. Designed circuit performs a quiescent supply current evaluation to determine timing violation from the input changes in relation to a clock edge. If the input is too close to the clock time, the resulting switching transient current in the detection circuit exceeds a reference threshold at the instant of the clock transition and an error is flagged. The circuit is designed with a $0.25{\mu}m$ standard CMOS technology at a 2.5 V supply voltage. The validity and effectiveness are verified through the HSPICE simulation. The simulation results in this paper shows that designed circuit can be used to detect setup and hold time violations effectively in clocked circuit element.

  • PDF

An 8b 52 MHz CMOS Subranging A/D Converter Design for ISDN Applications (광대역 종합 통신망 응용을 위한 8b 52 MHz CMOS 서브레인징 A/D 변환기 설계)

  • Hwang, Sung-Wook;Lee, Seung-Hoon
    • Journal of IKEEE
    • /
    • v.2 no.2 s.3
    • /
    • pp.309-315
    • /
    • 1998
  • This paper describes an 8b 52 MHz CMOS subranging analog-to-digital converter (ADC) for Integrated Services Digital Network (ISDN) applications. The proposed ADC based on the improved time-interleaved architecture removes the holding time which is typically observed in the conventional double-channel subranging ADCs to increase throughput rate. Moreover, the ADC employs the interpolation technique in the back-end subranging ADCs far residue signal processing to minimize die area and power consumption. The fabricated and measured prototype ADC in a 0.8 um n-well double-poly double-metal CMOS process typically shows a 52 MHz sampling rate at a 5 V supply voltage with 230 mW, and a 40 MHz sampling rate at a 3 V power supply with 60 mW power consumption.

  • PDF

Measurement of thermal conductivity of fluid by unsteady hot wire method (非定常 熱線法 에 의한 流體 의 熱傳達率 測定)

  • 고상근;양상식;노승탁
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.8 no.2
    • /
    • pp.154-161
    • /
    • 1984
  • A modified technique of the transient hot wire method to measure the thermal conductivity of fluid has been described in this paper. The thermal conductivity of fluid can be obtained by acquiring wire temperature as a function of time. Multiplication of the inverse slope of the temperature versus logarithm of time by an instrumental constant gives the thermal conductivity. The constant voltage was applied to Wheatstone bridge circuit. The wire temperature can be measured as a function of time precisely with the aid of the data acquisition system composed of a microprocessor and an analog-digital converter. The thermal conductivity of the electrically conducting fluid has been measured with the insulated hot wire coated by electrically non-conducting material. The effect of the coated insulation layer on the thermal conductivity has been examined, in which it is confirmed that the thermal conductivity of electrically conducting liquid can be determined by the transient coated hot wire method. Thermal conductivities of methanol, carbontetrachrolide, Freon-22 and glycerin have been measured at room temperature in the pressure from 0.1MPa to 35.1MPa. The experiment has been performed to compare the data from the bare and the coated wires, and the results are satisfactory.