• Title/Summary/Keyword: 장비 가동율

Search Result 17, Processing Time 0.021 seconds

Statistical Characteristics and Rational Estimation of Rock TBM Utilization (암반굴착용 TBM 가동율의 통계적 특성 및 합리적 추정에 관한 연구)

  • Ko, Tae Young;Kim, Taek Kon;Lee, Dae Hyuck
    • Tunnel and Underground Space
    • /
    • v.29 no.5
    • /
    • pp.356-366
    • /
    • 2019
  • Various TBM performance prediction models have been developed and most of them were considered penetration rate only. Despite the fact that some models have suggested equations and charts for estimating the utilization factor, but there are a few studies to estimate the TBM utilization factor. Utilization factor is affected by the type of TBM machine, operation, maintenance of machine, geological conditions, contractor experience and other factors. In this study, more than 100 case studies are analyzed to determine the relationship between the utilization factor and RMR, geological conditions, TBM types, tunnel length, and TBM diameter. Simple and multiple linear regression analysis are performed to develop predictive models for the utilization factor. The predictive model with explanatory variables of geological conditions, TBM types, tunnel length, and TBM diameter does not give a good correlation. The predictive models with explanatory variable of RMR give higher values of the coefficient of determination.

Status and Plan of KMTNet Operation

  • Lee, Chung-Uk;Kim, Seung-Lee;Lee, Dong-Joo;Cha, Sang-Mok;Lee, Yongseok;Kim, Dong-Jin;Park, Hong Soo;Bang, Seung-Cheol;Kang, Hyunwoo;Hong, Sungwook E.;Kim, Jae-Woo
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.46 no.1
    • /
    • pp.59.1-59.1
    • /
    • 2021
  • 외계행성 탐색시스템 2020년 운영현황과 2021년 계획을 보고한다. 2020년은 코로나-19 팬데믹으로 인해 칠레와 남아공 관측소에서는 3월 중순부터 관측이 중단된 바 있으나, 연말부터 재가동을 시작하여 2021년 현재 3개 관측소가 모두 정상가동하고 있다. 2020년 관측장비 가동율은 99.3% 이었다. 천문박명시간 기준으로 5877.2 시간이 할당되었고, 이중 4069.7 시간 동안 관측이 이루어져 관측율은 75.2% 이었다. 이 발표에서는 2020년 날씨통계 및 주요 관측 장비의 성능 개선과 함께 2021년 관측 및 시스템 개선 계획을 소개한다.

  • PDF

Study on the Workability of Raise Boring Machine in Korea (국내 Raise Boring Machine의 굴착능력에 관한 연구)

  • 이석원;조만섭;배규진
    • Tunnel and Underground Space
    • /
    • v.13 no.3
    • /
    • pp.196-206
    • /
    • 2003
  • In order to investigate the workability of Raise Boring Machine(RBM) such as utilization, penetration rate and advance rate, a vertical shaft of 98 m in length and 3.05 m in diameter was constructed in the layer of conglomerate by using the RBM in this study. In addition, field data from tow different construction sites including water-pump power plant tunnel, roadway tunnel and mining tunnel by RBM were collected and analyzed. The results show that the average weekly bored length is 19.3 m and its average utilization is between 54.3 % and 75.1 % very higher than that of the TBM(Tunnel Boring Machine). It also turns out that the bit force increases linearly with respect to the increase of the RPM(revolution per minute) of RBM. However, the net penetration rate decreases with the increase of bit force, RPM of RBM and depth of shaft. The findings of this study can be used to provide the useful information for the design of shaft and the selection of RBM.

비용과 최소요구충족율을 고려한 수리가능제품의 최적여유부품수준의 결정기법

  • 신규철;김종수
    • Proceedings of the Korean Operations and Management Science Society Conference
    • /
    • 1993.04a
    • /
    • pp.215-224
    • /
    • 1993
  • 본 논문에서는 고가의 수리가능제품의 최적여유재고 수준을 결정하는 효율적인 방법을 제안한다. 고려하는 시스템은 각 기지창과 중앙창에서 한정된 수리능력을 가지며 중앙창에서 수리가 끝난 후 수리된 제품은 원래의 기지창으로 되돌아가서 재고에 포함되는 형태이다. 제안한 방법은 최소비용의 재고수준을 결정하는 방법 및 최소요구충족율을 가장 적은 비용으로 만족시키는 여유재고수준을 결정하는 최적해법이다. 제안한 방법을 실제시스템에 적용하면 최소의 비용으로 장비나 무기를 원하는 수준으로 가동시킬 수 있으므로 국방비의 효율적인 사용 및 절감에 도움이 될 것이다.

  • PDF

A Case Study on the Cost Effectiveness Analysis of Depot Maintenance Using Simulation Model and Experimental Design (시뮬레이션 모형과 실험설계법을 활용한 창정비 비용대 효과 분석 사례)

  • Kim, Sung-Kon;Lee, Sang-Jin
    • Journal of the Korea Society for Simulation
    • /
    • v.26 no.3
    • /
    • pp.23-34
    • /
    • 2017
  • This paper is to study the simulation model of depot maintenance system that analyzes logistics supportability such as component availability and cost of target equipment. A depot maintenance system could repair or maintain multiple components simultaneously. The key performance indicators of this system are component availability, repair cycle time, and maintenance cost. The simulation model is based on the engine maintenance process of army aviation depot. This study combines the NOLH(Nearly Orthogonal Latin Hypercube) experimental design method, to composes 33 scenarios, with a multiple regression analysis to find out major factors that influence on key performance indicators. This study is significant in providing a cost-effectiveness analysis on depot maintenance system that is capable of maintaining multiple components at the same time.

Statistical analysis of failures of a medical linear accelerator over ten years (선형가속기의 10년간 관리 자료를 바탕으로 한 통계분석)

  • Ju, Sang-Gyu;Huh, Seung-Jae;Han, Young-Yih;Seo, Jeong-Min;Kim, Won-Kyou;Kim, Tae-Jong;Park, Young-Hwan
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2004.11a
    • /
    • pp.158-161
    • /
    • 2004
  • In order for better management of a medical linear accelerator, the records of the operational failures of Varian CL2100C over ten years were analyzed. The failures were classified according to the involved functional subunits and each class was rated into three levels depending on operational conditions. The relationship between the failure rate and working ratio was investigated. Among the recorded failures ( total 587 failures), the most frequent failure, which was 20% of the total. was observed in the parts related to the collimation system including monitor chamber. Regrading to the operational conditions, the 2nd level of failures, that temporally interrupted treatments, was the most frequent. The 3rd level of failures, that interrupted treatment for more than several hours, was mostly caused by the accelerating subunit. The average life-time of a Klystron and Thyratron became shorter as the working ratio increased, which was 42 and 83% of the expected values, respectively. Recording equipment problems and failures in detail over a long period of time can provide a good knowledge of equipment function as well as the capability to forecast future failure. More rigorous equipment maintenance is required for old medical linear accelerator to avoid the serious failure in advance, and improve the patient treatment quality.

  • PDF

KCCH Medical Cyclotron Operation for Neutron Therapy and Isotope Production (1989) - A Technical Report - (중성자 치료와 동위원소 생산을 위한 KCCH 의학용 싸이클로트론의 운영 (1989))

  • Kim, Byung-Mun;Kim, Young-Sear;Bak, Joo-Shik;Lee, Jong-Du;Yoo, Seong-Yul;Koh, Kyung-Hwan
    • Journal of Radiation Protection and Research
    • /
    • v.15 no.2
    • /
    • pp.113-122
    • /
    • 1990
  • After four years of planning, equipment acquisition, facility construction and beam testing, the KCCH cyclotron facility was put into operation in November1986. Now the KCCH cyclotron(MC-50) has been used for four years in neutron therapy and radioisotope production. Up to December 1989, 179(1852 sessions) patient have undergone neutron therapy. Radioisotope production for nuclear medicine use was started from March 1989 after extensive work to overcome target transport, target melting, beam diagnostic and chemical processing problems. This status report introduces the cyclotron facility, and the experiences of neutron therapy and isotope production with the MC-50 cyclotron. Besides, the operation results and the general troubles of the MC-50 during 1989 are summarized. Total operation time was 1252.5 hours. Four hundred hours were used for neutron therapy of 599 treatment sessions and 832.5 hours for radioisotope production. Total amount of produced raioisotope was 1695 mCi(Ga-67 : 1478mCi, Tl-201 : 107 mCi, I-123 : 25mCi, In-111 : 85mCi). Twenty hours were used for scheduled beam testing. In 1989, 882% of the planned operation were performed on schedule and this rats is improved remarkably compared to 71.0% in 1988.

  • PDF

Survey Study of Optimal Cooling Equipment Capacity of the Large Hospitals in Busan City (부산지역 대형병원 냉방장비의 용량설정 실태조사)

  • Lee, Ji-Weon;Chin, Kyung-Il;Kim, Se-Hwan
    • KIEAE Journal
    • /
    • v.14 no.6
    • /
    • pp.105-110
    • /
    • 2014
  • The basic factors determining the amount of energy used in hospital buildings are weather conditions and building factors. But the real energy consumer is central plant equipment such as boilers and chillers that produce thermal energy for heating and cooling. Inaccurate decision of the primary equipment's size can cause a high initial-cost, an excessive equipment space, a wasted energy by low operation-efficiency and shortening of the machine's life. In this reason, the decision of optimal size for central plant equipment is very important. There are several factors for the decision such as an operation factor, a factor (equipment factor), piping losses and a simultaneous usage factor applied in the sizing process except a basic cooling load. But there is no standard method for applying those factors. Usually, factors are applied individually by an experience or custom of each engineer. In this study, the authors emphasize the meaning and the problem of those factors, examine them by analyzing factors which were applied to actual practices, and propose the recommendation value of safety, load, operation factors and application methods.

The Status and Plan of KMTNet Operation

  • Lee, Chung-Uk;Kim, Seung-Lee;Lee, Dong-Joo;Cha, Sang-Mok;Lee, Yongseok;Kim, Dong-Jin;Kim, Hyun-Woo;Shin, Min-Su;Park, HongSoo;Lim, Jin-Sun;Park, Byeong-Gon
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.43 no.1
    • /
    • pp.39.3-39.3
    • /
    • 2018
  • 외계행성 탐색시스템 운영현황과 계획을 소개한다. 2017년 관측장비 가동율은 97.4% 이며, 시스템이 설치된 3개 천문대에서 천문박명시간을 기준으로 총 10,157 시간이 연구에 할당되었고 총 7,178 시간 관측이 이루어졌다. 관측시스템의 성능개선을 위해 주경 코팅, 돔 레벨조정, 망원경 구동롤러 정렬, 주경 배플 마스크 설치 등 돔과 망원경의 기계부 업그레이드와 카메라 전자부 조정 및 앰프보드 교체 등이 이루어졌다. 관측효율 향상을 위해 1년간 관측된 약 177,000 장의 자료를 분석하여 불량자료 태깅기반을 마련했고, 시상모니터링과 관측 스크립트 코드를 개발하여 현재 관측에 적용하고 있다. 관측 자료는 각 연구 프로그램의 자료공개 정책에 따라 영상형태 또는 측광 파일형태로 이용이 가능하며, 관측로그는 홈페이지를 통해 확인할 수 있다. 2020년 10월부터 시작되는 2단계 관측 프로그램 선정을 위해 2019년 상반기에 관측제안서를 접수받아 하반기에 선정을 마칠 계획이며, 다양한 연구주제 발굴을 위해 파일롯 프로그램을 선별 지원할 계획이다.

  • PDF

Present State Analysis of Customers' Effect in Power Distribution System by Momentary Voltage Variation (배전계통의 순시전압변동에 의한 수용가측 영향의 현황 분석)

  • 김재철;윤상윤;오정환;임성정
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.12 no.4
    • /
    • pp.37-46
    • /
    • 1998
  • This paper analyzes the present state of customers' effect in distribution system by momentary voltage variation. Customers are becoming increasingly concerned about the quality of electric power. Most of all, the voltage magnitude quality is very important because it can have a direct effect on customers. Especially, according to the development of automatic process, momentary voltage variations result in the shutdown of sensitive loads such as electronic equipment, computer and magnetic contactor, and so on. To analyze the shutdown rate of customers' equipments by the momentary voltage variation, we present the CVEMA curve and he cumulative CVEA curve of each load type through the experiment for the customers' sensitive equipments. Also, we have surveyed customers' opinion by the questionnaire as "Survey of Power Quality" an then the results are reported.

  • PDF