• Title/Summary/Keyword: 전극재

Search Result 278, Processing Time 0.026 seconds

Electrode Kinetics for Mixed Ligand Complexes of Cobalt (III) with Bis (ethylenediamine) and Monodendate Ligands (한자리 배위자와 에틸렌디아민의 코발트 (III) 착물에 대한 전극반응 속도론)

  • Jung-Ui Hwang;Jong-Jae Chung;Jae-Duck Lee
    • Journal of the Korean Chemical Society
    • /
    • v.33 no.2
    • /
    • pp.225-231
    • /
    • 1989
  • The heterogeneous rate constants for the electrochemical reduction by $trans-[Co(en)_2X_2](ClO_4)_n$(where X is cyanide, nitrite, ammonia, and isothiocyanate) at mercury and glassy carbon electrode were investigated by cyclic voltammetry, DC polarography, and by using rotating disk electrode. The good linear relationship was obtained between the activation energy of reduction and absorption wave number of complexes on glassy carbon electrode. At mercury electrode, $NO_2^-$ ligated complex showed the large deviation from the linear relationship. The difference in the value of rate constants for $NO_2^-$ ligated complex between mercury and glassy carbon electrode was about three order of magnitude which was much larger than the other complexes. It was suggested that $NO_^-$ ligated complex was reduced by inner-sphere mechanism on mercury electrode from the larger value of activation energy and entropy on mercury than carbon electrode.

  • PDF

Self-Diagnosis of Damage in Carbon Fiber Reinforced Composites Using Electrical Residual Resistance Measurement (잉여 전기 저항 측정을 이용한 탄소 섬유 강화 복합재의 파손 측정)

  • Kang, Ji-Ho
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.29 no.4
    • /
    • pp.323-330
    • /
    • 2009
  • The objective of this research was to develop a practical integrated approach using extracted features from electrical resistance measurements and coupled electromechanical models of damage, for in-situ damage detection and sensing in carbon fiber reinforced plastic(CFRP) composites. To achieve this objective, we introduced specific known damage (in terms of type, size, and location) into CFRP laminates and established quantitative relationships with the electrical resistance measurements. For processing of numerous measurement data, an autonomous data acquisition system was devised. We also established a specimen preparation procedure and a method for electrode setup. Coupon and panel CFRP laminate specimens with several known damage were tested. Coupon specimens with various sizes of artificial delaminations obtained by inserting Teflon film were manufactured and the resistance was measured. The measurement results showed that increase of delamination size led to increase of resistance implying that it is possible to sense the existence and size of delamination. A quasi-isotropic panel was manufactured and electrical resistance was measured. Then three different sizes of holes were drilled at a chosen location. The panel was prepared using the established procedures with six electrode connections on each side making a total of twenty-four electrodes. Vertical, horizontal, and diagonal pairs of electrodes were chosen and the resistance was measured. The measurement results showed the possibility of the established measurement system for an in-situ damage detection method for CFRP composite structures.

Effect of plating and annealing process of laser doped selective emitter solar cells (레이저 도핑된 선택적 에미터 태양전지의 도금 및 열처리 공정의 영향)

  • Lee, Junsung;Kyeong, Dohyeon;Hwang, Myungick;Oh, Hun;Lee, Wonjae;Cho, Eunchul
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.11a
    • /
    • pp.48.2-48.2
    • /
    • 2010
  • 고효율 실리콘 태양전지 개발은 단파장의 광 응답 특성 개선을 위한 선택적 에미터 형성과 반사 손실 개선을 위한 미세 패턴 전극을 형성하는데 집중적인 연구가 진행되고 있다. 본 실험에서는 레이저 도핑된 선택적 에미터 위에 미세 패턴 Ni/Cu 도금 전극을 형성하였다. 니켈과 동 도금은 무전해 Light induced plating(LIP)으로 진행하였다. 니켈 도금 전극의 접착력 개선과 접촉저항 개선을 위해서 니켈 전극을 질소 분위기에서 열처리하여 니켈실리사이드(NiSi)를 형성하였다. 니켈 도금 두께와 니켈실리사이드 열처리 조건을 최적화하여 충실도 77.4%, 변환효율 18.5%를 달성하였다.

  • PDF

X-선 검출기의 이득 보정 및 신호처리회로 구성

  • 남욱원;최철성;문신행
    • Bulletin of the Korean Space Science Society
    • /
    • 1993.04a
    • /
    • pp.22-22
    • /
    • 1993
  • 천체 B-선 관측용으로 많이 이용되고 있는 X-선 비례계수관을 실험실형으로 재작하고 그 특성을 조사하였다. X-선 검출기의 구조는 10 $\times$ 20 $\times$ 2cm3 인 검출체적내에 10개의 전극선이 설치되어있는 다중선 비례계수관이며, 검출가스로서 Argon(90%) + CH4 (10%)인 g혼합가스를 사용하였다. 이러한 구조에서 5.9 keV에 대한 에너지 분해능은 16%를 얻었으나, 정상적인 전극연결방법에서는 검출기 끝측에 위치한 전극에서 생기는 electric field 변형매문에, 양극선 배열방향에서 조정된 이득의 군일성이 나쁘게 나타났다. 따라서 다중선들의 각 전극선에 전압보상법(voltage compansation method)을 적용하여 검출기 전반에 걸친 이득의 균일성을 2 % (rms 값) 이내로 보정할 수 있었다. 아울러 신호처리회로 중 에너지분석을 위한 파고분석기, 비 X-선 재거를 위한 상승시간선별기(rise-time discriminator)등을 제작하였으며 이들을 이용한 전반적인 신호처리회로의 구성에 대하여 논하고자 한다.

  • PDF

전극의 패턴에 따른 유기 광기전력 소자의 전기적 특성

  • Mok, Rang-Kyun;Lee, Won-Jae;Song, Min-Jong;Han, Wone-Keun;Kim, Tae-Wan
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2010.06a
    • /
    • pp.184-184
    • /
    • 2010
  • ITO의 전극 패턴에 따른 유기 광기전력 소자의 전기적 특성에 대해서 연구하였다. 소자의 구조는 ITO/PEDOT:PSS(90nm)/CuPc(20nm)/$C_{60}$(40nm)/LiF(0.5nm)/Al(100nm)이고, PEDOT:PSS는 스핀 코팅한 후 $120^{\circ}C$에서 20분간 건조시켰으며, 유기물은 열증착을 하여 제작하였다. ITO 전극의 패턴을 corss-bar type과 island type으로 하여 소자의 특성을 비교하였다. 광원은 500W xenon lamp를 사용하였고, optical density filter로 광원의 세기를 조절하였으며, AM 1.5G의 스펙트럼을 조사하였다. PEDOT:PSS 층을 사용함으로서 유기 광기전력 소자의 효율, 단락 전류, 그리고 개방 전압의 향상을 얻을 수 있었다. ITO 전극 패턴에 따른 광기전력 소자의 특성은 cross-bar type에 비하여 island type의 구조에서 유기 광기전력 소자의 효율이 34% 감소하였다.

  • PDF

Electrochemical Characterization of Animal Tissue-Immobilized Carbon Paste Biosensor Bound with Chloroprene Rubber (클로로프렌 고무로 결합된 동물조직 고정 탄소반죽 전극의 전기화학적 특성)

  • Rhyu, Keun-Bae
    • Applied Chemistry for Engineering
    • /
    • v.22 no.1
    • /
    • pp.114-118
    • /
    • 2011
  • Even though the carbon paste electrode bound with mineral oil is useful for research about the characteristics of enzymes, it remains far from practical uses because the lack of mechanical hardness limits its practical use. When the rubber liquefied in toluene was used as a binder of carbon powder in lab, it is confirmed that the mechanical robustness of the electrode is guaranteed. In order to confirm whether it shows quantitative electrochemical behaviors or not, its kinetic parameters, e.g. the symmetry factor (${\alpha}=0.28$), the exchange current density ($i_0=4.06{\mu}A/cm^2$), the capacity of the double layer ($C_d=2.11{\times}10^{-3}F$), the Michaelis constant ($K_M=2.45{\times}10^{-3}M$), and the time constant (${\tau}_B=0.077sec$) were investigated. Our experimental observations prove that the chloroprene rubber is a promising binder for the practical use of a carbon paste electrode.

Poly-3,4-dihydroxybenzoic Acid Film Electrodes Modified with Dopamine for Determination of Ti(IV) Ions (도파민으로 수식된 3,4-dihydroxybenzoic acid 고분자 피막전극을 이용한 Ti(IV)이온의 정량)

  • Cha, Seong-Keuck
    • Journal of the Korean Electrochemical Society
    • /
    • v.6 no.2
    • /
    • pp.130-133
    • /
    • 2003
  • 3,4-dihydroxybenzoic acid(3,4-DHBA) was electropolymerized on glassy carbon electrode to give the GC/p-3,4-DHBA type electrode which was modified with dopamine by the help of 1-(3-dimethylaminopropyl)-3-ethyl carbodiimide hydrochloride(EDC) acting as a coupling agent. The carboxylic sites on the polymeric surface of p-3,4-DHBA and mine group at the dopamine gave a QCA(Au)/p-3,4-DHBA-dopamine type of modified electrodes. The o-quinone moieties at the electrode surface exhibited high selectivity to titanium ions in solution. The redox process of the electrode is hydroquinone : quinone +$2H^+2e^-$, which had two strong and two weak pairs of peaks at CV. The modified electrode can deposit Ti(IV) ions as much as $4.13\times10^{-5}gcm^{-2}$. The calibration curve of the electrodes, log of the surface coverage-normalized redox response vs log[Ti], exhibited an excellent correlation$(r{\geq}0.997)$ for titanium concentrations ranging from $5.25\times10^{-4}\;to\;5.25\tiems10^{-8}M.$.

Improved Cycle Performance of High-Capacity SiOx Negative Electrodes with Carbon Nanotube Conducting Agents for Lithium-Ion Batteries (탄소나노튜브 도전재 적용을 통한 리튬이온 이차전지용 고용량 SiOx 음극의 사이클 성능개선)

  • Hyang Sun Jeon;Ji Heon Ryu
    • Journal of the Korean Electrochemical Society
    • /
    • v.26 no.3
    • /
    • pp.35-41
    • /
    • 2023
  • The carbon-coated silicon monoxide (c-SiOx), which is a negative electrode active material for lithium-ion batteries (LIBs), has a limited cycle performance due to severe volume changes during cycles, despite its high specific capacity. In particular, the significant volume change of the active material can deform the electrode structure and easily damage the electron transfer pathway. To improve performance and mitigate electrode damage caused by volume changes, we replaced parts of the carbon black conducting agent with carbon nanotubes (CNTs) having a linear shape. The content of the entire conductive material in the electrode was fixed at 10% by mass, and the relative content of CNTs ranged from 0% to 25% by mass to prepare electrodes and evaluate electrochemical performance. As the CNT content in the electrode increased, both cycle life and rate capability improved. Even a small amount of CNT can significantly improve the electrochemical performance of a c-SiOx negative electrode with large volume changes. Furthermore, dispersing CNTs effectively can lead to achieving the equivalent performance with a reduced quantity of CNTs.

Electrical Resistivity Survey on Paved Surface and Case Studies (포장된 지표에서의 전기비저항 탐사 및 사례 연구)

  • Juyeon Jeong;Myungjin Nam
    • The Journal of Engineering Geology
    • /
    • v.34 no.2
    • /
    • pp.295-315
    • /
    • 2024
  • Urban development and the expansion of electrical resistivity surveying applications have increased the need for soil and underground structure investigations on paved surfaces. Traditional methods involved drilling through the pavement or surveying surrounding soil. Recently, non-invasive surveying techniques have been developed. This paper analyzes these methods, categorizing them into galvanic methods (including drilling and flat ground electrodes) and capacitive coupling methods. By examining case studies, it suggests selecting the appropriate method based on the pros and cons of each and the specific site characteristics. The paper also discusses the applicability and limitations of electrical resistivity surveying through various examples.