• Title/Summary/Keyword: 저주파 진동

Search Result 193, Processing Time 0.037 seconds

Low Frequency Noise of Daejeon Subway (대전 지하철 저주파 소음)

  • Jung, Sung-Soo;Suh, Sang-Joon;Seo, Jae-Gap;Jeon, Byeong-Su
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.05a
    • /
    • pp.887-890
    • /
    • 2007
  • The low frequency noise, including infra-sound is known to affect human physiology and psychology. Guidelines and measurement method of low frequency noise has been introduced in several countries in order to evaluate low frequency noise. In this work, low frequency characteristics of Daejeon subway was investigated in terms of the noise level and spectrum in the interior of running subway car and the subway station. The interior sound pressure level of the passenger car was between 60 and 102 dB in the frequency range of $1{\sim}250$ Hz.

  • PDF

The Study on Noise Reduction of a Industrial stack (산업용 Stack의 방음대책에 대한 연구)

  • Oh, Jin-Woo;Kwon, Byoung-Ha;Lee, Jang-Hyun;Lee, Hyo-Haeng;Lee, Kyu-Hyung
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.462-467
    • /
    • 2008
  • 산업용 Stack은 높은 위치의 지리적 특징과 낮은 주파수의 음향특성으로 인해 발생소음도 자체를 감소시키는 것이 무엇보다 중요하다. 대표적인 방음대책은 소음기가 있으나 규모가 크고 테스트를 위한 경제적인 부담이 크므로 이론적, 해석적인 검토를 통해 Stack 소음기의 형태를 선정하고 실제 적용 현장에서의 소음기 성능을 측정하여 예측결과를 평가하였다. 산업용 Stack 소음기의 경우 소음기의 구조에 대한 문제 및 저주파 성분이 높은 Stack 소음 특성을 고려하여 조건에 적합한 +형 스프리터 소음기를 설계, 적용하였다. 현장측정결과 문제대역인 저주파 대역에서 뚜렷한 소음감소를 나타내는 것을 알 수 있었다.

  • PDF

A Real Time Parameter Estimation of Low Frequency Oscillation in Discrete Signal Part II : Application (이산신호에서 실시간 저주파 진동 파라미터 추정 Part II : 응용)

  • Kim, Eui-Sun;Shim, Kwan-Shik;Moon, Chae-Joo
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.219-220
    • /
    • 2008
  • 이 논문은 이산푸리에변환을 이용하여 시계열데이터에 포함되어 있는 파라미터를 추정하는 새로운 방법과 그 응용 결과를 기술하고 있다. 제안한 방법은 푸리에스펙트럼으로부터 직접 파라미터를 추정하는 방법으로 FFT의 장점을 이용할 수 있으므로 신호에 포함되어 있는 중요 주파수를 비롯한 저주파 진동 파라미터를 빠르게 추정할 수 있다. 이 논문에서는 단순한 산술계산만 수행하여 제동계수를 추정할 수 있도록 알고리즘을 단순화하였다. 그리고 WSCC 계통에서 실측한 데이터에 제안한 알고리즘을 적용하여 효율성을 검증하였다.

  • PDF

Low Frequency Pass-by Noise for Road Vehicle (도로교통 소음원에 의한 저주파 소음실태)

  • 정성수;서상준;조문재;김용태
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.11a
    • /
    • pp.533-536
    • /
    • 2003
  • The Low frequency(1-200 Hz) noise levels radiated by road traffic were investigated. The results showed that the peak pass-by noise of truck with speed of 60km/h was about 75㏈. For the infra-sound frequency range, the noise was about 65㏈ and it was less value than expected. But the noise level will be increase as increasing the speed. The pass-by noise for train was also measured for comparison. The peak train noise was about 95㏈ and it will be enough noise level for a human body to give nuisance.

  • PDF

Development and Test of a Tile Projector for Control of Low-frequency Underwater Echoes (저주파 수중 반향음 제어를 위한 타일형 프로젝터의 개발 및 성능시험)

  • Woo, Sangbeom;Lee, Jae-Wan;Ohm, Won-Suk;Kim, Wan-Gu;Kang, Hwi-Suk;Yoon, Suk Wang;Seo, Youngsoo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2014.10a
    • /
    • pp.630-634
    • /
    • 2014
  • In this paper, a tile projector was developed for the control of low-frequency underwater echoes. The projector was designed to cover a wide area such as the hull of a submarine, and to have a relatively thin thickness. As a preliminary work for active echo control, the performance of the projector was measured in an anechoic water tank. The transmitting voltage response as well as the passive echo reduction were measured to evaluate the performance as an underwater projector.

  • PDF

Finite Element Analysis of a Tile Projector for Control of Low-frequency Underwater Echoes (저주파 수중 반향음 제어를 위한 타일형 프로젝터의 유한요소 해석)

  • Lee, Jae-Wan;Woo, Sangbeom;Ohm, Won-Suk;Seo, Youngsoo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2014.10a
    • /
    • pp.625-629
    • /
    • 2014
  • In this paper, a tile projector for the active control of low-frequency underwater echoes is studied using finite element method. Compared to the existing underwater actuators used for echo reduction, the tile projector is better suited for covering a wide area such as the hull of a submarine. In order to actively match the acoustic impedance at the water-object interface, the projector is driven to radiate a pressure wave that is the inverted replica of the echo at the interface. Finite element simulations demonstrate significant echo reductions due to the active impedance matching by the tile projector.

  • PDF

Analysis of the Factors Affecting Low-Frequency Oscillations in KEPCO Power System` With Pumped-Storage Plant (한전 전력계통의 저주파 진동현상 요인분석;양수발전기 기동시)

  • Kil Yeong Song;Sae Hyuk Kwon;Kyu Min Ro;Seok Ha Song
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.41 no.8
    • /
    • pp.841-849
    • /
    • 1992
  • In power system operation, the stability of synchronous machine has been recognized one of the most important things. AESOPS program developed by EPRI in U.S.A. is a frequency domain analysis program in power system stability and it computes the electro-mechanical oscillation mode. This paper presents how to analyze the power system small signal stability problem efficiently by uusing the AESOPS program and analyze the various factors affecting the damping characteristics of these oscillations in KEPCO power system of 1986 with pumped-storage plant. To reduce the computing time and efforts, selecting the poorly-damped oscillation mode and clustering technique have been used. The characteristics of load, the amount of power flow on the transmission line and the gain of exciter have a significant effects on the damping of the system while the governing system has only a minor one. With the Power System Stabilizers, the stability of the power system has been improved.

  • PDF

A Study on the Tool Vibration Measurement Using the Fiber Optic Interferometric Sensor in Lathe Cutting Process (광섬유 간섭계 센서를 이용한 선삭가공 공구진동 측정 연구)

  • Lee, Jongkil
    • 대한공업교육학회지
    • /
    • v.32 no.2
    • /
    • pp.171-187
    • /
    • 2007
  • The purpose of this study is to measure the lathe tool vibration and verify its usefulness using the fiber optic interferometeric sensor instead of using common accelerometer. To compare two vibration signals a Fabry-Perot fiber optic sensor(FOS) is directly attached to the left-side surface of the lathe tool and an accelerometer is attached near to the fiber optic sensor. Measurement signals from the FOS and theoretical results of receptance simulation are compared. When the amplitude of tool vibration increased the frequency shift phenomena was occurred. This means that mass effect occurred and vibration spectrum moved to the low frequency region. Generally this results is agreement to the regenerative chatter. The chatter frequency is not same as the natural frequency of the tool itself. The FOS can also applied to laboratory experiments for students. This experimental technique is perhaps the first attempts because of directly attachment technique. Therefore, suggested Fabry-Perot fiber optic sensor can be used to monitoring the tool wear and vibration.

Analysis of Ground Vibration Characteristics by Test Blasting in Southern Region of Jeju (제주 남부지역의 시험발파에 의한 지반진동 특성 분석)

  • Kim, Seung Hyun;Lee, Dong Wook
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.39 no.3
    • /
    • pp.419-429
    • /
    • 2019
  • The characteristics of ground vibration have been analyzed by test blasting in southern region of Jeju (layered ground consisting of basalt and clinker). By grasping the principal component of ground vibration and depriving the prediction equations of ground vibration, the propagation characteristics of ground vibration have been compared to the domestic design guidelines. Ground vibration in layered ground has a small amplitude at a short distance. However, it has been confirmed that the vibration energy is transmitted further by virtue of the low attenuation of the ground vibration as it goes to a longer distance. Moreover, the frequency has been confirmed to be low frequency band. The outcome has been defined that it resulted because the clinker layer with a large pore transforms the blasting energy seismic wave with high frequency into a low frequency wave having a long waveform period. In addition, the limits of design guidelines were identified by comparing the ground vibration of Jeju and other bedrock areas. Thus, the necessity of the development of the prediction equations of ground vibration utilized in design that reflect the characteristics of the area has been suggested.

Ignition Test of an Oxidizer Rich Preburner (산화제과잉 예연소기 점화시험)

  • Moon, Il-Yoon;Moon, In-Sang;Yoo, Jae-Han;Jeon, Jae-Hyoung;Lee, Seon-Mi;Hong, Moon-Geun;Ha, Seong-Up;Kang, Sang-Hun;Lee, Soo-Young
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2011.11a
    • /
    • pp.869-872
    • /
    • 2011
  • Ignition tests of an oxidizer rich preburner for a staged combustion cycle liquid rocket engine were performed to evaluate combustion performance. Design operation conditions of the tested oxidizer rich preburner are about 60 of OF ratio and 20 MPa of combustion pressure. The entire kerosene and some LOx injected into the mixing head is burned in combustion chamber and the remaining LOx injected through center holes of combustion chamber is vaporized. Full flow ignition method with hypergolic fuel was used. Each propellant was supplied in two stages for soft ignition. Test results, low frequency oscillation was occurred in low flow rate conditions under 45% of design flow rate. Stable ignition in the course of design combustion pressure was able to induce by minimization of low flow rate ignition region to escape low frequency oscillation.

  • PDF