• Title/Summary/Keyword: 저온검출기

Search Result 62, Processing Time 0.023 seconds

Analysis of Trace Impurities in The Bulk Gases by a Cold Concentration Method (저온 농축법에 의한 극미량 성분 가스분석)

  • Lee Taeck-Hong;Hong So Young;Jung Woo Chan;Kim Young Rak;Suh Jung Woo;Han Ju Tack;Park Doo Seon;Son Moo Ryong
    • 한국가스학회:학술대회논문집
    • /
    • 1997.09a
    • /
    • pp.260-265
    • /
    • 1997
  • Analysis of trace impurities in the bulk .gas has been very important with the development of semi-conductor related industry. In the paper, we reported the analysis of the trace impurites of carbon monoxide and methane in the bulk helium and hydrogen by the GC-TCD with a cold nitrogen trap. We compared these results by the paraallel analysis. All data showed a good correspondence, showing reliable statistical error ranges.

  • PDF

키토산 및 칼슘 처리가 월동온주밀감의 저장기간에 따른 품질변화

  • 김성학;고정삼;김봉찬;양영택;한원탁
    • Proceedings of the Korean Society of Postharvest Science and Technology of Agricultural Products Conference
    • /
    • 2003.10a
    • /
    • pp.186.1-186
    • /
    • 2003
  • 온주밀감의 당도를 높이고 신선도를 유지하기 위하여 무가온 비닐하우스에서 이듬해 2-4월에 수확하는 월동감귤은 부피과의 발생이 쉽고 저장성이 나빠 수확시기에 바로 출하하는 감귤을 제외하고는 저온저장이 필수적이다. 2월 하순에 수확한 월동감귤(궁천조생)을 저장 전에 키토산과 칼슘처리를 하고 저장에 미치는 영향을 검토하였다. 부패과 발생은 저장 30일부터 나타났고, 무처리에서는 그 이후 부패가 빠르게 진행되었다. 그러나 베푸란 또는 키토산과 칼슘 처리에서는 저장 60일까지 부패과의 발생을 억제할 수 있어서, 이 기간까지가 저장이 가능한 기간으로 보인다. 중량감소는 11월 하순에 수확한 궁천조생에 비하여 모든 처리에서 중량감소가 빠르게 진행되었다. 유리당은 11월에 수확한 궁천조생과 비교하였을 때 glucose은 비슷하였으나, sucrose, fructose은 다소 많은 양이 검출되었다. 유기산은 citric acid과 malic acid 2종류가 검출되었으며, 그 함량도 관행수확기에 수확한 감귤보다 citric acid는 1/2 이하로 낮게 나타났고, malic acid는 비슷한 함량이 나타났다. 저장기간이 경과함에 따라 유기산 함량은 서서히 감소하였으나, malic acid은 초기에 감소되었으나 3월 중순이후에는 일정한 수준을 나타났다. 유리아미노산의 함량은 11월에 수확한 궁천조생에 비하여 D,L-$\alpha$-aminoadipic acid, $\alpha$-amino- $\beta$-guanidinopropionic acid 등 2종을 제외한 27종이 검출되었다.

  • PDF

Comparative Characterization of the Bacteria Isolated from Market Milk Treated with ESL and Conventional System (ESL 생산공정에 따른 시유 유래 미생물의 분포 비교 연구)

  • 김응률;정병문;유병희;정후길;강국희;전호남
    • Food Science of Animal Resources
    • /
    • v.23 no.4
    • /
    • pp.327-332
    • /
    • 2003
  • This study was conducted to investigate the characteristics of strains which were isolated from market milk treated with ESL(extended shelf life) and conventional system, and to compare the microbiological quality of ESL milk with conventional milk. In order to characterize the isolated strains, purification, Gram staining, spore staining, catalase, oxidase, motility test, and identification by means of automatic identificator were performed. The results obtained are as follows: total 364 selected strains were analyzed in this study. Depending upon the isolated source, the number of strains from conventional milk was found to be Higher than ESL-milk. By means of grouping of total strains, Bacillus ssp. and Staphylococcus ssp. showed to be predominant. But most of strains were distributed with various groups except Lactobacillus ssp. When the isolates were compared with milk process methods, Enterococcus ssp. was detected much on market milk treated with LTLT pasteurization. Also, Pseudomonas ssp. was detected much on conventional milk treated with UHT pasteurization. By comparison with genus groups depending upon storage temperature of market milk, the higher milk storage temperature increased, the most frequency detected Bacillus ssp. increased. Also, Pseudomonas ssp. was detected most frequently at 10$^{\circ}C$ storage condition. Generally this genus derived from post-contamination during milk processing and related to the quality of market milk during chilled system. In conclusion, it was shown that ESL system reduced post-contamination during milk process, following the improvement of product quality and life cycle during the distribution of market milk.

Antioxidative Enzyme Activities and O-J-I-P Transients of Crinum asiaticum var. japonicum $B_{AK}$. Leaves under Winter Stress (겨울철 저온스트레스에 의한 문주란 잎의 항산화효소 활성과 O-J-I-P 곡선 패턴)

  • Oh Soonja;Koh Seok Chan
    • Korean Journal of Environmental Biology
    • /
    • v.23 no.2 s.58
    • /
    • pp.206-213
    • /
    • 2005
  • The diurnal and seasonal variations of antioxidative enzyme activity and the O-J-I-P transients were investigated from the leaves of Crinum asiaticum var. japonicum under winter stress in natural habitat, in order to diagnose quantitatively physiological states of plants under stresses. The activities of superoxide dismutase and peroxidase increased slightly in winter. Especially, peroxidase acitivity was higher at dawn and night in winter and some isoforms were detected only in early winter. In the O-J-I-P transients, the fluorescence intensity of J, I, P steps decreased significantly in winter season, contrary to its high value in summer season. Of the chlorophyll fluorescence parameters derived from the O-J-I-P transients, Fm and $\Phi_{po}$ decreased with the increase of ABS/RC depending on temperature drop in winter.

국내외 벼 수확후 관리 현황조사

  • 손종록;김재현;이정일;박정화
    • Proceedings of the Korean Society of Postharvest Science and Technology of Agricultural Products Conference
    • /
    • 2003.04a
    • /
    • pp.107-107
    • /
    • 2003
  • 고품질 쌀 생산을 위하여 우리나라의 농가 및 미곡종합처리장의 벼 수확후 품질관리 현황 실태를 조사하여 일본, 미국, 중국 둥의 현황과 비교하였다. 중국의 경우 벼 수확은 대부분 인력에 의존하고 있으며, 일본은 산물형 콤바인 그리고 미국은 대형산물 콤바인에 의한 적기수확을 하고 있다. 우리나라의 경우에는 콤바인이 부족하고 벼 수확시기는 콤바인 운영자의 일정에 따라 결정되고 있으며 습논, 소면적 재배 논은 수확이 늦어져 적기 수확이 못되고 있는 실정이다. 한편 일본은 라이스센터, 컨트리엘레베타, 드라이스토아 등의 지원으로 적기 수확이 가능하고 건조기 건조율도 90%이상 2단계 상온 통풍체계로 수분함량 14.5~15.5%를 유지하고 있다. 우리나라를 제외한 일본, 중국, 미국의 저장시설은 대부분 대형저장 사이로에서 품종별, 산지별, 등급별로 구분한 저온저장 시스템을 갖추어 품질을 유지하고 있었다. 또한 도정시설도 고품질 도정시설을 완비하고 있으며 제현이나 정미과정에 색채선별기, 금속검출기, 활성화 장치 및 입형분리기 등을 통하여 불완전미가 제거하는 등 수확후 관리에 철저를 기하고 있다. 쌀의 등급화 및 유통과정를 보면 일본, 중국, 미국 등은 대부분이 품종, 산지 및 등급별로 브랜드화 하여 차별화 된 가격으로 판매되고 있으며 포장지에 쌀에 대한 정보를 최대한 표시하여 소비자가 선택하는데 도움이 되게 하여 유통되고 있다.

  • PDF

A Study on THz Generation and Detection Characteristics of InGaAs Semiconductor Epilayers (InGaAs 반도체 박막의 테라헤르쯔(THz) 발생 및 검출 특성 연구)

  • Park, D.W.;Kim, J.S.;Noh, S.K.;Ji, Young-Bin;Jeon, T.I.
    • Journal of the Korean Vacuum Society
    • /
    • v.21 no.5
    • /
    • pp.264-272
    • /
    • 2012
  • In this paper, we report THz generation and detection characteristics investigated by InGaAs semiconductor epilayers, as results of a basic study obtained from the InGaAs-based THz transmitter/receiver (Tx/Rx). High-temperature and low-temperature (LT) grown InGaAs epilayers were prepared by the molecular beam epitaxy technique for the characterization of THz generation and detection, respectively, and the surface emission based on the photo-Dember effect was tried for THz generation. THz wave was generated by irradiation of a Ti:Sapphire fs pulse laser (60 ps/83 MHz), and a LT-GaAs Rx was used for the THz detection. The frequency band shown in the spectral amplitudes Fourier-transformed from the measured current signals was ranging in 0.5~2 THz, and the signal currents were exponentially increased with the Tx beam power. The THz detection characteristics of LT-InGaAs were investigated by using an Rx with dipole (5/20 ${\mu}m$) antenna, and the cutoff frequency was ~2 THz.

Heat Flow Studies in Low Temperature Detectors (저온검출기의 열전도 연구)

  • Kim, Il-Hwan;Lee, Min-Kyu;Kim, Yong-Hamb
    • Progress in Superconductivity
    • /
    • v.12 no.1
    • /
    • pp.41-45
    • /
    • 2010
  • Low temperature micro-calorimeters have been employed in the field of high resolution alpha spectrometers. These alpha detectors typically consist of a superconducting or metal absorber and a temperature sensor. The temperature sensor can be a transition edge sensor (TES), a metallic magnetic calorimeter (MMC) or other low temperature detectors for an accurate measurement of temperature change due to an alpha particle absorption. We report a recent study of the heat flow between a replaceable absorber and a temperature sensor. A piece of gold foil in $2.4{\times}2.7{\times}0.03\;mm^3$ is used as an absorber. A $40\;{\mu}m$ diameter Au:Er paramagnetic sensor is attached to another small piece of gold foil in $400{\times}200{\times}30\;{\mu}m^3$ to serve as the temperature sensor. This sensor assembly, Au:Er and gold foil, is placed on a miniature SQUID susceptometer in a gradiometric configuration. The thermal connection between the absorber and the sensor was made with three gold bonding wires. The measured thermal conductance shows a linear dependence to the temperature. The values are in a good agreement with Wiedemann-Franz type thermal conductance of the gold wires.

Hydrocarbon Speciation in Low Temperature Diesel Combustion (저온 디젤 연소에서 발생하는 탄화수소 종 분석)

  • Han, Man-Bae
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.34 no.4
    • /
    • pp.417-422
    • /
    • 2010
  • Low temperature diesel combustion was achieved via a combination of late injection timing ($8.5^{\circ}$ CA BTDC to $0.5^{\circ}$ CA BTDC) and heavy exhaust gas recirculation (37% to 48%) with ultra low sulfur Swedish diesel fuel in a 1.7L common rail direct injection diesel engine. When injection timing is retarded at a certain exhaust gas recirculation rate, the particulate matter and nitrogen oxides decease simultaneously, while the hydrocarbon and carbon monoxide increase. Hydrocarbon speciation by gas chromatography using a flame ionization detector reveals that the ratio of partially burned hydrocarbon, i.e., mainly alkenes increase as the injection timing is retarded and exhaust gas recirculation is increased. The two most abundant hydrocarbon species are ethene which is a representative species of partially burned hydrocarbons, and n-undecane, which is a representative species of unburned hydrocarbons. They may be used as surrogate hydrocarbon species for performing a bench flow reactor test for catalyst development.

Liquefaction Characteristics of Polyethylene-Polypropylene Mixture by Pyrolysis at Low Temperature (Polyethylene-Polypropylene 혼합물의 저온 열분해에 의한 액화특성)

  • Cho, Sung-Hyun;Choi, Hong-Jun;Na, Byung-Ki;Lee, Bong-Hee
    • Clean Technology
    • /
    • v.15 no.2
    • /
    • pp.109-115
    • /
    • 2009
  • The low temperature pyrolysis of polyethylene (PE), polypropylene (PP) and polyethylene-polypropylene (PE-PP) mixture in a batch reactor at the atmospheric pressure and $450^{\circ}C$ was carried out to investigate the synergy effect of PE-PP mixture. The pyrolysis time was from 20 to 80 mins. The products formed during pyrolysis were classified into gas, gasoline, kerosene, gas oil and heavy oil according to the petroleum product quality standard of Korea Institute of Petroleum Quality. The analysis of the product oils by GC/MS showed that no new component was detected and no synergy effect was made by mixing of PE and PP. Conversions and yields of PE-PP mixtures were linearly dependent on the mixing ratio of samples.

Numerical Investigation of Temperature Uniformity and Estimation Accuracy for MEMS-based Black Body System (MEMS 기반 흑체 시스템의 온도 균일도 및 추정 정확도의 수치 해석적 검토)

  • Chae, Bong-Geon;Kim, Tae-Gyu;Lee, Jong-Kwang;Kang, Suk-joo;Oh, Hyun-Ung
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.44 no.5
    • /
    • pp.455-462
    • /
    • 2016
  • Output Characteristics of the spaceborn image sensor such as infrared(IR) sensor are varied according to time elapses and sensor repetition on/off operation. As a result, the quality of IR sensor image is decreased. Therefore, spaceborne image sensor require a periodic calibration using a black body system by correcting a non-uniformity of the sensor. In this paper, we proposed a MEMS-based black body system that can implement the high temperature uniformity at various standard temperatures ranging from low to high temperature and easily estimate the representative surface temperature. In addition, it has advantages lightweight, low-power and high accuracy. The feasibility of the proposed MEMS-based black body system was verified through the thermal analysis.