• Title/Summary/Keyword: 저항 시험

Search Result 2,143, Processing Time 0.029 seconds

Development of Engineered Wood using Mechanical Jointing Methods with Large Elements (대형요소의 기계적 접합법을 이용한 공학목재 개발)

  • Park, Joo-Saeng;Shim, Kug-Bo;Kim, Kwang-Mo;Park, Moon-Jae;Cho, Sung-Taig;Kim, Wae-Jung
    • Journal of Korea Foresty Energy
    • /
    • v.25 no.2
    • /
    • pp.34-41
    • /
    • 2006
  • In this study, new engineered woods, which can be used as structural members, are developed using three different mechanical jointing methods with large elements produced from logs in a high yield. Flitches of relatively large cross-section are produced from small or medium diameter logs, and are joined with steel bolts, wood dowesl and steel lag bolts. Static bending tests are performed for these three types of built-up beams. Built-up beams joined with steel bolts show $514kgf/cm^2$ for MOR and $129,000kgf/cm^2$ for MOE, which are close to those of typical structural glulams. In case that wood dowels and steel lag bolts are used, elements are isolated as load increases and resists the applied load individually. Therefore, built-up beams joined with wood dowels or steel lag bolts show almost half of steel bolts for both MOE and MOR. From the results of this study, it was indicated that bending properties of engineered woods manufactured using mechanical jointing methods with large elements are influenced mainly by jointing performance between each elements.

  • PDF

MECHANICAL AND HISTOMORPHOLOGIC CHANGES OF THE RAT FEMUR AFTER ADMINISTRATION OF SODIUM FLUORIDE (불화물에 의한 백서 대퇴골의 강도 및 조직형태학적인 변화)

  • Lee, Soo-Koung;Song, Keun-Bae;Jang, Hyun-Jung
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.26 no.4
    • /
    • pp.363-368
    • /
    • 2000
  • The purposes of the study was to examine changes in thickness and strength of the rat femur after administration of sodium fluoride in the drinking water. 48 female Sprague-Dawley rats were randomly divided into 4 groups, and they were supplied with 0(control), 1, 5 and 50 ppm of fluoride in the drinking water ad libitum for 6 weeks. Rats were killed and both sides of femur were dissected. Bone strength was measured as the stress of failure of femur at the middle point and femoral neck with Instron. Histologic slides were prepared from the femur shaft with routine processing of fixing, demineralizing, embedding and HE staining. Thickness and area of cortical bone and medullary cavity were measured by using Camera Lucida and Image Analyzer. All the collected data were analyzed with one-way ANOVA, Duncan's multiple range test for post-hoc tests and ANCOVA using the SAS 6.12 package at the level of 0.05. Bone strength increased significantly in the animals given 1 and 5 ppm of fluoride in the water, as compared to the control group. There were significant decreases of stress at fracture in 50 ppmF group compared to the 1 and 5 ppmF groups. The similar trends of bone strength at the femoral neck fracture test, but there were no statistical significances. Cortical bone thickness and area of the femur increased in the 1 and 5 ppmF groups compared to the control. However, the thickness of 50 ppmF group also decreased significantly as compared to 1 and 5 ppmF groups. On the other hand, medullary thickness and area increased in all fluoride groups than control group. All of the findings presented support the conclusion that, low fluoride dosage used in water fluoridation could increase the bone strength and might have preventive effect on femur fracture.

  • PDF

Development and Uncertainty Assessment of Interface Friction Prediction Equation Between Steel Surface and Cohesionless Soils (강재면과 사질토 사이의 경계면 마찰각 예측식 개발 및 불확실성 평가)

  • Lee, Kicheol;Kim, So-Yeun;Kim, Dongwook
    • Journal of the Korean Geosynthetics Society
    • /
    • v.17 no.2
    • /
    • pp.33-40
    • /
    • 2018
  • Characteristics of interface friction between cohesionless soils and geotechnical structure surfaces play an important role in the analysis of earth load and resistance on the structure. In general, geotechnical structures are mainly composed of either steel or concrete, and their surface roughnesses with respect to soil particle sizes influence the interface characteristics between soils and the structures. Accurate assessment of the interface friction characteristics between soils and structures is important to ensure the safety of geotechnical structures, such as mechanically stabilized earth walls reinforced with inextensible reinforcements, piles embedded into soils, retaining wall backfilled with soils. In this study, based on the database of high quality interface friction tests between frictional soils and solid surfaces from literature, equation representing peak interface friction angle is proposed. The influential factors of the peak interface friction angle are relative roughness between soil and solid surface, relative density of frictional soil, and residual (constant volume) interface friction angle. Futhermore, for the developed equation of the interface friction angle, its uncertainty was assessed statistically based on Goodness-of-fit test results.

Effect of Fluorine-Silicate Hybrid Based Crack Reducing Agent on the Resistance for Shrinkage Crack and Gas Permeability of Concrete (불소-실리카 복합형 균열저감제가 콘크리트의 수축균열 저항성 및 투기성에 미치는 영향)

  • Lee, Man-Ik;Park, Jong-Hwa;Nam, Jae-Hyun;Kim, Do-Su;Kim, Jae-On
    • Journal of the Korea Concrete Institute
    • /
    • v.18 no.5 s.95
    • /
    • pp.631-637
    • /
    • 2006
  • In this study, fundamental properties such as fresh and hardened performance of concrete mix(specification : 25-24-18) added fluorine-silicate hybrid based crack reducing agent(FS) were measured. Addition of FS ranged from 0.5% to 2.0% at intervals 0.5% based on cement weight. Adequate dosage(0.5%) of FS derived from basic properties measurements applied and compared resistance for shrinkage crack. The permeability of concrete in the absence(24-S-0.0) and presence(24-S-0.5) of evaluated at a mock-up sized concrete. Concrete added FS improved resistance for shrinkage crack and consequently crack number, length and area decreased to $50{\sim}74.4%$ compared non-added. As well, by the addition of FS, the resistance for permeability and penetration depth to concrete surface region increased 67% and 40%, respectively. Therefore it was confirmed that shrinkage crack resistance and permeability of concrete could be improved by the addition of FS.

Flexural and Impact Resisting Performance of HPFRCCs Using Hybrid PVA Fibers (하이브리드 PVA 섬유를 이용한 HPFRCCs의 휨 및 충격 성능 평가)

  • Kim, Young-Woo;Min, Kyung-Hwan;Yang, Jun-Mo;Yoon, Young-Soo
    • Journal of the Korea Concrete Institute
    • /
    • v.21 no.6
    • /
    • pp.705-712
    • /
    • 2009
  • HPFRCCs (high-performance fiber reinforced cementitious composites), which is relatively more ductile and has the characteristic of high toughness with high fiber volume fractions, can be used in structures subjected to extreme loads and exposed to durability problems. In the case of PVA (polyvinyl alcohol) fiber, it is noted by former studies that around 2% fiber volume fractions contributes to the most effective performance at HPFRCCs. In this study, flexural tests were carried out to evaluate the flexural behavior of HPFRCCs and to optimize mix proportions. Two sets of hybrid fiber reinforced high performance specimens with total fiber volume fraction of 2 % were tested: the first set prepared by addition of short and long PVA fibers at different combination of fiber volume fractions, and the second set by addition of steel. In addition, in order to assess the performances of the HPFRCCs against to high strain rates, drop weight tests were conducted. Lastly, the sprayed FRP was applied on the bottom surface of specimens to compare their impact responses with non-reinforcing specimens. The experimental results showed that the specimen prepared with 1.6% short fibers (REC 15) and 0.4% long fiber (RF4000) outperformed the other specimens under flexure, and impact loading.

Oxygen Permeation and Syngas Production of La0.7Sr0.3Ga0.6Fe0.4O Oxygen Permeable Membrane (La0.7Sr0.3Ga0.6Fe0.4O 분리막의 산소투과특성 및 합성가스의 생성)

  • 이시우;이승영;이기성;정경원;김도경;우상국
    • Journal of the Korean Ceramic Society
    • /
    • v.40 no.6
    • /
    • pp.594-600
    • /
    • 2003
  • L $a_{0.7}$S $r_{0.3}$G $a_{0.6}$F $e_{0.4}$ $O_{3-}$$\delta$/ perovskite-type mixed conducting membranes, which could permeate oxygen selectively, have been fabricated and the microstructural features developed by varying the sintering conditions have been analyzed. The effects of surface modification and the membrane thickness on oxygen permeability have been evaluated under He/air environment. With increasing a grain boundary fraction, the overall oxygen permeability decreased. The syngas (CO+ $H_2$) has been produced by partial oxidation reaction of methane with the oxygen permeated through the membrane. Methane conversion and syngas yield have been evaluated as functions of the compositional ratio of feed gas and reaction temperature. In long-term duration test for 600 h, under C $H_4$+He/air environment, L $a_{0.7}$S $r_{0.3}$G $a_{0.6}$F $e_{0.4}$ $O_{3-}$$\delta$/ membrane showed a highly stable performance.

CGMMV Tolerance Test of CGMMV-CP Trangenic Watermelon Rootstock and Establishment of Transgenic Line (CGMMV-CP 형질전환 수박대목의 CGMMV 내성시험 및 계통확보)

  • Park, Sang-Mi;Kwon, Jung-Hee;Lim, Mi-Young;Shin, Yoon-Sup;Her, Nam-Han;Lee, Jang-Ha;Ryu, Ki-Hyun;Harn, Chee-Hark
    • Journal of Plant Biotechnology
    • /
    • v.34 no.1
    • /
    • pp.11-17
    • /
    • 2007
  • Previously developed transgenic watermelon rootstocks (gongdae) inserted by CGMMV-CP were examined to test the virus tolerance levels. In the restricted plastic house, the $T_{3}$ watermelon rootstock showed tolerance to CGMMV until 70 days after inoculation on the leaves while the non-transformed watermelon rootstock became susceptible at 20 days after inoculation. In the field, tolerance efficiency of transgenic rootstocks maintained up to 40% at 71 days after contamination with CGMMV in the soil while all of the non-transformed rootstocks became susceptible at 37 days with the same condition. In the same field, transgenic rootstocks showed more tolerance to CGMMV than the non-transformed rootstocks as those were inoculated on the leaves, but it showed only 10 days delay before being susceptible. Therefore, transgenic rootstocks have a characteristic of delay effect against CGMMV susceptibility, rather than resistance character. From $T_{3}$ rootstocks homozygous for the CGMMV-CP horticulturally favorable individuals were selected for further breeding and a transgenic line was finally obtained at the $BC_{1}T_{5}$. A material transfer experiment was conducted to find out if the DNA, RNA or expressed protein in the transgenic rootstocks could move to the grafted scion (non-transformed watermelon, Super-Kumcheon). PCR, northern, and western blot analysis were performed and no evidence of transferring of those materials from rootstock to scion was ever found.

Precise Detection of Buried Underground Utilities by Non-destructive Electromagnetic Survey (비파괴 전자탐사에 의한 지하 매설물의 정밀탐지)

  • Shon, Ho-Woong;Lee, Seung-Hee;Lee, Kang-Won
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.22 no.3
    • /
    • pp.275-283
    • /
    • 2002
  • To detect the position and depth of buried underground utilities, method of Ground Penetrating Radar(GPR) survey is the most commonly used. However, the skin-depth of GPR is very shallow, and in the places where subsurface materials are not homogeneous and are compose of clays and/or salts and gravels, GPR method has limitations in application and interpretation. The aim of this study is to overcome these limitations of GPR survey. For this purpose the site where the GPR survey is unsuccessful to detect the underground big pipes is selected, and soil tests were conducted to confirm the reason why GPR method was not applicable. Non-destructive high-frequency electromagnetic (HFEM) survey was newly developed and was applied in the study area to prove the effectiveness of this new technique. The frequency ranges $2kHz{\sim}4MHz$ and the skin depth is about 30m. The HFEM measures the electric field and magnetic field perpendicular to each other to get the impedance from which vertical electric resistivity distribution at the measured point can be deduced. By adopting the capacitive coupled electrodes, it can make the measuring time shorter, and can be applied to the places covered by asphalt an and/or concrete. In addition to the above mentioned advantages, noise due to high-voltage power line is much reduced by stacking the signals. As a result, the HFEM was successful in detecting the buried underground objects. Therefore this method is a promising new technique that can be applied in the lots of fields, such as geotechnical and archaeological surveys.

Analysis Method for Damage Patterns of Low Voltage Switches for PL Judgment (PL 판정을 위한 저압용 스위치의 소손 패턴 해석기법)

  • Choi, Chung-Seog
    • Fire Science and Engineering
    • /
    • v.24 no.5
    • /
    • pp.136-141
    • /
    • 2010
  • The purpose of this study is to examine the structure and heat generation mechanism of low voltage switches used to turn on or off the power supply to an indoor lighting system and investigate how the fixtures and movable contacts of the switches are damaged depending on the types of energy sources in order to secure the judgment base for expected PL disputes. Based on the Korean Standard (KS) testing method for incombustibility, this study applied a general flame to the switch. In addition, current was supplied to the switch using the PCITS (Primary Current Injection Test System). The ambient temperature and humidity were maintained at $22{\pm}2^{\circ}C$ and 40~60% respectively while performing the test. It is thought that the switch generated heat due to a defective connection of the wire and clip, insulation deterioration and defective contact of the movable contact, etc. The surface of the switch damaged by the general flame was uniformly carbonized. When the flame source was removed, the fire on the switch was extinguished naturally. From the result obtained by disassembling the switch carbonized by the general flame, it could be seen that fixtures and movable contacts remained in comparatively good shape but the enclosure, clip support, movable contact, indicating lamp, etc. showed carbonization and discoloration. In the case of the switch damaged by overcurrent, the clip connecting the wires, clip support, etc. showed almost no trace of damage, but the fixtures, movable contact, indicating lamp, etc. were severely carbonized. That is, the sections with high contact resistance were intensively damaged and showed a damage pattern indicating that carbonization progressed from the inside to the outside. Therefore, it is possible to judge the initial energy source by analyzing the characteristics of the carbonization pattern and the metal fixtures of damaged switches.

Effect of Post-annealing on the Interfacial adhesion Energy of Cu thin Film and ALD Ru Diffusion Barrier Layer (후속 열처리에 따른 Cu 박막과 ALD Ru 확산방지층의 계면접착에너지 평가)

  • Jeong, Minsu;Lee, Hyeonchul;Bae, Byung-Hyun;Son, Kirak;Kim, Gahui;Lee, Seung-Joon;Kim, Soo-Hyun;Park, Young-Bae
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.25 no.3
    • /
    • pp.7-12
    • /
    • 2018
  • The effects of Ru deposition temperature and post-annealing conditions on the interfacial adhesion energies of atomic layer deposited (ALD) Ru diffusion barrier layer and Cu thin films for the advanced Cu interconnects applications were systematically investigated. The initial interfacial adhesion energies were 8.55, 9.37, $8.96J/m^2$ for the sample deposited at 225, 270, and $310^{\circ}C$, respectively, which are closely related to the similar microstructures and resistivities of Ru films for ALD Ru deposition temperature variations. And the interfacial adhesion energies showed the relatively stable high values over $7.59J/m^2$ until 250h during post-annealing at $200^{\circ}C$, while dramatically decreased to $1.40J/m^2$ after 500 h. The X-ray photoelectron spectroscopy Cu 2p peak separation analysis showed that there exists good correlation between the interfacial adhesion energy and the interfacial CuO formation. Therefore, ALD Ru seems to be a promising diffusion barrier candidate with reliable interfacial reliability for advanced Cu interconnects.