• Title/Summary/Keyword: 저항성 누설전류

Search Result 63, Processing Time 0.017 seconds

Development of the Leakage Current Detection Module for a Concent (콘센트용 누전감지 모듈 개발)

  • Han, Young-Oh
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.8 no.3
    • /
    • pp.447-452
    • /
    • 2013
  • In this paper, the leakage current detection and auto shut-off module for a concent has been developed. Existing leakage current detection modules are detecting resistive leakage current, using a resistive leakage current detection chip but the proposed leakage current detection module separates and detects resistive leakage current in the synthesis leakage current by only programming in a power processor MCU(MSP430). The module implemented by proposed method has early detection and auto shut-off feature at more than resistive leakage current 5mA, and has the advantage of easily adjusting resistive leakage current less or more than 5mA, because of resistive leakage current detection function being implemented by a program in MCU.

The Implementation of Active Leakage Current Detecting Algorithm based on 16 bit Signal Processor (16비트 신호처리 프로세서 기반 유효성분 누설전류 감지 알고리즘 구현)

  • Han, Young-Oh
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.11 no.6
    • /
    • pp.605-610
    • /
    • 2016
  • The ELCB(: Earth Leakage Circuit Breaker) is the only way being used to prevent accidents from happening caused by electrical disaster. However, the existing ELCB has a limit to prevent damages to life and property due to a electric fire and a human body electric shock caused by the resistive leakage current, because of detecting the total leakage current in the block range of 15mA~30mA. It also has problems such as reduced productivity and reliability due to malfunctions by capacitive leakage currents. In this study, we have implemented the algorithm for the resistive leakage current detection technique and developed the resistive leakage current detection module based on a MSP430 processor, 16bit signal processor and this module can be operated in a desired block threshold within 0.03 seconds as specified in KS C 4613.

A Development of Resistive Leakage Current detecting circuit with Voltage Phase Comparison (전압 위상 비교에 의한 저항성 누설 전류 검출 회로 개발)

  • Joo, Nam-Kyu;Kim, Tae-Wan;Lim, Youg-Bae
    • Proceedings of the KIEE Conference
    • /
    • 2009.04a
    • /
    • pp.172-173
    • /
    • 2009
  • 최근의 가정용 전기 설비의 경우 다양화, 첨단화 되면서 과거에는 예상치 못했던 재해들이 발생하여 기존의 설비에 영향을 주는 경우가 생겨난다. 특히 누전 차단기의 경우 고조파, 대지 정전용량 등에 의하여 오동작 요소로 작용하고 있으며, 이를 해결하기 위한 방법으로 저항성 누설 전류에 대한 분석이 필요하며 이를 위하여 전압 위상과 전류 위상, 누설 전류 위상을 검출하여 비교함으로써 순수 저항성 누설 전류와 용량성 누설전류에 대한 분석을 검출 모니터링하여 비전문가 집단인 수용가 특히 가정에서 보다 안전한 전기사용과 관리에 활용 하고자한다.

  • PDF

Development of Guard Lamp Remote Inspecion System Using Resistive Leakage Current Detecting (저항성 누설전류 검출방식을 이용한 보안등 전기설비 원격점검 시스템 개발)

  • Choi, Myeong-Il;Yoo, Jae-Geun;Jeon, Jeong-Chay;Bae, Suk-Myeong
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.10
    • /
    • pp.81-89
    • /
    • 2009
  • Recently, Guard lamp was divided from electric facilities for general use as dangerous zone of safety management. This paper presents a remote inspection system of guard lamp that can monitor electrical safety factor. Especially, the developed system adopts the measurement algorithm for detecting resistive leakage current($I_{gr}$) flowing based on the phase difference checkable for sensing at a monitor. Also, It was fabricated the repeater for data transmission and the MMI program At this system, we made experiment on stability of resistive leakage current to verify phase comparison detecting algorism.

Study on Leakage Current and Insulation Resistance Effect of Temperature and Humidity (온도, 습도의 누설전류와 절연저항 영향 연구)

  • Han, Kyung-Chul;Choi, Yong-Sung
    • Journal of IKEEE
    • /
    • v.23 no.2
    • /
    • pp.370-374
    • /
    • 2019
  • It was found that temperature and humidity did not affect the leakage current since the leakage current was irregularly increased or decreased at a temperature of $22^{\circ}C$ to $32^{\circ}C$ and a humidity of 60.0% to 96.0%. The insulation resistance in the vicinity of $26^{\circ}C$ was $10.70M{\Omega}$ to $4,000.00M{\Omega}$ and was low from $9.10M{\Omega}$ to $1,000.00M{\Omega}$ before and after $26^{\circ}C$. As the humidity was increase in a range of 60%~96%, the insulation resistance was reduced from $4,000.00M{\Omega}$ to $4.80M{\Omega}$, which indicates that the temperature and humidity had an influence on the insulation resistance. The leakage current and the insulation resistance of the branch circuit to the cooking facilities were compliant with less than 1.00 mA and more than $0.20M{\Omega}$. Leakage current of 1.89 mA was non-compliant but the insulation resistance was compliant with the value of $65.00M{\Omega}$.

Study on Characteristics of Leakage Current and Insulation Resistance for a Circuit According to Load Types (부하종류에 따른 회로의 누설전류 및 절연저항 특성 연구)

  • Han, Kyung-Chul;Choi, Yong-Sung
    • Journal of IKEEE
    • /
    • v.23 no.2
    • /
    • pp.364-369
    • /
    • 2019
  • The ratios of compliant branch circuit of leakage current and insulation resistance were 68.4% and 90.8%, respectively at the lamp load, 64.6% and 96.5% at the heat load, 86.7% and 88.9% at the power load. Limit of residual current of the zero phase secondary current value at the zero phase primary current was 100 A when rated primary current 400 A more than. The reason why the ratio of branch circuit of the leakage current was less than the ratio of compliant branch circuit of the insulation resistance might be that the leakage current includes the capacitive leakage current and the zero phase current.

The Development of Resistive Leakage Current Circuit Breaker using a ARM Processor (ARM 프로세서를 이용한 저항성 누전 차단기 개발)

  • Lee, Hyun-Do
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.12 no.4
    • /
    • pp.615-620
    • /
    • 2017
  • In this study, we have developed the resistive leakage current detecting and tripping circuit breaker based on a 32bit ARM processor. The developed leakage circuit breaker can be operated in a desired trip threshold within 0.03 seconds as specified in KS C 4613. This resistive leakage current breaker is expected to be applicable as a circuit breake for prevention of electric fires and electric shock in smart distribution panel.

A Detection Method of Resistive Leakage Current Flowing through ZnO Arrester Blocks (산화아연 피뢰기소자에 흐르는 저항분 누설전류의 검출기법)

  • 이복희;강성만
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.15 no.3
    • /
    • pp.67-73
    • /
    • 2001
  • This paper resents a developed measuring device of resistive leakage current and a fundamental discussion of deterioration diagnosis for Zinc Oxide(ZnO) arrester blocks. We have developed the leakage current detection device for ageing test and durability evaluation for ZnO arrester blocks. The resistive leakage current can be used as an indicator to discriminate whether the ZnO arrester blocks is in good state or in bad. The resistive leakage current measuring system with the compensation circuit was designed and fabricated. The sauce tests for ZnO arrester blocks were investigated by observing the resistive leakage current together with fast Fourier transform analysis. The proposed monitoring systems for the resistive leakage current can effectively be used to investigate the electrophysical properties of ZnO arrester blocks in laboratory and to develop the techniques of forecasting the deterioration of ZnO arresters in electric power systems.

  • PDF

Development of mA Level Active Leakage Current Detecting Module (mA급 유효성분 누설전류 감지 모듈 개발)

  • Han, Young-Oh
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.12 no.1
    • /
    • pp.109-114
    • /
    • 2017
  • In this study, we have developed the active leakage current detection module based on a MSP430 processor, 16bit signal processor. This module can be operated in a desired trip threshold within 0.03 seconds as specified in KS C 4613. This developed module is expected to be applicable as a module for prevention of electric shock in smart distribution panel of smart grid.

Evaluation of Rail Leakage Current and Potential in DC Railway (직류철도의 레일누설전류 밑 전위평가)

  • Han, Moon-Seob;Jung, Ho-Sung;Kim, Ju-Rak;Kil, Gyung-Suk
    • Journal of the Korean Society for Railway
    • /
    • v.12 no.1
    • /
    • pp.161-166
    • /
    • 2009
  • DC feeding system is mainly floating but rail potential and leakage current are due to long parallelism between rails and ground, namely rail resistance and rail to ground conductance. Rail potential causes electric shock to human and rail leakage current causes electrolytic corrosion to nearby the buried metals. Therefore the design technologies to reduce, protect and monitor these effects are important in recent DC feeding system. Rail potential and leakage current are analysed based on propagation theory that is utilized. Monitoring and controlling rail leakage current is proposed in order to maintain rail resistance and rail to ground conductance.