• Title/Summary/Keyword: 재난 대피

Search Result 237, Processing Time 0.022 seconds

Status of Local Disaster Prevention by Regional Types - Focusing on Gangwon-do - (지역유형별 지역방재력에 관한 실태분석 - 강원도를 중심으로 -)

  • Kim, Kyoung-Nam;Kwon, Gun-Ju;Back, Min-Ho
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.10 no.4
    • /
    • pp.33-46
    • /
    • 2010
  • The 14 cities and guns within Gangwon-do were divided into three regions (urban-rural-integrated type, urban type, and ruralcoastal type), and local voluntary disaster prevention organizations in those regions were surveyed as sample groups. As a result, the urban-rural-integrated type and the urban type were found to be lower than the rural-coastal type in all domains including recognition of disaster crisis, evacuation guidance, preparation of voluntary evacuation, maintenance of disaster prevention system, surveillance & guard, and information delivery. In particular, three types had higher information delivery but considerably lower preparation of voluntary evacuation. As for information delivery, foundations for rapid delivery of disaster information due to establishment and extension of systems for forecasting and warning of local governments were prepared, but as for preparation of voluntary evacuation, it is needed not only to perform consistent training and promotion for preparation for disasters for residents to accurately understand status of disasters but to take measures to secure safe places for evacuation beforehand.

Analysis on Activation Characteristic of Heat Detectors in a Compartment Fire (실내화재에서의 열감지기 동작특성 분석)

  • Ryu, Hocheol
    • Journal of the Society of Disaster Information
    • /
    • v.10 no.4
    • /
    • pp.598-608
    • /
    • 2014
  • The first operation of alarm system starts at a detector. And the largest effect is produced on the operation of detector by the fire source position and installation position. Nevertheless, the Korean standard for the installation of detector only specifies matters of fire detector installation according to area and height, without consideration of installation position and fire source position. Therefore, this study carried out a fire test in consideration of detector installation position and fire source position (5 places) in order to minimize casualties owing to the fast operation of fire detector when a fire occurred. Considering that it took the longest time for a detector close to a wall to work in the results of this test, it was possible to find that a minimum clearance to the wall was required.

Analysis of A Gas Explosion-Related State Compensation Case (가스폭발 사고와 관련된 국가배상 사례의 분석)

  • Lee, Euipyeong
    • Journal of the Society of Disaster Information
    • /
    • v.16 no.1
    • /
    • pp.44-59
    • /
    • 2020
  • This study analyzed a gas explosion accident. A gas smell from a underground coffee shop in the two-story building was reported to 119. A fire brigade was turned out, turned off the main valve of LPG gas cylinder on the roof, and checked the turning off of middle valve in the coffee shop. The fire brigade required a gas supplier and gas installer who arrived at the spot to take safety actions. Gas explosion occurred seven minutes after the fire brigade was withdrawn and two people died and 21 people were injured. A court decided that because the causes for gas explosion were not found, compensation responsibility could not be charged with the gas supplier, the gas installer, or Korea Gas Safety Corporation. In this reason, the court judged that only the fire brigade who was withdrawn without taking safety actions shall compensate victims or bereaved families. Therefore, fire brigades who turn out after a 119 report of a gas leak should take safety actions such as escaping people or preventing people's access and ventilating and be withdrawn when there is no possibility of fire or explosion.

Optimal Route Discovery System for Emergency Escape from Disaster Situations (재난 상황 시 탈출을 위한 최적 경로 탐색 시스템)

  • Kang, Moo-Bin;Joo, Yang-Ick
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2016.05a
    • /
    • pp.448-449
    • /
    • 2016
  • Enlargement and complexification of current structures increase the expected casualty in case of accident in those e.g., fire. In that case, there only have been basic instructions such as announcement of that situation, alarm bell, exit signs, etc. but any guidance to lead to proper escape route was not been provided so far. To tackle the problem, several schemes have been proposed. However, various risk factors were not considered and route discovery performance must be improved to be applied to structures. Therefore, this paper proposes an optimal route discovery system for emergency escape from disaster situations which takes into account various possible risk factors and enhances the searching efficiency by using the $A^{\ast}$ algorithm. Performance evaluation by computer simulation shows that the proposed scheme effectively leads to safe escape route.

  • PDF

A study of on the occupant movement speed during emergency evacuations for the evacuation safety assessment of domestic buildings (국내 건축물의 피난안정성평가를 위한 비상대피 시 재실자 이동속도에 관한 연구)

  • Youn, Ho-Ju;Hwang, Eunkyung
    • Journal of the Society of Disaster Information
    • /
    • v.9 no.3
    • /
    • pp.332-338
    • /
    • 2013
  • Recently in Korea, in order to ensure evacuation safety within buildings, reviewing and evacuation assessment using computer simulations has been performed from the planning and design stages. Since the results from the assessment mainly depends on the initial values of input elements, it is important to establish element specific data. Nevertheless evacuation related experiments and research are still insufficient to apply overseas standards to domestic conditions. This study intended to conduct a experiment on evacuation movement speed by age as part of element-specific data construction for domestic occupant movement speed. After analyzing domestic and overseas studies on evacuation movement speed, we conducted the experiment of evacuation movement speed for 134 people. Then, by carrying out a comparative analysis of the results of the movement speed obtained from the experiment with overseas movement speeds, we followed the validation procedures of the experimental results under domestic evacuation conditions. The data derived from the experiment is expected to serve as a basis for the movement speed of domestic evacuation safety assessment.

Safety Monitoring System of Structures Using MEMS Sensor (MEMS 센서기반의 구조물의 안전 모니터링 시스템)

  • Lim, Jaedon;Kim, Jungjip;Hong, Dueui;Jung, Hoekyung
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.22 no.10
    • /
    • pp.1307-1313
    • /
    • 2018
  • In recent years, there have been frequent occurrences of collapsing buildings and tilting accidents due to frequent earthquakes and aging of buildings. Various methods have been proposed to prevent disasters on these buildings. In this paper, we propose a system that provides an indication of anomalous phenomena such as collapse and tilting of buildings by real-time monitoring of IoT(Internet of Things) based architectural anomalies. The MEMS sensor is based on the inclinometer sensor and the accelerometer sensor, transmits the detected data to the server in real time, accumulates the data, and provides the service to cope when the set threshold value is different. It is possible to evacuate and repair the collapse and tilting of the building by warning the occurrence of the upper threshold event such as the collapse and tilting of the building.

A collaborative Serious Game for fire disaster evacuation drill in Metaverse (재난 탈출 협동 훈련 기능성 게임의 메타버스 플랫폼 구현)

  • Lee, Sangho;Ha, Gyutae;Kim, Hongseok;Kim, Shiho
    • Journal of Platform Technology
    • /
    • v.9 no.3
    • /
    • pp.70-77
    • /
    • 2021
  • The purpose of Serious games in immersive Metaverse platform to provide users both fun and intriguing learning experiences. We proposes a serious game for self-trainable fire evacuation drill with collaboration among avatars synchronized with multiple trainees and optionally with real-time supervising placed at different remote physical locations. The proposed system architecture is composed of wearable motion sensors and a Head Mounted Display to synchronize each user's intended motions to her/his avatar activities in a cyberspace in Metaverse environment. The proposed system provides immersive as well as inexpensive environments for easy-to-use user interface for cyber experience-based fire evacuation training system. The proposed configuration of the user-avatar interface, the collaborative learning environment, and the evaluation system on the VR serious game are expected to be applied to other serious games. The game was implemented only for the predefined fire scenario for buildings, but the platform can extend its configuration for various disaster situations that may happen to the public.

Current Status and Planning Improvement through Case Studies of Nursing Homes in the View of Disaster Safety - Focused on the Cases of Cheongju City, Chungbuk - (재난안전 관점의 노인요양시설 사례연구를 통한 현황 및 개선방안 - 충북 청주시 사례를 중심으로 -)

  • Choi, Yu-Ra;Kim, Mi-Kyung
    • Journal of the Architectural Institute of Korea Planning & Design
    • /
    • v.36 no.5
    • /
    • pp.41-51
    • /
    • 2020
  • As there are the elderly who have difficulty in evacuating themselves, it is necessary to develop architectural and institutional planning for nursing homes that can minimize disaster damage. The purpose of this study was to suggest the improvement plan by grasping the current status of nursing homes on planning aspects such as floor plan type, spatial layout, and evacuation route through 14 case studies in Cheongju city in terms of disaster safety. The results of this study were as follows; the most common plan type was the grouped-corridor type difficulty in securing evacuation routes. The circulation corridor type is need to be considered because it is possible not only to secure evacuation and nursing routes, but also to create a hanging around corridor for the elderly with dementia. Second, if there is a risk of flooding due to the location, the living room should be placed on the 2nd floor or more. In particular, a kitchen should be placed not adjacent to the entrance and the vertical evacuation route. Third, the horizontal evacuation route should be arranged differently depending on the floor plan type. For vertical evacuation routes, it is necessary to install outdoor stairs or ramps considering the evacuation characteristics of the elderly. In addition, the institutional aspects should be considered to ensure the safety of disasters.

A Study on the Performance Improvement Plan of Inflowing Air Emission (유입 공기의 배출 성능 개선방안에 관한 연구)

  • Lee, Hye-Young
    • Journal of the Society of Disaster Information
    • /
    • v.18 no.2
    • /
    • pp.241-251
    • /
    • 2022
  • Purpose: In the event of a fire in a high-rise building, if the smoke control area is not effectively protected, smoke or flames enter the stairwell, making it difficult to evacuate. When inflowing air is discharged from a closed corridor, a negative pressure is formed in the corridor, the pressure in the smoke control area becomes excessively high, and the force required to open the door during evacuation is exceeded. Also, if the air introduced into the hallway is not exhausted, the smoke may flow back into the smoke control area. This paper tried to identify the problems caused by the inflowing air and to find out how to improve the performance. Method: Using the CONTAM program, simulations were performed with the basic conditions and the modified conditions. Result: If the inflowing air was discharged from the sealed corridor, overpressure occurred in the Smoke Control Area and exceeded the opening force, and the prevent smoke backflow was insufficient in the layer where the inflowing air was not discharged. Conclusion: "Differential pressure exhaust damper" application, simultaneous opening of two exhaust dampers, and automatic window installation between corridors and outdoors improved the exhaust performance of inflowing air.

A Study on the Strength Properties of FRP Member for Making Personal Disaster Shelters in Rural Area (농산촌 재난대피시설 제작을 위한 FRP 부재의 강도특성에 관한 연구)

  • Kim, Jung Meyon;Hwang, Dea Won;Lim, Hyun Taek;Park, Sung Yong;Yeon, Kyu Seok;Kim, Yong Seong
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.58 no.2
    • /
    • pp.73-82
    • /
    • 2016
  • This study is about development of personal disaster shelters for minimization of the casualties caused by the landslide and steep slope collapse. The objectives of present research is the selection of disaster evacuation facilities utilizing FRP (Fiber Reinforced Plastic) material. For the proper assessment of FRP member, several layers by strength test and the three-dimensional numerical analysis of these FRR member was carried out. As a result, the personal disaster evacuation facility utilizing FRP materials, was found to be of a material that is able to protect the weak person at the time of the collapse of the landslides and steep slopes.