• Title/Summary/Keyword: 재난 취약 건축물

Search Result 18, Processing Time 0.022 seconds

A Study to Prevent the Fire in Residential Buildings (주거용 건축물의 화재 예방에 관한 고찰)

  • Park, Kyong-Jin;Kim, Hye-ree;Lee, Bong-Woo;Park, Shin-young
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.23 no.2_2
    • /
    • pp.307-312
    • /
    • 2020
  • This study presents problems and improvement measures for the supply rate of single-alarm detector and fire extinguisher installed in households. Statistics from the NFDS show that 18 percent of all fires and 45 percent of deaths occurred in residential buildings over the past eight years. It was less than 60% that households be equipped rate of basic fire-fighting systems by 2019. In this study, I analyzed the law and statistics of fire to devise a method for fire safety. I proposed that the basic fire-fighting systems is be equipped in households. Like this : First, a free distribution policy for the over 60 years of age and Areas where is fire engine difficult to enter. Second, the policy of adopting safety pay in disaster. Third, the policy of expanding supply through the revision of the Licensed Real Estate Agents Act. Fourth, the policy of self-regulating installation by safety education and set up a data base system. Fifth make a law of household's National Fire Safety Standards.

A Study on the Effect of Fire Heat on the Durability of Concrete Structures Repaired and Reinforced with Epoxy Resin (화열(火熱)이 에폭시수지로 보수·보강된 콘크리트 구조체의 내구성에 미치는 영향에 관한 연구)

  • Tai Kwan Cho
    • Journal of the Society of Disaster Information
    • /
    • v.19 no.1
    • /
    • pp.138-145
    • /
    • 2023
  • Purpose: In accordance with the increase in the number of buildings repaired and reinforced following deterioration from when a fire occurs in a previously reinforced building, the impact on the structure after the fire is analyzed to establish standards for repair and reinforcement measures. Method: After curing for 28 days, the process was to measure the compressive strength and induce destruction through a compressor, repair and reinforce it with epoxy, and conduct a re-compressive strength test on some specimens after curing for 3 days to understand the degree of strength restoration. The rest of the repaired and reinforced specimens as well as the unrepaired and unreinforced specimens were then put into an oven and heated according to the temporal and temperate conditions listed below, and then the compressive strength was tested to estimate the impact of fire. Result: After reinforcing the yielded specimen with epoxy, the process was to then put it in an oven and heat it at different temperatures over time. It was found that there was a decrease in the strength of the reinforcement more than that of the actual specimen. Conclusion: Based on this, it was found that a building repaired and reinforced with epoxy resin is actually more dangerous than a general unrepaired building when it is damaged by fire, and thus, that it must be prepared for fire vulnerabilities.

An Experimental Study on the Influence of the Spread of Firebrand on Building Exterior Materials and Roofing Materials in Urban Areas (도심지 인접 산불의 불티 확산이 건축물 외장재와 지붕재에 미치는 영향에 관한 실험적 연구)

  • Min, Jeong-Ki
    • Journal of the Society of Disaster Information
    • /
    • v.17 no.3
    • /
    • pp.617-626
    • /
    • 2021
  • Purpose: The purpose of this study is to evaluate the fire srpead risk of building exterior and roofing materials due to the firebrand of forest fire occurring in the urban areas. Method: In order to achieve this research purpose, by selecting building materials used for exterior and roofing materials of buildings, the time to ignition, total heat release, and heat release rate were investigated, and a forest fire firebrand system was established to the possibility of fire spread was confirmed. Result: As a result of the cone calorimeter test, the roofing material had a similar or faster ignition time due to radiant heat compared to the exterior material with the steel plate exposed to the outside, and showed a higher heat release rate and total heat release than the exterior material. Although it was affected by the flammable material, it was confirmed that it did not spread easily due to the limited amount of combustible material, and carbonization marks appeared inside. Conclusion: The cone calorimeter test method has been shown to be useful in understanding the combustion characteristics of building materials by radiant heat, but the fire spread due to a firebrand in a forest fire is directly affected by the flame due to the ignition of surrounding combustibles, so finding a direct correlation with the cone calorimeter method is difficult. It is judged that the roof material may be more vulnerable to the spread of fire due to the fire than the exterior material.

Analysis of Spatial Characteristics of Old Building Districts to Evaluate Fire Risk Factors (화재 위험요소의 도출을 위한 노후건축지구의 공간구성 특성분석)

  • Son, Byeung-Hun;Kang, Kyung-Ha;Ryu, Jung-Rim;Roh, Seung-Jun
    • Journal of the Korea Institute of Building Construction
    • /
    • v.22 no.1
    • /
    • pp.69-80
    • /
    • 2022
  • The proportion of buildings over 30 years old in Korea has increased, from 29.0% in 2005 to 37.8% in 2019. These old buildings were built during a time in which there was a lack of building-related safety standards in areas such as fire safety performance. Worse, during their years of use, many such old buildings have had illegal changes and extensions made, making them more vulnerable in terms of safety. Fire safety investigations are being conducted to prevent large-scale disasters in multi-use buildings, but no investigation has been conducted at the regional district level, where small-scale old buildings are concentrated. Therefore, to identify fire risk factors in the old building district where old buildings are concentrated, the composition characteristics of the buildings were first analyzed. To examine the spatial characteristics of old building districts in order to derive fire risk factors, the results of this analysis based on the structure, use, roof type, and year of approval for use are as follows. It was found through our analysis that as of the date of approval for the use of the building, the main structure of the building has the greatest impact.

Fire Fragility Analysis of Steel Moment Frame using Machine Learning Algorithms (머신러닝 기법을 활용한 철골 모멘트 골조의 화재 취약도 분석)

  • Xingyue Piao;Robin Eunju Kim
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.37 no.1
    • /
    • pp.57-65
    • /
    • 2024
  • In a fire-resistant structure, uncertainties arise in factors such as ventilation, material elasticity modulus, yield strength, coefficient of thermal expansion, external forces, and fire location. The ventilation uncertainty affects thefactor contributes to uncertainties in fire temperature, subsequently impacting the structural temperature. These temperatures, combined with material properties, give rise to uncertain structural responses. Given the nonlinear behavior of structures under fire conditions, calculating fire fragility traditionally involves time-consuming Monte Carlo simulations. To address this, recent studies have explored leveraging machine learning algorithms to predict fire fragility, aiming to enhance efficiency while maintaining accuracy. This study focuses on predicting the fire fragility of a steel moment frame building, accounting for uncertainties in fire size, location, and structural material properties. The fragility curve, derived from nonlinear structural behavior under fire, follows a log-normal distribution. The results demonstrate that the proposed method accurately and efficiently predicts fire fragility, showcasing its effectiveness in streamlining the analysis process.

Development of A Comprehensive Diagnosis Index for Disasters in Declining Areas and Comparison of Risks between Regions: A case of Seoul (쇠퇴지역 재난·재해 종합진단지수 개발과 지역간 위험성 비교·분석 - 서울시 사례 -)

  • Im, Hyojin;Ahn, Minsu;Yi, Changhyo;Lee, Sangmin;Lee, Jae-Su
    • Journal of the Korean Regional Science Association
    • /
    • v.37 no.4
    • /
    • pp.33-47
    • /
    • 2021
  • In urban declining areas, the population is decreasing, and drying environments such as buildings and facilities are aging. Therefore, it is vulnerable in the event of disaster, and recovery takes a lot of time and money. The purpose of this study is to develop an evaluation technique for comprehensively diagnosing disasters in declining areas and to present implications through case analysis. Evaluation indicators were selected to calculate the comprehensive diagnosis index of disasters, and weights were calculated for each class, including disaster types, components, and evaluation indicators, through Analytic Hierarchy Process analysis. The comprehensive diagnoses index for each type of disaster was calculated with the calculated weight, and the risk according to the level of urban decline was analyzed. As a result of analyzing Seoul as a case area, it was analyzed that the overall risk of disasters was high in southern regions such as Seocho-gu, Dongjak-gu, Geumcheon-gu, and Gangseo-gu, and relatively low in downtown and northern Seoul, parks and green areas. The results of this study are of academic significance in that they presented a comprehensive diagnostic index evaluation system and technique for each type of disaster, including natural and social disasters.

An Experimental Study on the Reinforcement of Low-Rise RC Structure for Seismic Performance (저층 RC 건물의 내진성능 보강에 관한 실험적 연구)

  • Kim, Dongbaek;Lee, Byeonghoon;Kwon, Soondong;Lee, Induk
    • Journal of the Society of Disaster Information
    • /
    • v.12 no.2
    • /
    • pp.144-149
    • /
    • 2016
  • Nowaday, most of the low-rise concrete structures which have less than five stories were built before the intensified seismic code was established 2005. According to the fact that our country is not a safety zone ay more, studies are need to reinforce the seismic performance of that structures. The basic frame of low-rise structure are consist of beams and columns with partition walls, therefore that are very weak about secondary wave of earthquake because of the high stiffness. The partition wall are consist of open channel for sunlight or ventilation and intermediate wall. The intermediate walls will enhance the stiffness of columns, but will cause shear failure with short column effects because of the reduced effective depth. But we don't have studies and adequate design code for partition wall effects, therefore some more studies are need for these facts.

Utilization and Excavation Practices of Fire-Fighting Vulnerable Zone Model (소방취약지 모델의 활용 및 적용사례 발굴)

  • Choi, Gap Yong;Chang, Eun Mi;Kim, Seong Gon;Cho, Kwang-Hyun
    • Spatial Information Research
    • /
    • v.22 no.3
    • /
    • pp.79-87
    • /
    • 2014
  • In order to foster rapid disaster response and public life protection, National Emergency Management Agency has been trying to spread 'Emergency Rescue Standard System' on a national scale since 2006. The agency has also intensified management of firefighter's safety on disaster site by implementing danger predication training, specialized training and education and safety procedure check as a part of safety management officer duties. Nevertheless, there are limitations for effective fire fighting steps, such as damage spreading and life damage due to unawareness of illegal converted structure, structure transformation by high temperature and nearby hazardous material storage as well as extemporary situation handling endangered firefighter's life. In order to eliminate these limitations there is a need for an effort and technology application to minimize human errors such as inaccurate situational awareness, wrong decision built on experience and judgment of field commander and firefighters. The purpose of this study is to propose a new disaster response model which is applied with geospatial information. we executed spatial contextual awareness map analysis using fire-fighting vulnerable zone model to propose the new disaster response model and also examined a case study for Dalseo-gu in Daegu Metropolitan City. Finally, we also suggested operational concept of new proposed model on a national scale.