• Title/Summary/Keyword: 작동성

Search Result 2,098, Processing Time 0.03 seconds

Design and Demonstration of Morphing Wing Sections Using Lightweight Piezoceramic Composite Actuator (LIPCA) (압전 작동기 LIPCA를 이용한 형상가변익 설계 및 작동구현)

  • Im,Sang-Min;Lee,Sang-Gi;Park,Hun-Cheol;Yun,Gwang-Jun;Gu,Nam-Seo
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.31 no.10
    • /
    • pp.34-39
    • /
    • 2003
  • Morphing wing sections actuated by piezoceramic actuator LIPCA have been designed and their actuation displacements estimated by using the therml analogy and MSC/NASTRAN based on the linear elasticity. The wing sections are fabricated as the design and tested for evaluation. Measured actuation displacements were larger than the estimated values mainly due to the material non-linearity of the PIT wafer. The morphing wing sections can be used for control surfaces of small scale UAVs or MAVs.

항공기의 공탄성 제어를 위한 압전재료의 응용

  • 남창호;이근명
    • Journal of KSNVE
    • /
    • v.6 no.1
    • /
    • pp.11-19
    • /
    • 1996
  • 지금까지의 항공기 날개에 공력 탄성학적 제어를 위해 압전재료를 작동기로 사용하는 연구는 아직은 완전하지 못하지만 실용화 가능성을 조사하기 위해 집중적인 투자가 행해지고 있다. 본 글에서 언급한 예 외에도 압전재를 이용 날개의 익형을 능동적으로 조절함으로써 천음속에서의 저항을 줄이기 위한 연구(transonic drag reduction with piezos), 압전재로 작동하는 제어면을 부착하여 헬리쿱터 블레이드 의 진동을 제어하기 위한 실험적 연구, 항공기 외부 장착물에 의해 발생되는 불안정 성을 제어하기 위한 압전작동기를 사용한 pylon decoupler 설계 등 다양한 분에에서 연구가 되고 있다. 하지만 아직까지는 제어에 필요한 충분한 제어력을 얻는 문제, 주 구조물과 압전재료의 강성도의 차이, 가용한 압전재의 실용화, 내구성 문제 등 항공 기에의 응용을 위한 새로운 재료의 개발이 요구되고 있다. 그리고 사용에 필요한 전력을 공급하는 문제는 지상에서 작동되는 시스템과는 달리 항공기에서는 해결해야 될 큰 문제점이며, 이에 대한 연구가 요구되고 있으며, 실용 가능성이 보일 경우 재료의 내구성, 제어 성능, 번개 등 외력에 대한 손상 예측 등 광범위한 연구가 이어 질 것으로 예측된다.

  • PDF

제트 펌프의 작동 특성

  • Shim, Yun-Seop;Wi, Myeong-Hwan;Kim, Yeon-Sik;Lee, Jun
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1996.05b
    • /
    • pp.148-153
    • /
    • 1996
  • 일반구동 펌프에 제트 펌프를 결합시킨 복합 펌프 체제의 기본 특성 파악을 위하여 일차원 유동 모형을 이용하여 제트 펌프 자체의 기본적인 작동 특성을 분석하고 복합체제에서의 설계인자와 성능인자간의 상관성을 분석하여 제트 펌프의 일반적인 작동조건도를 작성하였고 바람직한 제트 펌프 구동을 위한 지표를 설정하였다.

  • PDF

2상 밀폐 열사이폰 루프의 전열특성 및 안정성에 관한 연구

  • 이진호;김태열;설신수;이병일
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.14 no.4
    • /
    • pp.971-980
    • /
    • 1990
  • 본 연구에서는 실험적으로 2상 밀폐 직사각형 열사이폰 루프에 대하여 안정성 에 주된 영향을 줄수 있는 변수들, 즉 루프 경사각도, 작동유체의 유동현상을 관찰하 고 작동유체의 온도변동과 류프의 전열성능을 측정하여 열사이폰이 안정하게 작동하는 범위를 종합적으로 조사해 보았다.

Periodically operating absorption heat pumps (주기적으로 작동하는 흡수식 열펌프)

  • Knoche K. F
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.16 no.5
    • /
    • pp.463-476
    • /
    • 1987
  • 주기적으로 작동하는 흡수식 장치가 부착된 직접 연소식 고효율 난방기기를 특정 공간 난방 목적으로 설계하여 제작하였다. 작동 유체는 메타놀/물-리치움브로마이드이다. 네개의 구성품으로 된 이 기기에는 동작부품이 없다. 제 1 시제품의 결과와 경험에 기반을 두고 개선형 시제품을 설계, 제작하였다. 현재까지 발생기-응축기 모듈이 설치되어 보일러 운전모드 결과가 확립되어 있다. 또한 난방기기의 경제성과 작동 유체의 안정성 연구가 중요한 부수 조건을 확립하기 위하여 수행되고 있다.

  • PDF

Numerical Simulation of Self-Compensating Dynamic Balancer in a Rotating Mechanism (수치해석을 통한 자기보상 동적균형기의 작동성 검토)

  • 이종길
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.12 no.1
    • /
    • pp.142-151
    • /
    • 1995
  • 회전체의 자동밸런싱을 위하여 고안된 자기보상 동적균형기는 홈이파인 원판에 강구와 저점성유체를 지닌 구조체이다. 유도된 운동방정식으로 부터 자기보상 동적균형기의 작동조건을 조사하기 우하여 수치해석을 통한 동 특성을 검토하였다. 수치해석의 결과에 근거하여 임계속도보다 높은 범위에서는 자기보상 동적균형기는 정상작동을 보여주었다. 임계속도에서는 회전계의 균형이 강구와 점성유체와의 감쇠계수에 의존하였으나 임계속도보다 낮은 범위에서는 어떠한 조건에 대해서도 작동하지 않음을 알 수 있었다. 자동차 및 항공기에도 응용가은한 자기보상 동적균형기의 작동조건들을 본 논문에서 예시하였다.

  • PDF

시간지연추정 슬라이딩모드제어기와 형상기억합금 작동기를 위한 적용

  • 이효직;이정주;김종호;이정일;강대임
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.05a
    • /
    • pp.172-172
    • /
    • 2004
  • 형상기억합금 작동기는 스마트 작동기의 대표주자로서 부피 대비 발생력이 다른 어느 재료보다 우수하고, 모터와 같은 작동소음이 발생하지 않으며, 온도변화에 의한 간단한 작동원리로 근래에 많은 연구자들의 관심을 받아왔다 그러나, 온도변화 대 변위 곡선을 살펴보게 되면 이력곡선, 포화현상 등의 강한 비선형성을 내제하고 있고, 대류조건에 따른 온도외란에 민감하다. 이로 말미암아 정밀한 위치제어에 상당한 문제를 수반하고 있으며, 기존의 PID제어기나, 모델기저 제어기를 사용하게 될 경우 정상 상태오차와 한계싸이클 등의 현상이 나타나는 것으로 문헌에 보고되고 있다.(중략)

  • PDF

Probabilistic Calibration of Computer Model and Application to Reliability Analysis of Elasto-Plastic Insertion Problem (컴퓨터모델의 확률적 보정 및 탄소성 압착문제의 신뢰도분석 응용)

  • Yoo, Min Young;Choi, Joo Ho
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.37 no.9
    • /
    • pp.1133-1140
    • /
    • 2013
  • A computer model is a useful tool that provides solution via physical modeling instead of expensive testing. In reality, however, it often does not agree with the experimental data owing to simplifying assumption and unknown or uncertain input parameters. In this study, a Bayesian approach is proposed to calibrate the computer model in a probabilistic manner using the measured data. The elasto-plastic analysis of a pyrotechnically actuated device (PAD) is employed to demonstrate this approach, which is a component that delivers high power in remote environments by the combustion of a self-contained energy source. A simple mathematical model that quickly evaluates the performance is developed. Unknown input parameters are calibrated conditional on the experimental data using the Markov Chain Monte Carlo algorithm, which is a modern computational statistics method. Finally, the results are applied to determine the reliability of the PAD.

A Study on the Improvement of Force Fighting Phenomenon in the Redundant Hydraulic Servo Actuators (다중 유압 서보 작동기의 force fighting 현상 개선에 관한 연구)

  • Lee, Hee-Joong;Choi, Hyung-Don;Kang, E-Sok
    • Aerospace Engineering and Technology
    • /
    • v.12 no.1
    • /
    • pp.54-63
    • /
    • 2013
  • In general, multiple hydraulic servo actuators are installed on one control surface of aero-dynamically highly loaded condition aircraft for redundancy management to satisfy flight control safety requirements. If motions of multiple actuators are not synchronized, control surface is deformed from its free stressed state. In result, force fight conditions are generated on each actuator due to restoration reaction force of deformed control surface. In addition, force fight is induced from severe initial rigging tolerance. Force fight condition of multiple actuators affects control accuracies and reduces operational life of actuators and control surface due to fatigue phenomenon. In this study, we designed controller using force feedback to reduce force fight of duplex servo actuation system.

Development of Smart Switchgear for Versatile Ventilation Garments: Optimum Diameter and Voltage Application Unit Time of One-way Shape Memory Alloy Wire for a Bi-directional Actuator (가변 통기성 의복을 위한 스마트 개폐장치 개발: 양방향 작동 액추에이터 제작을 위한 일방향 형상기억합금 와이어의 최적 직경 및 전압인가 단위시간의 도출)

  • Kim, Sanggu;Kim, Minsung;Yoo, Shinjung
    • Science of Emotion and Sensibility
    • /
    • v.21 no.2
    • /
    • pp.137-144
    • /
    • 2018
  • The study figured out the operational conditions of a two-way movement actuator made of one-way shape memory alloy (OWSMA) for versatile ventilation intelligent garments. To develop a low-power actuator that consumes energy only when a garment changes its form such as opening and closing, multiple channels of OWSMA were used, and optimum diameter of the wires was examined. For the switch device, optimum voltage application unit time was determined. Optimum diameter of OWSMA wire was determined by applying 3.7V to the pre-determined candidate diameters, which demonstrated two-way operation in previous studies. In order to evaluate the optimum voltage application time, the internal diameter of the actuator was measured while increasing and decreasing by 50 ms from the unit time of voltage application. Delay time under two-way operation of the actuator was measured to minimize interference caused by heat between channels. Power of 3.7V was applied to OWSMA for assessment of optimal time, and the whole process from heating to cooling was video-recorded with a thermal image camera to determine the point of time at which the temperature of OWSMA wire dropped below the phase transformation temperature. The results showed that $0.4{\Phi}$ was the most suitable diameter, and the optimum unit time of voltage applied to open and close the actuator was 4100ms. It was also shown that the delay time should be more than 1.8 seconds between two-way operations of the actuator.