• Title/Summary/Keyword: 저항 요소

Search Result 939, Processing Time 0.025 seconds

Characteristics of Neutral Point Loci on Line Voltages to Hull When Insulation Resistance Collapses by Earthing Faults at 3 Phase Power Distribution Systems Onboard Vessels (선박 3상배전선로의 지락고장에 따른 대지전압 중성점의 이동경로 특성)

  • Choi, Soon-Man
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.35 no.8
    • /
    • pp.1117-1123
    • /
    • 2011
  • Ungrounded power systems are adopted onboard vessels which enable more stabilized power supply even in case of electric leakage to hull. If earthing faults happen at these systems, they make grounding impedances of power lines unbalanced each other on the three phases, resulting in high voltages to hull which can bring more possibilities of electric shocks and electric fires. This study focuses on how to configure a calculation module for transferring a grounded condition by lowered insulation resistance into a vector diagram of the voltages to hull. By using the module, the loci of neutral points were acquired to analyze how voltages to hull are affected by earthing faults and the distributed capacitances between power lines and hull. The suggested module was simulated and compared to the measured values from a test power system in good results.

Estimates of Partial Safety Factors of Circumferential Through-Wall Cracked Pipes Based on Elastic-Plastic Crack Initiation Criterion (탄소성 균열개시조건에 대한 원주방향 관통균열 배관의 부분안전계수 계산)

  • Lee, Jae-Bin;Huh, Nam-Su
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.38 no.11
    • /
    • pp.1257-1264
    • /
    • 2014
  • Efforts are presently underway for developing an optimal design methodology for GEN-IV nuclear reactors based on target failure probabilities. A typical example is the system-based code, in which the results are represented in the form of partial safety factors (PSFs). Thus, a PSF is one of the crucial elements in either component design or integrity assessment based on target failure probabilities during the operation period. In the present study, a procedure for calculating the PSF of a circumferential through-wall cracked pipe based on the elastic-plastic crack initiation criterion is established, in which the importance of each input variable is assessed. Elastic-plastic J-integrals are calculated using the GE/EPRI and reference stress methods, and the PSF values are calculated using both first- and second-order reliability methods. Moreover, the effect of statistical distributions of assessment variables on the PSF is also evaluated.

Study about the Standard of Anti-icing System Based on Geography and Geometric Designs (기하구조 및 지형적 요소를 고려한 융설시스템 설치 기준 정립에 관한 연구)

  • Lee, Dong-Hyun;Jeong, Won-Seok;Kim, Ji-Won;Ko, Seok-Beom
    • International Journal of Highway Engineering
    • /
    • v.13 no.2
    • /
    • pp.95-102
    • /
    • 2011
  • Anti-icing system can immediately respond when snowing is expected or the snow comes down on the road surface. It has been recognized that the system can reduce traffic accidents and congestion by quickly removing the frozen road surface area. However, it is very difficult to implement this system due to the expensive equipment installation and operation cost, Recently, there was a developed program for predicting the freezing area using three-dimensional model and tracking the sun path. But, there is no objective analysis method and all developed approaches are different so that the general standard of anti-icing system is needed. In this study, we proposed the decision criteria for determining application priorities of the anti-icing system based on weather and road conditions, i.e., geometric and topographic conditions. Regional climate survey, topographical analysis, and dynamic vehicle simulation considered road geometry and skid resistance was conducted to standardize the installation method of anti-icing system.

A Study on Flexural Ductility of Longitudinally Stiffened Plate Girders (수평보강재가 설치된 플레이트 거더의 휨 연성에 관한 연구)

  • Yoon, Dong Yong;Kim, Kyung Sik
    • Journal of Korean Society of Steel Construction
    • /
    • v.19 no.6
    • /
    • pp.643-653
    • /
    • 2007
  • The ultimate bending strength and flexural ductility performance of longitudinally stiffened plate girders fabricated with mild steel were investigated utilizing nonlinear incremental finite element analysis. AASHTO LRFD (2002) design specifications were reviewed for possible application of longitudinally stiffened plate girders as compact sections. In order to investigate compact section requirements for plate girders with longitudinal stiffeners in webs, a number of full-scale plate girders were modeled and analyzed up to the collapse under pure bending condition. It was found that the slenderness of sub panel of the webs, the stiffness of longitudinal stiffeners, and the slenderness of compression flanges are key parameters governing the flexural ductility of the plate girders. It was also found from finite element analysis that longitudinally stiffened plate girder sections can satisfy compact section requirements both in full plastic moment capacity and flexural ductility requirement. New design equations have been proposed for longitudinally stiffened plate girders to be treated as compact sections.

Development & Practical Installation of 400kV XLPE 1C${\times}$2500SQ Enamel coating Power Cable Accessories (400kV Enameled Cu 1C${\times}$2500SQ 케이블 접속재 개발 및 실선로 적용)

  • Kim, Young-Tek;Kim, Hyun-Ju;Kim, Han-Hwa;Park, Jeong-Ki;Han, Du-Hyun;Choi, Man-Ok
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.1614-1616
    • /
    • 2011
  • 지중송전라인에서 전압등급의 상승은 선로손실을 줄이면서 밀집된 전력수요에 대응하거나 특별히 고전압 수요를 맞추기 위한 것으로 이것은 XLPE Cable의 제조기술이 향상되면서 지속적으로 진행되어온 초고압송전계통의 일반적 추세이다. 이러한 경향으로 해외에서는 케이블 도체의 송전용량을 증대시킬 수 있는 방법으로 케이블 도체에 에나멜 코팅을 하여 집합을 한다. 그러므로써 기존 케이블에서 발생되는 표피현상 및 근접효과에 의한 AC 저항 요소를 줄여 요구하는 전류용량을 기존 비소선절연 케이블에 비해 더 많이 송전할 수 있다. 하지만, 소선절연 케이블이 전류 용량을 증대 시킬 수 있는 장점은 있으나 접속재의 경우 도체의 에나멜 코팅을 제거해야 하는 문제점이 있다. 당사는 에나멜 코팅을 제거하는 방법을 개발 완료함으로써 본 접속재의 개발을 앞당길 수 있었다. 당사는 쿠웨이트 400kV MEW/C/3931 Project에 400kV XLPE 1C${\times}$2500SQ 소선절연 초고압송전라인을 적용하였는데 본고에서는 여기에 적용된 400kV XLPE 1C${\times}$25000SQ 소전절연 케이블 부속재의 신뢰성을 높이기 위한 설계방법, 시험 및 시공에 대하여 요약하였다.

  • PDF

Research on Emotion Evaluation using Autonomic Response (자율신경계 반응에 의한 감성 평가 연구)

  • 황민철;장근영;김세영
    • Science of Emotion and Sensibility
    • /
    • v.7 no.3
    • /
    • pp.51-56
    • /
    • 2004
  • Arousal level has been well defined by autonomic responses. However, entire emotion including both valence and arousal level is often questioned to be completely described by only autonomic responses. This study is to find the autonomic physiological parameters which were used emotion evaluation, 15 undergraduate students were asked to watch eight video clips from diverse movies and comedy shows for experiencing emotions. The subjectively experienced emotion were grouped by three factors. Two dimensional emotion model having the pleasant-unpleasant and arousal-non arousal factors were mapped with three physiological responses(GSR, PPG, SKT). The results may suggest that PPG and GSR may be used as arousal index while SKT may pleasant index. And the complex relation of physiological responses to emotional experiences are discussed.

  • PDF

A Study on the Heat Transfer Characteristics in the Composite Heat Pipe as Modeling Turbine Rotor (터어빈 회전차를 모델로하는 복합 히이트파이프의 전열특성에 대한 연구)

  • Kwon, Sun-Sok;Jang, Yeong-Suc;Yoo, Byung-Wook
    • Solar Energy
    • /
    • v.13 no.2_3
    • /
    • pp.120-132
    • /
    • 1993
  • The purpose of this research is to study the characteristics of heat transfer in composite rotary heat pipe as modeled turbine rotating by a finite element analysis and experiment. Nu number, Re number, Pr number and dimensionless condensate layer thickness by thermal input and revolutions per minute were given as analysis factors. The comparison between calculated and experimental data showed similar tendency. Therefore the analysis method may be useful to predict the performance of composite heat pipe. The resistance on heat pipe showed the best effect of heat transfer by film condensation, by decreasing film condensation, the heat transfer rate from condenser was increased rapidly. The dimensionless condensate layer thickness according to Re number at given Pr number showed constant values, the dimensionless condensate layer thickness is proportionate to the square root of inverse of revolution number per minute. In this study Nu=A$({\delta}({\omega}/v)^{-1/2}Re^B)$ is used to the convection heat transfer coefficient and A=0.963, B=0.5025 were obtained as analysis predicts.

  • PDF

Shear Strength of the Vertical Joints in Precast Concrete Large Panel Structures (대형 콘크리트 판넬구조의 수직접합부 전단강도에 관한 연구)

  • 서수연;이원호;이리형
    • Magazine of the Korea Concrete Institute
    • /
    • v.6 no.1
    • /
    • pp.111-119
    • /
    • 1994
  • The strength of vertical joints of precast concrete large panel structures depends on the many factors, such as the bond strength of grout concrete (or mortar), the interlocking of the shear keys, the dowel action of horizontal bars. Many experimental studies have been conducted to in vestigate the shear strength of the vertical joints. In domestic, a few design formulas to predict shear strength of the vertical joint were proposed by some investigators, but formulas were based on limited experimental results. The objective of this paper is to propose a suitable formula for the shear strength of vertical joints with 94 vertical joints experimental data using the modified Mohr-Coulomb's 4ield theory and regression analysis. From the comparison of the proposed formula with others, it is shown that the proposed formula can be used economically for the design of vertical joints.

Nonlinear Analysis of RC Shell Structures Including Creep and Shrinkage Effects (크리프와 건조수축을 고려한 RC쉘 구조물의 비선형 해석)

  • 정진환;한충목;조현영
    • Magazine of the Korea Concrete Institute
    • /
    • v.5 no.2
    • /
    • pp.181-188
    • /
    • 1993
  • In this study, a numerical method for the material nonlinear analysis of reinforced concrete shell structures including the time dependent effects due to creep and shrinkage is developed. Degenerate shell elements with the layered approach are used. The perfect or strain hardening plasticity model in compression and the linearly elastic model in tension until cracking for concrete are employed. The reinforcing bars are considered as a steel layer of equivalent thickness. Each :steel layer has an uniaxial behaviour resisting only the axial force in the bar direction. A bilinear idealization is adopted to model elasto-plastic stress-strain relationships. For the nonlinear anaysis, incremental load method combined with unbalanced load iterations for each load increment is used. To include time dependent effects of concrete, time domain is divided into several time steps which may have different length. Some numerical examples are presented to study the validity and applicability of the present method. The results are compared with experimental and numerical results obtained by other investigator.

Stacking Sequence Design of Fiber-Metal Laminate Composites for Maximum Strength (강도를 고려한 섬유-금속 적층 복합재료의 최적설계)

  • 남현욱;박지훈;황운봉;김광수;한경섭
    • Composites Research
    • /
    • v.12 no.4
    • /
    • pp.42-54
    • /
    • 1999
  • FMLC(Fiber-Metal Laminate Composites) is a new structural material combining thin metal laminate with adhesive fiber prepreg, it nearly include all the advantage of metallic materials, for example: good plasticity, impact resistance, processibility, light weight and excellent fatigue properties. This research studied the optimum design of the FMLC subject to various loading conditions using genetic algorithm. The finite element method based on the shear deformation theory was used for the analysis of FMLC. Tasi-Hill failure criterion and Miser yield criterion were taken as fitness functions of the fiber prepreg and the metal laminate, respectively. The design variables were fiber orientation angles. In genetic algorithm, the tournament selection and the uniform crossover method were used. The elitist model was also used to be effective evolution strategy and the creeping random search method was adopted in order to approach a solution with high accuracy. Optimization results were given for various loading conditions and compared with CFRP(Carbon Fiber Reinforced Plastic). The results show that the FMLC is more excellent than the CFRP in point and uniform loading conditions and it is more stable to unexpected loading because the deviation of failure index is smaller than that of CFRP.

  • PDF