• Title/Summary/Keyword: 재질안정성

Search Result 186, Processing Time 0.029 seconds

The Material Analysis and a Study on the Conservation Treatment of Taejo's Portrait Mounting Decorative Knots in the National Palace Museum of Korea Collection (국립고궁박물관 소장 태조어진 장황 유소의 재질분석 및 보존처리 방안 연구)

  • Lee, Seung Lee;Wi, Koang Chul
    • Journal of Conservation Science
    • /
    • v.31 no.1
    • /
    • pp.65-73
    • /
    • 2015
  • The purposes of this study are helping the understanding on the Dae-hwe kind relics, verifying the deformation rate stability during conservation treatment and enhancing the conservation treatment work by investigating the status and analyzing the material of Taejo's portrait mounting decorative knots in the National Palace Museum of Korea collection. The result of material analysis on the decorative knots was that the outer threads are silk threads, inner threads are cotton threads, the width of the metal threads was $500{\sim}600{\mu}m$ and the major component of it was 55wt% copper. The result of verification on the deformation rate during the form correction of the bell tassel was that it has been found as stable by having the deformation rate of 1 TPCM or less. The result of glue selection test to be used on the repairing of tassel cross-section with its thread cut was that wheat starch adhesive has been found most appropriate because it has the highest tensile strength at all concentrations. The conservation and treatment procedure was established based on above results of analysis and test on the relic and the conservation treatment work including packaging has been completed in accordance with the established procedure.

Comparison of sample storage containers for the analysis of volatile organic compounds (VOC) (휘발성유기물(VOC) 분석을 위한 시료보관 용기의 비교)

  • Kim, Seokyung;Kim, Dalho
    • Analytical Science and Technology
    • /
    • v.35 no.3
    • /
    • pp.116-123
    • /
    • 2022
  • Polymer bags, metallic canisters, and glass bottles have been used as containers for analyzing the volatile organic compounds (VOCs) in air. In this study, various sampling containers were compared to investigate the short-term stability of VOCs, that is, from the time they are sampled to the time they are analyzed. Polyvinyl fluoride (PVF), polypropylene (PP), polyester aluminum (PE-Al) bags, canisters, and glass bottles were used as sample containers. A 100 nmol/mol standard gas mixture of benzene, toluene, ethylbenzene, m-xylene, styrene, and o-xylene was used for the VOC comparison. Changes in the concentrations of samples stored for 10~20 day in each container were measured using a thermal desorption-gas chromatograph-flame ionization detector (TD-GC-FID). As a result, VOCs stored in a canister and two kinds of amber glass bottles have shown immaterial decreases in concentration in one week, and more than 80 % of the initial concentration was maintained for two weeks. In the case of polymer bags, the concentration of all VOCs, except benzene and toluene, were remarkably decreased below 70% of the initial concentration in one day. Particularly, ethylbenzene, xylene, and styrene have shown dramatic decreases in concentration below 30 % of the initial concentration in all polymer bags in one day.

Evaluation of Suitability of Non-Standardized Test Block for Ultrasonic Testing (비규격 초음파 탐상용 표준시험편의 사용안전성 평가)

  • Kwon, Ho-Young;Lim, Jong-Ho;Kang, Sei-Sun
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.20 no.5
    • /
    • pp.431-437
    • /
    • 2000
  • Standard Test Block(STB) for UT(Ultrasonic Testing) is a block approved by authoritative for material, shape and quality. STB is used for characteristic tests, sensitivity calibration and control of the time base range of UT inspection devices. The material, size and chemical components of STB should be strictly controled to meet the related standards such as ASTM and JIS because it has an effect upon sensitivity, resolution and reproductivity of UT. The STBs which are not approved are sometimes used because the qualified STBs are very expensive. So, the purpose of this study is to survey the characteristics, quality and usability of Non-Standardized Test Blocks. Non-Standardized Test Blocks did not meet the standard requirements in size or chemical components, and ultrasonic characteristics. Therefore if the Non-Standardized Test Blocks are used without being tested, it's likely to cause errors in detecting the location and measuring the size of the defects.

  • PDF

Evaluation of Material Properties of Acetylated Medium Density Fiberboard (MDF) (아세틸화 처리 중밀도 섬유판(MDF)의 재질 평가)

  • LEE, Jong Shin;KIM, Soung Joon
    • Journal of the Korean Wood Science and Technology
    • /
    • v.48 no.3
    • /
    • pp.393-404
    • /
    • 2020
  • This study examined the material properties of MDF manufactured using acetylated pinus radiata fibers against moisture and compared the properties with the fiberboard quality standards of KS F 3200. Since acetylated MDF shows very low moisture content, water absorption and thickness swelling than the quality standards, it is expected to have an excellent dimensional stability. The bending strength in wetting condition of the acetylated MDF reached approximately 70% of the bending strength in dry condition, making it suitable for the quality standards. The internal bond of the acetylated MDF in the wetting condition was higher than the minimum internal bond of the quality standards in the dry condition, showing a good water resistance. Since the water droplet contact angle of the acetylated MDF is larger than that of untreated MDF, it is determined that it contributes in improving the water resistance due to the low wettability.

Study on the Stability of NaBH4 Solution during Storage Process (NaBH4수용액 저장과정 중 안정성에 관한 연구)

  • Sim, Woojong;Jo, Jaeyoung;Choi, Daeki;Nam, Sukwoo;Park, Kwonpil
    • Korean Chemical Engineering Research
    • /
    • v.48 no.3
    • /
    • pp.322-326
    • /
    • 2010
  • Stability of sodium borohydride solution during storage was studied. In order to enhance the $NaBH_4$ stability, NaOH and KOH were added to the $NaBH_4$ solution. The effect of concentration of the borohydride and alkaline solution, temperature and materials of storage vessels on the rate of borohydride hydrolysis was investigated. The rate of hydrogen evolution decreased as the concentration of alkaline increased due to increase of $NaBH_4$ stability in the solution. The stability of $NaBH_4$ solution decreased when the borohydride concentration raised from 10 to 15 wt% and then increased when the $NaBH_4$ concentration increased above 15 wt% due to increase in the pH of the concentrated solution. The activity coefficient of hydrolysis of $NaBH_4$ solution(NaOH 3.0 wt%, $NaBH_4$ 25 wt%) was 115.1 kJ/mol and this value was 1.5~4.0 times higher than that of hydrolysis of $NaBH_4$ solution with catalyst. The borohydride solutions in glass and stainless-steel vessel were more stable than the solution in plastic(PE) vessel.

Research on Functional Paper by using Traditional Dyestuffs (전통 염색 재료를 활용한 기능성 종이 연구)

  • Yi, Sun-Jo;Lee, Hye-Yoon;Cho, Kyoung-Sil;Chung, Yong-Jae
    • Journal of Conservation Science
    • /
    • v.26 no.4
    • /
    • pp.429-436
    • /
    • 2010
  • Dyestuffs extracted from fifteen kinds of natural dyeing materials were researched on their antimicrobial performance against 3 kinds of bacteria and 2 kinds of fungi in order to develop conservation/storage materials of traditional and natural dyed papers. The three types of mordants were evaluated by using the same method and then mixed with the dyestuffs to research their antimicrobial performance. With those results, dyed paper was made by mixing mordants with 9 kinds of dyestuffs with excellent antimicrobial performance. Among the dyed papers, Cotinus coggygria, Coptis chinensis, Phellodendri amurense, Rhus javanica and Acer ginnala multiple mordant papers were found to have an antibacterial quality against fungi, while, in the insect repellent experiment using termites, Coptis chinensis and Phellodendri amurense dyed papers were found to have insect repellent qualities. Also, with regard to the research result about the affect of dyeing paper on other materials like metal, Coptis chinensis have relatively stable qualities. Also, the three types of dyeed paper by Cotinus coggygria, Coptis chinensis and Phellodendri amurense, were found to have a tendency to remove harmful gases. Not only can these dyed papers be used for making storage box for cultural properties to prevent various organic artifacts from bio-damaging, but they can also be utilized as functional finishing materials in various spaces.

Optimum Balancing Using Ggenetic Algorithm (유전 알고리즘을 이용한 최적 평형잡이에 관한 연구)

  • 최원호;양보석;주호진;임동수;노철웅
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1995.04a
    • /
    • pp.137-141
    • /
    • 1995
  • 회전기계에서 발생하는 진동 원인 중 약 60% 이상이 불평형(unbalance)에 의한 진동이다. 불평형은 기계의 과도한 진동을 유발시킬 뿐 아니라 베어링의 수명 단축 및 소음을 발생시킨다. 따라서, 기게의 수명을 연장시키고, 기계의 성능을 향상시키며 부드럽고 진동이 없는 운전을 위하여 평형잡이(balancing)는 절대적으로 중요하다. 불평형은 축 중심선에 대하여 회전체의 질량 분포가 비대칭이기 때문에 발생하는데 그 원인으로는 부품 자체가 비대칭에서 오는 설계 또는 제도 오차, 주물의 기포 및 용접의 불균일 등에 의한 재질상의 결함, 그리고 부품조립시 형상누적공차 등에 의한 가공.조립오차 등이 있다. ISO의 정의에 따르면 평형잡이는 회전체의 질량 분포를 조사하고 필요하다면 저널의 진동과 베어링의 작용력들이 운전속도에 대응하는 주파수에서 특정한 한계내에 있도록 보증하게 하기 위한 조정을 하는 과정이다. 불평형 상태에 대한 조사도 평형잡이로 표현된다. 그러나 수정이 필요하다고 간주된다면 수행된다. 모든 회전체는 초기 불평형(initial unbalance)이라 불리는 임의의 불평형을 가지고 출발한다. 완벽하게 평형이 잡힌 회전체를 달성하는 것이 평형잡이 작업의 목적은 아니다. 임의의 잔류 불평형(residual unbalance)은 항상 허용된다. 경제적인 이유에서 회전체는 일반적으로 요구되는 적절한 허용치보다 더 이상 평형잡이를 하지 않는다. 현장에서 현장 평형잡이를 수행하게 될 경우, 가끔 계산된 수정질량이 매우 클 경우가 있다. 이때 기게의 조건상 큰 수정질량을 부착하기가 곤란한 경우가 자주 발생한다. 작은 수정질량으로 평형잡이를 할 수 있다면 기계의 안정성 면에서 매우 유리하다. 따라서 본 연구에서는 영향계수법(Influence Coefficient Method : ICM)의 기본 개념과 유전 알고리즘(Genetic Algorithm : GA)을 이용하여 회전기계의 안정성을 보장할 수 있는 허용진동 내에서의 최적 수정질량 계산법을 제시한다.

  • PDF

Reliability Evaluation of Rubber Wheel and Steel Wheel for Wheel Tracking Test of Bituminous Concretes (역청 콘크리트 반복주행시험에서 고무바퀴와 강재바퀴의 신뢰성 비교 연구)

  • Hong, Joon-Pyo;Doh, Young-Soo;Kim, Kwang-Woo
    • International Journal of Highway Engineering
    • /
    • v.7 no.2 s.24
    • /
    • pp.97-107
    • /
    • 2005
  • Since the purpose of wheel tracking test is to find out relative difference of mixture's rut resistance, the wheel is an important part in the test for obtaining a consistent output. This study is performed to examine efficiency of different wheel material, rubber and steel in wheel tracking test. The rubber was inserted as a ring on the outer face of the steel wheel, and thickness of rubber ring was 15mm and 7.5mm and 0mm (steel wheel without rubber), making the total outer diameter 200mm. The objective of this study was to select reliable wheel material type in wheel tracking test at $60^{\circ}C$ based on variance in output (rut depth and dynamic stability) and correlation with SD (deformation strength). The result of regression analysis of rut depth with Sd showed that $R^2$ values of wheel rubber thickness of 15mm, 7.5mm and 0mm were 0.7, 0.8 and over 0.9, respectively. In a case of steel wheel (0mm), the highest $R^2$ value was 0.9569. Therefore, the wheel without rubber ring was the best in output consistency level and coefficient of determination $(R^2)$ with deformation strength. Therefore, the steel wheel without rubber ring is suggested as the best choice for wheel tracking test of asphalt concrete.

  • PDF

Basic Factors for Quality Stability of Material Recycling Product Using Plastic Waste from Households (생활계 폐플라스틱 물질 재활용 제품의 품질안정화를 위한 기초 요인 검토)

  • Kang, Suk-Pyo;Kang, Hye-Ju;Shin, Sung-Chul;Kim, Young-Sik;Lee, Hoo-Seok
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.8 no.4
    • /
    • pp.436-443
    • /
    • 2020
  • In this paper, we tried to examine the composition ratio of plastic waste from households according to the generated city and the qualities according to the production time of material recycling products. As a result, the composition ratio of recyclable plastic waste among the total plastic waste according to the generated cities is 64.5~90.4%, showing a big difference by city. In addition, the quality evaluation of material recycling products by production time for four months showed that the average tensile strength was 12.33MPa, the average elongation rate was 5.94%, the average density was 1.35g/㎤ and the average ash content was 3.66%.

Changes in Subjective/Objective Symptoms and the Light Transmissibility of Lens Associated with Overusage of Daily Disposable Circle Contact Lenses in Normal Eyes (일회용 써클소프트렌즈의 초과 착용에 의한 정상안의 자·타각적 증상 및 렌즈 광투과율의 변화)

  • Park, Mijung;Kwon, Hae Lim;Choi, Sae Ah;Kim, So Ra
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.18 no.4
    • /
    • pp.429-439
    • /
    • 2013
  • Purpose: This study was assessed to investigate the change of subjective and/or objective symptoms and the light transmissibility of lens caused by over-usage of daily disposable circle contact lenses (circle lens). Methods: Three daily disposable circle lenses made of etafilcon A, hilafilcon B, and nelfilcon A were applied on 20 normal eyes free from any eye diseases by when subjects complained any kind of discomfort. On the first and the last days of lens wearing, subjective discomfort, blinking rate, non-invasive break-up time, lens centration on corneal surface and visible light transmissibility of lens were recorded at every case and compared. Results: The circle lens wearers complained discomfort when they wore the circle lens more than 15 hours, in excess of 8 hours being the recommended wearing time and the most circle lens wearers quit the lens wearing when they wore more than 30 hours. On the last day of lens wearing, the representative subjective discomforts were stiffness, dryness and tiredness. When the subjects wore circle lens more than the recommended time, a tendency of increased blinking rate and decreased NIBUT was observed when it compared with the values right after lens wearing. On the last day of lens wearing, the lens centration was shown to be decentrated from the pupil center compared with the centration right after the wearing. These changes in lens centration and blinking rate were consistently shown in all cases of lens wearing however, the difference in the degree of subjective and/or objective change was present depending on lens materials and subjects. The visible light transmissibility of circle lens has largely been changed. Conclusions: From these results, it was thought that the decreased NIBUT induced dryness and stiffness and decreased visible light transmissibility caused more blinking when daily disposable circle lens was exceedingly used, which provoked lens decentration and subjective discomfort. However, the difference of subjective and/or objective change was largely varied in accordance with the lens material types and individuality and thus it may occur some unexpected problems by the individual base. Therefore, the education about the necessity to comply with the recommended wearing time and the problem will be essential.