• 제목/요약/키워드: 잔열제거 열교환기

검색결과 7건 처리시간 0.02초

가동원전 잔열제거계통 배관에서의 열성층유동 해석 (An Analysis on Thermal Stratification in Residual Heat Removal System Piping of Nuclear Power Plant)

  • 박만홍;김광추;김경훈
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 춘계학술대회
    • /
    • pp.1597-1602
    • /
    • 2003
  • Numerical analysis is carried out to assess the temperature distribution on the mixing tee line of Residual Heat Removal System (RHRS). In RHRS, hot and cold fluids of main and bypass piping are mixed and unmixed by the flow rate or piping layout. Thermal stratification phenomenon is a cause of major degradation on RHRS piping. According to the analysis for each operation modes, maximum temperature difference between top and bottom of piping were evaluated about 60K when the flow rate of main and bypass lines is same. Temperature difference will be decreased at the elbow on RHRS piping if the length of vertical piping is increased.

  • PDF

소듐냉각고속로 잔열제거계통 강제대류 소듐-공기 열교환기의 구조개념 설계 (Structural design concept of the forced-draft sodium-to-air heat exchanger in the decay heat removal system of PGSFR)

  • 김낙현;이사용;김성균
    • 한국압력기기공학회 논문집
    • /
    • 제12권1호
    • /
    • pp.78-84
    • /
    • 2016
  • The FHX (Forced-draft sodium-to-air Heat Exchanger) employed in the ADHRS (active decay heat removal system) is a shell-and-tube type counter-current flow heat exchanger with M-shape finned-tube arrangement. Liquid sodium flows inside the heat transfer tubes and atmospheric air flows over the finned tubes. The unit is placed in the upper region of the reactor building and has function of dumping the system heat load into the final heat sink, i.e., the atmosphere. Heat is transmitted from the primary cold sodium pool into the ADHRS sodium loop via DHX (decay heat exchanger), and a direct heat exchange occurs between the tube-side sodium and the shell-side air through the FHX tube wall. This paper describes the DHRS and the structural design of the FHX.

다관원통형 열교환기의 파울링 해석기법 개발 연구 (A Study on the Development of Fouling Analysis Technique for Shell-and-Tube Heat Exchangers)

  • 황경모;진태은
    • 대한기계학회논문집B
    • /
    • 제28권2호
    • /
    • pp.167-173
    • /
    • 2004
  • Fouling of heat exchangers is generated by water-borne deposits, commonly known as foulants including particulate matter from the air, migrated corrosion produces; silt, clays, and sand suspended in water; organic contaminants; and boron based deposits in plants. The fouling is known to interfere with normal flow characteristics and reduce thermal efficiencies of heat exchangers. This paper describes the fouling analysis technique developed in this study which can analyze the thermal performance for heat exchangers and estimate the future fouling variations. To develop the fouling analysis technique fur heat exchangers, fouling factor was introduced based on the ASME O&M codes and TEMA standards. For the purpose or verifying the fouling analysis technique, the routing analyses were performed for four heat exchangers in several nuclear power plants; two residual heat removal heat exchangers of the residual heat removal system and two component cooling water heat exchangers of the component cooling water system.

일체형 원자로의 공랭식 열교환기 개념 연구 (A Conceptual Study of an Air-cooled Heat Exchanger for an Integral Reactor)

  • 문주형;김우식;김영인;김명준;이희준
    • 한국유체기계학회 논문집
    • /
    • 제19권2호
    • /
    • pp.49-54
    • /
    • 2016
  • A conceptual study of an air-cooled heat exchanger is conducted to achieve the long-term passive cooling of an integral reactor. A newly designed air-cooled heat exchanger is introduced in the present study and preliminary thermal sizing is demonstrated. This study mainly focuses on feasibility of an innovative air-cooled heat exchanger to extend the cooling period of the passive residual heat removal system(PRHRS) only in passive manners. A vertical shell-and-tube air-cooled heat exchanger is installed at the top of the emergency cooldown tank(ECT) to collect evaporated steam into condensate, which enables water inventory of the ECT to be kept. Finally, thermal sizing of an air-cooled heat exchanger is presented. The length and the number of tubes required, and also the height of a stack are calculated to remove the designated heat duty. The present study will contribute to an enhancement of the passive safety system of an integral reactor.

소듐냉각고속로 붕괴열교환기의 고온 설계 및 건전성 평가 (High-Temperature Design and Integrity Evaluation of Sodium-Cooled Fast Reactor Decay Heat Exchanger)

  • 이형연;어재혁
    • 대한기계학회논문집A
    • /
    • 제37권10호
    • /
    • pp.1251-1259
    • /
    • 2013
  • 본 연구에서는 소듐냉각 고속로 붕괴열교환기(DHX)의 고온 설계 및 크리프-피로 손상 평가를 수행하였다. 제 4 세대 소듐냉각 고속로의 능동 및 피동 잔열제거계통에 설치되는 DHX와 한국원자력연구원의 STELLA-1 시험루프에 설치된 DHX에 대해 상세설계 및 3D 유한요소해석을 수행하고, 동 결과에 기초하여 고온설계 기술기준인 ASME Section III Subsection NH와 RCC-MR 코드를 따라 크리프-피로 손상평가를 수행하였다. 크리프-피로 손상평가 결과에 기초하여 두 설계기준에 대해 비교 분석하고, 설계 기술기준의 보수성 이슈에 대해 토의하였다.

차세대 원자로 정지냉각계통의 냉각 성능에 대한 연구 (A Study of Cooldown Performance of Shutdown Cooling System of Korea Next Generation Reactor)

  • 유성연;이상섭
    • 에너지공학
    • /
    • 제8권4호
    • /
    • pp.525-532
    • /
    • 1999
  • 한국형 차세대 원자로는 ABB-CE사의 System 80+의 설계개념을 근간으로 하여 표준화된 원자로의 계통설계를 추진하고 있다. 본 연구에서는 차세대 원자로 정지냉각계통의 운전시 요구되는 인허가 요건등제반 조건을 충족시킬 수 있는지를 해석하였다. 또한 운전시 필요한 열교환기의 유효면적과 원자로 기기냉각수 유량등 기본적인 설계자료를 산출하여 차후 차세대 원자로 정지냉각계통의 상세설계 업부를 수행하는데 필요한 기초자료를 제시하여 핵증기공급계통 (NSSS)의 기술개발을 이루는데 목적이있다. 차세대 원자로는 울진 3, 4호기 열출력 2.825MWth 에 비해 열출력이 4,000MWth 로 증가되어 정지냉각계통의 관련서례자료를 새로 산출해야하므로 정지냉각계통의 냉각능력을 평가하는 KDESCENT 전산코드를 이용하여 원자로 노심의 잔열과 정지냉각계통의 현열을 제거할 수 있는 최소 유량을 제시하였으며 주요 구성기기인 열교환기, 펌프, 밸브 및 기타 기기의 기능 및 정지냉각계통의 운전절차를 고찰하였다.

  • PDF

중수로 정지냉각계통의 냉각능력 분석 (Analysis of Cooldown Capability for the HWR Shutdown Cooling System)

  • 신정철
    • 에너지공학
    • /
    • 제20권4호
    • /
    • pp.259-266
    • /
    • 2011
  • 원자로 정지냉각계통은 원자로 정지 시 핵연료 잔열 제거를 위하여 냉각수가 충분히 공급하고 원자로기기들을 보호할 수 있는 냉각율을 유지할 수 있도록 설계되어야 한다. 경수로 정지냉각계통을 분석하기 위한 KDESCENT코드를 중수로 정지냉각계통에 적용하여 보았으며 기존의 중수로형 해석코드인 SOPHT, SDCS 코드 결과와 비교분석하였다. 정지냉각펌프 모드와 열수송펌프 모드에서 정상냉각 운전상태는 계통의 설계 요건을 만족시켰으며 정지냉각 열교환기를 열제거원으로 사용하였을 때 냉각률은 설계요건에서 규정하고 있는 제한치인 $2.8^{\circ}C/min$ 이하의 값을 얻었다. 전반적인 냉각능력 분석 결과 월성 2, 3, 4호기 정지냉각계통은 핵연료로부터 핵분열 생성물의 방출을 충분히 제한하고 핵연료채널의 건전성을 유지시키기 위한 충분한 냉각을 핵연료에 제공하였다.