• Title/Summary/Keyword: 전극 크기

Search Result 590, Processing Time 0.018 seconds

Crack Detection of Carbon Fiber Reinforced Composites by Electric Potential Method with Bridge Circuit Concept (브리지 회로 개념이 적용된 전기 전위법을 이용한 탄소섬유복합재료의 균열검출)

  • Hwang, Hui-Yun
    • Composites Research
    • /
    • v.22 no.1
    • /
    • pp.9-14
    • /
    • 2009
  • This paper suggested the electric potential method with a bridge circuit concept for the detection of the location and crack growth of carbon fiber reinforced composites to reduce the measurement numbers. 2 pairs of electrodes were fabricated on the center cracked thin composite plates, and potential changes at one pair of adjacent electrodes were observed while external voltage input was applied to the other pair of adjacent electrodes. The effects of the size and interval of electrodes, location and propagating direction of center cracks were investigated by experiments and finite element analyses. Detectable crack size was influenced by the electrode interval rather than the electrode size, and crack detection was enhanced as the size and interval of electrodes were smaller. Besides, output potential changes were larger as the crack grew and was nearer the voltage input electrodes.

Thermal Distribution in a Phantom Using 8MHz RF Capacitive Type Hyperthermia (8 MHz 고주파 유전형 가열장치로 가열한 모형에서의 열분포)

  • Lee Jong Young;Park Kyung Ran;Kim Kye Jun;Sung Ki Joon
    • Radiation Oncology Journal
    • /
    • v.9 no.2
    • /
    • pp.171-176
    • /
    • 1991
  • To evaluate the temperature distribution according to the size of the electorde and the thickness of the phantom using 8MHz radiofrequency capacitive heating device, various sized electrodes and phantoms were used in combination. The radii of the electrodes are 10, 15, 20, 25, and 30 cm and the thickness of cylindrical phantoms with diameter 30 cm were 10, 15, 20, 25, 30, and 35 cm. When the thickness of the phantom was 25 cm or 30 cm, homogenous heating was achieved by using the electrode which diameter was equal to or greater than the thickness of the phantom. When the thickness of the phantom was 20 cm or less. homogenous heating was not achieved by using the electrode which diameter was equal to the thickness of the phantom, but achieved by the larger diameter of the electorode. When the sizes of paired electrodes were not equal, the smaller electrode side was preferentially heated.

  • PDF

The Effect of Electrode Spacing and Size on the Performance of Soil Microbial Fuel Cells (SMFC) (전극간 거리와 크기가 토양미생물연료전지의 성능에 미치는 영향)

  • Im, Seong-Won;Lee, Hye-Jeong;Chung, Jae-Woo;Ahn, Yong-Tae
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.36 no.11
    • /
    • pp.758-763
    • /
    • 2014
  • Soil microbial fuel cells (SMFC) have gained a great attention as an eco-friendly technology that can simultaneously generate electricity and treat organic pollutants from the contaminated soil. We evaluated the effect of electrode spacing and size on the performance of SMFC treating soil contaminated with organic pollutants. Maximum power density decreased with increase in electrode distance or decrease in electrode size, likely due to higher internal resistance. The maximum voltage and power density decreased from 326 mV and $19.5mW/m^2$ with 4 cm of electrode distance to 222 mV and $5.9mW/m^2$ with 9 cm of electrode distance. In case of electrode size test, the maximum voltage and power density generated was 291 mV, $0.34mW/m^3$ when both of anode and cathode area were $64cm^2$ with 4 cm of electrode distance. The maximum voltage decreased by 19~29% when the anode area decreased to $16cm^2$ while only 3~12% of voltage decreased with cathode area decrease. The maximum power density decreased by 49~68% with decreasing anode size, and by 29~47% with decreasing cathode size. These results showed that the anode area had more significant effects than the cathode area on the power generation of SMFC which has a high internal resistance due to a coexistence of soil and wastewater in the reactor.

Effect of Electrode Configuration on the Substrate Degradation in Microbial Fuel Cells (미생물연료전지에서 전극구조가 기질분해에 미치는 영향 연구)

  • Shin, Yujin;Lee, Myoung-Eun;Park, Chi-Hoon;Ahn, Yongtae
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.39 no.8
    • /
    • pp.489-493
    • /
    • 2017
  • Microbial fuel cells (MFC) are bio-electrochemical processes that can convert various organic materials present in wastewater into electrical energy. For scaling-up and practical application of MFC, it is necessary to investigate the effect of anode size, electrode distance, and total area of anode on substrate degradation. Spaced electrode assembly (SPA) type microbial fuel cell with multiple anodes treating domestic wastewater was used for simulation. According to computer simulation results, the shorter the distance between electrodes than the size of single electrode, the faster the substrate degradation rate. Particularly, when the total area of the anode is large, the substrate decomposition is the fastest. In this study, it was found that the size of the anode and the distance between the electrodes as well as the cathode electrode, which is known as the rate-limiting step in the design of the microbial fuel cell process, are also important factors influencing the substrate degradation rate.

Electron Emission and Degradation of the Pb($\textrm{Zr}_{0.5}\textrm{Ti}_{0.5}$)$\textrm{O}_3$Electron Guns with Various Upper Electrode Sizes (Pb($\textrm{Zr}_{0.5}\textrm{Ti}_{0.5}$)$\textrm{O}_3$전자총의 상부 전극 크기에 따른 전자 방출 및 열화)

  • Kim, Yong-Tae;Yun, Gi-Hyeon;Kim, Tae-Hui;Park, Gyeong-Bong
    • Korean Journal of Materials Research
    • /
    • v.9 no.10
    • /
    • pp.1032-1036
    • /
    • 1999
  • The electron emission and degradation of the ferroelectric Pb($\textrm{Zr}_{0.5}\textrm{Ti}_{0.5}$)$\textrm{O}_3$ ceramics by the pulse electric field have been investigated as a function of the upper electrode diameter. Polarization increased with the decrease of the upper electrode diameter due to the increase of the volume fraction participated in the polarization reversal near the electrode edge. Simulation using ANSYS 5.3 for the electric field distribution showed that the electric field increased near the upper electrode edge of the asymmetric electrode structure. The ferroelectric volume near the upper electrode edge which contributed to the increase of the polarization and the emission charge per electrode diameter were independent on the upper electrode diameter. Polarization and dielectric constant were decreased due to the erosion of the upper electrode with repeating the emission cycles, but they were recovered by the electrode regeneration. The degradation of the ferroelectric surface resulted in the increase of the coercive field and dielectric loss.

  • PDF

PDP용 Ag 전극과 유전체의 동시소결

  • Kim, Jeong-Hun;Sin, Hyo-Sun;Yeo, Dong-Hun;Hong, Yeon-U;Yun, Ho-Gyu
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.11a
    • /
    • pp.200-200
    • /
    • 2009
  • 상용의 디스플레이로 널리 사용되고 있는 PDP(Plasma Display Panel)는 LCD와의 시장 경쟁으로 인하여 극한의 원가 경쟁 하에 있다. 따라서 각 공정에 대한 공정단가를 낮추기 위한 다양한 공정 및 소재 연구가 진행되고 있다. 그 가운데 하나가 Address와 Bus 전극으로 사용되고 있는 Ag 전극의 저온 소결이다. 이 공정은 저온소결 소재의 개발과 전극에 접촉하는 유전체 층과 matching이 중요하기 때문에 이들 소재의 동시 개발이 필요한 실정이다. 본 연구에서는 Ag 전극의 저온 소성을 위한 다양한 가능성을 검토하였다. 또한, 유전체와 동시 소결 가능한 소재의 특성 향상 및 저온 소성 연구를 동시에 수행하였다. Glass에 대한 유전체 층의 인쇄와 유전체 위에 전극 입자의 크기제어를 통한 기본 조성의 matching 특성을 비교하고 입자 크기가 전극의 소결 온도에 미치는 영향을 비교 평가 하였다. 유전체 층과의 matching 특성을 향상하기 위하여 유전체 조성의 일부를 전극에 첨가하여 두 소재간의 결합력을 증대시키기 위한 실험을 진행하였다. 그 결과를 바탕으로 저온 동시소성이 가능한 전극 소재의 최적화 실험을 실시하고 그 결과 최적의 전극 소재를 제시하였다.

  • PDF

Electrode properties of various carbon anodes containing different sizes and distributions of pores (다양한 기공 크기 및 분포를 갖는 양극 탄소의 전극 특성)

  • 안홍주;오한준;김인기;김세경;임창성;지충수;이재봉;박광규;고영신
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.12 no.1
    • /
    • pp.42-49
    • /
    • 2002
  • Differences in electrode properties and in fluorine electrolysis behaviors of various carbon anodes, which were the YBD-like grade carbon, the YBD grade carbon and the P2X grade carbon, containing different pore sizes and distributions were investigated. The evaluations were performed by measuring their mechanical properties, cyclic voltammograms and chronoamperometries in 0.5 M $K_2SO_4$ solution with 1 mM $[[Fe(CN)_6]^\;{3-}/Fe(CN)_6$] $^{4-}$ redox couple and electrochemical behaviours of fluorine electrolysis in molten KF . 2HF electrolyte at $85^{\circ}C$. It was found that the P2X grade carbon anode showed better electrode properties in the cyclic voltammogram and chronoamperometry than the other carbon anodes while the YBD-like grade carbon anode which contained the pore size of 200~300$\mu$m showed superior electrode properties for fluorine electrolysis to the others. These differences in the electrode properties of various carbon anodes seemed to be owing to different sizes and distributions of pores on their surfaces.

Current of planar switch during the recovering time of the negative pulse (음펄스 전압회복에 따른 평판형 스위치 전극에 흐르는 전류의 거동 관찰)

  • Hwang, Hui-Dong;Choe, James;Ko, Kwang-Cheol;Kim, Gon-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2004.11a
    • /
    • pp.120-122
    • /
    • 2004
  • 평판 스위치 전극에 인가되는 전압 변화에 따라서 전극 앞에서의 플라즈마 전위의 변화를 측정하고, 이를 이용하여 형성된 전계의 변화를 관찰하였다. 대부분 스위치 전각에 인가되는 펄스는 펄스 인가시간, 플래토(plateau)시간, 펄스 회복시간으로 구성되어 이들 세 가지 시간 구간에 따라서 전위의 변화를 측정하여 형성되는 전계를 관찰하였다. 빠른 방전 스위치의 동작특성을 이해하기 위하여 스위치 전극인가 전압의 인가시간 변화와 이에 따른 전압 변화율 및 인가전압의 크기에 따른 플라즈마 쉬스의 거동을 관찰하고, 그 크기가 펄스 변화율과 크기에 따라 변화함을 찾았다. 펄스의 회복시간 동안에 돌아오는 플라즈마 쉬스의 거동은 펄스의 인가시간동안의 변화와 유사한 거동을 보였으며 이때에도 펄스 회복율이 중요한 인자임을 알 수 있었다. 만일 펄스 변화율이 커서, 전극 앞에서의 쉬스의 거동 속도가 플라즈마 이온의 음속보다 빠르게 변할 때는 이온 매트릭스 쉬스의 거동형태를 따르고, 변화율이 늦어서 쉬스의 거동 속도가 이온의 음속보다 느리게 변하는 경우에는 Child-Langmuir 쉬스의 형태가 시간에 따라 전개됨을 알 수 있었다. 펄스 특성을 정량적으로 관찰할 수 있도록 스위치 전극에 흐르는 전류의 크기를 계산하기 위해 필요한 모델을 개발하여 실험견과와의 비교를 통하여 펄스 시간동안 플라즈마의 거동이 스위치를 흐르는 전류에 미치는 영향을 연구하였다.

  • PDF

Electrochemical Performance of Composite Active Materials (Activated Carbon + $LiCoO_2$) Electrode (혼합 활물질 (활성탄소 + $LiCoO_2$) 전극의 전기화학적 특성)

  • Kim, Ick-Jun;Jeon, Min-Jae;Yang, Sun-He;Moon, Seoung-In;Kim, Hyun-Soo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.06a
    • /
    • pp.497-497
    • /
    • 2007
  • 활성탄소를 양쪽 전극에 사용하는 전기이중층 커패시터는 고출력 특성과 반영구적인 cycle 수명인 장점을 가지고 있는 반면, 단위 중랑 또는 부피 당 용량이 작아 메모리 백업용 보조전원으로서의 활용에 그치고 있다. 이를 보완하기 위하여 최근에는 앙쪽의 전극에 충방전 메카니즘을 달리하는 비대칭 전극 설계기술을 기반으로 하는 하이브리드 커패시터가 개발되었고, 에너지밀도로서는 유기계 전해액에서 약 15-20 Wh/kg를 가지는 것으로 보고되고 있다. 본 연구메서는 양극의 활성탄소에 비용량이 상대적으로 큰 LiCo02 분말을 혼합한 하이브리드 전극의 제조 및 전기화학적 특성을 조사하였다. 이때 $LiCoO_2$ 분말의 혼합 종량비의 영향에 의한 전극 부피 당 용량(mAh/cc)의 변화와 $LiCoO_2$ 분말의 입자 크기에 의한 하이브리드 전극의 출력 특성을 조사하였다. $LiCoO_2$ 분말은 불밀을 이용하여 입자크기를 조절하였고, 각각의 입자크기를 가지는 LiCoO2 분말을 활성탄소와 함께 혼합하여 혼합 활물질 : Carbon black : PTFE의 중량비가 90 : 5 : 5가 되도록 sheet 전극을 제조하였다. 제조한 전극을 양극에, Li foil을 음극에, 전해액을 LiPF6 in EC DMC를 사용하여 코인셀을 제조하고 전기화학적 특성은 MACCOR 충방전기를, AC 저항은 AC impedance를 각각 사용하여 평가하였다. 활성탄소에 $LiCoO_2$ 분말의 첨가 중량비가 증가할수록 전극 부피 당 용량은 증가하였으나, 원료 상태의 $LiCoO_2$ 분말의 첨가에서는 코인셀의 전극 저항은 첨가 중량에 따라 단순 증가하였다. 그러나 미세 $LiCoO_2$ 분말을 첨가할 경우, 20%의 첨가에서 전극 저항은 활성탄소 만을 사용한 전극과 동등한 전극저항을 나타내고 충방전 cycle 특성도 개선되는 것을 확인하였다.

  • PDF

A study of the formation of the liner $\lambda$-DNA bridge using the electrostatic interactions on the gold nanoelectrodes (금 나노 전극위에 정전기적 상호작용을 이용한 선형 $\lambda$-DNA 브리지 형성에 관한 연구)

  • Kim, Hyung-Jin;Yi, In-Sun;Roh, Yong-Han;Hong, Byung-You
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.04b
    • /
    • pp.64-67
    • /
    • 2004
  • 본 논문에서는 DNA를 이용한 나노 소자에 응용하기 위하여, photo-lithograpy를 사용하여 나노크기(<100)의 간격을 갖는 금 전극을 제작하였다. 그리고 제작되어진 되어진 나노 전극위에 2-Amino ethanthiol(AET)를 코팅하여 AET와 $\lambda$-DNA 사이의 정전기적 상호 작용을 이용, 금 나노전극 사이에 간단하고 고착율을 높이는 실험을 하였다. SEM(Scanning Electron Microscope) 분석을 통해 나노 크기의 전극 간격을 확인하였고, 두 전극사이에 연결되어진 $\lambda$-DNA는 AFM(Atomic force microscope)을 확인하였다.

  • PDF