• Title/Summary/Keyword: 재료제거율

Search Result 160, Processing Time 0.032 seconds

Evaluation of the Removal Performance of Nitrogen Oxides of Foam Composites Using Activated Carbon and Titanium Dioxide (활성탄소와 이산화 타이타늄을 활용한 폼 복합체의 질소산화물의 제거 성능 평가)

  • Choi, Hyun-Chul;Choi, Young-Cheol
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.26 no.6
    • /
    • pp.120-127
    • /
    • 2022
  • Nitrogen oxide(NOx) is a major cause of air pollution, exists in the form of nitrogen monoxide and nitrogen dioxide, and is harmful to the human body. Recently, a number of studies to reduce NOx in the atmosphere have been conducted, and these efforts have been the same in the field of construction materials. It is known that NOx can be efficiently removed by using a photocatalytic reaction. In this study, the NOx removal performance of the foam composite using activated carbon(AC) and titanium dioxide(TiO2) was investigated. AC was used to enhance the photocatalytic reaction of TiO2 by increasing the internal specific surface area of the foam composite. In this study, foam composites were prepared using the substitution rate of AC as the main variable. The NOx removal performance of specimen was evaluated according to the test method presented in ISO-22197-1. The specific surface area of the foam composite showed a tendency to increase according to the AC content, but decreased at 15% or more. Also, when the AC substitution rate was 15%, the NOx removal efficiency was the highest.

The Salt Removal Efficiency Characteristics of Carbon Electrodes Using Fabric Current Collector with High Tensile Strength in a Capacitive Deionization Process (인장강도가 뛰어난 직물집전체를 이용한 탄소전극의 축전식 탈염공정에서의 제염효과)

  • Seong, Du-Ri;Kim, Dae Su
    • Korean Chemical Engineering Research
    • /
    • v.58 no.3
    • /
    • pp.466-473
    • /
    • 2020
  • Fabric current collector can be a promising electrode material for Capacitive Deionization (CDI) system that can achieve energy-efficient desalination of water. The one of the most attractive feature of the fabric current collector is its high tensile strength, which can be an alternative to the low mechanical strength of the graphite foil electrode. Another advantage is that the textile properties can easily make shapes by simple cutting, and the porosity and inter-fiber space which can assist facile flow of the aqueous medium. The fibers used in this study were made of woven structures using a spinning yarn using conductive LM fiber and carbon fiber, with tensile strength of 319 MPa, about 60 times stronger than graphite foil. The results were analyzed by measuring the salt removal efficiency by changing the viscosity of electrode slurry, adsorption voltage, flow rate of the aqueous medium, and concentration of the aqueous medium. Under the conditions of NaCl 200 mg/L, 20ml/min and adsorption voltage 1.5 V, salt removal efficiency of 43.9% in unit cells and 59.8% in modules stacked with 100 cells were shown, respectively. In unit cells, salt removal efficiency increases as the adsorption voltage increase to 1.3, 1.4 and 1.5 V. However, increasing to 1.6 and 1.7 V reduced salt removal efficiency. However, the 100-cell-stacked module showed a moderate increase in salt removal efficiency even at voltages above 1.5 V. The salt removal rate decreased when the flow rate of the feed was increased, and the salt removal rate decreased when the concentration of the feed was increased. This work shows that fabric current collector can be an alternative of a graphite foil.

Effect of Current Density on Material Removal in Cu ECMP (구리 ECMP에서 전류밀도가 재료제거에 미치는 영향)

  • Park, Eunjeong;Lee, Hyunseop;Jeong, Hobin;Jeong, Haedo
    • Tribology and Lubricants
    • /
    • v.31 no.3
    • /
    • pp.79-85
    • /
    • 2015
  • RC delay is a critical issue for achieving high performance of ULSI devices. In order to minimize the RC delay time, we uses the CMP process to introduce high-conductivity Cu and low-k materials on the damascene. The low-k materials are generally soft and fragile, resulting in structure collapse during the conventional high-pressure CMP process. One troubleshooting method is electrochemical mechanical polishing (ECMP) which has the advantages of high removal rate, and low polishing pressure, resulting in a well-polished surface because of high removal rate, low polishing pressure, and well-polished surface, due to the electrochemical acceleration of the copper dissolution. This study analyzes an electrochemical state (active, passive, transpassive state) on a potentiodynamic curve using a three-electrode cell consisting of a working electrode (WE), counter electrode (CE), and reference electrode (RE) in a potentiostat to verify an electrochemical removal mechanism. This study also tries to find optimum conditions for ECMP through experimentation. Furthermore, during the low-pressure ECMP process, we investigate the effect of current density on surface roughness and removal rate through anodic oxidation, dissolution, and reaction with a chelating agent. In addition, according to the Faraday’s law, as the current density increases, the amount of oxidized and dissolved copper increases. Finally, we confirm that the surface roughness improves with polishing time, and the current decreases in this process.

Comparison of energy efficiency by electrode materials and structure in bench scale bioelectrochemical anaerobic digestion (Bench scale 생물전기화학적 혐기성소화에서 전극재질 및 구조에 따른 에너지효율 비교)

  • Yang, Hyeon Myeong;Cheon, A In;Kim, Min Ji;Cha, Ji Hwan;Jun, Hang Bae
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2022.05a
    • /
    • pp.396-396
    • /
    • 2022
  • 생물전기화학적 혐기성소화(Bioelectrochemical anaerobic digestion; BEAD)는 소량의 전압공급을 통해 고농도 하·폐수의 효과적인 처리 및 에너지 회수가 가능한 처리방법으로, 기존 하·폐수처리공정(활성슬러지 및 그 변법)에서 벗어나기 위한 방법 중 하나로 연구되고 있지만, 내부저항 및 전극구조에 따른 물질전달저해로 인해 소규모 연구 위주로 진행되었다. 하지만 stainless steel(SS) 등 내부저항을 완화할 수 있는 전극재료 및 전극구조 개선 연구가 진행됨에 따라 BEAD 적용규모가 증가하는 추세이며, 본 연구에서는 100 L의 용량에서 전극재질 및 구조에 따른 적용적합성을 에너지효율 비교를 통해 평가하였다. 반응조는 비교를 위한 AD, 반응조 내부에 전극을 설치한 BEAD, 반응조 외부에 전극이 포함된 반응조를 추가한 ABEAD로 구성하였으며, AD 및 BEAD는 기계적 교반, ABEAD는 기계적 교반 및 펌프를 통한 bulk 용액 순환으로 물질전달이 이뤄졌다. 또한 BEAD는 탄소계 전극, ABEAD는 SS계 전극을 사용하였으며 두 반응조 모두 0.4 V의 전압을 공급하였다. 실험조건은 유효용량 100 L, 유기물부하율 3 kg/m3/d, HRT 20 days 및 중온소화(35℃)으로 운전하였다. 실험결과 AD, BEAD 및 ABEAD의 유기물제거율은 각각 평균 68.1 %, 68.9 %, 74.9 %로 전극 및 반응조의 분리를 통해 물질전달을 개선한 ABEAD에서 증가하였다. 에너지 생성량의 경우 AD에 비해 BEAD는 평균 229 kJ/d, ABEAD는 309 kJ/d가 추가 생성되었으며 유기물제거율이 높은 ABEAD에서 더 높은 에너지생산이 이뤄졌다. 마지막으로 전압공급으로 인한 에너지소비량은 BEAD는 평균 3.4 kJ/d, ABEAD는 평균 0.9 kJ/d로 전극의 낮은 생물적합성으로 인해 전극에서의 생화학반응이 적은 ABEAD가 에너지소비량이 낮았다. 따라서 본 연구에서는 SS 전극의 사용가능성 및 전극구조 개선에 따른 에너지효율성 향상을 확인할 수 있었으며, 추후 연구에 활용할 수 있을 것으로 기대된다.

  • PDF

Improvement of Dry-blasting Efficiency for Ballast used as Aggregate of Paved Track (포장궤도 골재용 도상자갈의 건식 블라스팅 효율 향상 연구)

  • Lee, Il-Wha
    • Journal of the Korean Society for Railway
    • /
    • v.13 no.1
    • /
    • pp.78-83
    • /
    • 2010
  • On the paved track, the ballast is used as aggregate for the filling layer using the pre-packed concrete technique. The most important condition of aggregate is adhesive strength with mortar. To satisfy this condition, surface of aggregate should be cleaned by water or others. In a paved-track method to be introduced domestically, an environment-friendly dry-washing technology which will replace the water-washing method has been developed. A dry-washing method was designed to blast the crushed weight material with a diameter of 0.3~0.5mm at high pressure to peel the surface of the aggregate. The study was intended to enhance the washing efficiency of dry-blasting technology and to that end, the tests including blasting material, content of fine aggregate depending on time elapsed, content of chloride, LA abrasion rate and compressive strength were conducted to recommend the efficient washing material and the process.

A Study on the Electrochemical Reaction of Metal at Electrolyte (전해액에서 금속막의 전기화학적 반응 고찰)

  • Lee, Young-Kyun;Park, Sung-Woo;Han, Sang-Jun;Lee, Sung-Il;Choi, Gwon-Woo;Lee, Woo-Sun;Seo, Yong-Jin
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.06a
    • /
    • pp.88-88
    • /
    • 2007
  • Chemical mechanical polishing (CMP) 공정은 그 어원에서 알 수 있듯이 슬러리의 화학적인 요소와 웨이퍼에 가해지는 기계적 압력에 의해 결정되는 평탄화 기술이다. 최근, 금속배선공정에서 높은 전도율과 재료의 값이 싸다는 이유로 Cu률 사용하였으나, 디바이스의 구조적 특성을 유지하기 위해 높은 압력으로 인한 새로운 다공성 막(low-k)의 파괴와, 디싱과 에로젼 현상으로 인한 문제점이 발생하게 되었다. 이러한 문제점을 해결하고자, 본 논문에서는 Cu 표면에 Passivation layer를 형성 및 제거하는 개념으로 공정시 연마제를 사용하지 않으며, 낮은 압력조건에서 공정을 수행하기 위해, 전해질의 농도 변화에 따른 선형추의전압전류법과 순환전압전류법을 사용하여 전압활성화에 의한 전기화학적 반응이 어떤 영향을 미치는지 연구하였다.

  • PDF

The Relation of Soybean Seedcoat Mottling with Podding Location and Seed Transmissibility in Soybean Mosaic Virus (대두모자이크바이러스에 의한 결협절위별 갈반립의 형성과 바이러의 종자전염)

  • Oh, Jeung-Haing
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.29 no.3
    • /
    • pp.280-284
    • /
    • 1984
  • Association of SMV infection in soybean plants with seedcoat mottling and with seed transmission of SMV was examined. Seedcoat mottling was increased positively in proportion to the SMV severity in variety Clark. No correlation was found between the incidence of mottled seed and the seed's position on the plant. Susceptible variety with virus symptoms gave rise to mottled seeds but only a small percentage of these mottled seeds could transmit the virus. SMV could be transmitted even by nonmottled seeds harvested from SMV infected plants in similar rate with mottled seed. It seemed that the amount of mottled seed could be used as an indicator of the amounts of SMV infection in a seed production field.

  • PDF

Collecting of Hanji Fibrous Sludge with Surfactant (계면활성제를 이용한 한지 섬유질 슬러지의 제거)

  • Choi, Hee-Seon;Kim, Tai-Jin
    • Analytical Science and Technology
    • /
    • v.14 no.2
    • /
    • pp.167-172
    • /
    • 2001
  • The technique that could collect efficiently the hanji fibrous sludge from wastewater using surfactants was developed. When fibrous sludge of which concentration was about 80mg/L, was floated and collected, the optimum concentration of sodium oleate, the pore size of glass filter and the air flow rate were 10mg/L, $5-10{\mu}m$ and 200mL/min., respectively. The behavior of sodium oleate might be interfered by polyvalent cations such as $Ca^{2+}$. But when the concentration of $Ca^{2+}$ was less than 100mg/L, the interference effect did not appear. And when a typical cationic surfactant, cetyltrimethylammonium bromide(CTAB), was used, the collecting yield was less than that of sodium oleate, and the amount of foam was higher than sodium oleate. When 1mg/L of CTAB was added to the hanji sludge sample contained 1mg/L of $PAMID^{(R)}$, a dispersant, fibrous sludge was effectively coagulated, the flotation time was very short and the collecting yield was above 95%. But in the case, sodium oleate was inefficient.

  • PDF

Further Treatment of Constructed Wetland Effluent using Filter Materials (여재를 이용한 인공습지 유출수 추가처리)

  • Haam, Jong-Hwa;Kim, Hyung-Joong;Kim, Yeong-Kyung
    • Journal of Wetlands Research
    • /
    • v.11 no.2
    • /
    • pp.9-16
    • /
    • 2009
  • Further treatment facility using various filter materials was evaluated to treat effluent of constructed wetland. Further treatment facility was installed with 1m length in outlet of 3 constructed wetland (unplanted constructed; reed bed constructed wetland; cattail bed constructed wetland) using 3 filter materials (slag, activated carbon, oyster shell). Flow rate of three further treatment facility was 63 $m^3$/day (slag), 19 $m^3$/day (activated carbon), and 81 $m^3$/day (Oyster shell). COD removal rate of slag, activated carbon, and oyster shell was 6 %, 24 %, 1 %, and removal mass was 32 g/day, 30 g/day, and 5 g/day, respectively. All of further treatment facility was effective to removal organic materials. T-N and T-P removal rate of activated carbon was 24 % and 4 %, and slag and oyster shell was not effective to remove T-N and T-P. Overall, further treatment facility was effective to remove organic mater, constructed wetland combined with further treatment facility can remove nutrient and organic matters effectively.

  • PDF

Adsorption of Formaldehyde by Wood Charcoal-Based Building Materials (목탄계 건축자재에 의한 포름알데히드 흡착)

  • Lee, Oh-Kyu;Choi, Joon-Weon;Jo, Tae-Su;Paik, Ki-Hyon
    • Journal of the Korean Wood Science and Technology
    • /
    • v.35 no.3
    • /
    • pp.61-69
    • /
    • 2007
  • The building materials used for improving indoor air quality, the wood charcoal mixed with cement mortar or natural water paint were examined for their potential removing ability of formaldehyde. After the reaction of samples with formaldehyde in the glass flasks designed in our lab, the remaining formaldehyde was collected using DNPH (2,4-dinitrophenyl hydrazine) cartridges, and their concentration was determined using HPLC. From the results, it was found that the removing amount of formaldehyde per one gram sample containing 5, 10, or 15% of wood charcoal was more than three times compared to that of control (100% cement mortar or water paint). Their elimination percentages from the initial formaldehyde was about 80~90%. The experimental results for wood charcoal-water paint showed a similar trend with those of wood charcoal-cement mortar samples. Their elimination percentages from the initial formaldehyde was about 90%. It is proposed that formaldehyde is adsorbed on the adsorbed 'O' or 'OH' groups in the graphene layers formed through the re-arrangement of lignocellulose in the wood during the carbonization procedure.