• Title/Summary/Keyword: 저항 요소

Search Result 933, Processing Time 0.025 seconds

Experimental and Numerical Study of Heating Characteristics of Discontinuous Carbon Fiber-Epoxy Composites (불연속 탄소섬유-에폭시 복합재의 발열성능 평가)

  • Kim, Myungsoo;Kong, Kyungil;Kim, Nari;Park, Hyung Wook;Park, Ounyoung;Park, Young-Bin;Jung, Mooyoung;Lee, Sang Hwan;Kim, Su Gi
    • Composites Research
    • /
    • v.26 no.1
    • /
    • pp.72-78
    • /
    • 2013
  • This study explores the resistive heating characteristics of discontinuous carbon fiber (CF)-epoxy composites. Test samples including 1, 3, and 5 wt.% CF were fabricated using sonication and cast molding processes. For heating performance characterization, DC currents were applied to the composite samples, and surface temperatures were evaluated visually and quantitatively using an infrared camera. To estimate the thermal performance of composites and verify the experimental results, finite element analyses were performed. The resistive heating mechanism was investigated in connection with CF loading and applied voltages. Resistive heating efficiency increased proportionately with CF concentration and applied voltage. To obtain homogeneous temperature distribution of the samples, high degree of CF dispersion is required.

Implementation of Electrical Performance Test Evaluation System for Car Fuel Heater (차량 연료히터의 전기적 성능시험 평가 시스템 구현)

  • Yoon, Dal-Hwan
    • Journal of IKEEE
    • /
    • v.17 no.1
    • /
    • pp.63-70
    • /
    • 2013
  • In this paper, we have implemented the performance evaluation system of the unified fuel heater for CRDI diesel engine. If the diesel engine be cold by low temperature in winter, then that makes the waxing materials like a paraffin and is the source of poor engine starting. The unified fuel heater is the barrow meter that estimate the start performance of diesel engine, and be tested by test chamber. The chamber perform the normal temperature, an extremely low temperature, an operating performance in an extremely high temperature, the resistance operation delay time and current operation delay time in setting up test resistance, the bimetal delay time test in temperature variation, the current and resistor test of the composited heater, a heating operation test.

Thermal and Stress Analysis of Power IGBT Module Package by Finite Element Method (유한요소법에 의한 대전력 IGBT 모듈의 열.응력해석)

  • 김남균;최영택;김상철;박종문;김은동
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.6 no.4
    • /
    • pp.23-33
    • /
    • 1999
  • A finite element method was employed fort thermal and stress analyses of an IGBT module of 3-phase full bridge. The effect of material parameters such as substrate material, substrate area, solder thickness on the temperature and stress distributions of the module packages has been investigated. Thermal analysis results have also been compared by setting of boundary conditions such as equivalent heat transfer coefficient or constant temperature at a base metal surface of the package. The increase of ceramic substrate area up to 3 times does little contribution to the reduction(8.9%) of thermal resistance, while contributed a lot to the reduction(60%) of thermal stress. Thicker solder resulted in higher thermal resistance but did slightly reduced thermal stresses. It is revealed by the stress analysis that maximum stress was induced at the region of copper pads which are bonded with ceramic substrate.

  • PDF

The Effects of Differential Axial Shortening on RC High-rise Buildings with Outrigger or Mega Structure Systems (아웃리거구조시스템과 메가구조시스템 적용에 따른 철근콘크리트 초고층 건물에 대한 부등축소의 영향)

  • Kim, Gyeong-Chan;Kim, Jae-Yo
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.35 no.1
    • /
    • pp.35-44
    • /
    • 2022
  • It is essential to control the lateral displacement and differential axial shortening of the vertical elements in high-rise buildings. Recently, an outrigger or a mega structure system has been adopted to control the lateral displacement. Furthermore, to resolve the problems caused by differential axial shortening in high-rise buildings, analytical prediction and correction is often studied; however, the study on the comparisons of the lateral load resisting systems to address differential axial shortening is less. Therefore, in this paper, a 60-story RC residential building using an outrigger or a mega structure system is analyzed with a construction sequence. Moreover, differential axial shortening can result in an additional member force of structural members and failure of non-structural members. These problems caused by differential axial shortening affects the behaviors and can damage the important structure member in the high-rise buildings. Hence, the effects of the systems on differential axial shortening between the vertical elements in high-rise buildings are studied.

Pull-out Resistance Capacity Evaluation of Perfobond Rib Shear Connector (유공강판 전단연결재의 인발저항성능 평가)

  • Kim, Young-Ho;Koo, Hyun-Bon
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.28 no.6A
    • /
    • pp.853-859
    • /
    • 2008
  • As a new system of steel pipe pile cap reinforcement, the application of perforated flat bar bolted to the steel pipe pile head was suggested for the improvement of structural performance of footing structure. This study investigates the structural characteristics of perforated flat bar shear connectors according to shape and diameter of hole, number of rebars passing through the hole and the depth of settlement. The result shows several requirements to ensure sufficient pull-out resistance and ductility such as that the hole diameter excluding diameter of rebar should exceed the size of aggregates; the hole should be perforated with diameter as the half of plate height; and the adequate depth of settlement should be ensured for the optimal performance.

A Study on Topographic Effects in 2D Resistivity Survey by Numerical and Physical Scale Modeling (수치 및 축소모형실험에 의한 2차원 전기비저항 탐사에서의 지형효과에 관한 연구)

  • Kim Gun-Soo;Cho In-Ky;Kim Ki-Ju
    • Geophysics and Geophysical Exploration
    • /
    • v.6 no.4
    • /
    • pp.165-170
    • /
    • 2003
  • Recently, resistivity surveys have been frequently carried out over the irregular terrain such as mountainous area. Such an irregular terrain itself can produce significant anomalies which may lead to misinterpretations. In this study, topographic effects in resistivity survey were studied using the physical scale modeling as well as the numerical one adopting finite element method. The scale modeling was conducted at a pond, so that we could avoid the edge effect, the inherent problem of the scale modeling conducted in a water tank in laboratory. The modeling experiments for two topographic features, a ridge and a valley with various slope angles, confirmed that the results by the two different modeling techniques coincide with each other fairly well for all the terrain models. These experiments adopting dipole-dipole array showed the distinctive terrain effects, such that a ridge produces a high apparent resistivity anomaly at the ridge center flanked by zones of lower apparent resistivity. On the other hand, a valley produces the opposite anomaly pattern, a central low flanked by highs. As the slope of a terrain model becomes steeper, the terrain-induced anomalies become stronger, and moreover, apparent resistivity can become even negative for the model with extremely high slope angle. All the modeling results led us to the conclusion that terrain effects should be included in the numerical modeling and/or the inversion process to interpret data acquired at the rugged terrain area.

Finite Element Analysis of Piezocone Test II (피에조콘 시험의 유한요소 해석 II)

  • 김대규;김낙경
    • Journal of the Korean Geotechnical Society
    • /
    • v.16 no.4
    • /
    • pp.191-199
    • /
    • 2000
  • In this research, the finite element analysis of piezocone penetration and dissipation tests has been conducted using the anisotropic elastoplastic-viscoplastic bounding surface model, virtual work equation, and theory of mixtures formulated in the Up[dated Lagrangian reference frame for the large deformation and finite strain nature of piezocone penetration. The formulated equations have been implemented into a finite element program. The cone resistance, excess pore water pressure, and dissipation of excess pore water pressure from the finite element analysis have been compared and investigated. An effective simulation could be performed with the use of the anisotropic and viscous soil model. The finite element formulations and the results are described in part 'I' and part 'II' respectively.

  • PDF

Analysis of Ultimate Rockfall Energy Resistance of CFT Rock Shed Main Frame (CFT 피암터널 주구조체의 극한 낙석에너지 저항능력 분석)

  • Moon, Jiho;Lee, Juho;Song, Jong-Keol
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.34 no.3
    • /
    • pp.129-135
    • /
    • 2021
  • Rock sheds are a type of rockfall protection facility that is installed on the road near steep slopes, where large amount of rockfall is expected. Rock sheds are generally designed to resist approximately 200 kJ to 3,000 kJ of rockfall energy. In a previous study, a new type rock shed structure having a concrete-filled tube (CFT) main frame was proposed. By using CFT as the main frame in a rock shed, rapid construction is possible. Additionally, high load carrying capacity and ductility can be achieved. The behavior of the proposed rock shed structure was studied via elastic analysis with the equivalent static load of rockfall energy as in a previous study. However, it is necessary to investigate the behavior of the proposed rock shed in more detail with a full 3D finite element (FE) model considering realistic rockfall load. The FE model for the CFT rock shed main frame was developed first in this study. Then, the resistance of the CFT rock shed main frame Under ultimate rockfall energy was investigated.

Characteristic Analysis of Spiral Inductor Using Finite Element Method for RF IC's (유한 요소법을 이용한 마이크로파용 칩 인덕터의 특성 해석)

  • Hong, Sung-Ook;Lee, Joon-Ho;Lee, Se-Hee;Park, Il-Han
    • Proceedings of the KIEE Conference
    • /
    • 2003.10a
    • /
    • pp.276-278
    • /
    • 2003
  • 본 논문에서는 축대칭 유한요소법을 이용하여 고주파에서 사용하는 스파이럴 인덕터를 분석하였다. 스파이럴 인덕터는 고주파 운용시 인덕터 도체에서 발생하는 표피 효과와 근접 효과, 실리콘 기판의 전도성으로 인한 와전류에 의한 저항 손실, 그리고 대류 전류에 의한 기생 용량으로 인덕턴스의 감소와 같은 현상이 발생한다. 이러한 다양한 전자기적 기생 효과들이 실리콘 기판에서 스파이럴 인덕터의 성능을 저하시키게 된다. 그러므로 이러한 점들이 실리콘 기판에서 스파이럴 인덕터를 설계 및 모델링 함에 있어서 동기를 부여해 준다. 그래서 우리는 복잡한 형상에도 적용이 용이한 유한요소법을 이용하여 스파이럴 인덕터를 해석 및 설계하였다.

  • PDF

Modelling for Cyclic Behavior of the Panel Zone (패널 영역의 주기거동에 대한 모델링)

  • Kim, Kee Dong;Lee, Hak Eun;Ko, Man Gi;Kil, Heung Bae
    • Journal of Korean Society of Steel Construction
    • /
    • v.9 no.1 s.30
    • /
    • pp.139-147
    • /
    • 1997
  • 본 논문은 단조하중(monotonic loading)하의 강재 보-기둥의 절점의 패널 영역 거동을 연구한 논문(Kim 1997)의 후속 논문으로 주기하중에 대한 패널영역의 거동을 해석하기 위한 이력법칙(hysteretic rules)에 관한 것이다. 제안된 이력법칙은 실험결과와 합당한 상관관계를 보여주었고, 이 이력법칙을 사용한 패널영역요소의 해석 결과가 실험결과와 잘 일치하는 것으로 나타났다. 한편 보강판(a doubler plate)을 갖는 패널영역에 대한 해석과 실험결과로 부터 보강판이 패널영역전달력 (panel zone shear force)을 저항하는데 있어 부분적인 효과만 있다는 것을 알 수 있었다. 제안된 패널영역요소는 구조물의 전체 거동과 국부 변형을 기존의 패널영역요소(bilinear panel zone element)보다 정확하게 예측 할 수 있었다.

  • PDF