• Title/Summary/Keyword: 전기신호측정

Search Result 918, Processing Time 0.028 seconds

Measurement of Basis Signal with HFCT for Diagnosing Partial Discharge in Middle Joint Box of 154kV Grade (154kV급 중간접속부내의 부분방전 진단을 위한 HFCT 적용 기준신호 측정연구)

  • Lee, Yong-Sung;Kim, Jung-Yoon;Lee, Kyung-Yong;Choi, Yong-Sung;Park, Dae-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2005.11a
    • /
    • pp.217-219
    • /
    • 2005
  • To detect partial discharge of 154kV joint box, we have made experiment by using the HFCT sensor. Generally the signals which are detected in partial discharge test of underground power transmission cable are accompanied with both noises of high voltage and noises of surrounding power cable. The most noise in near to end part of joint box is corona, beside other noises flowed from surrounding area. Partial discharge test is difficulty due to these noises. First, we test reliability on both injection of calibration signal in NJB and removal of low frequency. After that, we had analyzed frequencies by measuring signals in IJB with 300[m] distance from NJB. Also we had measured S/N ratio by using the indirected injection method of calibration signal in IJB. In this experiment, two measurement methods were difference of detection acquisition, but these had the equal frequency properties.

  • PDF

Improvement Plans of Railway standards for Surge Protective Devices used in Low-voltage Power circuits (저전압 전원용 서지보호장치 철도 규격의 개선방안)

  • 정용철;김언석;이재호;조봉관;김재철
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.16 no.2
    • /
    • pp.90-97
    • /
    • 2002
  • In this paper we study the performance test items and improvement plans of surge protective devices for low-voltage power circuits used in railway system. Above of all, the sources of electromagnetic interference in railway system are researched. And then we compared domestic railway standard with IEC and IEEE standards far the test items and methodologies of surge protective devices. Through the investigations, we found that the domestic standard is behind in the number of test items and methods on surge protective devices. As the countermeasures, we suggest removing component tests of surge protective devices, separating standards for power and signal standards, and using international surge waveform. In applying to domestic railway surge protective devices, surge limiting voltage measuring and surge endurance tests by international standard methods are good result.

A Characteristics of RF Sensitivity for a Firing Fuse (기폭용 퓨즈의 RF 감도 특성)

  • 간종만;권준혁
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.15 no.6
    • /
    • pp.573-578
    • /
    • 2004
  • EED consists of bridgewire, explosive charge, lead pins and metal case. If a firing signal is injected to EED, the explosive charge in EED is initiated by heating of bridgewire. Electromagnetic waves radiated from high power transmitters or radars can also cause unexpected firing of EED. Therefore, EMC design and test requirements for EED in military specifications are established and applied. This report describes the characteristics of RF sensitivity fur a firing fuse which is used fur EMC test instead of a real EED installed in aircraft. RF firing level of the fuse was predicted using transmission line(TL) theory. n sensitivity and RF sensitivity specified in military specifications were measured.

Surface modification using KrF laser irradiation for properties improvement of poros siloxane materials (다공성 실록샌 물질의 박막특성 향상을 위한 KrF laser 표면개질)

  • Kim, Jung-Bae;Jeong, Hyun-Dam;Lee, Sun-Young;Yim, Jin-Heong;Rhee, Ji-Hoon;Shin, Hyeon-Jin
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.11a
    • /
    • pp.240-243
    • /
    • 2002
  • 반도체 소자의 고속화, 고접적화에 따라 집적회로의 최소 선폭이 감소할수록 device 의 신호지연, 잡음 및 전력소모 등이 증가하는 문제점이 있다. 이러한 문제점을 개선하기 위해서 저유전율의 층간 절연막이 절대적으로 필요하다. 본 실험에서는 KrF laser 조사를 이용한 표면개질 방법으로 다공성 절연막의 박막특성의 향상을 시도하였다. 다공성 절연막을 층간 절연막으로 응용할 경우 반도체 공정 적용성을 향상시키기 위하여 다공성 절연막의 표면개질이 필요하다. 표면개질 전후의 유전율 변화는 박막을 MIM구조로 측정하였고 화학 구조의 변화는 time-of flight secondary ion mass spectrometry(TOF-SIMS)를 이용하여 관찰하였다. 다공성 실록샌 물질의 pore로 인해서 생긴 누설전류 및 흡습 문제를 개선시키고 유전율을 감소시킬 수 있는 것을 알 수 있었다.

  • PDF

Development of Measuring Techniques for High Voltage Impulse and Small Signals using Pockels Cell (포켈스 소자를 이용한 고전압 임펄스 및 미소신호 측정기술 개발)

  • Hong, J.Y.;Lee, J.B.;Chang, Y.M.;Koo, J.Y.
    • Proceedings of the KIEE Conference
    • /
    • 1994.07b
    • /
    • pp.1571-1573
    • /
    • 1994
  • In order to substitute for the conventional measuring system which could bring about technical inconveiences, measuring techniques for the fast transient high voltage upto 100 kV and small signals less than 1 V are developed by use of Laser Source with Packets cell. for the former, capacitive voltage divider was specially designed for reducing the impulse voltage less than the half-wave voltage of pockets cell. For the tatter, interferometer type was employed as a mean to removing the fluctuation of Laser output intensity. And also the main beam through the Pockels cell and the reference beam from the Laser source are seperated before being detected respectively by photo diodes. And then, these two signals are amplified and compared for detecting only the small signals applied across the Pockels cell. Throughout this work, Laser-based measuring system is likely to enable us, at this moment, to detect correctly lightning impulse voltage upto 100 kV and the small signals less than 1 V upto the 2 MHz. Such a system could be employed as a possible diagnostic measuring system at the substation.

  • PDF

Measurement of Tree Growth Characteristics and Acoustics Emission Signals by Partial Discharge in XLPE (XLPE의 부분방전에 의한 트리진전 특성과 음향방출신호 측정)

  • Kim, Seung-Gyu;Lee, Sang-Woo;Lee, Kwang-Sik;Kim, Yeong-Hun;Kim, Geum-Yong;Kim, In-Sik;Kim, Lee-Koo
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.1954-1956
    • /
    • 2000
  • In this paper, when void of XLPE was existed, electrical tree was growth in branch-type, and it was growth in bush-type when void of XLPE was not existed. Moreover, charge magnitude of partial discharge by deterioration time of XLPE sample was about proportion to output voltage of AE signals. When void was existed, charge magnitude of partial discharge, the output voltage Vp-p value of AE signals were increased with increasing deterioration time. However, when void were not existed, charge magnitude of partial discharge, the output voltage Vp-p value of AE signals were increased in fast deterioration time, but it were decreasing at after in middle deterioration time. Frequency spectrum response of AE signal was about 100-250[kHz].

  • PDF

Design and Properties of the 300 W Planar Transformer (300 W급 평면 변압기의 설계 및 분석)

  • Lee, Hae-Yon;Heo, Jeong-Seob;Kim, Hyun-Sik;Kim, Jong-Ryung;Oh, Young-Woo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.05a
    • /
    • pp.46-49
    • /
    • 2003
  • 전원장치의 소형 경량화 및 고효율화를 위한 핵심 기술인 변압기를 설계 및 제조하기 위해 넓은 유효단면적을 가진 평면 자성체와 편편하고 넓은 도체를 이용하여 고주파 손실을 감소시켜 고주파 대역용 전원장치에 채용 가능한 입력 220 V, 출력 15V, 300 W급 포워드(Forward) 평면 변압기를 설계 및 제조하고 전자기적 특성과 입출력 신호 특성을 측정하였다. 1차 코일과 2차 코일의 권선수는 각각 15회와 2회 그리고 여자(demagnetizing) 권선은 15회로 설계하였으며, 변압기의 총 발열은 $44.78^{\circ}C$로 설계 및 제작하였다. 스위칭 주파수 100kHz에서 1.65mH의 인덕턴스 값을 얻었으며, 100 V의 입력전압에 대하여 13 V의 안정한 구형 출력파형을 얻었다. 따라서 스위칭 듀티(duty)가 최고 0.4로 설계되었기 때문에 설계 목표한 15 V 출력에 유사한 전압을 나타내어 평면 변압기의 설계 방법을 확립하였으며, 평면 변압기의 응용 가능성을 확인할 수 있었다.

  • PDF

Robot Mobile Control Technology Using Robot Arm as Haptic Interface (로봇의 팔을 햅틱 인터페이스로 사용하여 로봇의 이동을 제어하는 기술)

  • Jung, Yu Chul;Lee, Seongsoo
    • Journal of IKEEE
    • /
    • v.17 no.1
    • /
    • pp.44-50
    • /
    • 2013
  • This paper proposed the implementation of haptic-based robot which is following a human by using fundamental sensors on robot arms without additional sensors. Joints in the robot arms have several motors, and their angles can be read out by these motors when a human pushes or pulls the robot arms. So these arms can be used as haptic sensors. The implemented robot follows a human by interacting with robot arms and human hands, as a human follows a human by hands.

Development of PLC Device for White Goods based on Web Technology (Web 기반의 백색 가전기기의 전력선 통신 장치 개발)

  • Myoung, Kwan-Joo;Kim, Dong-Sung;Cho, Sung-Guk;Kwon, Wook-Hyun;Kim, Yo-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2001.07d
    • /
    • pp.2646-2648
    • /
    • 2001
  • In this paper, the development of Power Line Communication(PLC) device for white goods is presented. The commercial PLC chip-set is used for the modem device of white goods. As a PLC device for white goods, an ARM720 u-controller and a windows CE 3.0 are adopted. UPnP (Universal Plug and Play) that is applied for home network middle ware in implemented system. In addition, application programming and emulator for home appliance are implemented using UPnP standard ver 1.0.

  • PDF

Measurement of Basis Signal with HFCT for Diagnosing Partial Discharge in Middle Joint Box of 154kV Grade (154kV급 중간접속부내의 부분방전 진단을 위한 HFCT 적용 기준신호 측정)

  • Ahn, Jong-Hyun;Yun, Ju-Ho;Choi, Yong-Sung;Park, Dae-Hee;Lee, Kyung-Sup
    • Proceedings of the KIEE Conference
    • /
    • 2007.04b
    • /
    • pp.75-78
    • /
    • 2007
  • To detect partial discharge of 154kV joint box, we have made experiment by using the HFCT sensor. Generally the signals which are detected in partial discharge test of underground power transmission cable are accompanied with both noises of high voltage and noises of surrounding power cable. The most noise in near to end part of joint box is corona, beside other noises flowed from surrounding area. Partial discharge test is difficulty due to these noises. First, we test reliability on both injection of calibration signal in NJB and removal of low frequency. After that, we had analyzed frequencies by measuring signals in IJB with 300[m] distance from NJB. Also we had measured S/N ratio by using the indirected injection method of calibration signal in IJB. In this experiment, two measurement methods were difference of detection acquisition, but these had the equal frequency properties.

  • PDF