• Title/Summary/Keyword: 잔향 음장

Search Result 41, Processing Time 0.022 seconds

Analysis of Sound field in a Reverberation room (잔향실의 음장해석)

  • 권영필;임정빈;이주원;이득웅
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1996.10a
    • /
    • pp.124-129
    • /
    • 1996
  • 잔향실의 내부 음장을 해석한 결과 다음과 같은 결론을 얻을 수 있었다. 1) 벽면의 흡음률이 동일한 경우는 음향 임피던스의 실수항과 허수항의 변화, 즉 위상의 변화에 따른 음장의 변화가 없다. 2) 5각 형태의 잔향실은 벽면의 흡음률 변화에 따른 음장의 변화가 없다. 3) 4각 형태의 잔향실은 5각 형태의 잔향실보다는 음장이 불균일하며 벽면의 흡음률이 증가함에 따라 음압레벨이 표준편차가 커진다.

  • PDF

Development of an efficient sound field reproducing algorithm for home theater systems (효과적인 홈시어터용 음장재생 알고리즘 개발)

  • Shim Hwan;Lee Sin-lyul;Yoo Jae-hyoun;Sung Koeng-Mo
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • autumn
    • /
    • pp.531-534
    • /
    • 2004
  • 음장 재생기는 인공잔향기의 일부로 알려져 있었으나 실제로는 다른 접근 방법이 필요하다. 인공잔향기의 용도가 대체로 무향에 가까운 음원에 인공잔향을 가해주는 것이라면, 음장 재생기는 청취자에게 넓은 공간감을 위해 이미 잔향이 가해진 음원에 초기반사음만을 가해주기 때문이다. 본 논문에서 제안하는 음장재생기는 모사하고자 하는 공간의 충격응답에서 직접음 대비 반사음의 세기를 조절하여 sound coloration을 줄이고, 초기반사음의 패닝을 이용하여 넓은 공간감을 효과적으로 재생한다. 또한 본 음장재생기는 ITDG, LEF, Stage width, Room size, Liveness 등의 객관적 인자들을 조정할 수 있기 때문에 원하는 공간의 모사뿐 아니라 가상공간의 크기와 느낌을 변화시킬 수 있다.

  • PDF

Design of Multi-Channel Sound Field Reproduction (멀티 채널 음장 재생 시스템의 설계)

  • 김영오
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • 1998.06c
    • /
    • pp.265-268
    • /
    • 1998
  • 본 논문에서는 1채널(mono)이나 2채널(stereo)의 오디오 입력을 5채널(center, left, right, left side, right side)로 출력시키는 음장 시스템을 설계하고 그 성능을 분석하였다. 가정의 리스닝 룸 같이 작은 공간에서 콘서트 홀 같은 커다란 공간의 음장을 재현하기 위한 멀티 채널 음장 시스템은 지연기, 초기 반사음처리기, 잔향기를 이용해 설계하였다. 초기 반사음 처리기의 지연과 이득은 실제 공간에서 측정한 암펄스 응답을 이용하여 결정하였으며, 구현된 초기 반사음을 전방 30$^{\circ}$방향에서 재생함으로써 확장감을 증가시킬 수 있도록 하였다. 잔향기는 자연스러운 주파수 및 감쇠 특성을 갖도록 설계되었으며, 후방 60$^{\circ}$방향에서 재생되는 잔향의 상관 계수를 작게 함으로써 청취시 공간감을 느끼게 하였다. 설계된 음장 시스템은 무향실 데이터를 입력으로 시뮬레이션되었고, 그 결과로 얻어진 5개의 PCM 출력은 멀티 트랙 재생 장치에 의해 일반 리스닝 룸에서 재생된다.

  • PDF

Sound Field Control System for Multipurpose Halls (다목적 홀의 음장 가변 시스템)

  • Kang Sung-Hun;Lee Jai-Won
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • autumn
    • /
    • pp.283-286
    • /
    • 2001
  • 본 논문은 전기적으로 음장을 가변하여 청감적 인상에 변화를 주는 실험 결과를 기술하였다. 본 실험은 마이크로폰으로 무대의 음원을 수음하고 잔향기로 옆방향 반사음과 잔향음을 각각 생성하여 스피커로 출력하였다. 실험 결과 실내의 청감적 인상이 개선됨을 확인하였다. 또 음원 수음 시 발생하는 하울링, 실내 잔향과 다른 스피커의 음색, 잔향기에서 발생하는 음색 변조 둥 기술적 문제를 해결하였다.

  • PDF

Acoustic Characteristics of Sound Field in Partially Opened Rooms -Emphasis on Vertical Coupling of Diffuse and Free Field- (실내공간의 부분적 개방에 따른 음향특성변화 II -확산음장과 자유음장의 수직적 결합을 중심으로-)

  • Jeong, Dae-Up;Choi, Young-Ji
    • Journal of Korean Association for Spatial Structures
    • /
    • v.7 no.5
    • /
    • pp.75-82
    • /
    • 2007
  • The present work measured and analyzed changes in the acoustics of a sound field which has a retractable ceiling. An 1/20 scale model of an openable space was built and measurement was carried out by varying the opened area of a ceiling. The most widely used room acoustic and design parameters, RT, EDT, and D50 were investigated. The results suggest that the use of RT as an acoustic design parameter may not be proper in an openable space and further it is likely to mislead the initial acoustic design of such spaces. It is mainly due to the characteristics of RT in which non-exponential decay processes are linearly fitted. Early decay times were found to be decreased in proportion to increaing the ratio of opened area. D50, an index of speech intelligibility, was effectively shows the influence of openings on the acoustics. It is also found that EDT and D50 at the seats, not directly exposed to the opened part of a ceiling, were almost linearly decreased in proportion to the ratio of opened area, while little influence was found for the opening ratio larger than 40% at the directly exposed seats to the opened part of a ceiling.

  • PDF

Acoustic characteristics of sound field in partially opened rooms - Emphasis on horizontal coupling of diffuse and non-diffuse field - (실내공간의 부분적 개방에 따른 음향특성변화 I - 확산음장과 자유음장의 수평적 결합을 중심으로 -)

  • Jeong, Dae-Up;Choi, Young-Ji;Kim, Ji-Young;Oh, Yang-Ki;Choi, Seok-Ju
    • Journal of Korean Association for Spatial Structures
    • /
    • v.7 no.2 s.24
    • /
    • pp.105-114
    • /
    • 2007
  • Large span spaces have been widely used for various purposes including sports events in other countries. Due to increasing demands on multi-purpose use of such spaces, recently built large span sport facilities such dome stadiums have been required to accommodate sport events as well as performing events. Also, retractable ceilings and/or walls were generally adopted in those spaces for providing various event conditions. It seems obvious that the openings between diffuse fields and free field may cause difficulties in the acoustic design of such spaces In the present work, the acoustic characteristics of non-diffuse field has been investigated using 1/10 acoustic scale models. It was found that RTs at low- and mid-frequencies decayed faster than those at high-frequencies as the percentage of opening area increased. The decay rate of RTs at high frequencies were not influenced by increasing the area of an opening. Also high dependence of EDT on the percentage of opening area was observed at all frequency range. D50 was not improved by increasing the area of an opening up to 12.5% and then sharply increased. The application of Schroeder integration to evaluate the reverberation charateristics of coupled spaces may not be proper, since non-exponential decay process with double or triple decays of those spaces can not be properly defined. EDT seems more appropriate to predict reverberation at the early acoustic design stage of acoustically coupled spaces.

  • PDF

Study on method of build up low-frequency diffuse sound field in a scaled reverberation chamber (축소잔향실의 저주파수 확산음장 형성 방법에 대한 연구)

  • Kang, Jun-Goo;Kang, Hyun-Ju;Kim, Sang-Ryul;Choi, Jong-Soo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.05a
    • /
    • pp.61-64
    • /
    • 2007
  • This study is dealt with a method to enhance low-frequency diffuse sound field in a scaled reverberation chamber. Because scaled reverberation chamber has not enough room volume, as a result, it shows a few room modes. So it is not build up low-frequency diffuse sound field. A Helmholtz resonator's arrangement is used to improve spatial uniformity of sound pressure at low frequency. The spatial distribution of sound field has been measured before and after control. The standard deviation of sound field has decreased at 315Hz 1/3 Octave band.

  • PDF

Active Noise Control of Reverberant Sound Field Using the Multi-Channel Adaptive Algorithm (다채널 적응 알고리즘을 이용한 잔향 음장에서의 능동소음제어에 관한 연구)

  • Kim, H.S.;Sohn, D.G.;Oh, J.E.
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.3 no.6
    • /
    • pp.23-29
    • /
    • 1995
  • In this study, Active noise controlis implemented with single channel and multi-channel adaptive algorithm in 3 dimensional reverberant enclosure sound. field, which occurrs in complicated acoustic mode. First, for the one case excited with the resonant frequency of an enclosure, a target of control and the other cases excited with band-pass filtered random noise(100~400Hz), it is implemented to control reducing interior noise of enclosure with single channel and realtime multi-channel adaptive algorithm for global noise reduction in enclosure.

  • PDF

The Study on Correction Factor of a Small Scale Reverberation Chamber to Estimate Transmission Loss (소형 잔향실의 확산 음장 보정 계수 측정 연구)

  • Kim, Tae Min;Kim, Da Rae;Kim, Jeung Tae
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2014.10a
    • /
    • pp.960-965
    • /
    • 2014
  • Transmission loss of specimen is calculated by measuring energy of incident and transmission and using reverberant room of large size. But normal measurement of transmission loss has trouble because it is actually demanded that large area and specimen of certain size is satisfied with condition of diffused sound field. Especially, in case of mechanical component, interested frequency band is mid-frequency band between 500 ~ 2k Hz, and it is used to be available to minimize a reverberation chamber under conditions satisfying acoustic one because production of specimen for transmission loss measurement has limit. But, as in semi-reverberation room, it is difficult to satisfy condition of diffuse sound field and modification factor is applied to complement that. Correction factor when measuring transmission loss using semi-reverberation chamber is required accuracy because it works as main factor determining reliability of reuslts on transmission loss. In this study, it is analyzed that an effect on correction factor based on varying materials and sizes of specimens in order to deduction of it. Also It is confirmed that applied by elicited correction factor with actual railway vehicle's floor has reliability.

  • PDF