Analysis of Cooldown Capability for the HWR Shutdown Cooling System  

Sin, Jeong-Cheol (Mechanical, Automotive & Air Conditioning Department, Woosong College)
Publication Information
Abstract
Following the reactor shutdown, the reactor shutdown cooling system must be designed to supply the coolant sufficiently not only to remove the decay heat but to maintain the adequate cooling rate to protect the reactor equipments. In this study, KDESCENT code for the light water reactor and SOPHT, SDCS codes for the heavy water reactor were compared and analyzed to investigate the cooling capability during the shutdown cooling process. The shutdown cooling system design requirements were satisfied during cooling process for both the SDCP and the HTP modes and the design cooling rate of $2.8^{\circ}C/min$ or below was maintained using the SDC heat exchangers. This study shows that the shutdown cooling system in the Wolsong 2, 3, 4 reactors provides sufficient cooling to maintain the nuclear fuel integrity by removing the decay heat of the nuclear fission product.
Keywords
heavy water reactor; reactor shutdown cooling system; cooling rate; nuclear fuel integrity; shutdown cooling pump;
Citations & Related Records
연도 인용수 순위
  • Reference
1 A. J. Adams, "Design Manual for Service Water inside Service Building for Wolsong-1 Nuclear Power Plant" DM-0059-71300-01, Rev. 1, Dec. 1980.
2 S. J. Baik, "Design Manual for Primary Heat Transport System for Wolsong-2" 86-33100/63310-DM-000, Rev. 0, Dec. 1992.
3 B. Zhai, "Design Manual for Shutdown Cooling Sysytem for Wolsong-2" 86-33410 /63341-DM-000, Rev. 0, Nov. 1992.
4 J.K.Ha, A.H.Stretch, "System Classification List, Nuclear Steam Supply System for Wolsong 2" 86-01345-SCL-001, Jan. 1992.
5 R. Abdallah, "Design Manual for Reactor Building Recirculated Cooling Water System for Wolsong 2 Nuclear Power Plant" 86-71340/67134-DM-000, Rev. 1, Mar. 1992.