• Title/Summary/Keyword: 전기발생

Search Result 7,841, Processing Time 0.034 seconds

Studies on the Effects of Ozone Gas in Paddy Rice 3. Biochemical effects of ozone gas on rice plant (수도생육(水稻生育)에 대(對)한 Ozone가스의 영향(影響)에 관(關)한 연구(硏究) 3. Ozone가스에 의(依)한 수도엽의(水稻葉) 생화학적(生化學的) 변화(變化))

  • Kim, Bok-Young;Cho, Jae-Kyu;Lee, Suk-Hee
    • Korean Journal of Environmental Agriculture
    • /
    • v.5 no.2
    • /
    • pp.106-112
    • /
    • 1986
  • Biochemical and histological effects of ozone gas (0.3 ppm) on rice plant were discussed. After ozone expoure, damage symptom, percentages of destroyed leaves, activities of peroxidase and polyphenoloxidase, and the contents of flavonoid, protein and sugar were examined on two rice varieties (Seokwangbyeo, Jinjubyeo), on tillering stage, and at different exposure time (0, 1, 3, 5 hr). The result were as followed. 1. The ozone-injured cell adjoining stomata become pigmented red-brown. 2. The percentage of injured leaves in Jinjubyeo was higher than that in Seokwangbyeo. 3. The activities of peroxidase and polyphenoloxidase increased on ozone-injured leaves. 4. The peroxidase activity increased with time in Jinjubyeo compared to Seokwangbyeo. 5. Peroxidase isozyme spectrum was altered after ozone exposure. 6. The content of flavonoid and reducing sugar in the rice leaves was increased, but the contents of protein was reduced.

  • PDF

A Study on Heat Transfer Coefficient of a Perfluorocarbon Heat Pipe (Perfluorocarbon 히트파이프의 열전달 계수에 관한 연구)

  • 강환국;김철주;김재진
    • Journal of Energy Engineering
    • /
    • v.7 no.2
    • /
    • pp.194-201
    • /
    • 1998
  • In electric commuter trains using AC motors, lots of GTO thyristors and diodes are needed for power controls. These semiconductors generate heat about 1~2 kW, and for cooling which perfluorocarbon(PFC) heat pipes have been in use for the last two decades. The present study was investigated on the effects of such important design parameters as structure of internal surface (grooved or smooth), fill charge ratio, and inclinating angle from a vertical on heat transfer coefficients at both evaporators and condensers. To obtain experimental data, several heat pipes of the same geometry of 520 mm long and diameter of 15.88 mm but different in fill charge ratio and internal surface structure were designed and fabricated. For prediction of the heat transfer coefficients, related expressions were examined and the results of calculations were compared with experimental data. Performance tests were conducted while heat pipes operated at mode of thermosyphons. High enhancements of heat transfer coefficient were obtained internal grooves. In these cases, the evaporating heat transfer coefficients distributed in the range of 2~5.5 kW/$m^2$K, with an increase of heat flux from 15~45 kW/$m^2$. These experimental data were in good agreement with Rohsenow's expression based on nucleate boiling when correction factor $C_R$=1.3 was encountered. In addition, the condensation heat transfer coefficients were distributed from 1.5 to 3.5 kW/$m^2$K, and the data were in good agreements with Nusselt's correlation, based on filmwise condensation on vertical plate, when choosing a correction factor $C_N=4$. A fill charge ratio of 40~100% were recommended, and the in clination angle effects were negligible when the angle was higher then 30$^{\circ}$.

  • PDF

Design, Fabrication and Evaluation of a Conduction Cooled HTS Magnet for SMES (SMES용 전도냉각형 고온초전도 자석의 설계, 제작 및 평가)

  • Bae, Joon-Han;Kim, Hae-Jong;Seong, Ki-Chul
    • Journal of Energy Engineering
    • /
    • v.20 no.3
    • /
    • pp.185-190
    • /
    • 2011
  • This paper describes design, fabrication, and evaluation of the conduction cooled high temperature superconducting (HTS) magnet for superconducting magnetic energy storage (SMES). The HTS magnet is composed of twenty-two of double pancake coils made of 4-ply conductors that stacked two Bi-2223 multi-filamentary tapes with the reinforced brass tape. Each double pancake coil consists of two solenoid coils with an inner diameter of 500 mm, an outer diameter of 691 mm, and a height of 10 mm. The aluminum plates of 3 mm thickness were arranged between double pancake coils for the cooling of the heat due to the power dissipation in the coil. The magnet was cooled down to 5.6 K with two stage Gifford McMahon (GM) cryocoolers. The maximum temperature at the HTS magnet in discharging mode rose as the charging current increased. 1 MJ of magnetic energy was successfully stored in the HTS magnet when the charging current reached 360A without quench. In this paper, thermal and electromagnetic behaviors on the conduction cooled HTS magnet for SMES are presented and these results will be utilized in the optimal design and the stability evaluation for conduction cooled HTS magnets.

In Vivo Measurement of Extracellular Monoamines and Their Metabolites in the Rat Posterior Hypothalamus Using Microdialysis Technique (미세투석법을 이용하여 흰쥐 후 사상하부에서 세포외액의 모노아민과 대사체들의 생체내 측정)

  • Sung, Ki-Wug;Kim, Seong-Yun;Cho, Young-Jin;Lee, Kweon-Haeng;Lee, Sang-Bok
    • The Korean Journal of Pharmacology
    • /
    • v.28 no.1
    • /
    • pp.1-9
    • /
    • 1992
  • Catecholamines, serotonin and their metabolites were measured in the posterior hypothalamus of urethane-anesthetized normotensive Wistar Kyoto rats (WKY) and spontaneously hypertensive rats (SHR) using brain microdialysis which is a recently developed experimental method to measure the release of neurotransmitters and their metabolites at the localized brain area in vivo. Microdialysis probe was implanted stereotaxically to the rat posterior hypothalamus and perfused by Ringer's solution. Monoamines and their metabolites were quantified by reverse phase high performance liquid chromatography with electrochemical detection. In vitro recovery test of microdialysis showed that there exist inverse relationship between the perfusion flow rate and the relative recovery of neurochemical compounds. The estimated extracellular concentration of dopamine was about 32 nM, of norepinephrine 50 nM, of epinephrine 50 nM, of serotonin 73 nM, of 3, 4-dihydroxyphenylacetic acid (DOPAC) 281 nM, of homovanillic acid (HVA) 181 nM, and of 5-hydroxyindoleacetic acid (5HIAA) 3767 nM in the hypothalamic perfusate of the normotensive rat. There was no difference in the basal level of monoamines between the SHR and the WKY. In contrast, the level of DOPAC, HVA and 5HIAA in SHR was higher than that in the WKY, This study demonstrated that the microdialysis technique should be an applicable tool for in vivo measurement of central neurochemical substances.

  • PDF

A Study on the Examination of Explosion Hazardous Area Applying Ventilation and Dilution (환기 및 희석을 적용한 폭발위험장소 검토에 관한 연구)

  • kim, Nam Suk;Lim, Jae Geun;Woo, In Sung
    • Journal of the Korean Institute of Gas
    • /
    • v.22 no.4
    • /
    • pp.27-31
    • /
    • 2018
  • Classification of explosion hazard areas is very important in terms of cost and safety in the workplace handling flammable materials. This is because the radius of the hazardous area determines whether or not the explosion-proof equipment is installed in the electrical machinery and apparatus. From November 6, 2017, KS C IEC-60079-10-1: 2015 will be issued and applied as a new standard. It is important to understand and apply the difference between the existing standard and the new standard. Leakage coefficients and compression factors were added to the leakage calculation formula, and the formula of evaporation pool leakage, application of leakage ball size, and shape of explosion hazard area were applied. The range of the safety factor K has also been changed. Also, in the radius of the hazardous area, the existing standard applies the number of ventilation to the virtual volume, but the revised standard is calculated by using the leakage characteristic value. In this study, we investigated the differences from existing standards in terms of ventilation and dilution and examined the effect on the radius of the hazard area. Comparisons and analyzes were carried out by applying revised standards to workplaces where existing explosion hazard locations were selected. The results showed that even if the ventilation and dilution were successful, the risk radius was not substantially affected.

Effect of Major Factors on the Spray Characteristics of Ultrasonic Atomizing Nozzle (초음파 미립화 노즐의 분무 특성에 미치는 주요 인자의 영향)

  • Jeong, Seon Yong;Lee, Kye Bock
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.6
    • /
    • pp.1-7
    • /
    • 2017
  • The atomization of a liquid into multiple droplets has many important industrial applications, including the atomization of fuels in combustion processes and coating of surfaces and particles. Ultrasonic atomizing nozzle has a transducer that receives electrical input in the form of a high frequency signal from a power generator and converts that into mechanical energy at the same frequency. Liquid is atomized into a fine mist spray using high frequency sound vibrations. In coating applications, the unpressurized, low-velocity spray reduces the amount of overspray significantly because the droplets tend to settle on the substrate, rather than bouncing off it. The spray can be controlled and shaped precisely by entraining the slow-moving spray in an ancillary air stream using specialized types of spray-shaping equipment. The desired patterns of spray can be obtained using an air stream. To simulate the water mist behavior of an ultrasonic atomizing nozzle using an air stream, the Lagrangian dispersed phase model was employed using the commercial code FLUENT. The effects of the nozzle contraction shape, water droplet size and the pneumatic pressure drop on the spray characteristics were investigated to obtain the optimal condition for coating applications.

Forging Die Design for Vent Forming of Square Cup Battery Case (사각 컵 배터리 케이스 바닥 벤트 성형을 위한 단조 금형 설계)

  • Lee, Sang-Hoon;Kwon, Soon-Ho;Chung, Hoon;Hong, Seokmoo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.6
    • /
    • pp.330-335
    • /
    • 2017
  • The demand for electric motor fuel cells has surged in the automotive industry, leading to a recent increase in the demand for square aluminum cans used as fuel cell battery casings. The air vent located on the bottom of the rectangular battery casing prevents large explosions by intermittent pressure release prior to the accumulation of abnormally high pressures. Conventionally, the square cup battery casing is produced via six-step deep drawing, with the outer shape of the vent being manufactured by welding to the square battery casing. On the other hand, this study directly incorporated the air vent outlet into the bottom surface of the rectangular casing. The product of a coupled finite element analysis technique applying the thickness and contour generated from the square cup multi-step deep drawing formation analysis was used as the forging input shape. The results yielded increased prediction accuracy and the advanced prediction of defects, such as swelling and fracture. Based on the results of the initial analyses, two of the generated forging shapes were determined to be suitable, with the optimal forging shape being determined by molding analysis. The results presented here were validated by mold fabrication and a subsequent comparison of the actual and analytical results.

Effect of Pretreatment Process on Hybrid Membrane Filtration Performance (원수의 물리.화학적 특성에 따른 막 분리 공정의 전처리 공정 적용성 평가)

  • Jung, Chul-Woo;Son, Hee-Jong;Bae, Sang-Dae
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.28 no.6
    • /
    • pp.613-619
    • /
    • 2006
  • The objectives of this research are to evaluate the effect of membrane materials, particulate matter and membrane pore size on permeate flux. It was shown that the removal efficiency of high MW organic matter more than 10 kDa was lower than that of low MW organic matter for $MIEX^{(R)}$ process. For the change of permeate flux by the pretreatment process, $MIEX^{(R)}+UF$ process showed high removal efficiency of organic matter as compared with coagulation+UF processes, but high reduction rate of permeate flux was presented through the reduction of removal efficiency of high MW organic matter. The pretreatment of the raw water significantly reduced the fouling of the hydrophilic membrane, but did not decrease the flux reduction of the hydrophobic membrane. Flux decline on MF process increased due to the pore clogging, while the permeate flux decline of UF process decreased due to the formation of cake layer. It was shown that particle matter was not effect on MIEX+membrane process. But, for coagulation+membrane process, particle matter was important factor on permeate flux.

Applicability of Volatile Corrosion Inhibitor and VCI Films for Conservation of Artworks (미술작품의 보존을 위한 기화성 방청제 및 방청필름의 적용성 연구)

  • Beom, Dae Geon;Han, Ye Bin
    • Journal of Conservation Science
    • /
    • v.36 no.2
    • /
    • pp.82-92
    • /
    • 2020
  • Modern artworks are constructed using a variety of materials and techniques. Sculptures, which predominantly consist of metals, usually have different shapes and consist of different material mixtures. The structural and material properties of these sculptures are often controlled by conservation treatment methods. However, the application of existing treatment methods is challenging at times, indicating that more diverse treatment materials and techniques are necessary. Therefore, in this study, a treatment method that employs volatile corrosion inhibitor(VCI) powder, rather than an anti-corrosion solution, for the conservation and management of metal artworks was used. VCI powder and VCI films containing VCI powder were used, and the results obtained confirmed that both of them showed anti-corrosion effect. Only a slight change in the chromaticity of metal samples was observed, and compared to the untreated samples, the application of the VCI powder resulted in a decrease in the rate of corrosion by half. Moreover, VCI film tests revealed that comparing to the untreated or polyethylene film-treated samples, VCI film treatment resulted in a decrease in the occurrence of corrosion compounds. The contact angle, surface energy, and surface electrical resistance were measured, and the evaluation of these surface properties established the anti-corrosion effect of VCI. Additionally, direct application of VCI and VCI films on actual sculptures further confirmed the anti-corrosion effect of VCI.

Analysis of relative displacement of electromagnetic suspension using CARSIM and Simulink (CARSIM- Simulink연동 해석을 이용한 전자기 현가장치의 상대변위 해석)

  • Kim, Ji-Hye;Kim, Jin-Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.5
    • /
    • pp.82-88
    • /
    • 2018
  • This study investigated the structure of an 8-pole 8-slot linear generator, which acts as an electromagnetic damper by combining the structure of an electromagnetic suspension device capable of generating electrical energy through energy harvesting by absorbing the vibration energy from the road surface while driving. To compare the energy harvesting effect of the electromagnetic suspension according to the actual road surface, a driving road test was simulated for two actual road conditions, an asphalt road surface and unpacked road surface condition, using a civilian combined vehicle model in conjunction with a vehicle simulation program, Carsim and Simulink. As a result, the relative displacements of the suspensions on the asphalt road surface and the unpaved road were 8 mm and 13 mm, respectively. By applying the suspension displacement value derived by modeling the linear generator coupled to the electromagnetic suspension, the simulation was then performed for an analysis time of 0.3s by applying the same analytical conditions using the commercial electromagnetic analysis program, ANSYS MAXWELL, The average power generation on the unpacked roads and asphalt roads was 198.6W and 98.7W respectively, which was 103.7% higher for unpackaged roads. Finally, to compare the sensitivity of the road surface frequency and the suspension input displacement to the power generation output, the sensitivity of the two variables was 1.725 and 1.283, respectively, and the road surface frequency had a 34.5% higher effect on the average power generation.