• Title/Summary/Keyword: 전기강판

Search Result 189, Processing Time 0.026 seconds

Development and Application of Anti-Corrosive Steel Using Electro-Deposition of Sea Water (1) -Development of Electro-Deposition System Using Sea Water (해수전착 코팅을 이용한 내부식성 철근의 개발 및 적용성에 대한 연구 (1) -해수전착 코팅 시스템 개발)

  • Kwon, Seung Jun;Lee, Myeong Hoon;Park, Sang Soon
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.16 no.5
    • /
    • pp.78-87
    • /
    • 2012
  • This study is for developing a system for electro-deposition utilizing sea water containing various ions like calcium and magnesium. This is the first step research for the final goal which is a development of anti-corrosive steel for RC structure, so that this paper is mainly focused on the development for electro-deposition system. Optimum conditions for steel coating is obtained through various tests considering anode type, temperature, duration time, and current density. The composition of electro-deposition is analyzed through SEM, EDS, and XRD and it is evaluated to be $CaCO_3$ and $Mg(OH)_2$. Through measuring polarization potential and current density in the coated steel, the coating layer from the developed system is evaluated to have high resistance to steel corrosion. Additional tests and discussions on durability and structural performance in the coated steel from this work will be performed for the second step research.

Vibration Analysis of Symmetrically Laminated Composite Rectangular Plates (대칭 복합적층 직사각형 판의 진동해석)

  • T.Y. Chung;J.H. Chung
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.29 no.3
    • /
    • pp.140-148
    • /
    • 1992
  • The free vibration problem of symmetrically laminated composite rectangular plates is formulated based on anisotropic thick plate theory including the effects of shear deformation and rotary inertia. Considering the difficulty of obtaining closed-form solutions, Rayleigh-Ritz analysis using polynomials having the property of Timoshenko beam functions as trial functions is adopted. The boundary conditions elastically restrained against rotation are accomodated as well as classical boundary conditions. From the results of numerical studies, the validity of the present method is verified. And it is also found that the adoption of thick plate theory for the vibration analysis of laminated composite plates is essential because of the relatively large shear deformation effect, and that the convergence of the Rayleigh quotient to the stationary value is less rapid in anisotropic composite plates than that in the orthotropic ones due to more complicated mode shapes of the former.

  • PDF

A Comparative Study of Single-Phase AC and Inverter DC on Electrode Life for Resistance Spot Welded Electrogalvanized Steel Sheets (전기아연 도금 TRIP강판의 저항 점용접 시 연속타점 수명에 미치는 단상 AC와 인버터 DC의 비교 연구)

  • Son, Jong Woo;Park, Yeong-Do;Kang, Mun Jin;Kim, Dong Cheol
    • Korean Journal of Metals and Materials
    • /
    • v.47 no.12
    • /
    • pp.834-841
    • /
    • 2009
  • A study on the welding of electrogalvanized TRIP (Transformation-Induced Plasticity) steels was done to compare the life of the electrode and the alloying phenomena on the electrode tip surface using singlephase AC and inverter-DC resistance welding processes. A longer life of the electrode (>200 welds) was achieved using the inverter-DC welding process. The tensile shear strength was higher in the electrode life test when welded with the inverter DC welding machine it maintained a higher value even when the welding nugget diameter was smaller than specified. When spot-welding was conducted using the single-phase AC welding process, a higher wear rate of the electrode was observed compared to that with the inverter-DC process. An alloying layer used to determine the rate of electrode growth showed differences in the metallurgical features of the surface alloying and Zn penetration depending on whether the single-phase AC process or the inverter-DC welding process was used. Moreover, changes in the dynamic resistance during the electrode life test were correlated with the electrode wear (or growth) rate.

Study on the Room Temperature Degreasing Conditions of Steel Sheet for Electrogalvanizing (전기아연도금용 강판의 상온 탈지 조건 연구)

  • Tae-Yeon Park;Chae-Won Kim;Su-Mi Yang;Hee-Jun Hong;In-Chul Choi
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.37 no.1
    • /
    • pp.16-22
    • /
    • 2024
  • The conventional degreasing process involves removing oil and contaminants at temperatures above 80℃, resulting in excessive energy consumption, increased process costs, and environmental issues. In this study, we aimed to find the optimal degreasing conditions for the pre-treatment process of electro-galvanizing cold-rolled steel sheets, conducted efficiently at room temperature without the need for a separate heating device. To achieve this, we developed a room temperature degreasing solution and a brush-type degreasing tool, aiming to reduce energy consumption and normalize the decrease in degreasing efficiency caused by temperature reduction. Alkaline degreasing solution were prepared using KOH, SiO2, NaOH, Na2CO3, and Sodium Lauryl Sulfate, with KOH and NaOH as the main components. To enhance the degreasing performance at room temperature, we manufactured additives including sodium oleate, sodium stearate, sodium palmitate, sodium lauryl sulfate, ammonium lauryl sulfate, silicone emulsion, and EDTA-Na. Room temperature additives were added to the alkaline degreasing solution in quantities ranging from 0.1 to 20 wt.%, and the uniformity of degreasing and the adhesion of the galvanized layer were evaluated through Dyne Test, T-bending Test, OM, SEM, and EDS analyses. The results indicated that the optimal degreasing solution composition consisted of NaOH (30 g/L), Na2CO3 (30 g/L), SLS (6 g/L), and room temperature additives (≤1 wt%).

Measurement of Al Concentration in Liquid Zinc by E.M.F Method with $CaF_2$ ($CaF_2$ 기전력법에 의한 용융아연 중 알루미늄 농도의 측정)

  • Park Jin Sung;Kim Hang Soo;Jung Woo-Gwang;Katayama I.;Kim Jong Sang
    • Journal of the Korean Electrochemical Society
    • /
    • v.3 no.4
    • /
    • pp.204-210
    • /
    • 2000
  • The control of dissolved aluminum concentration in the hot dip zinc galvanizing bath is greatly important in producing galvannealed steel sheets. The purpose of present study is to provide basic data for measurement of the aluminum concentration in site in hot dip zinc bath at the temperature of $460^{\circ}C\~500^{\circ}C$ using $CaF_2$ solid electrolyte sensor with three kinds of reference electrode. Good workability and stability of the sensor were confirmed with the $Bi+BiF_3$ reference electrode from the emf measurement. In order to measure the aluminum concentration in Zn-Al bath, the galvanic cell of fluorine ion was constructed with $CaF_2$ solid electrolyte as follows; $$(-)W|Zn-Al,\;AlF_3|CaF_2|Bi,BiF_3|W(+)$$. The emf measurement was made at the temperature of $460\pm10^{\circ}C$ in the Zn-Al bath. The following correlationship between aluminum concentration and emf was obtained by the least square regression analysis; $$E/mV=56.795log[\%Al]+1881.7\;R=0.9704$$,$$0.026wt\%{\leq}[\%Al]{\leq}0.984wt\%$$

Survey on Housing Types of Korean Native Cattle and Beef Cattle by Farm Scale and Region (한우농가의 사육규모별, 지역별 축사시설 현황 분석)

  • Choi, H.C.;Kham, Dong-Hwan;Song, J.I.;Jeon, B.S.;Jeon, J.H.;Yoo, Y.H.;Na, J.C.;Yu, D.J.;Bang, H.T.;Suh, O.S.;Lee, S.C.;Kim, J.S.;Lee, D.H.
    • Journal of Animal Environmental Science
    • /
    • v.14 no.3
    • /
    • pp.167-174
    • /
    • 2008
  • This survey was conducted to investigate housing types of Korean native cattle and beef cattle farms in Korea. The farm sized over 50 heads of cattle, 7,433 farms were surveyed. Regarding housing types for Korean native cattle and beef cattle, litter barn, freestall, mooring+litter ground and others accounted for 87.1, 9.8, 3.0, and 2.9 %, respectively. Most of Korean native cattle and beef cattle farms (94.7%) used litter floor rather than scraper. As for roof types, slate, panel, iron plate, galvanized plate, colored iron plate and sunlight represented 32.2, 13.7, 12.2, 10.2, 9.7, and 8.9 %, respectively. Open side wall type and winch curtain were 55.6, and 47.6 %, respectively. Bigger farms seemed to used more winch curtain than open style. Utilization period of automatic feeder, waterer, electric facility, and cooling facility was 6.7, 8.0, 8.5, and 6.0 years, respectively.

  • PDF

Degradation evaluation of paint films on surface treated steel by electrochemical impedance spectroscopy (전기화학적 임피던스 분광법에 의한 표면처리한 강재 도장의 부식-도막 열화도 평가)

  • Park, Jun-Mu;Park, Jae-Hyeok;Kim, Sun-Ho;U, Sang-Gyun;Gwon, Yong-Min;Mun, Gyeong-Man;Lee, Myeong-Hun
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2018.06a
    • /
    • pp.95-95
    • /
    • 2018
  • 강재의 방식법 중 도장은 부식을 억제하는데 효과적이고 편리한 방법으로 선박 및 해양 강 구조물의 방식법으로 사용되고 있다. 한편, 강 구조물의 효율적인 유지관리를 위해서는 방식 도장의 도막 열화도를 평가하고 잔존 수명을 예측하여 최적 시기에 보수도장 혹은 재도장하는 것이 필요하다. 일반적으로 선박 및 해양구조물에 적용되는 도막의 방식 성능 평가 방법으로 해수 침지 시험, 염수 분무 시험, 옥외 폭로 시험 등이 있다. 그러나 이러한 시험들은 그 시험 방법에 따라서 정량적인 평가에 한계가 있음은 물론 장기간 소요되는 등 곤란한 문제점이 있다. 그러므로 선박 및 해양구조물을 비롯하여 교량, 각종 강 구조물의 도장 방식에 사용되는 방식용 도료의 성능을 단기간에 적절하게 평가할 수 있는 가속시험법이 제시되며 연구-사용되고 있다. 그 중 도막 방식 성능을 보다 효율적, 비파괴적, 정량적으로 평가할 수 있는 임피던스 분광법(EIS)과 같은 전기화학적 방법은 상대적으로 시험 기간을 크게 단축시킬 수 있고, 대상 방식 도장의 미세한 성능 차이도 분별 가능하다는 장점이 있다[1]. 따라서 본 연구에서는 선박 및 해양구조물 등 가혹한 부식환경에서 강력한 내구성을 가질 수 있도록 다양한 종류의 표면처리 도장 시편을 제작하여 자외선 조사-염수분무-침지환경 등의 열악한 환경조건 하에서 부식-열화 촉진 시험을 실시하였다. 그리고 그 촉진 열화 과정에서 도막의 외관 상태를 관찰 분석함은 물론 전기화학적 임피던스 분광법을 병행 측정하며 그 표면막의 부식 및 도막 열화도를 비교-종합 평가하였다.본 연구에 사용된 시편은 Al 및 Zn 도금 강판에 에폭시, 에폭시-실리콘 우레탄, 에폭시-우레탄 도장 시편으로 Scribe, No Scribe 및 비교재 Al 및 Zn 도금 시편으로 분류하여 각각 실험을 진행하였다. 즉, 도막 열화 시험은 복합 노화 시험법으로 UV 조사 36 시간(ASTM G53), 염수분무 32 시간(ISO 7253), 수분 응축 10 시간을 1 Cycle로 100 Cycle(7800 시간) 동안 실험을 진행하였다. 이때 도막 열화도 평가는 전기화학적 임피던스 분광법을 이용하여 각 실험 조건별로 주파수에 따른 임피던스(Z) 값을 평가하였다. 즉, 상온 $25^{\circ}C$의 3.5% NaCl 100 ml 수용액에 작동 전극(Working Electrode)과 구리 도선을 통해 연결하였고, 노출 면적은 $1cm^2$로 일정하게 유지 하였으며, 상대 전극(Counter Electrode)은 탄소봉, 기준 전극(Reference Electrode)으로 포화카로멜전극(Saturated Calomel Electrode)을 사용하여 측정하였다. No Scribe 시편의 경우에는 Al 기판 에폭시-실리콘 우레탄 도장 시편이 우수한 도막 저항성을 나타내었으며, 에폭시-우레탄 도장시편은 23사이클 이후의 저항값이 가장 낮게 나타났다. Zn 기판의 경우는 에폭시, 에폭시-실리콘 우레탄, 에폭시-우레탄 도장 시편 모두 저항 값이 유사하였으며, Al 및 Zn 도금 시편은 도장 처리된 시편에 비해 훨씬 낮은 저항 값을 보였다. 또한 Scribe 시편의 경우에는 Al 기판 에폭시-실리콘 우레탄 도장 시편에서 높은 초기 저항 값을 보였으며, 23 사이클 후의 저항 값은 세 종류의 도막에서 약 1~0.1 Gohm 으로 나타났다. 그리고 Zn 기판 에폭시-실리콘 우레탄 도장 시편에서 가장 낮은 도막 저항 값이 나타났다. 이상의 실험을 통해서 본 연구 내용은 실내촉진시험으로 선박 및 해양 강 구조물에 사용되는 다양한 종류의 도막의 열화도를 평가하는 기초 설계 지침으로 응용될 수 있을 것으로 사료된다. 한편, 도막은 노출 환경에 따라 방식 성능이 다르므로 실제 도막의 사용환경을 고려하여 도장 사양별 적용 부위에 따른 적정 가속 실험 방법을 선정할 필요가 있다고 사료된다.

  • PDF

A Study on the Prediction of Nugget Diameter of Resistance Spot Welded Part of 1.2GPa Ultra High Strength TRIP Steel for Vehicle (차체용 1.2GPa급 초고장력 TRIP강판의 저항 점 용접부 너겟 지름 예측에 관한 연구)

  • Shin, Seok-Woo;Lee, Jong-Hun;Park, Sang-Heup
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.3
    • /
    • pp.52-60
    • /
    • 2018
  • In the automobile industry, in order to increase the fuel efficiency and conform to the safety regulations, it is necessary to make the vehicles as light as possible. Therefore, it is crucial to manufacture dual phase steels, complex phases steels, MS steels, TRIP steels, and TWIP from high strength steels with a tensile strength of 700Mpa or more. In order to apply ultra-high tensile strength steel to the body, the welding process is essential. Resistance spot welding, which is advantageous in terms of its cost, is used in more than 80% of cases in body welding. It is generally accepted that ultra-high tensile strength steel has poor weldability, because its alloy element content is increased to improve its strength. In the case of the resistance spot welding of ultra-high tensile steel, it has been reported that the proper welding condition area is reduced and interfacial fracture and partial interfacial fracture occur in the weld zone. Therefore, research into the welding quality judgment that can predict the defect and quality in real time is being actively conducted. In this study, the dynamic resistance of the weld was monitored using the secondary circuit process variables detected during resistance spot welding, and the factors necessary for the determination of the welding quality were extracted from the dynamic resistance pattern. The correlations between the extracted factors and the weld quality were analyzed and a regression analysis was carried out using highly correlated pendulums. Based on this research, a regression model that can be applied to the field was proposed.

Surveying for Barn Facilities of Dairy Cattle Farms by Holding Scale (젖소농가의 사육규모별 축사시설 분석)

  • Min, B.R.;Seo, K.W.;Choi, H.C.;Lee, D.W.
    • Journal of Animal Environmental Science
    • /
    • v.15 no.3
    • /
    • pp.251-262
    • /
    • 2009
  • In this research dairy cattle barn facilities what are 4,198 houses hold over 50 heads were surveyed by scale and province. Full-time farms hold over 50 heads breed total 344,514 heads. Each of Farms holds 50 to 99 heads were 79.8 percent and breed average 82.1 heads. Dairy cattle barns were constructed september 1995 averagely. Each of barns have $1,740.0\;m^2$ scale. The construction type of dairy cattle barn was almost litter barn type 84.0%, freestyle type 5.1%, mooring+litter ground type 17.3% and other types 4.4%. The litter barn type was popular in small farms. But in large farms, freestyle type was popular than small farms. The construction type of dairy cattle barn was almost litter barn type 84.0%, freestyle type 5.1%, moohng+ltter ground type 17.3% and other types 4.4%. Type of dairy cattle robotic milking system was pipeline 41.5%, herringbone 22.8% and tandem 35.8%. The pipeline type was popular in small farms which have 50~99 heads. But in large farms which have over 200 heads, tandem type was popular than small farms. Proportion of floor type of dairy cattle barn was almost litter type 94.9%. Scraper type was popular in large farms than in small farms. Proportion of roof type of dairy cattle barn was slate 32.5%, vinyl 16.3%, sunlight 11.1%, panel 10.9, zinc plate 8.8 and steel plate 8.3%. Roof type was lots of slate type before 1995. But vinyl type is increasing after 1995. Proportion of wall type of dairy cattle barn was almost open type 83.3% and winch-curtain 26.8%. Utilization period of dairy cattle barn was 9.2 years about milker, 7.9 years about automatic feeder, 9.2 years about waterer and 10.4 years about electric facilities. In this results, there were lots of improvements about automatic feeder.

  • PDF