• Title/Summary/Keyword: 전기비저항 배열

Search Result 113, Processing Time 0.035 seconds

The Crosshole Resistivity Method Using the Mixed Array (혼합배열을 사용하는 시추공간 전기비저항 탐사)

  • Cho In-Ky;Han Sung-Hoon;Kim Ki-Ju
    • Geophysics and Geophysical Exploration
    • /
    • v.5 no.4
    • /
    • pp.250-256
    • /
    • 2002
  • Resistivity tomography has become an important tool to image underground resistivity distribution. This method has been widely applied to site investigation for engineering and environmental purpose. In resistivity tomography, various electrode arrays can be used and each array has both merits and demerits. For example, the pole-pole array has high signal to noise ratio (S/N ratio), but its resolution is too low. The dipole-dipole array has low S/N ratio, but its resolution is very high. The Pole-dipole may has intermediate Snf ratio and resolution. The modified Pole-dipole array, recently proposed, shows reasonable S/N ratio and resolution, which are comparable to the pole-dipole array. These electrode arrays except the pole-pole array, however, have the problem that the apparent resistivity can diverge at some special electrode Positions. Also, the Pole-Pole array may not reflect the doe resistivity of an anomalous body. In this study, we propose a new electrode array, mixed array, where pole-dipole and modified pole-dipole ways are selectively used with the relative positions of current and potential electrodes. The mixed array has the same level of S/N ratio and resolution as the pole-dipole array and the apparent resistivity does not diverge in the receiver hole. Furthermore, the apparent resistivity using the array can reflect the true resistivity of the anomalous body.

A problem in the cross-hole resistivity method using pole-pole array (단극배열을 이용한 시추공-시추공 전기비저항 탐사법의 문제점)

  • Jo, In Gi;Choe, Gyeong Hwa
    • Journal of the Korean Geophysical Society
    • /
    • v.1 no.1
    • /
    • pp.51-58
    • /
    • 1998
  • A numerical program has been developed to model 2-D resistivity responses for a pole-pole array configuration in cross-hole resistivity measurements. Apparent resistivity and secondary potential were computed using the program for a cylindrical inhomogeneity in an uniform host medium excited by a point source of current in a borehole. Surprisingly apparent resistivity in the receiver hole turns out to be lower than the one of surrounding medium regardless of the conductivity of cylindrical inhomogeneity. Using only cross-hole data, therefore, it is impossible to interpret the conductivity of inhomogeneity. To overcome this problem, 3-D measurement and interpretation are necessary. If 3-D data acquisition is impossible, inline data should be used to get the information about the conductivity of inhomogeneity.

  • PDF

Behavior of Normalized Voltage Curves in the Resistivity Method (전기비저항 탐사에서 전위감쇠곡선의 거동특성)

  • Cho, In-Ky;Lee, Keun-Soo
    • Geophysics and Geophysical Exploration
    • /
    • v.13 no.4
    • /
    • pp.364-369
    • /
    • 2010
  • Resistivity data should be edited before the inversion because resistivity data are contaminated by a lot of noise. Generally, outlier or data violating pants-leg effect in dipole-dipole array were used to be rejected in the apparent resistivity pseudo-section. For more precise data editing, normalized voltage curves are used. In this study, we analyzed the behavior of normalized voltage curves for pole-pole, pole-dipole and dipole-dipole arrays in the presence of threedimensional inhomogeneities, and finally re-examined the validity of normalized voltage curves in the editing process of resistivity data.

낙동강변 충적층 시추자료와 지구물리탐사자료의 연관성

  • Ham, Se-Yeong;Hwang, Hak-Su;Kim, Hyeong-Su;Jeong, Jae-Yeol;Moon, Chang-Gyu;Cha, Yong-Hun;Jang, Seong
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2003.09a
    • /
    • pp.552-556
    • /
    • 2003
  • 창원시 대산면 갈전리의 강변여과수 취수지역의 8개의 시추공의 시추지료로부터 파악된 지하지질과 물리탐사자료를 비교하여 둘 간의 연관성을 검토하였다. 본 연구에서는 이미 얻어진 시추공 자료와 비교ㆍ검토하기 위하여 지구물리탐사를 실시하였다. 수행된 지구물리탐사는 쌍극자배열 전기비저항 수평탐사, 슐럼버져법배열 전기비저항 수직탐사, 지하투과레이다탐사이다. 전기비저항 수평탐사에 의하면 저비저항치의 두께는 낙동강변에 가까울수록 두꺼워지는 경향성을 보이고 있다. 전기비저항 수직탐사 결과는 시추자료와 비교적 잘 일치하고 있으며 지표로부터 세립질 모래층, 중립질 모래층, 세립질 모래층의 구분이 수직탐사 결과에서 잘 나타나고 있다. 또한 GPR탐사와 전기비저항 수직탐사 결과에 의하면, 지하수면은 6m 부근에 위치하고 있음을 알 수 있다.

  • PDF

Modified Electrical Resistivity Survey for Leakage Detection of a Waterside Concrete Barrage (콘크리트 수변구조물의 누수 탐지를 위한 변형된 전기비저항 탐사 연구)

  • Lee, Bomi;Oh, Seokhoon;Im, Eunsang
    • Geophysics and Geophysical Exploration
    • /
    • v.18 no.3
    • /
    • pp.115-124
    • /
    • 2015
  • A modified electrical resistivity survey has been suggested and applied to a leakage detection problem of concrete barrage. We suggest the modified electrical resistivity methods using electrodes floating on the water and apply line current sources instead of conventional point current sources in order to facilitate simple analysis. In addition, the study introduced the following three variations of modified electrode array: Direct potential array, Parallel potential array and Cross potential array. These arrays were tested and investigated through numerical experiment, physical model experiment and geophysical field exploration in order to verify their applicability to the water leakage detection of a concrete barrage. When water leakage occurred, all kind of array operations demonstrated distinct changes of aspects of potential difference in graphs obtained by not only the numerical and physical model experiments but also geophysical field exploration. Therefore, this modified electrode arrays of electrical resistivity survey, which has been adapted to the concrete barrage, has been found to be a useful method to detect water leakage.

Capacitively-coupled Resistivity Method - Applicability and Limitation (비접지식 전기비저항 탐사 - 적용성과 한계)

  • Lee Seong Kon;Cho Seong-Jun;Song Yoonho;Chung Seung-Hwan
    • Geophysics and Geophysical Exploration
    • /
    • v.5 no.1
    • /
    • pp.23-32
    • /
    • 2002
  • Capacitively-coupled resistivity (CCR) system is known to be very useful where galvanic contact to earth is impossible, such as the area covered with thick ice, snow, concrete or asphalt. This system injects current non-galvanically, i.e., capacitively to earth through line antenna and measures potential difference in a same manner. We derived geometric factor for two types of antenna configuration and presented the method of processing and converting the data obtained with CCR system suitable to conventional resistivity inversion analysis. The CCR system, however, has limitations on use at conductive area or electrically noisy area since it is very difficult to inject sufficient current to earth with this system as with conventional resistivity system. This causes low SM ratio when acquiring data with CCR system and great care must be taken in acquiring data with this system. Additionally the uniform contact between line antennas and earth is also crucial factor to obtain good S/N ratio data. The CCR method, however, enables one to perform continuous profiling over a survey line by dragging entire system and thus will be useful in rapid investigation of conductivity distribution in shallow subsurface.

A Study on the Modified Electrode Arrays in Two-Dimensional Resistivity Survey (2차원 전기비저항 탐사를 위한 변형된 전극배열법에 관한 연구)

  • Kim Jung-Ho;Yi Myeong-Jong;Song Yoonho;Chung Seung-Hwan
    • Geophysics and Geophysical Exploration
    • /
    • v.4 no.3
    • /
    • pp.59-69
    • /
    • 2001
  • Five kinds of modified electrode arrays were proposed to overcome the weak points of the commonly used arrays using dipole and/or pole in two-dimensional resistivity surveys. The modified pole-pole array was suggested to overcome the inefficiency caused by distant earthing in pole-pole array. Four kinds of modified arrays using dipole were designed to enhance the signal-to-noise ratio of the conventional dipole-dipole and pole-dipole arrays through boosting up the measured potential difference. In the numerical experiments using the two-dimensional modeling and inversion, the effects of the ambient electrical noise and the resolving power were examined and the results showed the validity of the modified arrays proposed in this study.

  • PDF