• Title/Summary/Keyword: 저선량방사선

Search Result 374, Processing Time 0.033 seconds

Comparison of Noise and Doses of Low Dose and High Resolution Chest CT for Automatic Tube Current Modulation and Fixed Tube Current Technique using Glass Dosimetry (유리선량계를 이용한 관전류자동조절기법과 고정관전류기법에서 저선량 및 고해상 흉부CT의 노이즈 및 선량 비교)

  • Park, Tae Seok;Han, Jun Hee;Jo, Seung Yeon;Lee, Eun Lim;Jo, Kyu Won;Kweon, Dae Cheol
    • Journal of Radiation Industry
    • /
    • v.11 no.3
    • /
    • pp.131-137
    • /
    • 2017
  • To compare the radiation dose and image noise of low dose computed tomography (CT) and high resolution CT using the fixed tube current technique and automatic tube current modulation (CARE Dose 4D). Chest CT and human anthropomorphic phantom were used the RPL (radiophotoluminescence) dosimeters. For image evaluation, standard deviation of mean CT attenuation coefficient and CT attenuation coefficient was measured using ROI analysis function. The effective dose was calculated using CTDIvol and DLP. CARE Dose 4D was reduced by 74.7% and HRCT by 64.4% compared to the fixed tube current technique in low dose CT of chest phantom. In CTDIvol and DLP, the dose of CARE Dose 4D was reduced by fixed tube current technique. For effective dose, CARE Dose 4D was reduced by 47% and HRCT by 46.9% compared to the fixed tube current method, and the dose of CARE Dose 4D was significantly different (p<.05). Noise in the image was higher than that in the fixed tube current technique. Noise difference in the image of CARE Dose 4D in low dose CT was significant (p<.05). The low radiation dose and the noise difference of the CARE Dose 4D were compared with the fixed tube current technique in low dose CT and HRCT using chest phantom. The radiation doses using CARE Dose 4D were in accordance with the national and international dose standards. CARE Dose 4D should be applied to low dose CT and HRCT for clinical examination.

A Study on Feasibility of Total Variation Algorithm in Skull Image using Various X-ray Exposure Parameters (다양한 X-ray 촬영조건을 이용하여 획득한 skull 영상에서의 Total Variation 알고리즘의 가능성 연구)

  • Park, Sung-Woo;Lee, Jong-In;Lee, Youngjin
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.5
    • /
    • pp.765-771
    • /
    • 2019
  • Noise in skull X-ray imaging is inevitable, which reduces imaging quality and diagnostic accuracy and increases errors due to the nature of digital imaging devices. Increasing the dose can attenuate noise, but that could lead to big problems with higher exposure dose received by patients. Thus, noise reduction algorithms are actively being studied at low doses to solve dose problems and reduce noise at the same time. Wiener filter and median filter have been widely used, with the disadvantages of poor noise reduction efficiency and loss of much information about imaging boundary. The purpose of this study is to apply total variation (TV) algorithm to skull X-ray imaging that can compensate for the problems of previous noise reduction efficiency to assess quantitatively and compare them. For this study, skull X-ray imaging is obtained using various kVp and mAs using the skull phantom using the X-ray device of Siemens. In addition, contrast to noise ratio (CNR) and coefficient of variation (COV) are compared and measured when noisy image, median filter, Wiener filter and TV algorithm were applied to each phantom imaging. Experiments showed that when TV algorithms were applied, CNR and COV characteristics were excellent under all conditions. In conclusion, we've been able to see if we can use TV algorithm to improve image quality and CNR could be seen to increase due to the decrease in noise as the amount of increased mAs. On the other hand, COV decreased as the amount of increased mAs, and when kVp increased, noise was reduced and the transmittance was increased, so COV was reduced.

Evaluation of Electron Beam Dose Distribution by Age Diffusion Equation (연령 확산 이론에 의한 전자선의 조직내 선량분포 평가)

  • 추성실
    • Progress in Medical Physics
    • /
    • v.4 no.1
    • /
    • pp.29-39
    • /
    • 1993
  • Electron beams have found unique and complementary used in the treatment of cancer, but it's very difficult to delineate dose distribution, because of multi-collisions. Numerical solution is more usefull to describe electron distributed in tissue. A semi-empirical eqution is given for the dose at any point at various depths in water. This equation is a modificated model which was based on solutions of a general age diffusion equation. Parameters have been calulated from electron beams data with energies 6~18MeV form a LINAC for use in computerised dosimetry calculations. The depth doses and isodose curves are predicted as a function of the practical range, source skin distance and field size. Depth dose accuracy have been achieved 2% above 50% depth dose and 5% at lower doses, relative to maximum dose. Also, the shape of the isodose curves with the constrictions at higher dose and bulging ot lower values are accurately predicted. Computer calculated beams have been used to generate ever isodose distribution for certain clinical situations.

  • PDF

Evaluation of the Availability of the Wide Coverage Volume Axial Mode in Pediatric Cardiac CT (소아 심장 CT검사 시 Wide Coverage Volume Axial Mode의 유용성 평가)

  • Park, Ki Seok;Kim, Dong Hyun
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.5
    • /
    • pp.683-689
    • /
    • 2019
  • We are trying to evaluate usefulness of Wide Coverage Volume Axial Mode by comparing and analyzing for exposure doses to patients and video quality extracted from two materials. First material is a computer tomography scanning of paediatric cardiac made by using High Pitch Mode, which is designed for diagnosing Congenital cardiac diseases. Second material is computer tomography scanning of paediatric cardiac made by using Wide Coverage Volume Axial Mode. When we did computer tomography scanning of paediatric cardiac, we used High Pitch Mode and Wide Coverage Volume Axial Mode to 50 patients of each, overall 100 patients. Also, we compared exposure doses to patients using videos got from each protocol. Then we compared video quality by calculating SNR and CNR by setting ROI of each. Not only exposure doses to patients were reduced by 13.07 %, but also SNR and CNR were improved when testing used Wide Coverage Volume Axial Mode rather than using High Pitch Mode. Wide Coverage Volume Axial Mode reduced testing time by using high-speed scanner. Furthermore, we can find out that Wide Coverage Volume Axial Mode is an useful method through improving video quality and reducing exposure doses to patients than using High Pitch Mode from ASiR-V, which is low-dose technology.

Diffuse Pigmented Villonodular Synovitis of the Knee: Case Report (무릎 관절의 미만형 색소 융모 활액막염: 증례 보고)

  • Choi, Sang-Gyu
    • Radiation Oncology Journal
    • /
    • v.25 no.4
    • /
    • pp.278-282
    • /
    • 2007
  • Purpose: Diffuse pigmented villonodular synovitis (PVNS) is an uncommon aggressive synovial proliferative disorder of unknown etiology affecting the joint linings. Though a histologically benign inflammatory process, because of its aggressive growth with bone destruction or recurrence, it is frequently suggested to occur as a low malignant neoplasm. Optimal treatment is surgery, but the local recurrence rate after radical synovectomy for diffuse PVNS is relatively high due to the infiltrative growth pattern. External beam radiotherapy with moderate doses or intra-articular instillation of radioactive isotopes may improve the likelihood of local control and long-term function in patients with incompletely resected or recurrent diffuse PVNS. I report one case of diffuse PVNS of the right knee joint treated with arthroscopic synovectomy and external beam radiotherapy is presented.

Occupational Radiation Exposure to Hospital Workers: On the Effect of Hematological Change (병원 내 방사선 작업종사자의 만성적 방사선 피폭에 의한 혈액학적 성분 변화에 관한 연구)

  • Ryu, Jae-Kwang;Jung, Woo-Young;Shin, Sang-Ki;Cho, Shee-Man;Dong, Kyung-Rae;Kim, Hyun-Soo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.12 no.3
    • /
    • pp.157-170
    • /
    • 2008
  • Purpose: This prospective study was conducted to reveal the haematological index change by low level radiation exposure in radiological environment our hospital workers. Materials and Method: We gathered the cumulative dose by Thermoluminenscent Dosimeters (TLD) over 9-yr period and examined hematological index counts change (RBC, Hb, Platelet, WBC, Monocyte, Lymphocyte, Neutrophilic, Basophilic, Eosinophilic) both occupational workers and controls. Of a total 370 occupational workers and 335 controls were compared. Results: This analysis has led to the following general observations 1) The average cumulative dose in male and female were $9.65{\pm}15.2\;mSv$, $4.82{\pm}5.55\;mSv$ respectively. 2) In both male and female, there were very low relationship between occupation period and cumulative dose (r< ${\pm}0.25$). 3) Occupation period was more increased, in male, WBC counts decreased and increased workers, RBC counts decreased workers were more than controls group (p<0.05). In female, WBC counts decreased and increased workers and W-eosino counts decreased workers were more than controls group (p<0.01). 4) Cumulative dose was more increased, in male, W-Lympho counts decreased workers and Platelet counts deceased workers were more than controls group (p<0.05). In female, W-lympho counts decreased workers and RBC counts decreased workers were more than controls group (p<0.05). Conclusions: We can find some kinds of blood index abnormal distribution in occupational radiation workers by comparing with controls. Occupational workers cannot avoid radiation exposure, in spite of the control it. Actually low level radiation adverse effect occurred not dose but probability. So workers must always try to reduce exposure by ourselves, furthermore as long as possible the government should provide rapidly that national system on radiation control for worker's health.

  • PDF

Comparison Study of Conventional Film-based and CT-reconstruction method in HDR Brachytherapy (고선량률 근접 방사선 치료에서 기존의 필름 방법과 CT 재구성 방법의 비교 연구)

  • 장지나;이형구;윤세철;서태석
    • Progress in Medical Physics
    • /
    • v.15 no.2
    • /
    • pp.63-69
    • /
    • 2004
  • HDR brachytherapy administers a large dose of radiation in a short time compare with LDR, and its optimization for treatment is related to several complex factors, such as physical, radiation and optimization algorithms, so there is a need for these to be verified for accurate dose delivery. In our approach, a previous study concerning the phantom for dose verification has been modified, and a new pelvic phantom fabricated for the purpose of localization, including a structure enabling the use of a CT or MRI system. In addition, a comparison study was performed to verify an orthogonal method that is commonly used for brachytherapy localization by comparing target coordinates from a CT system. Since the developed phantom was designed to simulate the clinical setups of cervix cancer, it included an air-filled bladder and a rectum structure shaped sphere and cylinder An N-shaped localizer was used to obtain precision coordinates from both CT and films. Moreover, the IDL 5.5 software program for Windows was used to perform coordinates analysis based on an orthogonal algorithm. The film results showed differences within 1.0 mm of the selected target points compare with the CT coordinates. For these results, a Plato planning system (Nucletron, Netherlands) could be independently verified using this phantom and software. Furthermore, the new phantom and software will be efficient and powerful qualify assurance (QA) tools in the field of brachytherapy QA.

  • PDF

The implementation of a Gd-pMOSFET thermal neutron detector and the enhancement of its sensitivity (Gd-pMOSFET 열중성자 측정기 구현 및 감도개선)

  • Lee, Nam-Ho;Kim, Seung-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2005.10b
    • /
    • pp.430-432
    • /
    • 2005
  • 저에너지 중성자가 가톨리늄(Gd) 막에 입사되면 중성자 포획과정에서 전환전자가 생성된다. 이 전환전자에 의해 pMOSFET $SiO_2$ 산화층에서 발생된 전자-전공쌍이 발생되고, 이 가운데 정공은 산화층 내부에 쉽게 붙잡혀(Trap) 양전하 센터로 작용하게 된다. 이 축적된 전하는 pMOSFET의 문턱전압(Threshold voltage)을 변화시킨다. 본 연구에서는 이러한 간접측정 원리를 이용하여 열중성자를 실기간 탐지할 수 있는 반도체형 탐지소자를 개발하고 하나로(HANARO) 방사선장에서의 시험을 통해 성능을 검증하였다. 그리고 감도관련 변수의 최적화를 통하여 작업자가 사용 가능한 범위의 고감도 열중성자 선량계로 개선 제작하였다. 개발된 선량계는 소형으로 실시간 열중성자 측정이 가능하며 감마방사선으로부터 독립적으로 열중성자를 측정할 수 있는 장점도 지니고 있다.

  • PDF

Systems Engineering Approach for the Reuse of Metallic Waste From NPP Decommissioning and Dose Evaluation (금속해체 폐기물의 재활용을 위한 시스템엔지니어링 방법론 적용 및 피폭선량 평가)

  • Seo, Hyung-Woo;Kim, Chang-Lak
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.15 no.1
    • /
    • pp.45-63
    • /
    • 2017
  • The oldest commercial reactor in South Korea, Kori-1 Nuclear Power Plant (NPP), will be shut down in 2017. Proper treatment for decommissioning wastes is one of the key factors to decommission a plant successfully. Particularly important is the recycling of clearance level or very low level radioactively contaminated metallic wastes, which contributes to waste minimization and the reduction of disposal volume. The aim of this study is to introduce a conceptual design of a recycle system and to evaluate the doses incurred through defined work flows. The various architecture diagrams were organized to define operational procedures and tasks. Potential exposure scenarios were selected in accordance with the recycle system, and the doses were evaluated with the RESRAD-RECYCLE computer code. By using this tool, the important scenarios and radionuclides as well as impacts of radionuclide characteristics and partitioning factors are analyzed. Moreover, dose analysis can be used to provide information on the necessary decontamination, radiation protection process, and allowable concentration limits for exposure scenarios.

The reliability of the cephalogram generated from cone-beam CT (Cone-beam CT로부터 제작된 측모 두부계측방사선사진의 정확도 평가)

  • Kang, Ji-Young;Kim, Kwang-Won;Lim, Sung-Hoon
    • The korean journal of orthodontics
    • /
    • v.37 no.6
    • /
    • pp.391-399
    • /
    • 2007
  • Three-dimensional approaches for the diagnosis and analysis of the dentofacial area are becoming more popular in accordance with the development of cone-beam CT (CBCT). The purposes of this study were to evaluate the reliability of cephalometric measurements of lateral cephalograms generated from a CBCT image by making comparisons with the traditional digital lateral cephalogram, and to evaluate the possibility of the clinical application of CBCT generated cephalogram images. Methods: Twenty patients whose external auditory meatus could be identified in the CBCT image were selected, and both CBCT and digital cephalograms were taken. Differences between the measurements of both cephalograms were tested by paired t-test. Results: Among the 22 measurements used, only U1-FH, Mx6 to PTV, and maxillomandibular difference showed statistically significant differences between the CBCT generated cephalogram and the digital cephalogram. Conclusions: The results suggest that the CBCT generated cephalogram can be used for some cephalometric measurements not requiring porion, PTV, condylion as a landmark (SNA, SNB, U1 to SN, IMPA, interincisal angle, etc.).