• Title/Summary/Keyword: 장치위치

Search Result 2,748, Processing Time 0.037 seconds

Verification of GPS/INS for the SmartUAV using Aircraft Flight Test and Automobile Road Test (스마트무인기 위성관성항법장치의 비행시험 및 차량시험을 통한 검증)

  • Chang, Sung-Ho;Yoo, Jang-Sik;Gwak, Min-Gyu;Hong, Jin-Seok
    • Aerospace Engineering and Technology
    • /
    • v.10 no.2
    • /
    • pp.1-10
    • /
    • 2011
  • This is a comparative study of three inertia navigation units and focuses on the verification of reliability about GPS/INS for the SmartUAV(DGNS). Those GPS/INS have been tested using a manned aircraft and an automobile. The comparative aspect of units include details about the GPS positions and the inertia sensor performance. With the flight scenario, the DGNS guarantees the reliability of the navigation operation and performs the flight test for the development of the SmartUAV.

Actuator and load test system development for continuous variable thruster (연속가변 추력기용 구동장치 및 부하시험장비 개발)

  • Kim, Namjin;Kim, Hyoungkwon;Park, Hyunho;Lim, Jinwan;Suh, Suhkhoon;Park, Iksoo
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2017.05a
    • /
    • pp.401-405
    • /
    • 2017
  • Continuous variable thrusters require precise thrust control to change the position or attitude of the aircraft and to control the pressure inside the combustion chamber. For this purpose, the thrust is adjusted by moving the pintle structure near the nozzle neck inside the combustion chamber by moving the pintle structure forward and backward, and the actuator is used to move the pintle structure. In this paper, we developed a actuator system for continuous variable thruster and load test system to simulate the load under operating conditions. Also, the performance test of the actuator was performed using the developed load test system

  • PDF

Analysis of Cooling Characteristics according to Heating Reduction System Displacement of Major Heating Region on Power Inverter (전력 역변환장치 주요발열부의 열 저감 시스템 변위에 따른 냉각 특성해석)

  • Kim, Min-Seok;Kim, Yong-Jae
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.10 no.2
    • /
    • pp.261-266
    • /
    • 2015
  • Power system for renewable energy is composed of module, transform DC power into AC power inverter, control power flow and device for a charge of the grid-connected. Power system for renewable energy produce the most DC power, when this system is much insolation in summer and daytime. But if the certain temperature rises above, the essential grid-connected power inverter is take a nose dive. There, in this paper, we propose an improved reduction of heating system. In addition, selection of the most serious heat region and through analysis of temperature characteristics according to location and distance derive the optimal model.

Experimental investigation of intrusive gravity current in stratified fluid (성층화된 유체 내에서 침입중력류의 실험적 연구)

  • Paik, Joong-Cheol;Son, Shin-Hye
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2012.05a
    • /
    • pp.173-173
    • /
    • 2012
  • 중력류는 두 유체 사이에서 물질의 종류 또는 온도차로 인한 밀도 차이에 의해 발생되는 유체의 흐름을 말하며, 자연환경에서는 저수지에서의 중층탁류, 사막에서의 모래 폭풍, 하구에서의 염수쐐기 등이 그 예이다. 여름철에 강우가 집중되는 우리나라는 홍수에 의한 범람, 침수 등이 발생할 뿐만 아니라 댐이나 하천, 호수 등에 흙탕물이 유입되어 중간층에 정체하는 중층탁류에 의한 피해가 자주 발생하고 있다. 과거에 중층탁류는 일시적인 현상에 불과하였으나 오늘날에는 인공적으로 형성된 정체성 호수나 하천에서 장기간 체류하여 생태계의 교란과 수질 악화를 초래하고 있다. 중층탁류에 의한 피해를 저감시키기 위해서는 본래 자연 상태의 하천이나 호수와 같이 온도분포가 비선형적으로 성층화 된 상태에서 탁수가 유입되어 중층탁류가 형성되는 과정과 흐름 특성을 이해하는 것이 선행되어야 한다. 본 연구에서는 중력류 흐름 해석을 위한 실험 장치를 개발하였다. 실험 장치 중 수조의 제원은 1200 $700{\times}300mm$이며, 수조 상부에는 가열장치를 설치하였고, 수조 하부에는 냉각장치를 설치하였다. 이들 장치들을 가동하여 깊이에 따른 자연현상에서의 비선형적인 온도 단면을 재현한다. 수리 실험방법은 깊이 방향으로 온도에 따라 비선형적으로 성층화 된 유체 내로 경사가 있는 판을 따라 수조내의 성층화된 유체의 중간 온도 혹은 밀도를 가진 유체를 침입시킨다. 침입유체는 성층화된 유체 내에서 초기에는 중력에 의해 운동량을 갖고 경사면을 따라 일정한 속도로 흘러내려 간다. 이후 바닥으로 하강 한 후 부력에 의해 상승하여 동일한 밀도층의 위치에서 횡방향으로 전파하게 된다. 이 연구에서는 이와 같이 비선형적으로 성층화된 유체 내에서의 침입 중력류의 흐름 특성을 실험적으로 관측하고 분석한다.

  • PDF

TV용 전원장치 기술

  • Han, Sang-Gyu
    • KIPE Magazine
    • /
    • v.27 no.3
    • /
    • pp.31-37
    • /
    • 2022
  • 20세기 디스플레이의 중심에 서 있던 브라운관이 1990년대 이후 PDP나 LCD 등 박형 평판디스플레이로 대체되면서 현재까지 스크린 사이즈의 중대형화, 고해상도화, 저소비전력화, 저가격화 등 다양한 노력들이 지속적으로 이루어져 왔다. 특히 TV와 디스플레이 산업에 있어 우리나라는 2004년 이후 세계 점유율 1위의 위치를 꾸준히 유지해 오고 있으나 2020년에 들어서면서 중국과의 격차가 1%대로 좁혀지고 있는 등 TV 시장에 대한 후발주자의 공세가 점차 거세지고 있다. 이에 따라 LCD에서 OLED나 마이크로 LED 등 차세대 디스플레이로의 사업구조 전환을 서두르고 있으며 후발주자의 추격 또한 만만치 않은 상황에 있다. 이러한 가운데 코로나 19를 계기로 비대면 문화가 확산되면서 IT 제품 수요가 지속적인 강세를 보이고 있으며 TV와 디스플레이도 대형 및 프리미엄 TV를 중심으로 그 수요가 빠르게 확대 개선되고 있는 추세로서 100인치대 내외의 대화면, 8K UHD와 같은 초고해상도, 5-10mm 수준의 초슬림에 대한 요구가 절정을 이루고 있다. 이를 위해 TV와 디스플레이를 구성하는 핵심 요소인 전원장치 또한 고전력밀도와 초솔림화를 위한 많은 연구 개발이 이루어지고 있으며 특히 최근 EU의 에코디자인 규정에 따라 디스플레이의 소비전력과 효율 또한 매우 중요한 이슈로 부각되고 있다. 한편, 최근까지 주류를 이루고 있는 LCD TV와 디스플레이용 전원장치의 경우 역률 개선을 위한 PFC(Power Factor Correction) 단과 LED 백라이트 및 영상보드의 전원공급을 위한 절연형 DC/DC 단으로 구성되며, OLED와 같은 저전압 대전류 디스플레이 소자의 경우 전반적인 전원장치의 구성은 유사하나 비절연형 DC/DC컨버터가 추가적으로 요구되기도 한다. 본고에서는 상기한 바와 같은 최근 추세에 따라 TV 및 디스플레이용 전원장치의 각 구성요소별로 고효율, 고밀도, 초슬림을 위한 전원회로 기술에 대해 간략히 소개한다.

Patient Position Verification and Corrective Evaluation Using Cone Beam Computed Tomography (CBCT) in Intensity.modulated Radiation Therapy (세기조절방사선치료 시 콘빔CT (CBCT)를 이용한 환자자세 검증 및 보정평가)

  • Do, Gyeong-Min;Jeong, Deok-Yang;Kim, Young-Bum
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.21 no.2
    • /
    • pp.83-88
    • /
    • 2009
  • Purpose: Cone beam computed tomography (CBCT) using an on board imager (OBI) can check the movement and setup error in patient position and target volume by comparing with the image of computer simulation treatment in real.time during patient treatment. Thus, this study purposed to check the change and movement of patient position and target volume using CBCT in IMRT and calculate difference from the treatment plan, and then to correct the position using an automated match system and to test the accuracy of position correction using an electronic portal imaging device (EPID) and examine the usefulness of CBCT in IMRT and the accuracy of the automatic match system. Materials and Methods: The subjects of this study were 3 head and neck patients and 1 pelvis patient sampled from IMRT patients treated in our hospital. In order to investigate the movement of treatment position and resultant displacement of irradiated volume, we took CBCT using OBI mounted on the linear accelerator. Before each IMRT treatment, we took CBCT and checked difference from the treatment plan by coordinate by comparing it with the image of CT simulation. Then, we made correction through the automatic match system of 3D/3D match to match the treatment plan, and verified and evaluated using electronic portal imaging device. Results: When CBCT was compared with the image of CT simulation before treatment, the average difference by coordinate in the head and neck was 0.99 mm vertically, 1.14 mm longitudinally, 4.91 mm laterally, and 1.07o in the rotational direction, showing somewhat insignificant differences by part. In testing after correction, when the image from the electronic portal imaging device was compared with DRR image, it was found that correction had been made accurately with error less than 0.5 mm. Conclusion: By comparing a CBCT image before treatment with a 3D image reconstructed into a volume instead of a 2D image for the patient's setup error and change in the position of the organs and the target, we could measure and correct the change of position and target volume and treat more accurately, and could calculate and compare the errors. The results of this study show that CBCT was useful to deliver accurate treatment according to the treatment plan and to increase the reproducibility of repeated treatment, and satisfactory results were obtained. Accuracy enhanced through CBCT is highly required in IMRT, in which the shape of the target volume is complex and the change of dose distribution is radical. In addition, further research is required on the criteria for match focus by treatment site and treatment purpose.

  • PDF

A study of mandibular positional changes by the stabilization splint in TMD patients (측두하악장애환자에서 교합안정장치가 하악골위치변화에 미치는 영향에 관한 연구)

  • Cheon, Hun;Park, Young-Guk;Chung, Kyu-Rhim
    • The korean journal of orthodontics
    • /
    • v.30 no.4 s.81
    • /
    • pp.491-507
    • /
    • 2000
  • The purpose of this study was to investigate if there were a significant differences in mandibular position between cephalometric measurements from a centric occlusion tracing compared to those of a acquired centric relation by stabilization splint on malocclusion patient with TMD. 60 malocclusion patients, who had TMD and CO-CR discrepancy beyond normal range, were selected and subdivided into Class I, II, III by Angle's classification and also subdivided into clockwise, straight downward, and counterclockwise group by Jarabak's posterior facial height/anterior facial height ratio. Lateral cephaolmetric radiographs with the mandible in centric occlusion were taken and measured, and for each Patient the stabilization splint with mutually protected occlusal scheme was applied for minimum 3months. After each patient's CO-CR discrepancy was in normal range, lateral cephalometric radiographs were retaken and measured. The comparison of the difference between CO-CR cephalometric measurements in all sample, Class I, II, III groups, and Clockwise, Straight downward, Counterclockwise groups were studied. The finding of this study can be summarized as follows: 1 In all sample, the value of cephalometric measurements was significantly different between CO-CR. The mandible rotated to down and posterior position and the vertical change was greater than the horizontal change (overjet-1.3mm increase, overbite-1.9mm decrease). 2. In Class II malocclusion group, most of the mean difference value between CO-CR is higher than that of the other groups and more measurements was statically significant. 3. In clockwise and counterclockwise group, some of the mean difference value is higher than that of straight downward group and more measurements was statically significant. 4. There ware no measurements that explain centric relation measurements from the type of malocclusion, facial pattern and centric occlusion measurements. Henceforth, it is strongly recommended that stabilization splint therapy for orthodontic treatment on TMD patient should be excuted upon overall facial types prior to orthodontic diagnosis and treatment planning.

  • PDF

Development of nuclear measurement system for gamma column scanning (증류탑 진단을 위한 방사선 응용계측기 개발)

  • Kim, Jong-Bum;Jung, Sung-Hee;Jin, Jun-Ha;Jun, Jong-Kuj
    • Proceedings of the KIEE Conference
    • /
    • 2004.07d
    • /
    • pp.2619-2621
    • /
    • 2004
  • 감마선 또는 x-선 등 방사선을 이용한 구조물 진단은 산업전반에 걸쳐 널리 이용되고 있다. 기존의 x-선이나 Ir-192의 감마선 등을 이용한 비파괴검사는 용접부의 확인이나 구조물의 내부 결점 확인과 같이 국부적인 진단에는 유용하나 석유화학산업에서 반응물의 분리 또는 정제 등에 많이 사용되고 있는 증류탑의 내부진단 실험에는 적합하지 않다. 증류탑은 목적에 따라 직경이 $3{\sim}10m$, 높이 $10{\sim}100m$에 달하는 대형 장치로서 내부의 이상현상에 대한 정확한 진단은 공정 전체의 가동효율 최적화에 결정적인 영향을 끼친다. 밀봉 감마선원으로부터 방출된 방사선의 투과율 변화를 증류탑의 반대편에 설치한 방사선 검출기로 측정하여 수직밀도분포(vertical density profile)를 구하여 증류탑의 내부현상에 대한 정확한 정보를 얻을 수 있는데 이러한 작업을 자동으로 수행할 수 있도록 한 것이 자동 증류탑 검사장치이다. 증류탑 진단장치는 크게 방사선 계측 및 데이터 전송회로, 방사선원부와 방사선검출부의 구동장치 및 구동회로, 데이터 수집 및 제어장치 둥으로 구성되어 있으며, 증류탑 검사를 자동화하여 진단결과의 신뢰도와 재현성을 향상시켰다. 본 논문은 방사선원과 방사선 검출장치의 위치를 자동으로 제어하면서 방사선 계측결과를 전송시키는 장치의 개발에 관한 내용으로서 개발된 장치의 소개와 산업현장 적용의 예를 소개함으로써 기존의 비파괴검사기술로는 진단할 수 없는 대형 증류탑의 진단에 효과적인 방사선 응용 계측장치임을 보이고자 한다.

  • PDF

A Study on Automatic Sensing Device for Water Leakage of Cooling Pipe at Blast Furnace by Use The Electronic System (전자제어 장치를 이용한 용광로 냉각관 누수 지동 감지장치 개발에 관한 연구)

  • Kang, Chang-Soo;Kang, Ki-Seong
    • 전자공학회논문지 IE
    • /
    • v.46 no.4
    • /
    • pp.25-30
    • /
    • 2009
  • The cooling water circulation pipes had been used to drop the temperature of refractory outside shell of blast furnace by cooling plate or stave type. They were attacked by surrounding CO gas and it was the cause that they were corroded and the water inflow in the refractory due to leakage of water. So, the life of refractory material was shorten and changed for the worse the conditions of blast furnace. The automatic sensing device for water leakage of cooling pipe was developed to check the position of trouble by use the micro-process system when cooling water leak and then CO gas will be inflowed into the cooling pipe at the leakage position. The inflowed CO gas will be detected in the micro-process system and delivered the detected position of cooling plate or stave to main control room through the wireless-radio relay station. This system can be possible to detect the position of cooling plate or stave the water leakage part immediately and then deliver the signal to main control room by use the micro-process system and wireless-radio relay station. This system will develop the working condition from manual system to unmanned auto alarm system.

A Study on QA for Radiation Therapy Machine by Using Implemented Electronic Portal Imaging Device (전자포탈영상장치의 제작과 방사선치료장치의 QA 적용에 관한 연구)

  • Lee, Dong-Hoon
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.43 no.6 s.312
    • /
    • pp.68-75
    • /
    • 2006
  • During cancer therapy by using high energy radiation, it is possible to improve the radiation therapy efficiency by performing a precise radiation therapy after verification of generated setup errors. In this paper, the video based electronic portal imaging device (EPID) which could display the portal image with near real time was developed to verify treatment position errors in radiation therapy instead of an analog typed portal film. This EPID system for applying QA tool of radiation therapy machine was consisted of a metal/fluorescent screen, $45^{\circ}$mirror, camera and image grabber. Radiation field verification has been performed to check quality assurance of the treatment machine itself by using this EPID system. The radiation field error was easily observed by edge detection of irradiated field size on EPID image when $0.6^{\circ}$ shift of collimator angle was generated. So, this implemented EPID system could be used as a radiation QA tool.