• Title/Summary/Keyword: 재사용 방법

Search Result 4,637, Processing Time 0.042 seconds

Seed Germination, Seedling Growth, and Herbicidal Responses of Bidens tripartita L. (가막사리 (Bidens tripartita L.)의 종자발아, 유묘의 생장 및 제초제반응)

  • Hwang, I.T.;Choi, J.S.;Kuack, H.H.;Kim, J.S.;Lee, H.J.;Cho, K.Y.
    • Korean Journal of Weed Science
    • /
    • v.16 no.2
    • /
    • pp.114-121
    • /
    • 1996
  • This study was conducted to investigate seed germination, seedling growth, and responses to herbicides of Bidens tripartita L. When the field-collected seeds were stored under a dry-room temperature, dry-low temperature, wet-low temperature, or dry-high temperature condition, no seeds were germinated in a growth chamber with 14 hr photoperiod up to 35 days after the storage. Exceptionally, however, some seeds stored under a wet-room temperature condition were germinated after 25 days of the storage. This might be due to the fact that the seed coats were damaged by fungi which developed during the storage. Seeds stored under a wet-low temperature condition (stratification) began to be germinated after 3 months of the storage and the germination rate increased with a prolonged stratification. Almost all seeds were germinated after 9 months of the stratification. These results suggest that the dormancy of B. tripartita L. seeds relate to the seed coat and thus several attempts were made to induce seed germination through damaging or weakening the seed coat. Freezing($-20^{\circ}C$), drying($100^{\circ}C$), or swelling($40^{\circ}C$) of the seeds was not effective to induce the germination. Treatments of concentrated sulfuric acid, $KNO_3$, or gibberellin to the seeds had no effect on inducing the germination. However, ethrel had a stimulatory effect on the germination of the seeds with an optimum concentration of 250ppm. A seed cutting was also effective to induce the germination, but seedlings from the seeds had cutted cotyledons. Germination of the stratified seeds varied with the temperature condition to which they were subjected, but not with light. The germination rate was the highest at 35 - $40^{\circ}C$. Although the seeds were not able to germinate under a submerged condition, seedlings after 2-leaf-stage exhibited better growth under a submerged or a subirrigated condition than under an upland condition. Among the herbicides tested, pyrazosulfuton-ethyl, linuron, and bentazone were found to be effective for controlling B. tripartita L., having more herbicidal effect with an earlier application.

  • PDF

Analysis of temperature changes and sterilization effect of diode laser for the treatment of peri-implantitis by wavelength and irradiation time (임플란트 주위염 치료용 diode laser의 파장 및 조사시간에 따른 온도 변화와 살균효과 분석)

  • Seol, Jeong-Hwan;Lee, Jun Jae;Kum, Kee-Yeon;Lee, Jong-Ho;Lim, Young-Joon
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.33 no.3
    • /
    • pp.178-188
    • /
    • 2017
  • Purpose: We compared the effects of newly developed diode laser (Bison 808 nm Diode laser) on the treatment of peri-implantitis with conventional products (Picasso 810 nm Diode laser) by comparing the surface temperature of titanium disc and bacterial sterilization according to laser power. Materials and Methods: The titanium disc was irradiated for 60 seconds and 1 - 2.5 W using diode laser 808 nm and 810 nm. The surface temperature of the titanium disc was measured using a temperature measurement module and a temperature measurement program. In addition, in order to investigate the sterilizing effect according to the laser power, 808 nm laser was irradiated after application of bacteria to sandblasted large-grit acid-etched (SLA) and resorbable blast media (RBM) coated titanium discs. The irradiated disks were examined with scanning electron microscopy. Results: Both 808 nm and 810 nm lasers increased disk surface temperature as the power increased. When the 810 nm was irradiated under all conditions, the initial temperature rise rate, the descending rate, and the temperature change before and after was higher than that of 808 nm. Disk surface changes were not observed on both lasers at all conditions. Bacteria were irradiated with 808 nm, and the bactericidal effect was increased as the power increased. Conclusion: When applying these diode lasers to the treatment of peri-implantitis, 808 nm which have a bactericidal effect with less temperature fluctuation in the same power conditions would be considered safer. However, in order to apply a laser treatment in the dental clinical field, various safety and reliability should be secured.

The Expression of Chemokine mRNAs in Musculoskeletal Tumors (근골격계 종양의 종류에 따른 케모카인 유전자의 발현)

  • Kim, Hee-Sun;Baik, Won-Jin;Lee, Won-Jae;Shin, Duk-Seop
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.9 no.2
    • /
    • pp.178-189
    • /
    • 2003
  • Purpose: The current study was designed to investigate the expression pattern of chemokine in musculoskeletal tumors, and between primary osteosarcoma and recurred, and postchemotherapy one. Materials and methods: Ten primary soft tissue and bone tumors, one primary, one recurred, one post-chemotherapy osteosarcoma, and one normal control patients were included in the current study. RT-PCR and RPA were used for the investigation of the expression of cytokines and chemokines. Fisher's exact test in SPSS was used for the statistical analysis. Results: IL-8 and TNF-${\alpha}$ were expressed in all tumor tissues, IFN-${\gamma}$ was in all except two cases, RANTES was in 5 soft tissue tumors and 4 bone tumors, GRO-${\alpha}$was in one soft tissue tumor and 2 bone tumors, and MCP-1 and IP-10 were in two bone tumors and in all the other group. In recurred osteosarcoma all the cytokines and chemokines were expressed, and the degree of the expression was stronger than the primary, except IFN-${\gamma}$. After chemotherapy, RANTES, IFN-${\beta}$ and TGF${\beta}_1$ among the TGF${\beta}$isoforms were expressed. Conclusion: There were differences in the expression of cytokines and chemokines in some different bone and soft tissue tumors, even though it was impossible to support this statistically due to small numbers of cases. The expression pattern of IFN-${\gamma}$and TGF-${\beta}$ isoform in osteosarcoma could be used for the study of tumor recurrence and the changes after chemotherapy.

  • PDF

Current Status and Problems of PET/CT Data on CD for Inter-hospital Transfer (병원간 전송용 PET/CT 영상 CD자료의 현황 및 문제점)

  • Hyun, Seung-Hyup;Choi, Joon-Young;Lee, Su-Jin;Cho, Young-Seok;Lee, Ji-Young;Cheon, Mi-Ju;Cho, Suk-Kyong;Lee, Kyung-Han;Kim, Byung-Tae
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.43 no.2
    • /
    • pp.137-142
    • /
    • 2009
  • Purpose: This study was performed to find the current problems of positron emission tomography/computed tomography(PET/CT) data on CD for inter-hospital transfer. Materials and Methods: The subjects were 746 consecutive $^{18}F$-fluorodeoxyglucose PET/CT data CDs from 56 hospitals referred to our department for image interpretation. The formats and contents of PET/CT data CDs were reviewed and the email questionnaire survey about this was performed. Results: PET/CT data CDs from 21 of 56 hospitals(37.5%) included all transaxial CT and PET images with DICOM standard format which were required for authentic interpretation. PET/CT data from the others included only secondary capture images or fusion PET/CT images. According to this survey, the main reason of limited PET/CT data on CD for inter-hospital transfer was that the data volume of PET/CT was too large to upload to the Picture Archiving and Communication System. Conclusion: The majority of hospitals provided limited PET/CT data on CD for inter-hospital transfer, which could be inadequate for accurate interpretation and clinical decision making. It is necessary to standardize the format of PET/CT data on CD for inter-hospital transfer including all transaxial CT and PET images with DICOM standard format.

Preparationand Characterization of Rutile-anatase Hybrid TiO2 Thin Film by Hydrothermal Synthesis

  • Kwon, Soon Jin;Song, Hoon Sub;Im, Hyo Been;Nam, Jung Eun;Kang, Jin Kyu;Hwang, Taek Sung;Yi, Kwang Bok
    • Clean Technology
    • /
    • v.20 no.3
    • /
    • pp.306-313
    • /
    • 2014
  • Nanoporous $TiO_2$ films are commonly used as working electrodes in dye-sensitized solar cells (DSSCs). So far, there have been attempts to synthesize films with various $TiO_2$ nanostructures to increase the power-conversion efficiency. In this work, vertically aligned rutile $TiO_2$ nanorods were grown on fluorinated tin oxide (FTO) glass by hydrothermal synthesis, followed by deposition of an anatase $TiO_2$ film. This new method of anatase $TiO_2$ growth avoided the use of a seed layer that is usually required in hydrothermal synthesis of $TiO_2$ electrodes. The dense anatase $TiO_2$ layer was designed to behave as the electron-generating layer, while the less dense rutile nanorods acted as electron-transfer pathwaysto the FTO glass. In order to facilitate the electron transfer, the rutile phase nanorods were treated with a $TiCl_4$ solution so that the nanorods were coated with the anatase $TiO_2$ film after heat treatment. Compared to the electrode consisting of only rutile $TiO_2$, the power-conversion efficiency of the rutile-anatase hybrid $TiO_2$ electrode was found to be much higher. The total thickness of the rutile-anatase hybrid $TiO_2$ structures were around $4.5-5.0{\mu}m$, and the highest power efficiency of the cell assembled with the structured $TiO_2$ electrode was around 3.94%.

Levels of Barriers to Pain Management of Cancer Patients and their Nurses (암 환자와 간호사의 통증관리 장애정도)

  • Yoo, Yang-Sook;Lee, Won-Hee;Cho, Ok-Hee;Lee, So-Woo
    • Journal of Hospice and Palliative Care
    • /
    • v.8 no.2
    • /
    • pp.224-233
    • /
    • 2005
  • Purpose: This study was conducted to provide basic data for developing an effective strategy for cancer pain management by comparing the levels of barriers to pain management of metastatic or advanced cancer patient and their nurses. Methods: The subject of this study were 155 patients who were treated for metastatic or advanced cancer at one of three hospitals in Seoul from January 2004 to January 2005, and 153 nurses who take care of those patients. The levels of barriers to pain management were measured using a tool developed by Gunnarsdottir et al. (2002), 27 questions on a six point scale. The levels of stresses were measured using a tool modified from a stress response measurement reported by Goh Gyung-bong et al. (2000), 27 questions on a five point scale. The levels of barriers in cancer patients were analyzed using t-test and ANOVA, while the data obtained from patients and nurses were compared by t-test. Results: Higher levels of barriers to pain management were found in three groups: 'less than middle school,' 'not treated with anti-cancer chemotherapy,' and 'ECOG of 2.' The level (2.55) of barriers to pain management in the patient group was higher than that (1.76) of the nurse group. Both of the two groups had high levels of barriers in two variables: 'There is a danger of becoming addicted to pain medicine.' and 'Using pain medicine blocks your ability to know if you have any new pain.' There was not a significant difference in the levels of stresses between the two groups. Conclusion: It was found that, for effective cancer pain management practices, it would be necessary to provide cancer patients and their nurses with education and training about pain management and related barriers.

  • PDF

Differential Diagnosis of Bicornuate and Septate Uterus : Is Comparison of Septal Signal Intensity on MR Image Useful\ulcorner (양각 자궁과 중격 자궁의 감멸 진단: 자기공명영상에서 자궁 격막 신호 강도의 비교는 유용한가\ulcorner)

  • 김종철;변재영;백승연
    • Investigative Magnetic Resonance Imaging
    • /
    • v.4 no.2
    • /
    • pp.107-112
    • /
    • 2000
  • Purpose : To evaluate the usefulness of comparison of the signal intensity of uterine septum in the differential diagnosis of bicornuate and septate uterus on magnetic resonance (MR) imaging. Materials and methods : Preoperative MR imaging findings of surgically proven 5 bicornuate and 6 septate uteri were retrospectively analyzed. Because preoperative differential diagnosis of both was possible in all cases in terms of the intercornual distance, external contour of uterine fungus, and divergent angle of two uterine cavities, these criteria were excluded in this study. The signal intensity of uterine septum in patients with bicornuate and septate uterus was analyzed on T1-weighted and fast spin echo T2-weighted images obtained in the axial and coronal planes, using a 1.5-T MR scanner. The signal intensity of uterine septum especially on T2-weighted images was compared with that of myometrium or junctional zone. Results : The signal intensity of uterine septum in patients with bicornuate uterus (n=5) and septate uterus (n=6) was similar to that of myometrium in all cases on T1-weighted images. The septum of bicornuate uterus (n=5) on fast spin echo T2-weighted images was isointense with myometrium in three and hypointense in two cases. The uterine septum of septate uterus (n=6) on T2-weighted images was isointense with myometrium in two, hypointense in two, and isointense with or more hypointense than junctional zone in two cases. No patient showed different signal intensity between upper and lower uterine septum. Conclusion : Because the MR signal intensity of the uterine septum in bicornuate or septate uterus is variable, it should not be used alone in the differential diagnosis of them. In these clinically important differentiation, therefore, comprehensive analysis of MR findings in terms of the external contour of uterine fundus, intercornual distance, divergent angle of two uterine cavities, in addition to the signal intensity of the uterine septum, should be considered.

  • PDF

Effect of the Consumer's Perception of the University Foodservice Quality on the Consumer Attitude (대학교 급식소의 급식서비스 품질에 대한 인식이 소비자태도에 미치는 영향)

  • Kim, Hyun-Ah
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.35 no.6
    • /
    • pp.815-822
    • /
    • 2006
  • The purposes of this study were to investigate the consumer's perception of the subject to manage the foodservice operation in the university, and to analyze the effects of consumer's perception of the university foodservice qualify on intent to revisit and intent to recommend. The questionnaires were distributed to 575 students in the K University located in Masan, who were sampled by proportionate stratified sampling method. The surveys were peformed from May 17 to June 2, 2005. The 566 questionnaires were responded, and 6 unusable questionnaires were excluded, then 560 were used for the final analysis (response rate: 97.4%). For the statistical analysis, SPSS (12.0) was used to conduct the descriptive analysis, factor analysis reliability analysis, and multiple regression analysis. The results of this study were as follows: First 254 respondants (47.3%) did not know that their foodservice operation was managed by contract foodservice company, and 374 students (66.8%) did not know the name of the contract foodservice company which runned their foodservice operation. Second, the food factor of university foodservice quality had a significant positive effect on intent to revisit (P<0.001), and the food factor of university foodservice quality also had a significant positive effect on Intent to recommend (p<0.001). It was concluded that as the food factor of university foodservice qualify Increased, the intent to revisit and the intent to recommend the university foodservice increased. So when university foodservice managers plan the foodservice operation strategy, they should focus on increasing the perception of customers' foodservice quality and also advertising contract foodservice company's brand name.

Application Study of $CO_2$ Snow Cleaning for Cleaning of Foreign Matter and Corrosion Products on Iron Artifacts ($CO_2$ Snow Cleaning 적용 철제유물 표면 이물질 제거 연구)

  • Lee, Eun-Ji;Cho, Nam-Chul;Lee, Jong-Myong;Yu, Jae-Eun
    • Journal of Conservation Science
    • /
    • v.27 no.3
    • /
    • pp.333-344
    • /
    • 2011
  • Cleaning of foreign matter and corrosion products on surface among conservation treatment of iron artifacts is an important part for looking up a original form. The sand blaster is the most popular equipment when it removes the foreign matter and corrosion products on iron artifacts surface. Current foreign matter and corrosion products equipment, which mostly uses, is sand blaster. Glass dust which sprayed from sand blaster is harmful and causing environmental pollution. In order to solve these problems, we investigated the $CO_2$ snow cleaning that use a eco-friendly equipment to apply for cleaning foreign matter and corrosion products on surface of iron artifacts. It examined by using sand blaster and $CO_2$ snow cleaning to aged steel coupon and iron artifacts. In case of aged steel coupon, the result showed that the sand blaster and $CO_2$ snow cleaning methods were similar to the degrees of cleaning foreign matter and corrosion products, through surface roughness, color measurement and SEM. $CO_2$ snow cleaning applied to aged steel coupons weren't worn out the surface in comparison with sand blaster by SEM. When applied to the iron artifacts, power nozzle of the $CO_2$ snow cleaning was an excellent cleaning effect that surface wern't worn out in comparison with sand blaster. And, it showed that internal structure change of metal was no found before and after cleaning by X-ray radiography. Consequently, we confirmed that cleaning of the sand blaster and power nozzle of $CO_2$ snow cleaning were similar to the effect. But, it's very careful to use this method because of high outlet pressure of power nozzle for applying to the iron artifacts. As a result of experiments, it could be found that the cleaning methods should be selected depending on internal state of the artifacts.

The immunogenicity and safety of three-component DTaP vaccine in Korean infants (우리나라 영아에서 3가 정제 백일해 항원 DTaP 백신의 면역원성 및 안전성)

  • Kang, Jin Han;Kim, Jong Hyun;Lee, Jung Hyun;Lee, Soo Young;Hong, Young Jin;Kim, Chang Hwi
    • Clinical and Experimental Pediatrics
    • /
    • v.50 no.4
    • /
    • pp.355-362
    • /
    • 2007
  • Purpose : We conducted the study to evaluate the immunogenicity and safety of three component DTaP vaccine ($Infanrix^{(R)}$) in a group of Korean healthy infants on a three-dose primary vaccination. And we compared the immunogenicity of this DTaP vaccine with two component DTaP vaccine which has been widely used in Korea. Methods : We enrolled one hundred fifty one healthy infants aged 8-9 weeks. These infants were vaccinated at age 2, 4 and 6 months of age with three component DTaP vaccine. Solicited adverse events were actively monitored for 72 hours following each vaccination, and all adverse events after each vaccination were observed for three weeks. Anti-diphtheria toxoid Ab., anti-tetanus toxoid Ab., anti-pertussis toxin Ab., anti-filamentous hemagglutinin Ab., and anti-pertactin Ab. were measured using ELISA for assessing immunogenicity of study vaccine in 60 infants. Immunogenicity analysis of two component DTaP vaccine was performed with same methods in 14 infants as control. Results : The seroconversion rates of anti-diphtheria toxoid Ab, anti-tetanus toxoid Ab. anti-filamentous hemagglutinin Ab. were 100% in both group. Seroconversion rate of anti-pertactin Ab in study group was 100%, but the rate in control group was 50%. However, geometric mean concentration of anti-pertussis toxin Ab. was higher in control group. Mild local and systemic reactions were observed within three days after vaccination, and no serious adverse events related study vaccine were happened during study period. Conclusion : Our study results suggest that three component DTaP vaccine ($Infanrix^{(R)}$) is a well-tolerable and high immunogenic vaccine, especially anti-Pertactin Ab. of the study vaccine is very immunogenic. It can be available as routine DTaP vaccination in our infants.