• Title/Summary/Keyword: 적정양수량

Search Result 34, Processing Time 0.039 seconds

The Evaluation of Safe Yield Considered Interference Drawdown between Hot Spring Wells at Yecheon Hot Spring Area (예천온천지구내 온천공간 수위간섭을 고려한 적정양수량 평가)

  • Lee, Chol-Woo
    • The Journal of Engineering Geology
    • /
    • v.17 no.3
    • /
    • pp.405-409
    • /
    • 2007
  • There exist 5 wells drilled at the Yecheon hot spring area, the distance between the wells is about $159m{\sim}702.6m$. The safe yield of each well is controlled by interference drawdown between a pumping well and an observation well after pumping test. The well No. 2 and the well No. 5 are the closest, at the distance of 159 m; therefore interference drawdown between two wells was occurred considerably. The drawdown of the well No. 2 (an observation well) was 16.67 m; the drawdown of the well No. 5 (a pumping well) was 17.21 m. The degree of the interference is about 97% and the safe yield decreased from $750m^3/day\;to\;24m^3/day$. Significant interference between two wells is due to the fact that the aquifer has 1.5 dimensions.

Optimal Pumping Rate of a Water Well at Imgokri, Sangju City (상주시 임곡리 굴착공의 적정양수량 결정)

  • Cho, Byong-Wook;Yun, Uk;Moon, Sang-Ho;Lee, Byeong-Dae;Cho, Soo-Young;Kim, YongCheol;Hwang, Seho;Shin, Jehyun;Ha, Kyoochul
    • The Journal of Engineering Geology
    • /
    • v.27 no.3
    • /
    • pp.255-265
    • /
    • 2017
  • We have determined the optimal pumping rate of the PW-2 water well (depth=100 m) at Imgokri, Sangju City. Cutting analysis and geophysical logging data reveal water-producing horizons at 26.1-26.5, 28.0-30.0, 33, 58, and 71 m. For pumping rates of 40, 55, 70, 90, and $132m^3/d$ over 70 days, the estimated drawdown from the PW-2 well was 6.48, 11.56, 18.07, 28.99 and 60.26 m, respectively. During a constant-rate pumping test at a rate of $117m^3/d$, the cone of depression intersected an impermeable boundary after 120-150 min of pumping. Therefore, we consider the critical pumping rate for well PW-2 to be $90m^3/d$. After pumping at $90m^3/d$ for 70 days, the calculated drawdown was 28.82-31.27 m. We suggest an optimal pumping rate for well PW-2 of $70-90m^3/d$, as the optimal pumping rate should be similar to the critical pumping rate. Sharp increases in the slope of the time-drawdown relationship, dissolved oxygen concentrations, and oxidation-reduction potential during the constant-rate pumping test indicate the limited development of bedrock aquifers around PW-2.

The Evaluations of Daily Safe Yield and Influence of Hot Spring Wells (온천공에 대한 일일 적정양수량 및 영향평가)

  • Lee, Chol-Woo;Moon, Sang-Ho;Kim, Hyeong-Chan
    • Journal of Soil and Groundwater Environment
    • /
    • v.11 no.4
    • /
    • pp.41-47
    • /
    • 2006
  • The evaluations of daily safe yield and reciprocal influence of hot spring wells are important subjects that the specialized agencies of hot spring has to survey. The survey of hot spring had been executed by Korea Institute of Geoscience and Mineral Resources (KIGAM) prior to 1996. However, as of 2006, eight specialized agencies of hot spring are working on it and so the survey of hot spring is not consistent now. This study was carried out to analyze data from hot spring in the same way by every specialized agency. The time of residual drawdown was applied to evaluate daily safe yield because some of wells have slow recovery of drawdown. The reciprocal influence between hot spring wells was evaluated by drawdown of observation wells when a new well was pumped.

Assessment of Water Supply of Pumped-Storage Type Reservoir according to Climate Change (기후변화에 따른 양수저류형 저수지 용수공급능력 평가)

  • Lee, Jaenam;Shin, Hyungjin;Kim, Haedo;Kang, Seokman
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2018.05a
    • /
    • pp.224-224
    • /
    • 2018
  • 농업용저수지는 전국에 약 18,000여 개소에 이르며 지역특성에 따라 농업용수를 공급하는 체계가 각각 다르다. 저수지 용수공급체계는 자체유역에서 확보된 용수를 해당 수혜면적에 공급하는 것이 대표적이지만, 유역면적이 작거나 없어 용수확보가 어려운 지역은 양수시설을 통해 간접유역의 하천수나 재이용수 등을 저수지에 저류한다. 양수저류형 저수지의 설계를 위해 다양한 양수조건을 고려한 물수지분석을 수행하고 저수지의 설계용량 및 적정 양수량을 결정하고 있다. 그러나 최근 기후변화 등으로 인해 수자원 환경의 변화로 농업용수가 부족해지고 있는 상황 속에서 양수 저류형 저수지에 대한 용수공급능력의 재평가가 필요한 실정이다. 따라서 본 연구에서는 기후변화에 따른 양수저류형 저수지의 용수공급능력을 재평가하였고, 물 부족을 극복하기 위한 적정 양수량을 산정하였다. 대상저수지는 ${\bigcirc}{\bigcirc}$저수지로 선정하였고 저수지 모의운영을 위한 양수량, 관개 재이용수 비욜 등의 입력정보는 당초 설계에 적용된 값을 사용하였다. 과거 기상자료는 1980-2010년, 미래 기후정보는 2011-2100까지로 RCP 4.5와 RCP 8.5 기후변화 시나리오를 적용하였다. 과거 및 미래 기후정보를 적용하여 양수저류형 저수지의 모의운영을 수행하고 이수안전도 90%의 만족여부를 검토하였다. 또한 기후변화에 대비하여 안정적 용수공급을 위한 적정 양수량을 산정하고 이를 비교 분석하였다. 본 연구결과는 물 부족 지역의 농업용수 공급을 위한 양수저류형 저수지 운영에 있어 저수지 물관리의 기초정보로 활용될 수 있을 것으로 기대된다.

  • PDF

Study on Permeability, Optimum Yield and Long-term Stability in Alluvial Well with Filter Layer Change (충적우물에서 필터층 변화에 따른 투수특성, 적정양수량 및 장기적 안정성에 대한 연구)

  • Song, Jae-Yong;Lee, Sang-Moo;Choi, Yong-Soo;Kim, Ki-Joon;Jeong, Gyo-Cheol
    • The Journal of Engineering Geology
    • /
    • v.28 no.1
    • /
    • pp.101-115
    • /
    • 2018
  • This study was carried out to evaluate the effects of various filter conditions on unconfined aquifer (alluvial aquifer). We made model test device which has filter layer, pumping well and observation well which consist of sand layer and gravel layer to test. Step drawdown test and long term pumping tests were carried out using the device. The permeability characteristics of each test group were confirmed and the optimal yield was calculated. As a result of comparing the optimal yield of double filter and single filter in sand, dual-filter SD-300 was valued at 216.8 % higher final optimal yield than single-filter SS-300. Comparing the dual filter SD-300 and the single filter SS-100 with a thin filter layer, dual-filter SD-300 was valued at 709.2% higher final optimal yield than single-filter SS-300. As a result of analysis of optimal yield change over time, It was confirmed that the ratio of optimal yield of single filter and dual filter increase over time. In order to evaluate the long-term change in water intake efficiency, we considered the point at which the initial optimal yield was reduced by 50%. The dual filter SD-300 is about 351.1% higher than SS-300, which is the same thickness filter, and about 579.0% higher than SS-100. From these results, Assuming that the point at which the initial quantity of water intake is reduced to 50% is the well life, double filters are expected to increase their lifespan by about 3.5 times over single filters of the same thickness and by about 5.8 times over typical single filter. These results can be used to design wells to river bank filtration or filtered seawater. In addition, it is possible to clarify the effect of the double filter through the comparison with the future field test results.

Design of Optimal Wet-Season Injection Well for Augmenting Groundwater Resources in Coastal Areas (해안지역 지하수자원 확충을 위한 우기 인공주입정의 최적설계)

  • Park, Nam-Sik;Shi, Lei;Cui, Lei;Lee, Chan-Jong;Mun, Yu-Ri
    • Journal of Korea Water Resources Association
    • /
    • v.42 no.5
    • /
    • pp.415-424
    • /
    • 2009
  • Artificial injection of surplus surface water during wet seasons and recovery is one of possible solutions for conjunctive uses of surface water and groundwater. The methodology is especially attractive for regions of monsoon type weather. In this work a simulation-optimization model is developed to identify an optimal injection system to sustain an over-exploiting freshwater pumping well. The injection well is to be operated during wet seasons only while the pumping well is to be operated throughout an entire year. The objective function is the minimization of injected volume of freshwater. Saltwater intrusion and dry wells are considered as constraints. An example application is made on a small hypothetical island with poor hydrogeologic conditions. The optimization model is successful in determining optimal injection locations and rates for various cases.

Calculation of the Yeild of Bank Filtration by Using the Horizontal Collector Well (방사형집수정에 의한 강변여과수 산출량 산정)

  • Chung Ji Hoon;Park Jae Hyun;Park Chang Kun;Yang Jung Suk
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2005.05b
    • /
    • pp.250-254
    • /
    • 2005
  • 국내의 상수원수 확보는 대부분을 표류수에 의존하고 있으나, 표류수의 경우 수질오염의 증가와 돌발 수질 오염 사고에 대한 대응 등의 취약점을 가지고 있다. 이러한 문제점을 해결하기 위해 근본적으로 깨끗한 상수원수를 확보하기 다양한 방법이 모색되어지고 있다. 수량적으로 안정적이고, 수질적으로 안전한 상수원수 취득 방법으로 강변여과수, 지하댐, 인공함양기법 등이 실질적으로 계획되어 시행되어지고 있다. 특히 강변 충적층의 자연정화 기능을 이용한 강변여과수 개발은 지하수 개발과 달리 수량적으로 안정적이고, 수질적으로 안전한 강변여과수 개발 방안이 적극적으로 진행되고 있다. 낙동강 하류 지역인 함안군, 창원시, 김해시 등은 대부분 하천 표류수에 의존하였으나, 유역내 충적층 발달 지역이 분포해 있고, 하상경사, 하상계수 등의 하천공학적 측면에서 강변여과수 개발에 유리한 입지조건을 가지고 있어 강변여과수 개발이 진행되고 있다. 현재 창원시 대산면 일대에서 국내최초로 방사형집수정을 이용한 강변여과수 개발이 진행되고 있으며, 현재 방사형 취수정 1기가 시공 완료되어 시험 가동 중에 있다. 본 연구에서는 창원시 대산면 일대에서 진행되고 있는 방사형 집수정 설치에 따른 양수시험을 실시하여 양수량에 따른 수위하강 겋항 등을 분석하여 적정 산출량을 결정하였고, 계획단계에서 적정 산출량 예상시 사용한 경험식(Petrovic, Milojevic 경험식)의 적합성 여부에 중점을 두어 진행 되었다. 연구대상 지역인 창원시 대산면 일대는 지하수위가 하천수위보다 높은 이득하천의 형태로 건기시 하천특성을 뚜렷하며, 양수실험을 위한 대용량 양수펌프 설치, 유량검증을 위한 대형 웨어 설치, 수위변화 측정을 위한 디지털 수위계 등을 설치하여 실험을 수행하였다. 단계/장기양수시험을 통하여 양수량-수위하강 경향을 분석하여 방사형 집수정 1기의 적정 양수량은 약 $16,000m^3/day$로 예상하였으며, 계획 시 사용한 경험식(Milojevic)으로 산정된 산출예상량과 유사한 특성을 나타내었다.

  • PDF

지반 침하 지역에서 적정 채수량 산정을 위한 현장 시험 방안 제시

  • Seok Hui-Jun;Im Eun-Sang;Won Lee-Jeong;Kim Hyeong-Su;Lee Gang-Bok
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2005.04a
    • /
    • pp.420-424
    • /
    • 2005
  • K시 강변여과수 개발 지역에서 적정 채수량 산정 및 지표수 연계 특성을 파악하기 위한 적절한 현장 시험 세부계획 수립과 그 근거를 마련하였다. 일반적으로 단계양수시험을 통하여 적정 채수량 산정 후, 산정된 적정 채수량으로 장기양수 시험을 통하여 주변 수리권에 미치는 지하수위 변화와 강변여과수의 수질변화를 관찰하여 지표수와 연계한 변동특성을 파악하는 일련의 과정을 생각할 수 있다. 그러나 K시 강변여과수 개발 지역과 같은 연약 지반에서는 단계 양수시험시의 높은 양수량에 인한 지반 침하의 우려로 인해 이에 대한 공정의 변화가 불가피하였다. 따라서 현장 시험 공정 순서를 바꾸어서 장기 양수 시험 후 단계양수시험을 수행하는 새로운 대안을 모색하였고 이를 뒷받침 해주는 근거를 제시하고자 한다. 뿐만 아니라 단계양수시험의 단계별 적절한 양수시간을 합리적, 효율적으로 결정하여 경제적이면서 가급적 빠른 시간 내에 단계양수시험을 완료 가능하게 만들고, 가능한 한 더 오랜 기간동안 장기 양수 시험을 가능하게 함으로써 제한된 시간내에 많은 수리지질학 및 화학적인 정보를 얻을 수 있도록 하였다.

  • PDF

A Study on the Seawater Filtration Characteristics of Single and Dual-filter Layer Well by Field Test (현장실증시험에 의한 단일 및 이중필터층 우물의 해수 여과 특성 연구)

  • Song, Jae-Yong;Lee, Sang-Moo;Kang, Byeong-Cheon;Lee, Geun-Chun;Jeong, Gyo-Cheol
    • The Journal of Engineering Geology
    • /
    • v.29 no.1
    • /
    • pp.51-68
    • /
    • 2019
  • This study performs to evaluate adaptability of seashore filtering type seawater-intake which adapts dua1 filter well alternative for direct seawater-intake. This study varies filter condition of seashore free surface aquifer which is composed of sand layer then installs real size dual filter well and single filter well to evaluate water permeability and proper pumping amount according to filter condition. According to result of step aquifer test, it is analysed that 110.3% synergy effect of water permeability coefficient is happened compare to single filter since dual filter well has better improvement. dual filter has higher water permeability coefficient compare to same pumping amount, this means dual filter has more improved water permeability than single filter. According to analysis result of continuous aquifer test, it is evaluated that dual filter well (SD1200) has higher water permeability than single filter well (SS800) by analysis of water permeability coefficient using monitoring well and gauging well, it is also analysed dual filter has 110.7% synergy effect of water permeability coefficient. As a evaluation result of pumping amount according to analysis of water level dropping rate, it is analysed that dual filter well increased 122.8% pumping amount compare to single filter well when water level dropping is 2.0 m. As a result of calculating proper pumping amount using water level dropping rate, it is analysed that dual filter well shows 136.0% higher pumping amount compare to single filter well. It is evaluated that proper pumping amount has 122.8~160% improvement compare to single filter, pumping amount improvement rate is 139.6% compare to averaged single filter. In other words, about 40% water intake efficiency can be improved by just installation of dual filter compare to normal well. Proper pumping amount of dual filter well using inflection point is 2843.3 L/min and it is evaluated that daily seawater intake amount is about $4,100m^3/day$ (${\fallingdotseq}4094.3m^3/day$) in one hole of dual filter well. Since it is possible to intake plenty of water in one hole, higher adaptability is anticipated. In case of intaking seawater using dual filter well, no worries regarding damages on facilities caused by natural disaster such as severe weather or typhoon, improvement of pollution is anticipated due to seashore sand layer acts like filter. Therefore, It can be alternative of environmental issue for existing seawater intake technique, can save maintenance expenses related to installation fee or damages and has excellent adaptability in economic aspect. The result of this study will be utilized as a basic data of site demonstration test for adaptation of riverside filtered water of upcoming dual filter well and this study is also anticipated to present standard of well design and construction related to riverside filter and seashore filter technique.