• Title/Summary/Keyword: 장착 오차

Search Result 278, Processing Time 0.027 seconds

Performance Evaluation of Automatic Exercise Weight and Repetition Measuring Device Add-on for Existing Fitness Machines (기존 운동기기 부착용 운동중량/횟수 자동측정기기의 성능평가)

  • Kim, Jung Gi;Lee, Yongkoo
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.41 no.4
    • /
    • pp.329-332
    • /
    • 2017
  • In this study, a performance evaluation was carried out to develop a new add-on device with an algorithm for automatically measuring the exercise weight and repetitions when using an existing fitness machine. The developed device was designed to be simply attached to an exercise machine to measure the exercise weight and repetitions. The measured data are transferred to a smartphone using Bluetooth. As result, it is possible to detect the weights and repetitions from three users with different exercise habits with little error. The system can measure the user's motion and transfer the data to various devices capable of utilizing the workout data, giving it the advantage of being applicable to personalized health care and rehabilitation therapy.

Seismic Control of Tuned Mass Damper System with MDOF Sliding Mode Control Accounting for the Uncertainties (불확실성을 고려한 동조질량 감쇠기(TMD) 시스템의 다자유도 슬라이딩 모드 지진동 제어)

  • Lee, Jin Ho
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.15 no.1
    • /
    • pp.235-242
    • /
    • 2011
  • The control performance in active structural control system can be drastically deteriorated when the modeling errors and the uncertainties existing in the disturbances are disregarded in the designing stage. It can even throw the control system into an unstable phase, resulting in out of control against the seismic excitations. The purpose of the study is to investigate the control effectiveness of a non-linear control system called sliding mode controller(SMC) in cooperation with a Tuned Mass Damper subjected to the three seismic excitations selected from the FFT analysis. Even though the transient performance such as settling time and overshoot were deteriorated, the robustness against the system stability was appeared from SMC when the structural masses and stiffness perturbed within the range of ${\pm}30%$. SMC is a feasible technique for active structural control in cooperation with TMD against seismic disturbances, exhibiting robustness in perturbation of system stiffness and mass as well as uncertainties of the disturbances.

3D Positioning Using a UAV Equipped with a Stereo Camera (스테레오 카메라를 탑재한 UAV를 이용한 3차원 위치결정)

  • Park, Sung-Geun;Kim, Eui-Myoung
    • Journal of Cadastre & Land InformatiX
    • /
    • v.51 no.2
    • /
    • pp.185-198
    • /
    • 2021
  • Researches using UAVs are being actively conducted in the field of quickly constructing 3D spatial information in small areas. In this study, without using ground control points, a stereo camera was mounted on a UAV to collect images and quickly construct three-dimensional positions through image matching, bundle adjustment, and the determination of a scale factor. Through the experiment, when bundle adjustment was performed using stereo constraints, the root mean square error was 1.475m, and when absolute orientation was performed in consideration of a scale, it was found to be 0.029m. Through this, it was found that when using the data processing method of a UAV equipped with a stereo camera proposed in this study, high-accuracy 3D spatial information can be constructed without using ground control points.

Implementation of In-Car GNSS Jamming Signal Data Generator to Test Autonomous Driving Vehicles under RFI Attack on Navigation System (항법 시스템 오작동 시 자율주행 알고리즘 성능 테스트를 위한 차량 내 재밍 신호 데이터 발생기 구현)

  • Kang, Min Su;Jin, Gwon Gyu;Won, Jong Hoon
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.20 no.2
    • /
    • pp.79-94
    • /
    • 2021
  • A GNSS receiver installed in autonomous vehicles is the most essential device for its navigation. However, if an intentional jamming signal is generated, there is a risk of exposure to an accident risk due to deterioration of the GNSS sensor's performance. Research is required to prevent this, and accordingly, a jamming generating device must be provided. However, according to the provisions of the law related to jamming, this is illegal. In this paper, we implement an in-vehicle jamming device that complies with the provisions of the law and does not affect the surrounding GNSS sensors. Driving simulation is used to evaluate the performance of the GNSS algorithm, and the malfunction of autonomous vehicles occurring in the interference environment and data errors output from the GNSS sensor are analyzed.

W-Band Radar Altimeter for Drones (드론용 W-대역 레이다 고도계)

  • Lee, Yong-Seok;Lee, Gwon-Hak;Kim, Jun-Seong;Park, Jae-Hyun;Kim, Byung-Sung;Song, Reem
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.30 no.4
    • /
    • pp.314-319
    • /
    • 2019
  • In this study, we propose a W-band frequency modulated continuous wave(FMCW) radar altimeter that can measure the altitude based on the frequency differences of transmitted and received signals. This W-band FMCW system is powered by an altitude control algorithm, which we propose to help prevent collisions of drones with obstacles in real deployment by measuring the relative altitude. It is shown that this algorithm enables the drone to be positioned within a 3 % error of altitude from the desired input height. The chip used in the W-band transmitter and receiver was fabricated using a 65-nm CMOS process, and a horn antenna was directly fed by incorporating an embedded waveguide feeder into the chip. The clutter spectra observed in terrains including soil, grass, and calm lake water were measured and compared, confirming the reflectivity characteristics of various surfaces of different water contents.

Vision-based Food Shape Recognition and Its Positioning for Automated Production of Custom Cakes (주문형 케이크 제작 자동화를 위한 영상 기반 식품 모양 인식 및 측위)

  • Oh, Jang-Sub;Lee, Jaesung
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.24 no.10
    • /
    • pp.1280-1287
    • /
    • 2020
  • This paper proposes a vision-based food recognition method for automated production of custom cakes. A small camera module mounted on a food art printer recognizes objects' shape and estimates their center points through image processing. Through the perspective transformation, the top-view image is obtained from the original image taken at an oblique position. The line and circular hough transformations are applied to recognize square and circular shapes respectively. In addition, the center of gravity of each figure are accurately detected in units of pixels. The test results show that the shape recognition rate is more than 98.75% under 180 ~ 250 lux of light and the positioning error rate is less than 0.87% under 50 ~ 120 lux. These values sufficiently meet the needs of the corresponding market. In addition, the processing delay is also less than 0.5 seconds per frame, so the proposed algorithm is suitable for commercial purpose.

Improvement of Electroforming Process System Based on Double Hidden Layer Network (이중 비밀 다층구조 네트워크에 기반한 전기주조 공정 시스템의 개선)

  • Byung-Won Min
    • Journal of Internet of Things and Convergence
    • /
    • v.9 no.3
    • /
    • pp.61-67
    • /
    • 2023
  • In order to optimize the pulse electroforming copper process, a double hidden layer BP (Back Propagation) neural network is constructed. Through sample training, the mapping relationship between electroforming copper process conditions and target properties is accurately established, and the prediction of microhardness and tensile strength of the electroforming layer in the pulse electroforming copper process is realized. The predicted results are verified by electrodeposition copper test in copper pyrophosphate solution system with pulse power supply. The results show that the microhardness and tensile strength of copper layer predicted by "3-4-3-2" structure double hidden layer neural network are very close to the experimental values, and the relative error is less than 2.32%. In the parameter range, the microhardness of copper layer is between 100.3~205.6MPa and the tensile strength is between 112~485MPa.When the microhardness and tensile strength are optimal,the corresponding process conditions are as follows: current density is 2A-dm-2, pulse frequency is 2KHz and pulse duty cycle is 10%.

Development of Video Image-Guided Setup (VIGS) System for Tomotherapy: Preliminary Study (단층치료용 비디오 영상기반 셋업 장치의 개발: 예비연구)

  • Kim, Jin Sung;Ju, Sang Gyu;Hong, Chae Seon;Jeong, Jaewon;Son, Kihong;Shin, Jung Suk;Shin, Eunheak;Ahn, Sung Hwan;Han, Youngyih;Choi, Doo Ho
    • Progress in Medical Physics
    • /
    • v.24 no.2
    • /
    • pp.85-91
    • /
    • 2013
  • At present, megavoltage computed tomography (MVCT) is the only method used to correct the position of tomotherapy patients. MVCT produces extra radiation, in addition to the radiation used for treatment, and repositioning also takes up much of the total treatment time. To address these issues, we suggest the use of a video image-guided setup (VIGS) system for correcting the position of tomotherapy patients. We developed an in-house program to correct the exact position of patients using two orthogonal images obtained from two video cameras installed at $90^{\circ}$ and fastened inside the tomotherapy gantry. The system is programmed to make automatic registration possible with the use of edge detection of the user-defined region of interest (ROI). A head-and-neck patient is then simulated using a humanoid phantom. After taking the computed tomography (CT) image, tomotherapy planning is performed. To mimic a clinical treatment course, we used an immobilization device to position the phantom on the tomotherapy couch and, using MVCT, corrected its position to match the one captured when the treatment was planned. Video images of the corrected position were used as reference images for the VIGS system. First, the position was repeatedly corrected 10 times using MVCT, and based on the saved reference video image, the patient position was then corrected 10 times using the VIGS method. Thereafter, the results of the two correction methods were compared. The results demonstrated that patient positioning using a video-imaging method ($41.7{\pm}11.2$ seconds) significantly reduces the overall time of the MVCT method ($420{\pm}6$ seconds) (p<0.05). However, there was no meaningful difference in accuracy between the two methods (x=0.11 mm, y=0.27 mm, z=0.58 mm, p>0.05). Because VIGS provides a more accurate result and reduces the required time, compared with the MVCT method, it is expected to manage the overall tomotherapy treatment process more efficiently.

Objective Analysis of the Set-up Error and Tumor Movement in Lung Cancer Patients using Electronic Portal Imaging Device (폐암 환자에서 Electronic Portal Imaging Device를 이용한 자세 오차 및 종양 이동 거리의 객관적 측정)

  • Kim, Woo-Cheol;Chung, Eun-Ji;Lee, Chang-Geol;Chu, Sung-Sil;Kim, Gwi-Eon
    • Radiation Oncology Journal
    • /
    • v.14 no.1
    • /
    • pp.69-76
    • /
    • 1996
  • Purpose : The aim of this study is to investigate the random and systematic errors and tumor movement using electronic portal imaging device in lung cancer patients for the adequate margin in the treatment planning of 3-dimensional conformal therapy. Material and Methods : The electronic portal imaging device is matrix ion chamber type(Portal Vision, Varian). Ten patients of lung cancer treated with chest irradiation were selected for this study. Patients were treated in the supine position without immobilization device. All treatments were delivered by an 10 MV linear accelerator that had the portal imaging system mounted to its ganrty. AP or PA field Portal images were only analyzed. Radiation therapy field included the tumor, mediastinum and supraclavicular lymph nodes. A total of 103 portal images were analyzed for set-up deviation and 10 multiple images were analyzed for tumor movement because of respiration and cardiac motion. Result : The average values of setup displacements in the x, y direction was 1.41 mm, 1 78 mm, respectively. The standard deviation of systematic component was 4.63 mm, 4.11 mm along the x, y axis, respectively while the random component was 4.17 mm in the x direction and 3.31 mm in the y direction. The average displacement from respiratory movement was 12.2 mm with a standard deviation of 4.03 mm. Conclusion : The overall set-up displacement includes both random and systematic component and respiratory movement. About 10 mm, 25 mm margins along x, y axis which considered the set-up displacement and tumor movement were required for initial 3-dimensional conformal treatment planning in the lung cancer patients and portal images should be made and analyzed during first week of treatment, individually.

  • PDF

Development of Adjustable Head holder Couch in H&N Cancer Radiation Therapy (두경부암 방사선 치료 시 Set-Up 조정 Head Holder 장치의 개발)

  • Shim, JaeGoo;Song, KiWon;Kim, JinMan;Park, MyoungHwan
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.1
    • /
    • pp.43-50
    • /
    • 2014
  • In case of all patients who receive radiation therapy, a treatment plan is established and all steps of treatment are planned in the same geometrical condition. In case of head and neck cancer patients who undergo simulated treatment through computed tomography (CT), patients are fixed onto a table for planning, but laid on the top of the treatment table in the radiation therapy room. This study excogitated and fabricated an adjustable holder for head and neck cancer patients to fix patient's position and geometrical discrepancies when performing radiation therapy on head and neck cancer patients, and compared the error before and after adjusting the position of patients due to difference in weight to evaluate the correlation between patients' weight and range of error. Computed tomography system(High Advantage, GE, USA) is used for phantom to maintain the supine position to acquire the images of the therapy site for IMRT. IMRT 4MV X-rays was used by applying the LINAC(21EX, Varian, U.S.A). Treatment planning system (Pinnacle, ver. 9.1h, Philips, Madison, USA) was used. The setup accuracy was compared with each measurement was repeated five times for each weight (0, 15, and 30Kg) and CBCT was performed 30 times to find the mean and standard deviation of errors before and after the adjustment of each weight. SPSS ver.19.0(SPSS Inc., Chicago, IL,USA) statistics program was used to perform the Wilcoxon Rank test for significance evaluation and the Spearman analysis was used as the tool to analyze the significance evaluation of the correlation of weight. As a result of measuring the error values from CBCT before and after adjusting the position due to the weight difference, X,Y,Z axis was $0.4{\pm}0.8mm$, $0.8{\pm}0.4mm$, 0 for 0Kg before the adjustment. In 15Kg CBCT before and after adjusting the position due to the weight difference, X,Y,Z axis was $0.2{\pm}0.8mm$, $1.2{\pm}0.4mm$, $2.0{\pm}0.4mm$. After adjusting position was X,Y,Z axis was $0.2{\pm}0.4mm$, $0.4{\pm}0.5mm$, $0.4{\pm}0.5mm$. In 30Kg CBCT before and after adjusting the position due to the weight difference, X,Y,Z axis was $0.8{\pm}0.4mm$, $2.4{\pm}0.5mm$, $4.4{\pm}0.8mm$. After adjusting position was X,Y,Z axis was $0.6{\pm}0.5mm$, $1.0{\pm}0mm$, $0.6{\pm}0.5mm$. When the holder for the head and neck cancer was used to adjust the ab.0ove error value, the error values from CBCT were $0.2{\pm}0.8mm$ for the X axis, $0.40{\pm}0.54mm$ for Y axis, and 0 for Z axis. As a result of statistically analyzing each value before and after the adjustment the value was significant with p<0.034 at the Z axis with 15Kg of weight and with p<0.038 and p<0.041 at the Y and Z axes respectively with 30Kg of weight. There was a significant difference with p<0.008 when the analysis was performed through Kruscal-Wallis in terms of the difference in the adjusted values of the three weight groups. As it could reduce the errors, patients' reproduction could be improved for more precise and accurate radiation therapy. Development of an adjustable device for head and neck cancer patients is significant because it improves the reproduction of existing equipment by reducing the errors in patients' position.