Kim, Dong-Woo;Lee, Ki-Yeon;Moon, Hyun-Wook;Kim, Hyang-Kon;Cho, Chung-Seog
Fire Science and Engineering
/
v.22
no.4
/
pp.54-60
/
2008
In this study, damage characteristics of MCCB and terminal block due to poor contact were analyzed, and various poor contact detection techniques were suggested. Firstly, the detection techniques using thermocouple and infrared thermal camera were analyzed respectively. Also, thermo-cap during poor contact detected abnormal status effectively by changing its color, and the detection system using an odor detector and odor capsules was analyzed. Lastly, poor contact detection screw was made using characteristics of fusible alloy, and we applied the poor contact detection screw to terminal block. The above methods could prevent electrical fire caused by poor contact effectively if they are used properly.
Kim, Koung-Hwan;Jeon, Yu-Jae;Kim, Do-Sok;Jo, Il-Jea;Shin, Young-Eui
한국태양에너지학회:학술대회논문집
/
2012.03a
/
pp.177-181
/
2012
본 연구는 고온고습 시험을 통하여 Cell 레벨에서의 표면관찰 및 효율저하를 분석하였다. 고온고습 시험 조건은 KS C IEC-61215에서 제시한 PV module하의 조건을 이용하여 온도 $85^{\circ}C$, 습도 85% 조건하에 1000시간 동안 수행하였다. 고온고습 시험에 따라 효율에 직접적인 영향을 줄 수 있는 이상 유 무를 Cell 표면을 통해 분석한 결과, 고온고습 시험 수행 중 부분적으로 변색되는 것을 확인하였다. 고온고습 시험 전 단결정 Cell의 효율은 17.74% 였으며, 1000시간 수행 후 15.63%으로 11.89%의 감소율을 보였다. 다결정 Cell의 시험 전 효율은 15.46%, 1000시간 수행 후 효율은 14.02%로 9.31%의 감소율을 보였다. 경년 시 나타나는 전기적 특성을 분석하기 위해 FF(Fill Factor)값을 분석한 결과, 고온고습 시험 전 단결정 Cell은 78.71%에서 75.01%로 4.7%의 감소율을 보였으며, 다결정 Cell은 78.10 %에서 76.66%로 1.84%의 감소율을 보였다. 효율 및 FF값에서 단결정 Cell이 다결정 Cell보다 감소율이 큰 것으로 분석되었으며, 이는 단결정 Cell이 외부 환경에서 더욱 크게 작용하여 효율저하에 영향을 주었다고 판단된다.
Park, Bo-Seong;Kim, Hyun-Jeong;Shin, Hyeonho;Park, Seongmin;Lee, Jaeun;Jeon, Sunggun;Nah, Yoon-Chae
Korean Journal of Materials Research
/
v.31
no.3
/
pp.132-138
/
2021
Electrochromic devices (ECDs) have been drawing great attention due to their high color contrast, low power consumption, and memory effect, and can be used in smart windows, automatic dimming mirrors, and information display devices. As with other electronic devices such as LEDs (light emitting diodes), solar cells, and transistors, the mechanical flexibility of ECDs is one of the most important issue for their potential applications. In this paper, we report on flexible ECDs (f-ECDs) fabricated using an all-in-one EC gel, which is a mixture of electrolyte and EC material. The f-ECDs are compared with rigid ECDs (r-ECDs) on ITO glass substrate in terms of color contrast, coloration efficiency, and switching speed. It is confirmed that the f-ECDs embedding all-in-one gel show strong blue absorption and have competitive EC performance. Repetitive bending tests show a degradation of electrochromic performance, which must be improved using an optimized device fabrication process.
The chemical and optical absorption spectroscopic characters of pink and colorless tourmalines from San Diego mine in California, U.S.A., blue/green tourmalines from anonymous mine, Brazil, and brownis black tourmalines from Uncheon and Haksan mines in Korea have been studied using X-ray diffractometer, electron microprobe, optical absorption spectroscopy, and heat treatment. Least-squares refinements give unit cell diminsions : a = 15.96-16.01 ${\AA}$, c = 7.15-7.16 ${\AA}$ for the brownish black tourmalines, a = 15.82 - 15.87 ${\AA}$, c = 7.09 - 7.10 ${\AA}$ for pink tourmalines, and a = 15.88 - 15.94 ${\AA}$, c = 7.12 - 7.15 ${\AA}$ for blue green tourmalines. The colors of tourmalines are responsible for the transition elements. The pink color is attributed to the $Mn^{3+}$ ions, the blue-green to $Fe^{2+}$ and $Mn^{2+}$, bluish green to $Cu^{2+}$, and the brownish black to $Fe^{2+}$, $Fe^{2+}$ - $Fe^{3+}$, and $Fe^{2+}$ - $Ti^{4+}$. The $Mn^{3+}$ ions of pink color tourmalines are stabilized in the Y sites compressed along the O(1)H-O(3)H axis by Jahn-Teller distortion. Heating removes the pink or red component from tourmalines, producing the colorless stones from the pink and red ones. The bluish green samples change into the greenish blue ones and a certain yellowish green samples change into the light green ones by heat treatment. In the elbaite-schorl series, the concentration of Fe and Mn are variable depending on the color zones. The green zone is characterrized by the high content of Fe and Mn are variable depending on the color zones. The green zone is characterized by the high content of Fe, whereas the pink zone by the high content of Mn. Mn increases in deep yellow zone compared with yellow or colorless zones.
This study was designed to examine the effectiveness of an unused tunnel as a rice storage place. The physicochemical changes of rice grains were investigated during 8-months of storage in the tunnel located at Kyungnam province, Korea. Two kinds of tunnel stored rices, NP(rice grown with no pesticides) and LP(rice grown with less pesticides) were compared with $5^{\circ}C$ stored rice as a control. The peroxidase activities, as an index of freshness of rice grains, gradually decreased and NP appeared to be fresher than LP. Whiteness, grain wholeness, and chalkyness were less desirable for the tunnel stored rice than the control, with no significant difference of physicochemical properties, including the broken, damaged, colored rice, and contents of moisture, protein, and amylose. Palatability dropped below 70 in all three groups at later phase. The sensory evaluation showed that overall preference was slightly higher for the control but not significantly different from the other two groups. From all the evidences shown, unused tunnels may be an effective place for a long-term rice storage, since the average temperature inside the tunnel was maintained very constantly around $14.3^{\circ}C$ and relative humidity was optimal for rice storage, especially during spring and summer seasons.
The aim of the present study is to compare the corrosion tendency using two kinds of NiTi files in the various environmental conditions through the visual examination and electrochemical analysis. ProTaper Universal S2, 21 mm (Dentsply Maillefer, Ballaigues, Switzerland) and Hero 642, 0.06 tapers, size 25, 21 mm (Micromega, Besancon, France) rotary instruments were tested. The instruments were randomly divided into eighteen groups (n = 5) by the immersion temperature, the type of solution, the brand of NiTi rotary instrument and the presence of mechanical loading. Each file was examined at various magnifications using Scanning Electron Microscope (JEOL, Akishima, Tokyo, Japan) equipped with energy dispersive X-ray microanalysis (EDX). EDX was used to determine the components of the endodontic file alloy in corroded and noncorroded areas. The corrosion resistance of unused and used NiTi files after repeated uses in the human teeth was evaluated electrochemically by potentiodynamic polarization test using a potentiostat (Applied Corrosion Monitoring, Cark-in-Cartmel, UK). Solution temperature and chloride ion concentration may affect on passivity of NiTi files. Under the conditions of this in vitro study, the corrosion resistance is slightly increased after clinical use.
An allium rhizobacterium Serratia plymuthica AL-1 was previously selected as a biocontrol agent of allium white rot. The chitinase from S. plymuthica AL-1 produced in medium containing colloidal chitin was purified by ammonium sulfate precipitation (40~70%), affinity adsorption, column chromatography on DEAE-sephadex A-50 and sephadex C-200 gel filtration. The enzyme was purified 10.8-fold with a yield of 7.3% from the starting culture broth. The purified chtinase gave a single band on sodium dodecyl sulfate polyacrylamide gel electrophoresis, it's molecular weight was estimated to be 55 kDa. The optimum pH and temperature of the purified enzyme were pH 5.5 and $55^{\circ}C$, respectively and it is stable up to $50^{\circ}C$ and maintains around 90% of its activity for 60min. The enzyme were activated by $Ca^{2+}$, $Mn^{2+}$ and $Mg^{2+}$ and inhibited by $Cu^{2+}$, SDS, $\rho$-CMB, MIA, respectively. The purified chitinase showed broad spectrum of antifungal activities against plant pathogenic fungi Sclerotium cepivoruin, Alternana alternnta, Colletotrichum glceosporioidrs, Phoma sp., Sclerotinia sclerotiorum, Stemphylium solani, Fusarium oxysporium f. sp. niveum but rarely inhibited Phytophthora capsici and Pythium ultimum.. The purified chitinase from S. plymuthica AL-1 caused swelling, lysis, deceleration and degradation of the hyphal tips of S. sczerotiorum causing allium white rot. It suggest that S. prymuthica AL-1 chitinase play an important part in the bifunctional chitinase / lysozyme activity.
In this study, The report analysed the characteristics of power drop and damage of surface in solar cell through high temperature and humidity test. The solar cells were tested during the 1000hr in $85^{\circ}C$ temperature and 85% humidity conditions, that excerpted standard of PV Module(KS C IEC-61215). An analysis of the cell surface through EL(Electroluminescence), the cell has partly change of surface in yearly. Single-crystalline Solar cell efficiency is decreased from 17.7% to 15.6% and decreasing rate is 11.9%. On the other hand, Poly-crystalline Solar cell efficiency is decreased from 15.5% to 14.0% and decreasing rate is 9.3%. A comparison of the fill factor for analysis of electro characteristic in yearly, Single-crystalline Solar cell efficiency is decreased from 78.7% to 78.1% and decreasing rate is 4.7%. On the other hand, Poly-crystalline Solar cell efficiency is decreased from 78.1% to 76.7% and decreasing rate is 1.8%. Single-crystalline has more bigger power drop than poly-crystalline by the silicon purity and silicon atom arrangement. Also, FF decreasing rate has more bigger drop than efficiency decreasing rate for the reason that the damage of surface by exterior environmental factor is the more influence in cell than other reason that is decreasing FF by damage of p-n junction.
Poly(${\varepsilon}$-caprolactone) (PCL) nanofibers and PCL/silica membranes were synthesized by sol-gel derived electrospinning and casting, respectively. Smooth PCL nanofibers were obtained from the precursor containing N,N-dimethylformamide (DMF). PCL/silica membranes were prepared by varying the tetraethyl orthosilicate (TEOS) contents from 0 to 40 vol% to investigate the effect of silica addition on mechanical properties and cytotoxicity of the membranes. Although the strength of the membranes decreased from 12 to 8 MPa with increasing the silica content, the strength remained almost constant 7 weeks after dipping in phosphate buffered saline solution (PBS). The strength reduction was attributed to the presence of a patterned surface pores and micro-pores present in the walls between pores. The crystal structure of the membranes was orthorhombic and the crystallite size decreased from 57 to 18 nm with increasing the silica content. From the agar overlay test, the PCL/silica membranes exhibited neither deformation and discoloration nor lysis of L-929 fibroblast cells.
Kim, Ji Gang;Nimitkeatkai, Hataitip;Choi, Ji Woen;Lee, Sang Gyu
Journal of Bio-Environment Control
/
v.21
no.4
/
pp.411-418
/
2012
This study was conducted to investigate the effect of calcinated calcium (CC) alone or combination with heat treatment on storage quality and microbial growth in fresh-cut broccoli. Fresh broccoli samples were cut into small pieces and washed in normal tap water (TW), $50{\mu}L{\cdot}L^{-1}$ chlorinated water (pH 6.5), $1.5g{\cdot}L^{-1}$ CC, heat treatment in TW at $45^{\circ}C$, and CC dissolved in TW at $45^{\circ}C$ for 2 minutes separately. Samples were then packaged in $50{\mu}m$ polyethylene bags and stored at $5^{\circ}C$. Results revealed that like $50{\mu}L{\cdot}L^{-1}$ chlorine, washing in CC at normal water temperature was effective in reducing microbial population in fresh-cut broccoli samples. Washing with CC combined with heat treatment increased an electrical conductivity of fresh-cut broccoli. Combined heat treatments with TW and CC reduced aerobic plate count on fresh-cut broccoli, only in initial period of storage. But, later on heat treatment induced injury of fresh-cut broccoli resulting more microbial population compared to non heat treatment. However, samples treated with CC alone had good quality with low off-odor at the end of storage. Results suggest that CC, an environment-friendly sanitizer could be an alternative to chlorinated water for washing of fresh-cut broccoli without affecting sensorial quality.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.