• Title/Summary/Keyword: 재난방재

Search Result 890, Processing Time 0.029 seconds

Tele-operation System of Unmaned Fire Truck for Real-time Fire Suppression (실시간 화재진압을 위한 원격조종 무인소방 시스템)

  • Kang, Byoung Hun;Lee, Seung-Chol
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.22 no.6
    • /
    • pp.1-6
    • /
    • 2022
  • In this research, we suggest a real-time tele-driving system for unmanned fire truck control using the LTE communication system. The operator located in the safe area could drive the unmaned fire truck by implementing the secure tele-operation in case of the emergencies and disaster situation. A prototype of the unmaned fire truck was developed with a fire canon, a high pressure pump, a ball valve and a horse reel. The effect of time delay and FPS was quantified depending on the image sizes and the effective system for realtime tele-operation was suggested. To verify the suggested system, the test was performed between an operator and an unmanned fire truck which is approximately 30km apart. In this research, the immersion tele-driving system is suggested for real-time fire suppression with a 120ms time delay using LTE communication.

Applicability Evaluation of One- and Two-dimensional Flood Inundation Analysis Models to Establish an Emergency Action Plan for Agricultural Reservoirs (농업용저수지 EAP 수립을 위한 1·2차원 홍수범람해석모형의 적용성 평가)

  • Lee, Dae Eop;Kim, Jae Young;Lee, Gi Ha;Jung, Sung Ho;Yeon, Min Ho
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2021.06a
    • /
    • pp.351-351
    • /
    • 2021
  • 저수지에 대한 비상대처계획수립은 최근 기상이변 등에 따른 대규모 호우가 빈번히 발생하고 있을 뿐만 아니라 세계 도처에서 대규모 지진 등으로 많은 인명과 재산 피해가 속출함에 따라 지진 및 이상홍수에 대한 저수지의 안정성 평가를 수행하고 저수지 지점에서 발생할 수 있는 천재지변 또는 예상치 못한 대규모 재해에 효율적으로 대처하기 위한 비상상황의 등급 및 위험수준을 체계적으로 판단하고 비상상황 가상 시나리오별 체계적 행동요령 및 대처계획을 수립하여 저수지 붕괴에 따른 대규모 홍수피해 예상지역 주민들의 신속한 대응으로 생명과 재산피해를 최소화하는데 목적이 있다. 현행 한국농어촌공사 및 지자체에서 수립하고 있는 30만 톤 이상 저수지에 대한 1차원 모형 기반의 EAP수립은 침수구역을 산정할 때 수치지도에 의한 단일 침수심 분석으로 실제 침수구역과는 많은 오류가 나타난다. 이는 침수구역 부정확에 따른 피해복구액 산정이 과다로 책정될 수 있고, 마지막으로 가장 중요한 비상대처계획 수립에 막대한 영향을 미친다. 이에 본 연구는 댐 붕괴에 대응하기 위한 EAP 수립 시 기본이 되는 홍수범람해석을 수행하고 1차원 및 2차원 모형의 결과검토를 통해 보다 효과적인 비상대처계획의 수립을 위한 방안을 제시하고자 하였다. 이를 위해 경천저수지 유역을 대상으로 가능최대강수량 조건 하에서 가능최대홍수량을 산정하고 DAMBRK 모형을 이용하여 댐 붕괴 모의를 위한 시나리오 구성 및 모의를 수행하였다. 이후 댐 붕괴 모의결과를 이용하여 WMS(Watershed Modeling System) 모형을 이용한 1차원 홍수범람해석과 FLUMEN(FLUvial Modeling ENgine) 모형을 이용한 2차원 홍수범람해석에 적용 후 각 결과를 비교·검토하였다.

  • PDF

Construction of hydraulic flood prediction model for Hyeongsan river (형산강 수리학적 홍수예측 모형 구축)

  • Lee, Jae Yeong;Kim, Ji Sung;Kim, Tae Hyung;Choi, Kyu Hyun;Kim, Chang Sung
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2020.06a
    • /
    • pp.393-393
    • /
    • 2020
  • 최근 기후변화 등의 영향으로 2019년 우리나라에 영향을 준 가을 태풍은 링링, 타파, 미탁 등 3개로 근대 기상관측이 시작된 이래 가장 많은 가을 태풍이 한반도에 상륙했다. 특히, 경주시는 태풍 미탁으로 인해 97억원의 재산피해와 수해복구에 225억원이 소요될 것으로 예상되어 특별재난지역으로 선포되었다. 이러한 홍수로 인한 피해를 줄이기 위해 환경부에서는 한강, 낙동강, 금강, 영산강 홍수통제소를 설립하여 강우 및 수위관측소를 이용한 홍수에 대한 지속적인 모니터링과 홍수특보 발령 등을 수행하고 있다. 본 연구에서는 하천 홍수에 의한 침수피해를 방지하고자 수리학적 홍수예측 모형을 구축하고 이를 홍수예보에 활용할 수 있도록 하였다. 대상지역인 경주시 형산강 유역에는 현재 14개의 강우관측소와 9개의 수위관측소가 운영되고 있으며, 홍수특보 대상 지점으로 경주시(강동대교)와 포항시(형산교) 2개 지점이 있다. 형산강 유역은 현재 수문학적 홍수예측 모형을 운영하고 있으나 수위관측소 기준으로만 예측이 가능하여 정확한 예보를 위해서는 수리학적 홍수예측 모형을 구축이 필요하다. 수리학적 홍수예측 모형의 구축을 위해서는 현 상황의 하천단면, 횡단구조물 및 변화된 유역환경을 반영할 수 있는 모형의 구축이 필요하기 때문에 2013년에 수립된 형산강 하천기본계획을 참고하였으며, 모형은 홍수통제소에서 운영중인 1차원 수리해석 모형인 FLDWAV를 이용하였다. 또한, 2019년 태풍 미탁 사상을 대상으로 검보정을 실시하기 위해 상류단 경계조건으로는 경주시(서천교) 수위관측소의 유량, 하류단 경계조건으로는 포항항 조위관측소의 조위를 이용하였고 7개의 유역 유출량을 측방유입으로 구성하였다. 본 연구에서 구축된 수리학적 홍수예측 모형을 통해 기존 형산강 유역에 대한 홍수 예보 업무를 보완하여 효과적인 방재대책 마련이 가능할 것이다.

  • PDF

Logistic regression analysis for Critical Rainfall Estimation (한계강우량 산정을 위한 로지스틱 회귀분석)

  • Lee, Changhyun;Lee, Kangwon;Keum, Hojun;Kim, Byunghyun
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2022.05a
    • /
    • pp.232-232
    • /
    • 2022
  • 1차원 관망해석모형과 2차원 지표면범람 해석모형을 이용한 도시지역의 실시간 홍수예·경보시스템 구축은 모형의 모의에 많은 시간이 소요되므로 한계가 있다. 또한, 연구유역에서 시나리오 강우에 대해 침수를 유발시키는 한계강우량을 1-2차원 모형의 시행착오법을 적용한 반복적인 수행을 통해 산정하는 것은 비효율적인 방법이다. 따라서, 본 연구에서는 이에 대한 해결책으로 로지스틱 회귀를 이용하여 배수분구별 침수 발생기준 강우량을 산정하고자 한다. 침수 발생 한계강우량 산정을 배수분구 단위로 제시하기 위하여 로지스틱 회귀분석을 이용하였다. 풍수해저감종합계획(2015)과 침수흔적도를 이용하여 배수분구 별 침수이력에 대한 데이터베이스를 구축하고, 이를 1-2차원 수리해석을 통한 침수심과 함께 로지스틱 회귀모형에 학습하였다. 지속시간 1시간, 10mm 강우부터 500년 빈도의 Huff 3분위 시나리오 17개를 사용하여 확률강우량을 산정하였고, 이를 1-2차원 수리해석을 위한 입력자료로 사용하였다. EPA-SWMM을 통한 1차원 도시유출해석과 FLO-2D를 통한 2차원 침수해석에서 20cm 이상의 침수심이 발생하거나 지상관측자료, 침수흔적도 및 풍수해저감종합계획에서 실제 침수가 발생했을 경우를 1, 그렇지 않은 경우를 0으로 하여 데이터베이스를 구축하여 로지스틱 회귀모형에 학습시켜 침수 발생 한계강우량을 산정하였다. 로지스틱 회귀분석을 통해 서울시 지역의 배수분구별 한계강우량을 산정할 수 있으며, 지속적으로 관측되는 강우 및 침수 발생 유무 자료를 추가함으로써 산정된 침수 한계강우량을 상회하는 강우 사상이 나타났을 시에 침수 발생 유무를 확인하여 본 연구에서 제안한 방법에 대해 검증이 가능할 것으로 보인다.

  • PDF

Comparison of Response Systems and Education Courses against HNS Spill Incidents between Land and Sea in Korea (국내 HNS 사고 대응체계 및 교육과정에 관한 육상과 해상의 비교)

  • Kim, Kwang-Soo;Gang, Jin Hee;Lee, Moonjin
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.21 no.6
    • /
    • pp.662-671
    • /
    • 2015
  • As the type of Hazardous and Noxious Substances(HNS) becomes various and the transport volume of HNS increases, HNS spill incidents occur frequently on land and the sea. In view of various damages to human lives and properties by HNS spills, it is necessary to educate and train professional personnel in preparation for and response to potential HNS spills. This study shows the current state of response systems and education courses against HNS spill incidents on land and the sea to compare those with each other between land and sea in Korea. Incident command system on land are basically similar to that at sea, but leading authority which is responsible for combating HNS spills at sea is changeable depending on the location of HNS spill, as it were, Korea Coast Guard(KCG) is responsible for urgent response to HNS spill at sea, while municipalities are responsible for the response to HNS drifted ashore. Education courses for HNS responders on land are established at National Fire Service Academy(NFSA), National Institute of Chemical Safety(NICS), etc., and are diverse. Education and training courses for HNS responder at sea are established at Korea Coast Guard Academy(KCGA) and Marine Environment Research & Training Institute(MERTI), and are comparatively simple. Education courses for dangerous cargo handlers who work in port where land is linked to the sea are established at Korea Maritime Dangerous Goods Inspection & Research Institute(KOMDI), Korea Port Training Institute(KPTI) and Korea Institute of Maritime and Fisheries Technology(KIMFT). Through the comparison of education courses for HNS responders between land and sea, some recommendations such as extension of education targets, division of an existing integrated HNS course into two courses composed of operational level and manager level with respective refresh course, on-line cyber course and joint inter-educational institute course in cooperation with other relevant institutes are proposed for the improvement in education courses of KCG and KOEM(Korea Marine Environment Management Corporation) to educate and train professionals for combating HNS spills at sea in Korea.

The study of heavy rain warning in Gangwon State using threshold rainfall (침수유발 강우량을 이용한 강원특별자치도 호우특보 기준에 관한 연구)

  • Lee, Hyeonjia;Kang, Donghob;Lee, Iksangc;Kim, Byungsikd
    • Journal of Korea Water Resources Association
    • /
    • v.56 no.11
    • /
    • pp.751-764
    • /
    • 2023
  • Gangwon State is centered on the Taebaek Mountains with very different climate characteristics depending on the region, and localized heavy rainfall is a frequent occurrence. Heavy rain disasters have a short duration and high spatial and temporal variability, causing many casualties and property damage. In the last 10 years (2012~2021), the number of heavy rain disasters in Gangwon State was 28, with an average cost of 45.6 billion won. To reduce heavy rain disasters, it is necessary to establish a disaster management plan at the local level. In particular, the current criteria for heavy rain warnings are uniform and do not consider local characteristics. Therefore, this study aims to propose a heavy rainfall warning criteria that considers the threshold rainfall for the advisory areas located in Gangwon State. As a result of analyzing the representative value of threshold rainfall by advisory area, the Mean value was similar to the criteria for issuing a heavy rain warning, and it was selected as the criteria for a heavy rain warning in this study. The rainfall events of Typhoon Mitag in 2019, Typhoons Maysak and Haishen in 2020, and Typhoon Khanun in 2023 were applied as rainfall events to review the criteria for heavy rainfall warnings, as a result of Hit Rate accuracy verification, this study reflects the actual warning well with 72% in Gangneung Plain and 98% in Wonju. The criteria for heavy rain warnings in this study are the same as the crisis warning stages (Attention, Caution, Alert, and Danger), which are considered to be possible for preemptive rain disaster response. The results of this study are expected to complement the uniform decision-making system for responding to heavy rain disasters in the future and can be used as a basis for heavy rain warnings that consider disaster risk by region.

Development of remote control automatic fire extinguishing system for fire suppression in double-deck tunnel (복층터널 화재대응을 위한 원격 자동소화 시스템 개발 연구)

  • Park, Jinouk;Yoo, Yongho;Kim, Yangkyun;Park, Byoungjik;Kim, Whiseong;Park, Sangheon
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.21 no.1
    • /
    • pp.167-175
    • /
    • 2019
  • To effectively deal with the fire in tunnel which is mostly the vehicle fire, it's more important to suppress the fire at early stage. In urban tunnel, however, accessibility to the scene of fire by the fire fighter is very limited due to severe traffic congestion which causes the difficulty with firefighting activity in timely manner and such a problem would be further worsened in underground road (double-deck tunnel) which has been increasingly extended and deepened. In preparation for the disaster in Korea, the range of life safety facilities for installation is defined based on category of the extension and fire protection referring to risk hazard index which is determined depending on tunnel length and conditions, and particularly to directly deal with the tunnel fire, fire extinguisher, indoor hydrant and sprinkler are designated as the mandatory facilities depending on category. But such fire extinguishing installations are found inappropriate functionally and technically and thus the measure to improve the system needs to be taken. Particularly in a double-deck tunnel which accommodates the traffic in both directions within a single tunnel of which section is divided by intermediate slab, the facility or the system which functions more rapidly and effectively is more than important. This study, thus, is intended to supplement the problems with existing tunnel life safety system (fire extinguishing) and develop the remote-controlled automatic fire extinguishing system which is optimized for a double-deck tunnel. Consequently, the system considering low floor height and extended length as well as indoor hydrant for a wide range of use have been developed together with the performance verification and the process for commercialization before applying to the tunnel is underway now.

A Study on Flame Retardant Performance of Vertical Blind and Roll Screen (버티칼 브라인드와 롤 스크린의 방염성능 유지에 관한 연구)

  • Jeong, Hyun Gyu;Cho, Woncheol;Lee, Tae Sik
    • Journal of Korean Society of societal Security
    • /
    • v.3 no.2
    • /
    • pp.41-46
    • /
    • 2010
  • This study focuses on two points. First, I have examined the difference on combustion between flame-retardant and non flame-retardant products including vertical blinds and roll screens that are widely used as a substitute for fabric curtains. The second point is to see how long flame-retardant goods can be durable, that is, flame retardant durability after washing in liquid. the experiment on the flame-retardant ability before and after washing of vertical blinds and roll screens that have been used for a long time in fire protection construct. Comparing and analyzing domestic and foreign laws on flame-retardant after the experiment on durability of these products. I aim to draw necessity for increased application of internal laws and regulations on flame-retardant and show how to improve the point at issue. According to the result, clear differences in performance and safety were observed between flame-retardant and non flame-retardant products. flame-retardant materials can prevent things from fire spread without igniting but melting when they've met flame and burnt, In contrast, non flame-retardant material for experiment which size is 120cm long takes less than 3 minutes only to be completely destroyed by fire. However, it was expected for flame-retardant durability of flame-retardant blinds which are not washable to decrease flame-retardant durability after being washed with water, there was no sharp difference. so it is demonstrated that flame-retardant blinds can keep flame-retardant durability. accordingly through the strict course of product we are concerned about keeping durability.

  • PDF

A Study on the Behavior of an Existing Tunnel and the Safety Implications on its Facilities from a New Tunnel Blasting (신설 터널 발파 시 기존 터널 거동 및 시설물 안전에 관한 연구)

  • Kim, Sung Hoon;Cho, Woncheol
    • Journal of Korean Society of societal Security
    • /
    • v.3 no.2
    • /
    • pp.57-64
    • /
    • 2010
  • In this study, the behavior and safety of an existing tunnel and its facilities are investigated when a new tunnel adjacent to the existing tunnel is blasted. The design of the new tunnel puts priority on stability of the tunnel itself over the safety of the facilities which are installed within the existing tunnel such as jet fans. And thus, a detailed consideration on securing the safety of the existing facilities has been insufficient. An analysis on the types of traffic accidents in the last ten years shows that most incidents were due to the driver's improper response in emergency situations and unexpected obstacles. In consideration of this analysis, the safety of the facilities in the existing tunnel was secured by minimizing the charging amount for each hangfire and changing the excavation method of evacuation communication shelters to the large center hole cut blasting method to reduce blasting vibration. For a more quantitative analysis, measurement devices were installed inside the existing tunnel, at houses adjacent to the new tunnel, near jet fans in the existing tunnel. This enabled real time measurement of displacements of the existing tunnel, adjacent houses, and jet fans without interrupting traffic flow. Therefore, the improvements of charging amount for each hangfire, the blasting method, and the measurement method are suggested in this paper to secure the safety of the facilities in the existing tunnel when a new tunnel, located on a large city and adjacent to an existing tunnel, is designed.

  • PDF

The Effects of Transformational Leadership on Organizational Culture and Innovation in the Fire Fighting Organization (소방조직의 변혁적 리더십이 조직문화와 혁신에 미치는 영향)

  • Park, Chang-Soon;Choi, Kyu-Chool
    • Fire Science and Engineering
    • /
    • v.27 no.6
    • /
    • pp.104-114
    • /
    • 2013
  • This study is intended to figure out the effects of supervisors' transformational leadership on organizational culture and innovation in the fire fighting organization. To achieve this, a survey was carried out to fire officers from the National Emergency Management Agency and Seoul Metropolitan Fire & Disaster Headquarters. The results are as follows. First, the effect of supervisors' transformational leadership on organizational culture showed that supervisors' transformational leadership had an effect on group culture, norm culture and rational culture by sub-factors of organizational culture in the fire fighting organization. Second, the effect of organizational culture on organizational innovation showed that group culture and rational culture had an effect on organizational innovation. Third, the effect of supervisors' transformational leadership on organizational innovation showed that supervisors' transformational leadership had an effect on organizational innovation. As for findings stated above, supervisors' transformational leadership had positive effects on organizational culture and innovation in the fire fighting organization. Consequently, supervisors' energetic and change-seeking leader-ship for junior staffs with existing organization-and new generation-oriented new thinking system can contribute to rational culture and development-oriented innovation based on norms in the group.