• Title/Summary/Keyword: 재하실험

Search Result 712, Processing Time 0.02 seconds

Determination of True Resistance from Load Transfer Test Performed on a PHC Pile (PHC 말뚝의 하중전이실험을 통한 참 지지력의 산정)

  • Kim, Sung-Ryul;Chung, Sung-Gyo;Dzung, N.T.
    • Journal of the Korean Geotechnical Society
    • /
    • v.22 no.11
    • /
    • pp.113-122
    • /
    • 2006
  • Although a number of static pile load tests have been performed in this country, re-consideration on the interpretation and loading method is needed, because of their less usefulness in practice. For this study, a static loading testing was performed for a long instrumented PHC pile, which was installed in sand layer overlying thick soft clay. The shaft resistance of the pile had been monitored for a long time after installation, and then the static load testing was performed by the quick load test, unlike the recent Korean practice. Using the measured data, the elastic modulus of pile, residual stress and true resistance on the pile were determined. In the event, it was found that the residual stress on the pile, which remained prior to the static loading, significantly affects the shaft and toe resistances. Also, it was realized that the setup effect for the long pile is significant.

About Fatigue Load Conduct Analysis of Simplified Composite Deck (피로하중에 대한 초간편 강합성 바닥판의 거동 분석)

  • Lee, Sung-Yol;Yoon, Ki-Yong;Yi, Gyu-Sei;Kim, Sang-Seup
    • 한국방재학회:학술대회논문집
    • /
    • 2010.02a
    • /
    • pp.79.2-79.2
    • /
    • 2010
  • 실제 교량 바닥판의 거동은 반복하중에 의한 피로누적 손상에 의해 발생되므로 성능분석을 위해서는 피로 실험결과를 통한 구조거동 분석이 이루어져야 할 것이다. 이에 본 논문에서는 현재 개발 중인 초간편 강합성 바닥판의 피로성능을 파악하기 위해 일점 재하 방식으로 반복 하중을 재하 하였다. 실험체의 거동을 파악하기 위해 변위계를 설치하여 변위를 측정하였고 이 실험의 결과로 신형식 바닥판인 초간편 강합성 바닥판의 피로 파괴 양상을 알 수 있었으며 피로 곡선을 얻을 수 있었다. 하지만 바닥판의 파괴요인 중 외부 환경적 요인과 실제 차량 하중 이동을 모사한 윤하중 재하 시 피로 성능에 대한 연구가 추가로 이루어져야 할 것으로 판단된다.

  • PDF

A Study on the loading test for of slab by Fire damaged (화재피해를 입은 RC 슬래브의 재하실험에 관한 연구)

  • Lee, Kyu Min;Kang, Seung Goo;Kim, Dong Jun;Kwon, Young Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2013.11a
    • /
    • pp.50-51
    • /
    • 2013
  • In case of Korea, it goes frequently that underground parks has been burned. Based on standard temperature time curve(ISO-834), gerber, walls, slab of structures are constructed. However, Standard temperature time Curve is not considered that buildings are affected by vehicle fire. that is why it has the hazard that makes building reinforcement feeble. Based on the result that got from vehicle experiment before, we made four RC slab in this experiment and set the fire severity. according to the loading experiment after heating, we measured the effects that makes reinforcement and shape changes. Furthermore, we examined the safty of the structure by comparing before and after heating.

  • PDF

A Study on the Static and Dynamic Characteristics of Raised Girder Bridges (양각 거더교의 정적·동적특성에 관한 연구)

  • Ji-Yeon Lee;Sung Kim;Sung-Jin Park
    • Journal of the Society of Disaster Information
    • /
    • v.19 no.4
    • /
    • pp.851-858
    • /
    • 2023
  • Purpose: A study was conducted to ensure the structural safety of a raised girder bridge with improved cross-sectional efficiency compared to the conventional PSC girder. For this purpose, the cross-sectional specifications such as girder length, height, and width were determined, the arrangement of the tendons was designed, and the practical performance of the raised girder under static and dynamic loads was verified. Method: The static performance experiment examined the serviceability limit state by measuring behavioral responses such as deflection and cracking to primary and secondary static loads. In addition, the dynamic load loading experiment measured the acceleration and displacement behavior response over time to calculate the natural frequency and damping ratio to examine the usability limit state. Result: As a result of the static performance test, the deflection value based on the maximum applied load showed stable behavior, and the crack width measured at the maximum applied load level was very small, satisfying the serviceability limit state. In addition, a natural frequency exceeding the natural frequency calculated during the design of the dynamic loading experiment was found, and a damping ratio that satisfies the current regulations was found to be secured.

The Static Behavior of Bridge Expansion Joints Due to the Wheel Load (윤하중 재하에 의한 교량 신축이음의 정적거동)

  • Kim, Youngjin;Kwak, Imjong;Cho, Changbaek;Yoon, Hyejin
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.28 no.3A
    • /
    • pp.357-366
    • /
    • 2008
  • This study addresses the analysis of the behavioral characteristics of bridge expansion joints under wheel loading through wheel load test and the proposal of relevant wheel load specifications for expansion joints. To that goal, specimens of rail and finger expansion joints that are widely used in Korea were fabricated and subjected to static wheel load test using a real tire wheel. The wheel load distribution factor in the rail and finger expansion joints in contact with the wheel load was evaluated. The evaluation revealed that the portion of load sustained by the central rail of rail expansion joint was decreasing with larger wheel load, and that the portion of load sustained by the finger expansion joint was practically insensitive to the increase of the contact area and remained nearly constant. Since the wheel load characteristics showed large difference compared to former design specifications, it appears necessary to prepare rational specifications relative to the distribution of the wheel load contact pressure for the design of expansion joints.

A Study on Static Behavior of 60 m span Half-Decked PSC Girder (Half-Deck을 포함한 60 m 경간 PS 콘크리트거더의 정적 거동 연구)

  • Kim, Tae Min;Park, Jong Heon;Kim, Moon Kyum;Lim, Yun Mook
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.32 no.2A
    • /
    • pp.65-73
    • /
    • 2012
  • In this study, we tested structural performance of Half-Decked PSC girder which was developed for applying to long span bridge. We operated 4 point bending test with 60 m span full scale girder designed as simple bridge with hinge-roller boundary condition. Actuators were set on the both sides of girder, 5.5 m away from the center, and 4 stages of cyclic loading was applied at rate of 1 kN/sec. Through stages 1 to 4, loading and unloading 1,000 kN, 1,200 kN, 1,500 kN, and 2,000 kN were repeated and displacement, strain of concrete and steel, crack of girder were checked. From these results, the strength of girder was assessed and resilience and ductility were observed after removing the load. Since initial flexural crack occurred in the vicinity of 1,400 kN, non-linearity of load-displacement curve appeared and definite residual strain was measured at that point. The test result showed that initial cracking load was over twice the DB-24 load which means the developed girder had sufficient strength. To verify the experimental results, we numerically analyze the test and confirmed that the data were similar with results from the test above. Half-Decked PSC type of 60 m-girder developed in this study showed its adequate structural capacity through static loading test, which proved that possibility of applying the girder to actual bridges practically.

A Modified Parallel Iwan Model for Cyclic Hardening Behavior of Sand(II) : Verification (수정 IWAN 모델을 이용한 사질토의 반복경화거동에 대한 연구(II) : 모델 검증)

  • 이진선;김동수;추연욱;윤종구
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.7 no.5
    • /
    • pp.57-66
    • /
    • 2003
  • In order to verify the applicability of the developed modified parallel IWAN model. two types of cyclic torsional shear tests were performed using Kum-Kang and Toyoura sands. One was a symmetric-limit loading test and the other was an irregular loading test. Model parameters were derived from the symmetric limit loading tests at various relative densities and confining pressures. The modified parallel IWAN model can predict the cyclic hardening behavior of sands very well as increasing loading cycles in the symmetric-limit tests. Irregular loading tests were performed using the loading shape suggested by Pyke(1979). Cyclic behaviors under irregular loading were simulated using model parameters derived from symmetric limit loading test results of similar loading conditions. The predicted cyclic hardening behaviors under irregular loading matched well with experimental results and the applicability of the proposed model was verified.